For Use With For Use With |
---|
|
Thread Type Thread Type |
---|
|
Connection Type Connection Type | Show |
---|
|
Connection Type Connection Type | Hide |
---|
Mounting Orientation Mounting Orientation |
---|
|
Float Material Float Material |
---|
|
Body Material Body Material |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
|
|
Switch Starting Position Switch Starting Position |
---|
|
Mount Type Mount Type |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
|
System of Measurement System of Measurement |
---|
|
Insertion Depth Insertion Depth |
---|
|
|
|
Current Current |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Number of Circuits Controlled Number ofCircuits Controlled |
---|
|
Environment Environment |
---|
|
More
Install these switches into a threaded connection in your tank wall from outside the tank. They activate process equipment such as pumps or motors when the diesel fuel, hydraulic fluid, or oil level in your tank reaches the float. Choose switches with a metal body for durability in harsh conditions.
For technical drawings and 3-D models, click on a part number.
Pipe | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Electrical Connection | Trade Size | Thread Type | Gender | Each | ||
120V AC/240V AC Input Voltage | |||||||||||||||||
Polybutylene Plastic Body | |||||||||||||||||
A | 1/2 | NPT | Male | 0.85 | 100 psi @ 70° F | -40° to 145° | 2 3/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.28 A @ 120 V AC | Polybutylene Plastic | Wire Leads | 1/2 | NPT | Male | 00000000 | 000000 |
316 Stainless Steel Body | |||||||||||||||||
D | 1/2 | NPT | Male | 0.55 | 100 psi @ 70° F | -40° to 225° | 3 11/16" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.17 A @ 120 V AC | Polypropylene Plastic | Wire Leads | 1/2 | NPT | Male | 00000000 | 000000 |
D | 1/2 | NPT | Male | 0.65 | 100 psi @ 70° F | -40° to 250° | 3 11/16" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.17 A @ 120 V AC | Nylon Plastic | Wire Leads | 1/2 | NPT | Male | 0000000 | 000000 |
E | 1 | NPT | Male | 0.85 | 500 psi @ 70° F | -40° to 300° | 5 5/16" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.17 A @ 120 V AC | 304 Stainless Steel | Wire Leads | 1/2 | NPT | Male | 00000000 | 000000 |
F | 1 | NPT | Male | 0.9 | 900 psi @ 70° F | -40° to 300° | 4 1/8" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.17 A @ 120 V AC | 316 Stainless Steel | Wire Leads | 1/2 | NPT | Male | 00000000 | 000000 |
Brass Body | |||||||||||||||||
E | 1 | NPT | Male | 0.8 | 150 psi @ 70° F | -40° to 180° | 3 7/8" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.17 A @ 120 V AC | Buna-N Rubber | Wire Leads | 1/2 | NPT | Male | 0000000 | 000000 |
For use in locations with flammable gases and combustible dust, this switch is UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount it vertically through the top of your tank. It’s rated NEMA 4 for protection from washdowns.
For technical drawings and 3-D models, click on a part number.
Pipe | Float | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Lg. | Dia. | Electrical Connection | Trade Size | Thread Type | Gender | Each | |
120V AC/240V AC Input Voltage | ||||||||||||||||||
316 Stainless Steel Body | ||||||||||||||||||
1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 35° to 275° | 8 11/16" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 10 A @ 120 V AC | 316 Stainless Steel | 4 1/2" | 1 5/8" | Wire Leads | 3/4 | NPT | Female | 0000000 | 0000000 |
Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall. All are rated NEMA 4 for protection from washdowns. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” (normally open) or from “on” to “off” (normally closed).
Switches with stainless steel body are more corrosion resistant than switches with brass body.
For technical drawings and 3-D models, click on a part number.
Pipe | Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Current | Float Material | Trade Size | Thread Type | Gender | Environmental Rating | Each | |
120V AC/240V AC Input Voltage | |||||||||||||||
Brass Body | |||||||||||||||
A | 1 | NPT | Male | 0.7 | 350 psi @ 70° F | 0° to 220° | 1 3/4" | 5 A @ 120 V AC | 304 Stainless Steel | 3/4 | NPT | Male | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 | 0000000 | 0000000 |
A | 1 | NPT | Male | 0.9 | 1,000 psi @ 70° F | 0° to 220° | 1 3/4" | 5 A @ 120 V AC | Polypropylene Plastic | 3/4 | NPT | Male | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 | 0000000 | 000000 |
B | 1 | NPT | Male | 0.5 | 200 psi @ 70° F | 0° to 220° | 2 7/8" | 5 A @ 120 V AC | 304 Stainless Steel | 3/4 | NPT | Male | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 | 0000000 | 000000 |
C | 1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 0° to 275° | 13 3/16" | 10 A @ 120 V AC | 316 Stainless Steel | 3/4 | NPT | Female | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G IP56 NEMA 4 | 0000000 | 000000 |
303 Stainless Steel Body | |||||||||||||||
A | 1 | NPT | Male | 0.9 | 2,000 psi @ 70° F | 0° to 220° | 1 3/4" | 5 A @ 120 V AC | Polypropylene Plastic | 3/4 | NPT | Male | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 | 0000000 | 000000 |
B | 1 | NPT | Male | 0.5 | 200 psi @ 70° F | 0° to 220° | 2 7/8" | 5 A @ 120 V AC | 304 Stainless Steel | 3/4 | NPT | Male | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4 | 0000000 | 000000 |
316 Stainless Steel Body | |||||||||||||||
C | 1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 0° to 275° | 13 3/16" | 10 A @ 120 V AC | 316 Stainless Steel | 3/4 | NPT | Female | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G IP56 NEMA 4 | 0000000 | 000000 |
For use in locations with flammable gases and combustible dust, this switch is UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount it vertically through the top of your tank. It’s rated NEMA 4 for protection from washdowns.
