Industry Designation Industry Designation | Show |
---|
|
Industry Designation Industry Designation | Hide |
---|
Wire Type Wire Type |
---|
![]() | Solid |
Use For Use For |
---|
|
System of Measurement System of Measurement |
---|
|
Outer Insulation Material Outer Insulation Material |
---|
|
Flexibility Flexibility |
---|
![]() | Flexible |
Wire Material Wire Material |
---|
|
Voltage Voltage |
---|
|
Current Current |
---|
|
Environmental Rating Environmental Rating |
---|
Environment Environment |
---|
|
Wire Finish Wire Finish |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Inner Insulation Marking Inner Insulation Marking |
---|
|
Inner Insulation Material Inner Insulation Material |
---|
|
Shielding Shielding |
---|
![]() | Unshielded |
Specifications Met Specifications Met |
---|
|
More
Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the THHN building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has an insulated ground wire that is not counted in the cable AWG.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Industry Designation | Environmental Rating | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||||
14 | 3 | 14/2 | 15 A @ 86° F | 0.44" | Black, Green, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL Listed, UL 1569, Flame Rated VW-1 | 0000000 | |||||
14 | 4 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL Listed, UL 1569, Flame Rated VW-1 | 0000000 | |||||
14 | 5 | 14/4 | 15 A @ 86° F | 0.49" | Black, Blue, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL Listed, UL 1569, Flame Rated VW-1 | 0000000 | |||||
12 | 3 | 12/2 | 20 A @ 86° F | 0.48" | Black, Green, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL Listed, UL 1569, Flame Rated VW-1 | 0000000 | |||||
12 | 4 | 12/3 | 20 A @ 86° F | 0.51" | Black, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL Listed, UL 1569, Flame Rated VW-1 | 0000000 | |||||
12 | 5 | 12/4 | 20 A @ 86° F | 0.54" | Black, Blue, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL Listed, UL 1569, Flame Rated VW-1 | 0000000 | |||||
10 | 3 | 10/2 | 30 A @ 86° F | 0.54" | Black, Green, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL Listed, UL 1569, Flame Rated VW-1 | 0000000 | |||||
10 | 4 | 10/3 | 30 A @ 86° F | 0.58" | Black, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL Listed, UL 1569, Flame Rated VW-1 | 0000000 | |||||
10 | 5 | 10/4 | 30 A @ 86° F | 0.62" | Black, Blue, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL Listed, UL 1569, Flame Rated VW-1 | 0000000 |