About Pressure Gauges
More
Vibration- and Corrosion-Resistant Pressure and Vacuum Gauges



Back Connection
(Panel Mount)




Back Connection
(Panel Mount)




Designed for harsh environments prone to vibration, these gauges pair a corrosion-resistant 304 stainless steel case with a glycerin-filled dial that reduces needle flutter. Also known as compound gauges, they measure both pressure and vacuum. Use them with pumps, filters, regulators, compressors, and in suction and process lines.
- For Use With: Air and Water
- Accuracy: ±1% Mid Scale (Grade A); except
4" Dial Dia.: ±1% Full Scale (Grade 1A)
Available Pressure Ranges | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pressure Range | Vacuum Range | Graduation Marks | Numeric Increments | ||||||
psi | kPa | in. of Hg | kPa | psi | in. of Hg | kPa | psi | in. of Hg | kPa |
1 1/2" Dial Diameter | |||||||||
0 to 15 | 0 to 100 | 30 to 0 | 0 to -100 | 0.5 | 1 | 5 | 5 | 10 | 50 |
0 to 15 | 0 to 100 | 30 to 0 | 0 to -100 | 1 | 1 | 5 | 5 | 10 | 50 |
0 to 30 | 0 to 200 | 30 to 0 | 0 to -100 | 1 | 2 | 5 | 10 | 10 | 50 |
0 to 30 | 0 to 200 | 30 to 0 | 0 to -100 | 1 | 1 | 5 | 10 | 10 | 50 |
0 to 60 | 0 to 400 | 30 to 0 | 0 to -100 | 2 | 2 | 10 | 20 | 30 | 100 |
0 to 60 | 0 to 400 | 30 to 0 | 0 to -100 | 1 | 2 | 10 | 10 | 10 | 100 |
0 to 100 | 0 to 700 | 30 to 0 | 0 to -100 | 2 | 6 | 10 | 20 | 30 | 100 |
0 to 100 | 0 to 700 | 30 to 0 | 0 to -100 | 2 | 5 | 20 | 20 | 30 | 100 |
0 to 150 | 0 to 1,000 | 30 to 0 | 0 to -100 | 2 | 7.5 | 20 | 30 | 30 | 200 |
0 to 150 | 0 to 1,000 | 30 to 0 | 0 to -100 | 2 | 5 | 20 | 20 | 30 | 200 |
0 to 300 | 0 to 2,000 | 30 to 0 | 0 to -100 | 5 | 15 | 50 | 50 | 30 | 500 |
2 1/2" Dial Diameter | |||||||||
0 to 15 | 0 to 100 | 30 to 0 | 0 to -100 | 0.5 | 1 | 5 | 5 | 10 | 50 |
0 to 30 | 0 to 200 | 30 to 0 | 0 to -100 | 1 | 2 | 5 | 10 | 10 | 50 |
0 to 60 | 0 to 400 | 30 to 0 | 0 to -100 | 2 | 2 | 10 | 20 | 30 | 100 |
0 to 100 | 0 to 680 | 30 to 0 | 0 to -100 | 2 | 5 | 10 | 20 | 30 | 200 |
0 to 160 | 0 to 1,100 | 30 to 0 | 0 to -100 | 5 | 10 | 20 | 40 | 30 | 200 |
0 to 200 | 0 to 1,350 | 30 to 0 | 0 to -100 | 5 | 10 | 50 | 50 | 30 | 200 |
0 to 300 | 0 to 2,050 | 30 to 0 | 0 to -100 | 5 | 10 | 50 | 50 | 30 | 500 |
4" Dial Diameter | |||||||||
0 to 15 | 0 to 100 | 30 to 0 | 0 to -100 | 0.5 | 1 | 2 | 3 | 5 | 20 |
0 to 30 | 0 to 205 | 30 to 0 | 0 to -100 | 0.5 | 1 | 5 | 5 | 10 | 50 |
0 to 60 | 0 to 410 | 30 to 0 | 0 to -100 | 2 | 2 | 10 | 10 | 10 | 100 |
0 to 100 | 0 to 680 | 30 to 0 | 0 to -100 | 2 | 5 | 10 | 10 | 30 | 100 |
0 to 160 | 0 to 1,100 | 30 to 0 | 0 to -100 | 5 | 5 | 20 | 20 | 30 | 100 |
0 to 200 | 0 to 1,360 | 30 to 0 | 0 to -100 | 5 | 5 | 20 | 20 | 30 | 200 |
0 to 300 | 0 to 2,050 | 30 to 0 | 0 to -100 | 5 | 10 | 50 | 50 | 30 | 500 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
1 1/2" | 1/8 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 0000000 | 00000 |
4" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
4" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
1 1/2" | 1/8 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 0000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
- For Use With: Air and Water
- Accuracy: ±1.5% Full Scale (Not Graded); except
4" Dial Dia.: ±1% Full Scale (Grade 1A)
Available Pressure and Vacuum Ranges | |||||
---|---|---|---|---|---|
Graduation Marks | Numeric Increments | ||||
Pressure Range, psi | Vacuum Range, in. of Hg | psi | in. of Hg | psi | in. of Hg |
0 to 15 | 30 to 0 | 0.5 | 1 | 5 | 10 |
0 to 30 | 30 to 0 | 1 | 2 | 10 | 30 |
0 to 30 | 30 to 0 | 0.5 | 1 | 5 | 10 |
0 to 60 | 30 to 0 | 2 | 5 | 20 | 30 |
0 to 60 | 30 to 0 | 1 | 2 | 10 | 10 |
0 to 100 | 30 to 0 | 2 | 5 | 20 | 30 |
0 to 160 | 30 to 0 | 2 | 5 | 20 | 30 |
0 to 160 | 30 to 0 | 4 | 10 | 40 | 30 |
0 to 300 | 30 to 0 | 5 | 10 | 50 | 30 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
2 1/2" | 1/4 | -40° to 140° | -40° to 210° | Glycerin | 0000000 | 0000000 |
4" | 1/2 | -40° to 140° | -40° to 210° | Glycerin | 0000000 | 000000 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
2 1/2" | 1/4 | -40° to 140° | -40° to 210° | Glycerin | 0000000 | 0000000 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
---|---|---|---|---|---|---|---|
2 1/2" | 1/4 | -40° to 140° | -40° to 210° | Glycerin | 2 29/64" | 0000000 | 0000000 |
Vibration-Resistant Pressure and Vacuum Gauges




