For Use With For Use With |
---|
|
For Container Type For Container Type |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Mounting Location Mounting Location |
---|
|
Environmental Rating Environmental Rating |
---|
Connection Type Connection Type |
---|
|
Body Material Body Material |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Seal Material Seal Material |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Liquid-Level Transmitters


Also known as level loggers, level sensors, and pressure transducers, these transmitters sit at the bottom of your tank in applications that make traditional mounting difficult. They sense and transmit level information through a signal. All are FM approved for Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2.
Transmitters with nose cone protect the sensing element from the effects of pressure surges.
Transmitters for water with solids have an unobstructed sensing element that resists clogging and sludge buildup in water with particulate and sewage.
For technical drawings and 3-D models, click on a part number.
Overall | Temp. Range, °F | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Liquid Level, ft. | Accuracy | Max. Pressure | Lg. | Dia. | Cable Lg., ft. | Min. | Max. | For Container Type | Electrical Connection | Input Voltage | Output Current | Environmental Rating | Each | |
316L Stainless Steel Body with Nose Cone | ||||||||||||||
For Water | ||||||||||||||
0-3 | ±0.25% | 1 psi @ 70° F | 6 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 0000000 |
0-5 | ±0.25% | 2 psi @ 70° F | 6 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-10 | ±0.25% | 4 psi @ 70° F | 6 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-15 | ±0.25% | 6 psi @ 70° F | 6 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-30 | ±0.25% | 13 psi @ 70° F | 6 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
316L Stainless Steel Body | ||||||||||||||
For Water with Solids | ||||||||||||||
0-3 | ±0.25% | 1 psi @ 70° F | 5 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-5 | ±0.25% | 2 psi @ 70° F | 5 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-10 | ±0.25% | 4 psi @ 70° F | 5 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-15 | ±0.25% | 6 psi @ 70° F | 5 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
0-30 | ±0.25% | 13 psi @ 70° F | 5 3/4" | 1" | 40 | -10° | 175° | Open Tank | Wire Leads | 10V DC-35V DC | 4 mA-20 mA | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
Noncontact Liquid-Level Transmitters

Measure liquid level with sound waves—these transmitters don’t come into contact with the liquid so you don't have to worry about fluid compatibility or contamination. Mount at the top of your tank. The housing is rated NEMA 4X and NEMA 6 for protection from corrosion, washdowns, and temporary submersion.
For technical drawings and 3-D models, click on a part number.
Overall | Temp. Range, °F | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Liquid Level | Pipe Size | Max. Pressure | Dia. | Lg. | Cable Lg., ft. | Min. | Max. | For Container Type | Electrical Connection | Input Voltage | Output Current | Environmental Rating | Each | |
PVC Plastic Body with NPT Male Thread | ||||||||||||||
For Water and Water with Solids | ||||||||||||||
4"-6 ft. | 1 | 15 psi @ 70° F | 4" | 4 1/8" | 5 | -40° | 140° | Closed Tank, Open Tank | Wire Leads | 12V DC-30V DC | 4 mA-20 mA | IP68, NEMA 4X, NEMA 6 | 0000000 | 0000000 |
Ultrasonic Transmitters
Measure the distance to objects and the level of liquids and materials despite size, shape, or surface finish, and send that information to other parts of your system. Unlike photoelectric switches, which use light to detect objects, these transmitters emit high-frequency sound waves that target small spots, so the surface and structure of your object won’t affect results. This makes them great for materials with uneven surfaces, such as granules and powder. They also sense objects in dirty and wet places, but they don’t work well where there’s wind, since it could disrupt their sound waves. Use their plug to quickly connect and disconnect to cables with a socket (sold separately). UL listed, C-UL listed, and CE marked, they meet American, Canadian, and European safety standards.
All transmitters have an analog output, which means they continuously send measurements to monitor status and manage components in your system. Some also have a digital output that signals your controller to turn components on or off whenever an object is detected or a set level is reached. Those with IO Link connect to a programmable logic controller (PLC), so you can remotely change settings and receive error messages. You need an IO-Link controller (not included) to connect.
90° elbow transmitters are compact to fit in tight spaces. They’re best for conveyors.
Rated IP67, all of these transmitters seal out dust and water if briefly submersed.
For technical drawings and 3-D models, click on a part number.


