Motor Frame Size Motor Frame Size |
---|
Motor Enclosure Type Motor Enclosure Type |
---|
|
Maximum Speed Maximum Speed |
---|
|
Mounting Orientation Mounting Orientation |
---|
|
Starting Torque Starting Torque |
---|
Enclosure Material Enclosure Material |
---|
|
Full Load Current Full Load Current |
---|
|
Direction of Operation Direction of Operation |
---|
|
Continuous Operating Torque @ 460V AC Continuous OperatingTorque @ 460V AC |
---|
|
Wire Connection Type Wire Connection Type |
---|
|
Specifications Met Specifications Met |
---|
|
When replacing a motor, use the information on your motor’s nameplate to guide your selection.
More
Select a motor that fits many applications—these mount from the base or face and at any angle. They're rated for continuous duty and have a keyed shaft that includes key stock. Wire for clockwise or counterclockwise rotation; instructions are included.
Choose a three-phase motor, which is inverter rated, if you want to use a variable frequency drive (AC motor speed control).
Washdown motors have an epoxy-coated enclosure, neoprene rubber gaskets, and removable drain plugs. They meet IP55 for protection from water projected from a nozzle.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base (A) | Base Type | Class | Max. Temp., ° F | Environmental Rating | Each | |
208-230/460 Volts AC, Three Phase | ||||||||||||||||
General Purpose NEMA 145TC | ||||||||||||||||
2 | 1,755 | 6-5.8/2.9 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 9 1/2" | 7 1/4" | 7/8" | 2 1/4" | 3 1/2" | Welded | F | 311° | __ | 00000000 | 0000000 |
General Purpose NEMA 56C | ||||||||||||||||
1/3 | 1,725 | 1.9-1.6/0.8 | Yes | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 6 3/4" | 5/8" | 1 7/8" | 3 1/2" | Welded | B | 266° | __ | 00000000 | 000000 |
3/4 | 1,725 | 3.2-3/1.5 | Yes | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 6 3/4" | 5/8" | 1 7/8" | 3 1/2" | Welded | B | 266° | __ | 00000000 | 000000 |
1 | 1,760 | 3.1-3/1.5 | Yes | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | Welded | F | 311° | __ | 00000000 | 000000 |
Washdown NEMA 56C | ||||||||||||||||
1/2 | 1,740 | 1.8-1.6/0.8 | Yes | Totally Enclosed Nonventilated (TENV) | 11 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | Welded | F | 311° | IP55 | 00000000 | 000000 |
3/4 | 1,750 | 3-2.8/1.4 | Yes | Totally Enclosed Nonventilated (TENV) | 11 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | Welded | F | 311° | IP55 | 00000000 | 000000 |
1 | 1,745 | 3-2.9/1.5 | Yes | Totally Enclosed Nonventilated (TENV) | 12 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | Welded | F | 311° | IP55 | 00000000 | 000000 |
2 | 1,755 | 6-5.8/2.9 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 9 1/2" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | Welded | F | 311° | IP55 | 00000000 | 00000000 |
230/460 Volts AC, Three Phase | ||||||||||||||||
General Purpose NEMA 56C | ||||||||||||||||
1/2 | 1,740 | 1.6 | Yes | Totally Enclosed Nonventilated (TENV) | 11 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | Welded | F | 311° | __ | 00000000 | 000000 |
Replace old base-mount motors to keep your equipment moving. Motors are rated for continuous duty and mount at any angle. You can wire for clockwise or counterclockwise rotation; instructions are included.
To use a motor with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
Motors with a welded base have a base that's welded to the enclosure. Motors with a vibration-damping base have rubber rings between the base and enclosure to minimize vibration.
Motors with overload protection turn off in overload conditions to prevent motor damage. Automatic overload protection starts the motor automatically after it cools.
For technical drawings and 3-D models, click on a part number.
