Filter by
Display Type
Electrical Safety Rating
DC Voltage
DFARS Specialty Metals
Analog Display Type
Insulation Testers
Insulation Testers
| Batteries | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Display Type | Electrical Safety Rating | Measures | Max. Resistance, Mohm | Resistance Accuracy | DC Voltage Insulation Testing Selections, V DC | AC Voltage, V AC | DC Voltage, V DC | Display Count | Includes | Included | Size | No. Required | Each | ||
| Digital | CAT IV, 600V | Resistance, AC Voltage, DC Voltage | 4,000 | 4% | 250; 500; 1,000 | 0 to 600 | 0 to 1,000 | 4,000 | Alligator Clips, Carrying Case, Probe Tip, Test Leads | Yes | AA | 6 | 0000000 | 0000000 | |
| Analog | CAT III, 1,000V | Resistance, AC Voltage | 400 | 3% | 250; 500; 1,000 | 0 to 600 | — | — | Carrying Case, Hanging Strap, Test Leads | Yes | AA | 6 | 0000000 | 000000 | |
| Light Indicator | — | Resistance, AC Voltage | 1,000 | 1% | — | — | — | — | Carrying Case, Test Leads | No | C | 2 | 0000000 | 000000 | |
Megger Insulation Testers
|  |  | 
| Model Number MIT310 Digital Display | Model Number MIT410/2, Digital Display | 
| Batteries | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mfr. Model No. | Display Type | Electrical Safety Rating | Measures | Max. Resistance | Resistance Accuracy | DC Voltage Insulation Testing Selections, V DC | AC Voltage, V AC | DC Voltage, V DC | Display Count | Enclosure Rating | Includes | Included | Size | No. Required | Each | ||
| MIT310 | Digital | CAT III, 600V | Resistance, AC Voltage, DC Voltage | 999 Mohm | 3% | 250; 500; 1,000 | 0 to 600 | 0 to 600 | 1,000 | IP54 | Alligator Clips, Carrying Case, Test Leads | Yes | AA | 8 | 00000000 | 0000000 | |
| MIT410/2 | Digital | CAT III, 1,000V; CAT IV, 600V | Resistance, AC Voltage, DC Voltage | 200 Gohm | 2% | 50; 100; 250; 500; 1,000 | 0 to 600 | 0 to 600 | 1,000 | IP54 | Alligator Clips, Carrying Case, Probe Tips, Test Leads | Yes | AA | 6 | 00000000 | 00000000 | |
Hand Crank-Operated Insulation Testers
Insulation Testers
| Display Type | Electrical Safety Rating | Measures | Max. Resistance, Mohm | Resistance Accuracy | DC Voltage Insulation Testing Selections, V DC | AC Voltage, V AC | Enclosure Rating | Includes | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Analog | CAT III, 300V | Resistance, AC Voltage, DC Voltage | 5,000 | 2.5% | 250; 500; 1,000 | 0 to 600 | IP52 | Alligator Clips, Carrying Case, Probe Tip, Test Leads | 0000000 | 0000000 | 
Megger Insulation Testers
| Mfr. Model No. | Display Type | Electrical Safety Rating | Measures | Max. Resistance, Mohm | Resistance Accuracy | DC Voltage Insulation Testing Selections, V DC | AC Voltage, V AC | Includes | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| MJ159 | Analog | CAT II, 300V | Resistance, AC Voltage, DC Voltage | 2,000 | 1.25% | 100; 250; 500; 1,000 | 0 to 600 | Alligator Clips, Carrying Case, Probe Tips, Test Leads | 0000000 | 000000000 | 
Insulation Testers for Hand Tools
| Certificate Type | Display Type | Measures | Current Leak Detection, mA | Accuracy | Insulation Testing Selection AC Voltage, V AC | Insulation Testing Selection DC Voltage, V DC | Tool Connection End Type | Tool Connection No. of Blades | Certification | Includes | Input AC Voltage, V AC | Freq., Hz | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Calibration Certificate | Digital | Resistance, AC Voltage, Continuity, DC Voltage | 0 to 10 | 1% | 10 to 5,000 | 20 to 5,000 | Receptacle | 3 | CE Marked | Alligator Test Leads, Ground Clip, High-Voltage Probe | 105 to 265 | 50 | 0000000 | 000000000 | 