Micro
M12 Plug
Transmitters | Cables with Socket | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Outputs | Signal Output Type | Signal Output | Sensing Distance, mm | Input Voltage | Communication Protocol | Dia., mm | Lg., mm | Housing Material | Circuit Protection | Temp. Range, °F | Environmental Rating | Each | Each | ||
With 4-Pole Micro M12 Plug | |||||||||||||||
Analog | |||||||||||||||
1 | __ | 4mA-20mA | 40-300 | 10V DC-30V DC | __ | 18 | 61 | Stainless Steel | Overload, Reverse Polarity, Short Circuit | 0° to 155° | IP67 | 0000000 | 0000000 | 0000000 | 000000 |
1 | __ | 4mA-20mA | 80-1,200 | 10V DC-30V DC | __ | 18 | 61 | Stainless Steel | Overload, Reverse Polarity, Short Circuit | 0° to 155° | IP67 | 0000000 | 000000 | 0000000 | 00000 |
Digital/Analog | |||||||||||||||
2 | PNP | 4mA-20mA | 150-1,600 | 10V DC-30V DC | IO Link | 18 | 98 | Stainless Steel | Overload, Reverse Polarity, Short Circuit | 0° to 155° | IP67 | 0000000 | 000000 | 0000000 | 00000 |
2 | PNP | 4mA-20mA | 250-3,500 | 10V DC-30V DC | IO Link | 30 | 103 | Stainless Steel | Overload, Reverse Polarity, Short Circuit | 0° to 155° | IP67 | 0000000 | 000000 | 0000000 | 00000 |


Micro
M12 Plug
Transmitters | Cables with Socket | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Outputs | Signal Output Type | Signal Output | Sensing Distance, mm | Input Voltage | Dia., mm | Lg., mm | Wd., mm | Ht., mm | Housing Material | Circuit Protection | Temp. Range, °F | Environmental Rating | Each | Each | ||
With 4-Pole Micro M12 Plug | ||||||||||||||||
Digital/Analog | ||||||||||||||||
2 | PNP | 4mA-20mA | 40-300 | 10V DC-30V DC | 18 | 38 | 20 | 53 | Plastic | Overload, Reverse Polarity, Short Circuit | 0° to 155° | IP67 | 0000000 | 0000000 | 0000000 | 000000 |
2 | PNP | 4mA-20mA | 80-1,200 | 10V DC-30V DC | 18 | 38 | 20 | 53 | Plastic | Overload, Reverse Polarity, Short Circuit | 0° to 155° | IP67 | 0000000 | 000000 | 0000000 | 00000 |
2 | PNP | 0V DC-10V DC | 40-300 | 10V DC-30V DC | 18 | 38 | 20 | 53 | Plastic | Overload, Reverse Polarity, Short Circuit | 0° to 155° | IP67 | 0000000 | 000000 | 0000000 | 00000 |
2 | PNP | 0V DC-10V DC | 80-1,200 | 10V DC-30V DC | 18 | 38 | 20 | 53 | Plastic | Overload, Reverse Polarity, Short Circuit | 0° to 155° | IP67 | 0000000 | 000000 | 0000000 | 00000 |
Starrett Wireless Transmitters
Wirelessly transmit data from measuring tools with SPC output to a PC. Select the transmitter with the connection that is compatible with your measuring tool’s SPC output port. A wireless receiver (sold separately) is required. Measurement data can be imported into Microsoft Excel or any SPC software.



Starrett Measuring Tool Connection Type | Communication Range, ft. | Lg. | Wd. | Ht. | Power Source | Batteries Included | Manufacturer Series | Manufacturer Model No. | For Manufacturer Series | Each | |
4 Pin | 65 | 2" | 2" | 1/2" | Battery | Yes | 1500 | 1500-3A-21N | 2900 | 0000000 | 0000000 |
Mini Connector | 65 | 2" | 2" | 1/2" | Battery | Yes | 1500 | 1500-3A-4N | 2700 | 0000000 | 000000 |
Straight | 65 | 2" | 2" | 1/2" | Battery | Yes | 1500 | 1500-3A-18N | 798 | 0000000 | 000000 |
Replacement Button Cell Battery (Pkg. of 1) | 0000000 | Pkg. | 00000 |

USB Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Computer Connection Type | Standard | Type | Communication Range, ft. | Lg. | Wd. | Ht. | Includes | For Manufacturer Series | Manufacturer Model No. | Each | |
USB | 2.0 | A | 100 | 7" | 5 1/2" | 2 1/2" | USB Cable | 1500 | 1500-1-N | 0000000 | 000000000 |
Mitutoyo Wireless Transmitters
Wirelessly transmit measurement data to a PC. Select the cable with the connection that is compatible with your measuring tool’s SPC output port. A wireless receiver (sold separately) is required. Measurement data can be imported into Microsoft Excel or any SPC software.






