Shielding Shielding |
---|
![]() | Unshielded |
![]() | Shielded |
Cable AWG Cable AWG |
---|
Flexibility Flexibility |
---|
![]() | ![]() |
Ultra Flexible | Flexible |
![]() | |
Bend and Stay |
OD OD |
---|

Inner Insulation Color Inner Insulation Color |
---|
![]() | Red | ![]() | Black |
![]() | White | ![]() | Green |
![]() | Blue | ![]() | Brown |
![]() | Yellow | ![]() | Orange |
![]() | Pink | ![]() | Beige |
![]() | Gray | ![]() | Purple |
Current Current |
---|
Wire Finish Wire Finish |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Industry Designation for Cable Insulation
More
About Wire and Cable
More
Low-Voltage Cable

- Use For: Appliances, Vehicles
- Flexible
- Temperature Range: -40° to 175° F
- Insulation: PVC Plastic
Also known as GPT cable, this cable is often used in low-voltage applications such as battery and vehicle wiring and radios. It has one red wire and one black wire to easily identify polarity. The wires can be pulled apart for installation.
Per Ft. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Wd. | Thick. | Outer Insulation Color | Industry Designation | Length, ft. | 1-249 | 250-Up | |
Stranded Wire | ||||||||||
12V DC | ||||||||||
24 | 2 | 24/2 | 0.11" | 0.06" | Black, Red | GPT | 000000 | 00000 | 00000 | |
18 | 2 | 18/2 | 0.21" | 0.1" | Black, Red | GPT | 000000 | 000 | 000 | |
14 | 2 | 14/2 | 0.29" | 0.15" | Black, Red | GPT | 000000 | 000 | 000 | |
12 | 2 | 12/2 | 0.33" | 0.16" | Black, Red | GPT | 000000 | 0000 | 000 | |
10 | 2 | 10/2 | 0.4" | 0.2" | Black, Red | GPT | 000000 | 0000 | 0000 | |
8 | 2 | 8/2 | 0.49" | 0.25" | Black, Red | GPT | 000000 | 0000 | 0000 |
Direct-Burial Cable
- Use For: Buildings, Outdoors
- Flexible
- Temperature Range: 0° to 140° F
Weather-resistant insulation makes this cable suitable for outdoor use and direct burial without conduit.
18-gauge wire is often used for sprinkler systems.
16-, 14-, and 12-gauge wire is designed for underground, low-voltage lighting equipment, such as landscape lighting. The wires can be separated for installation.

Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Material | Inner Insulation Color | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | 500 ft. | |
30V AC/30V DC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18 | 2 | 18/2 | 0.2" | Black | Polypropylene Plastic | Red, White | UL Listed | 0000000 | ||||||
18 | 3 | 18/3 | 0.21" | Black | Polypropylene Plastic | Green, Red, White | UL Listed | 0000000 | ||||||
18 | 4 | 18/4 | 0.23" | Black | Polypropylene Plastic | Blue, Green, Red, White | UL Listed | 0000000 | ||||||
18 | 5 | 18/5 | 0.25" | Black | Polypropylene Plastic | Blue, Green, Red, White, Yellow | UL Listed | 0000000 | ||||||
18 | 6 | 18/6 | 0.27" | Black | Polypropylene Plastic | Blue, Brown, Green, Red, White, Yellow | UL Listed | 0000000 | ||||||
18 | 7 | 18/7 | 0.27" | Black | Polypropylene Plastic | Blue, Brown, Green, Orange, Red, White, Yellow | UL Listed | 0000000 | ||||||
18 | 8 | 18/8 | 0.29" | Black | Polypropylene Plastic | Black, Blue, Brown, Green, Orange, Red, White, Yellow | UL Listed | 0000000 | ||||||
18 | 9 | 18/9 | 0.31" | Black | Polypropylene Plastic | Black, Blue, Brown, Green, Orange, Pink, Red, White, Yellow | UL Listed | 0000000 |
Riser-Rated Communication and Security System Cable


- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
This cable is designated CL3R and CMR, so it has flame-resistant insulation and is approved for use in low-circuit circuits in vertical shafts and large facilities with multiple levels. It’s often used in intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
22 | 6 | 22/6 | 0.16" | Gray | Black, Blue, Brown, Green, Red, White | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 8 | 22/8 | 0.17" | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 12 | 22/12 | 0.25" | Gray | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 2 | 18/2 | 0.18" | Gray | Black, Red | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 3 | 18/3 | 0.15" | Gray | Black, Red, White | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.18" | Gray | Black, Green, Red, White | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.21" | Gray | Black, Blue, Brown, Green, Red, White | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 2 | 16/2 | 0.16" | Gray | Black, Red | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 4 | 16/4 | 0.2" | Gray | Black, Green, Red, White | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
14 | 2 | 14/2 | 0.21" | Gray | Black, Red | __ | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
22 | 2 | 22/2 | 0.13" | Gray | Black, Red | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 4 | 22/4 | 0.15" | Gray | Black, Green, Red, White | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 8 | 22/8 | 0.21" | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 2 | 18/2 | 0.15" | Gray | Black, Red | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 3 | 18/3 | 0.19" | Gray | Black, Red, White | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.2" | Gray | Black, Green, Red, White | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.23" | Gray | Black, Blue, Brown, Green, Red, White | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 2 | 16/2 | 0.19" | Gray | Black, Red | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 4 | 16/4 | 0.22" | Gray | Black, Green, Red, White | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 | |||||
14 | 2 | 14/2 | 0.22" | Gray | Black, Red | Uninsulated Ground Wire | CMR, CL3R | ETL Listed, C-ETL Listed | 0000000 |
Duct-Rated Communication and Security System Cable


- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 165° F
- Insulation: PVC Plastic
Also known as plenum cable, this cable is designated CL3P and CMP, so it has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it in low-current circuits such as intercoms, speakers, and security systems.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
22 | 2 | 22/2 | 0.11" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 4 | 22/4 | 0.13" | White | Black, Green, Red, White | __ | CMP, CL3P | UL Listed, C-UL Listed | 0000000 | |||||
22 | 6 | 22/6 | 0.16" | White | Black, Blue, Brown, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 8 | 22/8 | 0.17" | White | Black, Blue, Brown, Green, Orange, Red, White, Yellow | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 12 | 22/12 | 0.21" | White | Beige, Black, Blue, Brown, Gray, Green, Orange, Pink, Purple, Red, White, Yellow | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 2 | 18/2 | 0.14" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 3 | 18/3 | 0.15" | White | Black, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.17" | White | Black, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.21" | White | Black, Blue, Brown, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 2 | 16/2 | 0.16" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 4 | 16/4 | 0.2" | White | Black, Green, Red, White | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
14 | 2 | 14/2 | 0.21" | White | Black, Red | __ | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
Shielded Stranded Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
22 | 2 | 22/2 | 0.14" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 4 | 22/4 | 0.15" | White | Black, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
22 | 8 | 22/8 | 0.21" | White | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 2 | 18/2 | 0.16" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 3 | 18/3 | 0.19" | White | Black, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.2" | White | Black, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.23" | White | Black, Blue, Brown, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 2 | 16/2 | 0.19" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
16 | 4 | 16/4 | 0.22" | White | Black, Green, Red, White | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 | |||||
14 | 2 | 14/2 | 0.22" | White | Black, Red | Uninsulated Ground Wire | CMP, CL3P | ETL Listed, C-ETL Listed | 0000000 |
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Use unshielded cable in applications where signal interference is not a concern.

- Use For: Buildings
- Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
Coiled Communication Cable

- Use For: Buildings, Outdoors
- Ultra Flexible
- Temperature Range: -40° to 140° F
- Insulation: Neoprene Rubber
After extending to full length to provide added reach, this cable retracts and self-coils for tangle-free storage. It's often used with microphones, headsets, and other types of low-circuit communication equipment.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Coil OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 2 ft. Retracted Lg. | 4 ft. Retracted Lg. | |
Stranded Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
300V AC | |||||||||||
23 | 2 | 23/2 | 1 A @ 86° F | 0.22" | 3/4" | Black | Black, White | UL Listed | 00000000 | ||
23 | 3 | 23/3 | 1 A @ 86° F | 0.22" | 3/4" | Black | Black, Red, White | UL Listed | 00000000 | ||
23 | 4 | 23/4 | 1 A @ 86° F | 0.25" | 0.88" | Black | Black, Green, Red, White | UL Listed | 00000000 | ||
23 | 6 | 23/6 | 1 A @ 86° F | 0.31" | 1.13" | Black | Black, Blue, Green, Red, White, Yellow | UL Listed | 00000000 |
Thermostat Cable