O'all | Shaft | Insulation | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base (A) | Shaft Type | Overload Protection Type | Class | Max. Temp., ° F | Each | |
115/208-230 Volts AC, Single Phase | ||||||||||||||||
NEMA 56/NEMA 56H—Vibration-Damping Base | ||||||||||||||||
1 | 1,725 | 13.4/7.4-6.7 | No | Open Dripproof (ODP) | 11 1/2" | 6 3/4" | 9 1/4" | 5/8" | 1 7/8" | 3 1/2" | Keyed | Automatic | B | 266° | 0000000 | 0000000 |
208-230/460 Volts AC, Three Phase | ||||||||||||||||
NEMA 56—Welded Base | ||||||||||||||||
1/4 | 1,750 | 0.8-0.8/0.4 | Yes | Totally Enclosed Nonventilated (TENV) | 11 1/4" | 9 1/4" | 7" | 5/8" | 1 7/8" | 3 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
1 | 1,760 | 3.1-3/1.5 | Yes | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | Keyed | __ | F | 311° | 0000000 | 000000 |
1 1/2 | 1,760 | 4.5-4.4/2.2 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 9 1/2" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | Keyed | __ | F | 311° | 0000000 | 000000 |
NEMA 143T—Welded Base | ||||||||||||||||
1 | 1,760 | 3.1-3/1.5 | Yes | Open Dripproof (ODP) | 11 1/4" | 9" | 7" | 7/8" | 2 1/4" | 3 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
1 | 1,760 | 3.1-3/1.5 | Yes | Totally Enclosed Fan Cooled (TEFC) | 12 1/2" | 9 1/2" | 7 1/4" | 7/8" | 2 1/4" | 3 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
NEMA 145T—Welded Base | ||||||||||||||||
1 1/2 | 1,755 | 4.5-4.4/2.2 | Yes | Open Dripproof (ODP) | 11 3/4" | 9" | 7" | 7/8" | 2 1/4" | 3 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
1 1/2 | 1,760 | 4.5-4.4/2.2 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/2" | 9 1/2" | 7 1/4" | 7/8" | 2 1/4" | 3 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
2 | 1,750 | 5.8-5.8/2.9 | Yes | Open Dripproof (ODP) | 12 1/4" | 9" | 7" | 7/8" | 2 1/4" | 3 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
2 | 1,755 | 5.8-5.8/2.9 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 9 1/2" | 7 1/4" | 7/8" | 2 1/4" | 3 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
2 | 3,490 | 5.3-5/2.5 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/2" | 9 1/2" | 7 1/4" | 7/8" | 2 1/4" | 3 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
NEMA 182T—Welded Base | ||||||||||||||||
3 | 1,760 | 8.9-8.8/4.4 | Yes | Open Dripproof (ODP) | 15" | 11 1/4" | 8 1/2" | 1 1/8" | 2 3/4" | 4 1/2" | Keyed | Automatic | F | 311° | 00000000 | 000000 |
3 | 1,760 | 9-8.4/4.2 | Yes | Totally Enclosed Fan Cooled (TEFC) | 16 3/4" | 11 1/4" | 11" | 1 1/8" | 2 3/4" | 4 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
NEMA 184T—Welded Base | ||||||||||||||||
5 | 1,750 | 13.9-13.4/6.7 | Yes | Totally Enclosed Fan Cooled (TEFC) | 18 1/4" | 11 1/4" | 11" | 1 1/8" | 2 3/4" | 4 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
5 | 1,750 | 14-13.2/6.6 | Yes | Open Dripproof (ODP) | 16 1/2" | 11 1/4" | 9" | 1 1/8" | 2 3/4" | 4 1/2" | Keyed | Automatic | F | 311° | 00000000 | 000000 |
NEMA 213T—Welded Base | ||||||||||||||||
7 1/2 | 1,770 | 19.8-19/9.5 | Yes | Totally Enclosed Fan Cooled (TEFC) | 18 1/2" | 15" | 13" | 1 3/8" | 3 3/8" | 5 1/4" | Keyed | __ | F | 311° | 00000000 | 00000000 |
NEMA 215T—Welded Base | ||||||||||||||||
10 | 1,760 | 26.5-24.4/12.2 | Yes | Totally Enclosed Fan Cooled (TEFC) | 18 1/2" | 15" | 13" | 1 3/8" | 3 3/8" | 5 1/4" | Keyed | __ | F | 311° | 00000000 | 00000000 |
230/460 Volts AC, Three Phase | ||||||||||||||||
NEMA 145T—Welded Base | ||||||||||||||||
3 | 3,450 | 7.6/3.8 | Yes | Open Dripproof (ODP) | 13" | 9" | 7" | 7/8" | 2 1/4" | 3 1/2" | Keyed | __ | F | 311° | 00000000 | 000000 |
Also known as C-face motors, these bolt directly to your equipment at any angle. They're rated for continuous duty and have a keyed shaft that comes with key stock. You can wire for clockwise or counterclockwise rotation; instructions are included.