For technical drawings and 3-D models, click on a part number.
Pipe | Float | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Lg. | Dia. | Electrical Connection | Trade Size | Thread Type | Gender | Each | |
120V AC/240V AC Input Voltage | ||||||||||||||||||
Brass Body | ||||||||||||||||||
1 1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 35° to 275° | 8 11/16" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 10 A @ 120 V AC | 316 Stainless Steel | 4 1/2" | 1 5/8" | Wire Leads | 3/4 | NPT | Female | 0000000 | 0000000 |
When dry material rises to the level of the rotating paddle, these switches actuate. All are rated NEMA 4X and IP66 for protection from corrosion and washdowns.
Switches with auxiliary SPDT relay activate an alarm (not included).
For technical drawings and 3-D models, click on a part number.
Paddle | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Current | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Paddle Speed, rpm | Lg. | Wd. | Features | Specifications Met | Each | |
Horizontal Side Mount—0-30 lbs. per cu. ft. Capacity | ||||||||||||
8 A @ 120 V AC | 30 psi @ 70° F | -40° to 110° | 6 5/8" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 | 7" | 2" | Auxiliary SPDT Relay LED Alarm Status Indicator LED Power Indicator | UL Listed C-UL Listed | 00000000 | 0000000 |
20 A @ 120 V AC | 30 psi @ 70° F | -40° to 110° | 6 5/8" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 | 7" | 2" | __ | UL Listed C-UL Listed | 00000000 | 000000 |
Vertical Top Mount—30-70 lbs. per cu. ft. Capacity | ||||||||||||
8 A @ 120 V AC | 30 psi @ 70° F | -40° to 110° | 12" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 | 5" | 1 1/2" | Auxiliary SPDT Relay LED Alarm Status Indicator LED Power Indicator | UL Listed C-UL Listed | 00000000 | 000000 |
20 A @ 120 V AC | 30 psi @ 70° F | -40° to 110° | 12" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 | 5" | 1 1/2" | __ | UL Listed C-UL Listed | 00000000 | 000000 |
Paddle Material | Each | |
316 Stainless Steel | 00000000 | 000000 |
Voltage | Includes | Each | |
120V AC | Bracket, Washer | 00000000 | 0000000 |
Use high-frequency sound waves to detect chemical level. This switch has three relays that can be programmed for multiple set points. Use it to activate several alarms or to automate tank filling and emptying. It’s rated NEMA 4X for protection from corrosion and washdowns.
For technical drawings and 3-D models, click on a part number.
Pipe | Conduit | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Sensing Distance, ft. | Max. Pressure | Temp. Range, °F | Switch Starting Position | Industry Designation | Current | Lg. | Wd. | Electrical Connection | Trade Size | Thread Type | Gender | Each | |
95V AC/250V AC Input Voltage | ||||||||||||||||
Polycarbonate Plastic Body | ||||||||||||||||
1 | NPT | Male | 0.33-9.8 | 30 psi @ 70° F | -5° to 140° | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0.5 A @ 120 V AC | 3 15/16" | 5 3/16" | Screw Terminals | 1/2 | NPT | Female | 0000000 | 0000000 |
Install these switches into a threaded connection in your tank wall from outside the tank. They activate process equipment such as pumps or motors when the water level in your tank reaches the float. Choose switches with a metal body for durability in harsh conditions.
For technical drawings and 3-D models, click on a part number.