A glycerin-filled dial reduces needle flutter for precise readings in high-vibration applications. Also known as compound gauges, these measure both pressure and vacuum. Use them with pumps, filters, regulators, compressors, and in suction and process lines.
- For Use With: Air
- Accuracy: ±1.5% Full Scale (Not Graded)
Available Pressure and Vacuum Ranges | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pressure Range | Vacuum Range | Graduation Marks | Numeric Increments | ||||||
psi | kPa | in. of Hg | kPa | psi | in. of Hg | kPa | psi | in. of Hg | kPa |
0 to 15 | 0 to 100 | 30 to 0 | 0 to -100 | 0.5 | 1 | 5 | 5 | 10 | 50 |
0 to 30 | 0 to 200 | 30 to 0 | 0 to -100 | 1 | 2 | 10 | 10 | 30 | 100 |
0 to 60 | 0 to 400 | 30 to 0 | 0 to -100 | 2 | 5 | 20 | 20 | 30 | 200 |
0 to 100 | 0 to 680 | 30 to 0 | 0 to -100 | 2 | 5 | 20 | 20 | 30 | 200 |
Vibration- and Corrosion-Resistant Vacuum Gauges



Back Connection
(Panel Mount)



Back Connection
(Panel Mount)





Designed for harsh environments prone to vibration, these gauges pair a corrosion-resistant 304 stainless steel case with a glycerin-filled dial to reduce needle flutter. Use them with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
- For Use With: Air
- Accuracy:
2" Dial Dia.: ±1% Mid Scale (Grade A)
2 1/2" Dial Dia.: ±1.5% Full Scale (Not Graded)
4" Dial Dia.: ±1% Full Scale (Grade 1A)
Available Vacuum Ranges | ||
---|---|---|
Vacuum Range, in. of Hg | Graduation Marks, in. of Hg | Numeric Increments, in. of Hg |
30 to 0 | 0.5 | 5 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
2 1/2" | 1/4 | -40° to 140° | -40° to 210° | Glycerin | 00000000 | 0000000 |
4" | 1/2 | -40° to 140° | -40° to 210° | Glycerin | 00000000 | 000000 |
- For Use With: Air
- Accuracy: ±1% Mid Scale (Grade A); except
4" Dial Dia.: ±1% Full Scale (Grade 1A)
Available Vacuum Ranges | |||||||||
---|---|---|---|---|---|---|---|---|---|
Gauges | Gauges with NIST Certificate | ||||||||
Vacuum Range | Graduation Marks | Numeric Increments | Graduation Marks | Numeric Increments | |||||
in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa |
1 1/2" Dial Diameter | |||||||||
30 to 0 | 0 to -100 | 0.5 | 2 | 5 | 20 | __ | __ | __ | __ |
2 1/2" Dial Diameter | |||||||||
30 to 0 | 0 to -100 | 0.5 | 2 | 5 | 10 | 0.5 | 2 | 5 | 10 |
4" Dial Diameter | |||||||||
30 to 0 | 0 to -100 | 0.5 | 1 | 5 | 10 | 0.5 | 1 | 5 | 10 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
1 1/2" | 1/8 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 00000 |
4" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 000000 |
4" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 000000 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
1 1/2" | 1/8 | 35° to 140° | 35° to 140° | Glycerin | 00000000 | 000000 |
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2 1/2" | 1/4 | 35° to 140° | 35° to 140° | Glycerin | 000000000 | 000000 |
Vibration-Resistant Vacuum Gauges




A glycerin-filled dial reduces needle flutter for precise readings in high-vibration applications. Gauges can be used with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
- For Use With: Air
- Accuracy: ±1.5% Full Scale (Not Graded)
Available Vacuum Ranges | |||||
---|---|---|---|---|---|
Vacuum Range | Graduation Marks | Numeric Increments | |||
in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa |
30 to 0 | 0 to -100 | 0.5 | 2 | 5 | 20 |