To use a motor with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base (A) | Class | Max. Temp., ° F | Each | |
208-230/460 Volts AC, Three Phase | ||||||||||||||
NEMA 145TC | ||||||||||||||
1 1/2 | 1,760 | 4.5-4.4/2.2 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/2" | 9 1/2" | 7 1/4" | 7/8" | 2 1/4" | 3 5/8" | F | 311° | 00000000 | 0000000 |
2 | 1,755 | 5.8-5.8/2.9 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 9 1/2" | 7 1/4" | 7/8" | 2 1/4" | 3 5/8" | F | 311° | 00000000 | 000000 |
NEMA 56C | ||||||||||||||
1 1/2 | 1,760 | 4.5-4.4/2.2 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 8 7/8" | 7 1/4" | 5/8" | 1 7/8" | 3 5/8" | F | 311° | 00000000 | 000000 |
2 | 1,755 | 6.6-5.8/2.9 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 8 7/8" | 7 1/4" | 5/8" | 1 7/8" | 3 5/8" | F | 311° | 00000000 | 000000 |
Bolt these motors directly to conveyors, pumps, and other equipment to keep things moving in sanitary environments. They’re also known as C-face motors. Rated IP56 or IP69, they hold up to the washdowns that are often required in food-safe areas. These face-mount motors are designed without feet, so it’s easy to clean the entire motor body. For extra protection from washdowns, the interior of the motor is completely lined with epoxy resin. A two-barrier shaft seal prevents liquids from entering the motor through the shaft. They also have a face-mount drain to allow liquids to escape from the face cavity, so they don’t linger there and stagnate.
Made from 303 or 304 stainless steel, these motors won’t corrode from frequent washdowns with harsh cleaners and sanitizers. They have rounded edges and smooth surfaces so that there are no crevices where bacteria can grow. A laser-marked nameplate gives you permanent identification information without any bolts, engravings, or adhesive labels that can trap contaminants.
These motors are rated for continuous duty, so you can run equipment that never goes offline. Some are also inverter rated, which means you can use them with variable frequency drives, or VFDs, to run them at different speeds for different tasks.
TEFC (totally enclosed fan cooled) motors have an external fan that blows air over the outside housing for cooling. TENV (totally enclosed non-vented) motors do not require a fan or other ventilation. This type of body has fewer areas where water and contaminants can enter than TEFC motors.
Motors with a rotatable conduit box eliminate the need to reroute power during installation. The conduit box rotates 360° (90° at a time) so you can connect conduit from any side.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | Torque @ 460V AC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base (A) | Shaft Type | Class | Max. Temp., °F | Starting Torque, in.-lbs. | Continuous Operating Torque, in.-lbs. | Environmental Rating | Each | |
208-230/460 Volts AC, Three Phase | |||||||||||||||||
NEMA 56C—Totally Enclosed Fan Cooled (TEFC) with Rotatable Conduit Box | |||||||||||||||||