- Use For: Buildings
- Bend and Stay
- Temperature Range: 0° to 140° F
- Insulation:
Outer: PVC Plastic
Inner: Polyethylene Plastic
Hook up thermostats, air-conditioning units, and other low-voltage equipment. This cable is designated CL2 so it has flame-resistant insulation. The wires are solid so it stays in the shape you bend it.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Solid Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
150V AC/150V DC | |||||||||||||
20 | 2 | 20/2 | 0.11" | Brown | Red, White | CL2 | ETL Listed | 0000000 | |||||
20 | 3 | 20/3 | 0.12" | Brown | Green, Red, White | CL2 | ETL Listed | 0000000 | |||||
20 | 4 | 20/4 | 0.13" | Brown | Blue, Green, Red, White | CL2 | ETL Listed | 0000000 | |||||
20 | 5 | 20/5 | 0.15" | Brown | Blue, Green, Red, White, Yellow | CL2 | ETL Listed | 0000000 | |||||
20 | 6 | 20/6 | 0.16" | Brown | Blue, Brown, Green, Red, White, Yellow | CL2 | ETL Listed | 0000000 | |||||
20 | 8 | 20/8 | 0.17" | Brown | Black, Blue, Brown, Green, Orange, Red, White, Yellow | CL2 | ETL Listed | 0000000 | |||||
18 | 2 | 18/2 | 0.13" | Brown | Red, White | CL2 | ETL Listed | 0000000 | |||||
18 | 3 | 18/3 | 0.14" | Brown | Green, Red, White | CL2 | ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.15" | Brown | Blue, Green, Red, White | CL2 | ETL Listed | 0000000 | |||||
18 | 5 | 18/5 | 0.17" | Brown | Blue, Green, Red, White, Yellow | CL2 | ETL Listed | 0000000 | |||||
18 | 6 | 18/6 | 0.19" | Brown | Blue, Brown, Green, Red, White, Yellow | CL2 | ETL Listed | 0000000 | |||||
18 | 8 | 18/8 | 0.2" | Brown | Black, Blue, Brown, Green, Orange, Red, White, Yellow | CL2 | ETL Listed | 0000000 |
Riser-Rated Fire Alarm Cable


- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range: 0° to 140° F
- Insulation: PVC Plastic
This FPLR cable is approved for use in vertical shafts and large facilities with multiple levels. It has flame-resistant insulation for use in critical circuits such as fire alarm systems and smoke detectors.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
18 | 2 | 18/2 | 0.13" | Red | Black, Red | __ | FPLR | ETL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.15" | Red | Black, Green, Red, Yellow | __ | FPLR | ETL Listed | 0000000 | |||||
Shielded Solid Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
18 | 2 | 18/2 | 0.15" | Red | Black, Red | Uninsulated Ground Wire | FPLR | ETL Listed | 0000000 |
Duct-Rated Fire Alarm Cable


- Use For:
Unshielded: Buildings
Shielded: Buildings, Interference Shielding - Flexible
- Temperature Range:
Unshielded: 0° to 165° F
Shielded: 32° to 165° F - Insulation: PVC Plastic
Also known as plenum cable, this FPLP cable has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The insulation is also flame resistant for use in critical circuits such as fire alarm systems and smoke detectors.
Use unshielded cable in applications where signal interference is not a concern.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Unshielded Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
300V AC/300V DC | ||||||||||||||
18 | 2 | 18/2 | 0.15" | Red | Black, Red | __ | FPLP | UL Listed | 0000000 | |||||
18 | 4 | 18/4 | 0.18" | Red | Black, Green, Red, Yellow | __ | FPLP | UL Listed | 0000000 | |||||
Shielded Solid Wire | ||||||||||||||
300V AC/300V DC | ||||||||||||||
18 | 2 | 18/2 | 0.16" | Red | Black, Red | Uninsulated Ground Wire | FPLP | UL Listed | 0000000 |
Audio Cable