Mitutoyo Measuring Tool Connection Type | Communication Range, ft. | Lg. | Wd. | Ht. | Power Source | Batteries Included | Manufacturer Series | Manufacturer Model No. | For Manufacturer Model No. | Each | |
Data Out Switch A | 60 | 1 3/4" | 1 1/4" | 3/4" | Battery | Yes | U-WAVE-T | 02AZD730G-A, 02AZD790A | 500-762-20, 500-763-20, 500-764-10, 552-313-10, 552-314-10, 552-315-10, 571-261-20, 573-701-20, 573-705, 573-721-20, 573-761-20 | 000000 | 0000000 |
Data Out Switch B | 60 | 1 3/4" | 1 1/4" | 3/4" | Battery | Yes | U-WAVE-T | 02AZD730G-B, 02AZD790B | 293-130, 293-330-30, 293-331-30, 293-332-30, 293-333-30, 293-335-30, 293-336-30, 293-350-30, 293-351-30, 314-351-30, 329-350-30, 329-351-30, 340-351-30, 340-352-30, 350-351-30, 350-352-30, 350-354-30, 389-351-30, 422-330-30 | 000000 | 000000 |
Data Out Switch C | 60 | 1 3/4" | 1 1/4" | 3/4" | Battery | Yes | U-WAVE-T | 02AZD730G-C, 02AZD790C | 164-164, 389-714, 500-170-30, 500-171-30, 500-172-30, 500-173, 500-505-10, 500-506-10, 500-507-10, 571-211-30, 571-212-30, 571-213-10, 572-210-30, 572-211-30, 572-213-10, 572-311-10, 572-313-10, 573-291-30 | 000000 | 000000 |
6 Pin | 60 | 1 3/4" | 1 1/4" | 3/4" | Battery | Yes | U-WAVE-T | 02AZD730G-E | 209-954 | 000000 | 000000 |
10 Pin | 60 | 1 3/4" | 1 1/4" | 3/4" | Battery | Yes | U-WAVE-T | 02AZD730G-D, 02AZD790D | 543-562A, 543-564A | 000000 | 000000 |
Straight | 60 | 1 3/4" | 1 1/4" | 3/4" | Battery | Yes | U-WAVE-T | 02AZD730G-F, 02AZD790F | 192-630-10, 192-631-10, 192-632-10, 543-392, 543-392B, 543-402, 543-402B, 543-472B, 543-783, 543-783B, 543-793, 543-793B, 543-796, 543-796B, 547-217S, 547-218S, 547-312S, 547-400S, 547-500S, 547-520S, 547-561S, 570-312, 570-313, 570-314, 570-412, 570-414, 572-475, 575-123 | 000000 | 000000 |
Replacement Button Cell Battery (Pkg. of 1) | 0000000 | Pkg. | 00000 |

USB Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Computer Connection Type | Standard | Type | Communication Range, ft. | Lg. | Wd. | Ht. | Includes | Manufacturer Model No. | For Manufacturer Series | Each | |
USB | 2.0 | A | 60 | 5 1/2" | 3 1/4" | 1 1/4" | USB Cable | 02AZD810D | U-WAVE-T | 000000 | 0000000 |
Mitutoyo Bluetooth Tools

Send measurement data via Bluetooth to PCs, smartphones, and tablets. Download a free app to connect to smartphones and tablets. Use the included USB receiver to connect to a PC. Bluetooth tools cannot be sold in California due to energy efficiency requirements.
Connection Type | Communication Range, ft. | Lg. | Wd. | Dp. | Power Source | Batteries Included | Includes | Cannot Be Sold To | Each | |
10 Pin | 32 | 2 1/2" | 1 3/4" | 3/4" | Battery | Yes | 10-Pin SPC Cable with Mitutoyo Straight Connection, Single/Continuous Capture Switch, USB Charging Cable, USB Outlet Plug, USB Receiver | CA | 0000000 | 0000000 |