1/2 | 1,800 | 1.8/0.9 | Yes | 13" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 221° | 61 | 17.8 | IP69 | 0000000 | 000000000 |
3/4 | 1,800 | 2.6/1.3 | Yes | 14" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 221° | 96.1 | 26.8 | IP69 | 0000000 | 00000000 |
1 | 1,800 | 3.1-3/1.5 | Yes | 14" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 221° | 114 | 36 | IP69 | 0000000 | 00000000 |
NEMA 56C—Totally Enclosed Nonventilated (TENV) with Rotatable Conduit Box | |||||||||||||||||
1/2 | 3,600 | 1.5-1.4/0.7 | Yes | 11 3/4" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 221° | 32.8 | 9 | IP69 | 0000000 | 00000000 |
3/4 | 3,600 | 2.1-2/1 | Yes | 11 3/4" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 221° | 56.8 | 13.5 | IP69 | 0000000 | 00000000 |
1 | 3,600 | 2.9-2.8/1.4 | Yes | 11 3/4" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 221° | 96.1 | 18.2 | IP69 | 0000000 | 00000000 |
NEMA 143TC—Totally Enclosed Fan Cooled (TEFC) with Rotatable Conduit Box | |||||||||||||||||
1 | 1,800 | 3.1-3/1.5 | Yes | 14" | 9 7/8" | 6 1/2" | 7/8" | 2 1/8" | 3 1/4" | Keyed | H | 221° | 114 | 36 | IP69 | 0000000 | 00000000 |
IEC 71—Totally Enclosed Nonventilated (TENV) | |||||||||||||||||
1/3 | 1,725 | 1.3-1.3/0.65 | No | 9 3/4" | 6" | 6" | 13mm | 27mm | 77mm | Keyed | F | 311° | 824.4 | 955.2 | IP56 | 00000000 | 000000 |
1/3 | 1,725 | 1.3-1.3/0.65 | No | 9 3/4" | 6" | 6" | 13mm | 27mm | 77mm | Keyed | F | 311° | 835.2 | 192 | IP56 | 00000000 | 00000000 |
1/2 | 1,725 | 1.9-1.8/0.9 | No | 11 1/2" | 6" | 6" | 13mm | 27mm | 77mm | Keyed | F | 311° | 1,208.4 | 288 | IP56 | 00000000 | 00000000 |
1/2 | 1,725 | 1.9-1.8/0.9 | No | 11 1/2" | 6" | 6" | 13mm | 27mm | 77mm | Keyed | F | 311° | 1,272 | 288 | IP56 | 00000000 | 00000000 |
IEC 80—Totally Enclosed Fan Cooled (TEFC) | |||||||||||||||||
3/4 | 1,725 | 2.5-2.4/1.2 | No | 12 1/4" | 6" | 6" | 18mm | 37mm | 77mm | Keyed | F | 311° | 432 | 1,740 | IP56 | 00000000 | 00000000 |
3/4 | 1,725 | 2.5-2.4/1.2 | No | 12 1/2" | 6" | 6" | 18mm | 37mm | 77mm | Keyed | F | 311° | 1,740 | 1,680 | IP56 | 00000000 | 00000000 |
IEC 80—Totally Enclosed Nonventilated (TENV) | |||||||||||||||||
1/3 | 1,725 | 1.3-1.3/0.65 | No | 9 3/4" | 6" | 6" | 18mm | 37mm | 77mm | Keyed | F | 311° | 855.2 | 835.2 | IP56 | 00000000 | 000000 |
1/3 | 1,725 | 1.3-1.3/0.65 | No | 9 3/4" | 6" | 6" | 18mm | 37mm | 77mm | Keyed | F | 311° | 955.2 | 192 | IP56 | 00000000 | 000000 |
1/2 | 1,725 | 1.9-1.8/0.9 | No | 11 1/2" | 6" | 6" | 18mm | 37mm | 77mm | Keyed | F | 311° | 1,200 | 1,208.4 | IP56 | 00000000 | 00000000 |
1/2 | 1,725 | 1.9-1.8/0.9 | No | 11 1/2" | 6" | 6" | 18mm | 37mm | 77mm | Keyed | F | 311° | 1,200 | 1,272 | IP56 | 00000000 | 00000000 |
IEC 90L—Totally Enclosed Fan Cooled (TEFC) with Rotatable Conduit Box | |||||||||||||||||
2 | 1,745 | 6-5.8/2.9 | Yes | 13 3/4" | 10" | 7 1/4" | 23mm | 50mm | 92mm | Keyed | F | 311° | 72 | 295.2 | IP56 | 00000000 | 00000000 |
230/460 Volts AC, Three Phase | |||||||||||||||||
NEMA 56C—Totally Enclosed Fan Cooled (TEFC) with Rotatable Conduit Box | |||||||||||||||||