- Use For: Audio, Buildings
- Flexible
- Temperature Range: See table
- Outer Insulation Material: PVC Plastic
Hook up speakers, intercoms, and other low-current devices to a building's communication wiring. This CL2 cable is suitable for in-wall installation in single-level facilities. The wires can be separated for installation. All cable has one wire marked for polarity, except for 0.17-in.-wide cable.
Wire Ga. | No. of Wires | Cable AWG | Temperature Range | Wd. | Thick. | Outer Insulation Color | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
CL2 Stranded Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
150V AC/150V DC | |||||||||||||
14 | 2 | 14/2 | 0° to 140° F | 0.38" | 0.18" | Clear | ETL Listed, C-ETL Listed | 0000000 | |||||
12 | 2 | 12/2 | 0° to 140° F | 0.41" | 0.19" | Clear | ETL Listed, C-ETL Listed | 0000000 | |||||
300V DC | |||||||||||||
22 | 2 | 22/2 | 0° to 220° F | 0.14" | 0.07" | Black | __ | 0000000 | |||||
18 | 2 | 18/2 | 0° to 220° F | 0.17" | 0.09" | Clear | __ | 0000000 |
Battery Wire

- Use for vehicles
- 60V DC Wire: Flexible
600V AC/DC: Ultra Flexible - Temperature Range: -40° to 190° F
Connect batteries in vehicles and generators.
Strand count is the number of strands followed by the size of the individual strand.
Wire with a PVC plastic insulation resists fuel and oil.
SAE J1128 and SAE J1127 wire meet standards for low-voltage wiring in vehicle electrical systems.
Per Ft. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Specifications Met | Choose an Outer Insulation Color | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with PVC Plastic Insulation | |||||||||
60V DC | |||||||||
8 | 19/21 | 57 A @ 86° F | 0.22" | SAE J1128 | 0000000 | 00000 | 00000 | ||
6 | 48/22.5 | 82 A @ 86° F | 0.33" | SAE J1127 | 0000000 | 0000 | 0000 | ||
4 | 70/22.5 | 110 A @ 86° F | 0.38" | SAE J1127 | 0000000 | 0000 | 0000 | ||
2 | 64/20 | 147 A @ 86° F | 0.45" | SAE J1127 | 0000000 | 0000 | 0000 | ||
1 | 133/22 | 172 A @ 86° F | 0.49" | SAE J1127 | 0000000 | 0000 | 0000 | ||
1/0 | 210/23 | 200 A @ 86° F | 0.55" | SAE J1127 | 0000000 | 0000 | 0000 | ||
2/0 | 133/20 | 233 A @ 86° F | 0.61" | SAE J1127 | 0000000 | 00000 | 0000 | ||
3/0 | 259/22 | 270 A @ 86° F | 0.66" | SAE J1127 | 0000000 | 00000 | 00000 | ||
4/0 | 418/23 | 315 A @ 86° F | 0.73" | SAE J1127 | 0000000 | 00000 | 00000 |
Deutsch-Style Power Cords


Use these cords in vehicles and other agricultural and construction equipment. The industry designation is SOOW, so the inner and outer insulation resists oil.
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | Lg., ft. | Current, A | Wire Gauge | OD | Insulation Material | Industry Designation | Temp. Range, °F | Color | Each | |
Plug × Socket | ||||||||||
2 | 6 | 25 | 14 | 0.51" | Rubber | SOOW | -40° to 190° | Black | 0000000 | 000000 |
2 | 12 | 25 | 14 | 0.51" | Rubber | SOOW | -40° to 190° | Black | 0000000 | 00000 |
4 | 6 | 25 | 14 | 0.58" | Rubber | SOOW | -40° to 190° | Black | 0000000 | 00000 |
4 | 12 | 25 | 14 | 0.58" | Rubber | SOOW | -40° to 190° | Black | 0000000 | 000000 |