1 1/2 | 1,800 | 4.4/2.2 | Yes | 14" | 9 7/8" | 6 1/2" | 5/8" | 2" | 3 1/4" | Keyed | H | 221° | 156.6 | 53.5 | IP69 | 0000000 | 00000000 |
2 | 1,800 | 5.6/2.8 | Yes | 14" | 9 7/8" | 6 1/2" | 5/8" | 2" | 3 1/4" | Keyed | H | 221° | 208 | 72.1 | IP69 | 0000000 | 00000000 |
NEMA 56C—Totally Enclosed Nonventilated (TENV) with Rotatable Conduit Box | |||||||||||||||||
1 1/2 | 3,600 | 3.6/1.8 | Yes | 13 3/4" | 9 7/8" | 6 1/2" | 5/8" | 2" | 3 1/4" | Keyed | H | 221° | 122.4 | 27.7 | IP69 | 0000000 | 00000000 |
2 | 3,600 | 4.8/2.4 | Yes | 15" | 9 7/8" | 6 1/2" | 5/8" | 2" | 3 1/4" | Keyed | H | 221° | 165.6 | 35.8 | IP69 | 0000000 | 00000000 |
NEMA 143TC—Totally Enclosed Nonventilated (TENV) with Rotatable Conduit Box | |||||||||||||||||
1 1/2 | 3,600 | 3.6/1.8 | Yes | 13 3/4" | 9 7/8" | 6 1/2" | 7/8" | 2 1/8" | 3 1/4" | Keyed | H | 221° | 122.4 | 27.7 | IP69 | 0000000 | 00000000 |
NEMA 145TC—Totally Enclosed Fan Cooled (TEFC) with Rotatable Conduit Box | |||||||||||||||||
1 1/2 | 1,800 | 4.4/2.2 | Yes | 14" | 9 7/8" | 6 1/2" | 7/8" | 2 1/8" | 3 1/4" | Keyed | H | 221° | 156.6 | 53.5 | IP69 | 0000000 | 00000000 |
2 | 1,800 | 5.6/2.8 | Yes | 14" | 9 7/8" | 6 1/2" | 7/8" | 2 1/8" | 3 1/4" | Keyed | H | 221° | 208 | 72.1 | IP69 | 0000000 | 00000000 |
2 | 3,600 | 5/2.5 | Yes | 14 7/8" | 9 7/8" | 6 1/2" | 7/8" | 2 1/8" | 3 1/4" | Keyed | H | 221° | 165.6 | 35.8 | IP69 | 0000000 | 00000000 |
3 | 3,600 | 7.4/3.7 | Yes | 16 1/4" | 9 7/8" | 6 1/2" | 7/8" | 2 1/8" | 3 1/4" | Keyed | H | 221° | 204 | 54 | IP69 | 0000000 | 00000000 |
IEC 143C—Totally Enclosed Fan Cooled (TEFC) with Rotatable Conduit Box | |||||||||||||||||
1 1/2 | 1,750 | 4.8/2.4 | Yes | 13 1/4" | 10" | 7 1/4" | 22mm | 50mm | 92mm | Keyed | F | 311° | 204 | 206.4 | IP56 | 00000000 | 00000000 |
For the most mounting versatility in sanitary and washdown environments, these motors mount in two ways. Bolt them down through their feet, or face-mount them directly to your conveyor, pump, or other machine. They have an IP69 rating, so they'll hold up to the high-pressure, high-temperature cleaning cycles common in food-processing and other sanitary environments. A two-barrier seal keep liquids from entering through the motor shaft, and an epoxy resin coating protects the interior. Holes on the face of the motor drain any liquid that finds its way into the mounting cavity.
Made of 304 stainless steel, these motors stand up to frequent washdowns with harsh cleaners without rusting. Critical for sanitary environments, these motors reduce the chances of foodborne illnesses by making thorough cleaning possible. Smooth contours, continuous welds, and a laser-marked nameplate with no bolts or labels give bacteria no place to hide.
Designed for industrial food processing lines that never go offline, these motors can run continuously. They're also inverter rated, which means you can use them with variable frequency drives, or VFDs, to run them at different speeds for different tasks. The motor's conduit connection rotates 360° (90° at a time) so you won't have to reroute your power supply.
TEFC (totally enclosed fan cooled) motors have an external fan that blows air over the outside housing for cooling. TENV (totally enclosed nonventilated) motors do not require a fan or other ventilation. This type of body has fewer areas where water and contaminants can enter than TEFC motors.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | Torque @ 460V AC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Shaft Type | Class | Max. Temp., °F | Starting Torque, in.-lbs. | Continuous Operating Torque, in.-lbs. | Environmental Rating | Each | |
208-230/460 Volts AC, Three Phase | |||||||||||||||||
NEMA 56C—Totally Enclosed Nonventilated (TENV) | |||||||||||||||||
1/2 | 1,800 | 1.8/0.9 | Yes | 11 3/4" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 61.1 | 17.9 | IP69 | 0000000 | 000000000 |
1/2 | 3,600 | 1.5-1.4/0.7 | Yes | 11 3/4" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 32.9 | 9 | IP69 | 0000000 | 00000000 |
3/4 | 1,800 | 2.6/1.3 | Yes | 12 3/4" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 97.2 | 26.9 | IP69 | 0000000 | 00000000 |
3/4 | 3,600 | 2.1-2/1 | Yes | 11 3/4" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 56.9 | 13.6 | IP69 | 0000000 | 00000000 |
230/460 Volts AC, Three Phase | |||||||||||||||||
NEMA 56C—Totally Enclosed Fan Cooled (TEFC) | |||||||||||||||||
1 1/2 | 1,800 | 4.4/2.2 | Yes | 14" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 156.6 | 53.5 | IP69 | 0000000 | 00000000 |
2 | 1,800 | 5.6/2.8 | Yes | 14" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 208.1 | 72.1 | IP69 | 0000000 | 00000000 |
2 | 3,600 | 5/2.5 | Yes | 14 7/8" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 165.6 | 35.9 | IP69 | 0000000 | 00000000 |
NEMA 56C—Totally Enclosed Nonventilated (TENV) | |||||||||||||||||
1 | 1,800 | 3/1.5 | Yes | 12 3/4" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 114 | 36 | IP69 | 0000000 | 00000000 |
1 | 3,600 | 2.8/1.4 | Yes | 11 3/4" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 96.1 | 18.2 | IP69 | 0000000 | 00000000 |
1 1/2 | 3,600 | 3.6/1.8 | Yes | 13 5/8" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 221° | 122.4 | 27.7 | IP69 | 0000000 | 00000000 |
NEMA 143TC—Totally Enclosed Nonventilated (TENV) | |||||||||||||||||
1 | 1,800 | 3/1.5 | Yes | 12 7/8" | 9 3/4" | 6 3/4" | 7/8" | 2 1/8" | 3 1/2" | Keyed | H | 221° | 114 | 36 | IP69 | 0000000 | 00000000 |
1 1/2 | 3,600 | 3.6/1.8 | Yes | 13 3/4" | 9 3/4" | 6 3/4" | 7/8" | 2 1/8" | 3 1/2" | Keyed | H | 221° | 122.4 | 27.7 | IP69 | 0000000 | 00000000 |
NEMA 145TC—Totally Enclosed Fan Cooled (TEFC) | |||||||||||||||||
1 1/2 | 1,800 | 4.4/2.2 | Yes | 14" | 9 3/4" | 6 3/4" | 7/8" | 2 1/8" | 3 1/2" | Keyed | H | 221° | 156.6 | 53.5 | IP69 | 0000000 | 00000000 |
2 | 1,800 | 5.6/2.8 | Yes | 14" | 9 3/4" | 6 3/4" | 7/8" | 2 1/8" | 3 1/2" | Keyed | H | 221° | 208.1 | 72.1 | IP69 | 0000000 | 00000000 |
2 | 3,600 | 5/2.5 | Yes | 14 7/8" | 9 3/4" | 6 3/4" | 7/8" | 2 1/8" | 3 1/2" | Keyed | H | 221° | 165.6 | 35.9 | IP69 | 0000000 | 00000000 |
3 | 3,600 | 7.4/3.7 | Yes | 16 1/4" | 9 3/4" | 6 3/4" | 7/8" | 2 1/8" | 3 1/2" | Keyed | H | 221° | 204 | 54 | IP69 | 0000000 | 00000000 |
![]() Gearmotor | ![]() |
![]() Optional Shaft |
A motor and speed reducer in one, these gearmotors have hypoid gears for energy-efficient operation. You can use them to turn a shaft on your equipment or add a keyed shaft (sold separately). Wire for clockwise or counterclockwise rotation; instructions are included. Gearmotors meet IP54 for protection from dust and splashed water. They're inverter rated so you can use them with a motor speed control (not included) to adjust the motor speed.
For technical drawings and 3-D models, click on a part number.
Gearmotors | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Output | Optional Keyed Shafts with Key Stock | ||||||||||
Power, hp | Speed @ Continuous Operating Torque | Full Load Current, A | Lg. | Wd. | Ht. | For Shaft Dia. | Shaft Center to Base (A) | Environmental Rating | Each | Each | ||
230 Volts AC, Three Phase | ||||||||||||
1/15 | 7 rpm @ 470 in.-lbs. | 0.39 | 13" | 4" | 6" | 3/4" | 1.91" | IP54 | 0000000 | 0000000 | 0000000 | 000000 |
1/8 | 7 rpm @ 900 in.-lbs. | 0.85 | 13 1/2" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/8 | 14 rpm @ 440 in.-lbs. | 0.63 | 13" | 4" | 6" | 3/4" | 1.91" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/8 | 14 rpm @ 450 in.-lbs. | 0.85 | 13 1/2" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/8 | 28 rpm @ 220 in.-lbs. | 0.63 | 13" | 4" | 6" | 3/4" | 1.91" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/8 | 42 rpm @ 145 in.-lbs. | 0.63 | 13" | 4" | 6" | 3/4" | 1.91" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/8 | 56 rpm @ 105 in.-lbs. | 0.63 | 13" | 4" | 6" | 3/4" | 1.91" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/8 | 84 rpm @ 73 in.-lbs. | 0.63 | 13" | 4" | 6" | 3/4" | 1.91" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/8 | 168 rpm @ 35 in.-lbs. | 0.63 | 13" | 4" | 6" | 3/4" | 1.91" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 28 rpm @ 360 in.-lbs. | 1.1 | 13 1/2" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 42 rpm @ 240 in.-lbs. | 1.1 | 13 1/2" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 56 rpm @ 180 in.-lbs. | 1.1 | 13 1/2" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 84 rpm @ 120 in.-lbs. | 1.1 | 13 1/2" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 168 rpm @ 60 in.-lbs. | 1.1 | 13 1/2" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/4 | 7 rpm @ 1,730 in.-lbs. | 1.55 | 14 1/4" | 5 1/2" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/4 | 14 rpm @ 871 in.-lbs. | 1.55 | 14 1/4" | 5 1/2" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 27 rpm @ 982 in.-lbs. | 1.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 40 rpm @ 655 in.-lbs. | 1.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 53 rpm @ 487 in.-lbs. | 1.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 80 rpm @ 327 in.-lbs. | 1.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 160 rpm @ 168 in.-lbs. | 1.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
230/400-460 Volts AC, Three Phase | ||||||||||||
1/8 | 7 rpm @ 900 in.-lbs. | 0.9/0.7-0.6 | 15 1/4" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/8 | 14 rpm @ 450 in.-lbs. | 0.9/0.7-0.6 | 15 1/4" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 28 rpm @ 360 in.-lbs. | 1.2/0.9-0.8 | 15 1/4" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 42 rpm @ 240 in.-lbs. | 1.2/0.9-0.8 | 15 1/4" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 56 rpm @ 180 in.-lbs. | 1.2/0.9-0.8 | 15 1/4" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 84 rpm @ 120 in.-lbs. | 1.2/0.9-0.8 | 15 1/4" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/5 | 168 rpm @ 60 in.-lbs. | 1.2/0.9-0.8 | 15 1/4" | 4 3/4" | 6 3/4" | 1" | 2.11" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/4 | 7 rpm @ 1,730 in.-lbs. | 1.25/1-0.9 | 16" | 5 1/2" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/4 | 14 rpm @ 871 in.-lbs. | 1.25/1-0.9 | 16" | 5 1/2" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 27 rpm @ 982 in.-lbs. | 1.94/1-0.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 40 rpm @ 655 in.-lbs. | 1.94/1-0.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 53 rpm @ 487 in.-lbs. | 1.94/1-0.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 80 rpm @ 327 in.-lbs. | 1.94/1-0.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |
1/2 | 160 rpm @ 168 in.-lbs. | 1.94/1-0.9 | 13 3/4" | 6" | 7 3/4" | 1 1/4" | 2.28" | IP54 | 0000000 | 000000 | 0000000 | 00000 |