Pipe | Conduit | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Electrical Connection | Trade Size | Thread Type | Gender | Each | |
120V AC Input Voltage | ||||||||||||||||
PPS Plastic Body | ||||||||||||||||
1 | NPT | Male | 0.6 | 150 psi @ 70° F | 40° to 210° | 4 3/4" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 1 A @ 120 V AC | PPS Plastic | Wire Leads | 1/2 | NPT | Male | 00000000 | 000000 |
303 Stainless Steel Body | ||||||||||||||||
1 | NPT | Male | 0.7 | 350 psi @ 70° F | 40° to 200° | 1 3/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.5 A @ 120 V AC | 304 Stainless Steel | Wire Leads | 1/8 | NPT | Male | 00000000 | 000000 |
Brass Body | ||||||||||||||||
1 | NPT | Male | 0.9 | 1,000 psi @ 70° F | 40° to 200° | 1 3/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.5 A @ 120 V AC | Polypropylene Plastic | Wire Leads | 1/8 | NPT | Male | 00000000 | 000000 |
120V AC/240V AC Input Voltage | ||||||||||||||||
PPS Plastic Body | ||||||||||||||||
1 | NPT | Male | 0.6 | 150 psi @ 70° F | 40° to 210° | 4 3/4" | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 5 A @ 120 V AC | PPS Plastic | Wire Leads | 1/2 | NPT | Male | 00000000 | 00000 |
Install these switches into a threaded connection in your tank wall from outside the tank. They activate process equipment such as pumps or motors when the chemical level in your tank reaches the float.
Switches with splash guard minimize false switch activation caused by splashing liquid.
For technical drawings and 3-D models, click on a part number.
Pipe | Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Trade Size | Thread Type | Gender | Each | |
120V AC/240V AC Input Voltage | |||||||||||||||
PVDF Plastic Body | |||||||||||||||
1/2 | NPT | Male | 0.85 | 100 psi @ 70° F | -40° to 220° | 2 3/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.28 A @ 120 V AC | PVDF Plastic | 1/2 | NPT | Male | 0000000 | 000000 |
PVDF Plastic Body with Splash Guard | |||||||||||||||
1 | NPT | Male | 0.85 | 100 psi @ 70° F | -40° to 220° | 1 7/8" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.28 A @ 120 V AC | PVDF Plastic | 1/2 | NPT | Male | 0000000 | 00000 |
Polypropylene Plastic Body | |||||||||||||||
1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | -40° to 220° | 2 3/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.28 A @ 120 V AC | Polypropylene Plastic | 1/4 | NPT | Male | 00000000 | 00000 |
Polypropylene Plastic Body with Splash Guard | |||||||||||||||
1 | NPT | Male | 0.7 | 100 psi @ 70° F | -40° to 220° | 1 7/8" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.28 A @ 120 V AC | Polypropylene Plastic | 1/2 | NPT | Male | 00000000 | 00000 |
Install these switches into a threaded connection in your tank wall from outside the tank. Often used in food-processing applications, they meet NSF/ANSI Standard 169.
For technical drawings and 3-D models, click on a part number.
Pipe | Conduit | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Electrical Connection | Trade Size | Thread Type | Gender | Each | |
120V AC/240V AC Input Voltage | ||||||||||||||||
Polypropylene Plastic Body | ||||||||||||||||
1/2 | NPT | Male | 0.7 | 100 psi @ 70° F | 35° to 220° | 2 3/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.28 A @ 120 V AC | Polypropylene Plastic | Wire Leads | 1/2 | NPT | Male | 00000000 | 000000 |
Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall.
Style A meets Class I, Divisions 1 and 2, Groups A, B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2.
Style B meets Class I, Divisions 1 and 2, Groups C and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2.
For technical drawings and 3-D models, click on a part number.
Pipe | Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Size | Thread Type | Gender | Min. Specific Gravity | Max. Pressure | Temp. Range, °F | Insertion Dp. | Switch Starting Position | Industry Designation | Current | Float Material | Electrical Connection | Trade Size | Thread Type | Gender | Each | |
120V AC/240V AC Input Voltage | |||||||||||||||||
316 Stainless Steel Body | |||||||||||||||||
A | 1/2 | NPT | Male | 0.7 | 300 psi @ 70° F | 0° to 390° | 4 5/8" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.28 A @ 120 V AC | 316 Stainless Steel | Wire Leads | 1/4 | NPT | Male | 00000000 | 0000000 |
A | 1/2 | NPT | Male | 0.7 | 300 psi @ 70° F | 0° to 390° | 4 5/8" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.28 A @ 120 V AC | 316 Stainless Steel | Wire Leads | 1/2 | NPT | Male | 00000000 | 000000 |
A | 1 | NPT | Male | 0.7 | 300 psi @ 70° F | 0° to 390° | 4 5/8" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.28 A @ 120 V AC | 316 Stainless Steel | Wire Leads | 1/2 | NPT | Male | 00000000 | 000000 |
B | 1 1/2 | NPT | Male | 0.4 | 1,500 psi @ 70° F | 0° to 300° | 3 1/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.83 A @ 120 V AC | 316 Stainless Steel | Wire Leads | 1/2 | NPT | Male | 0000000 | 000000 |
B | 2 | NPT | Male | 0.4 | 1,500 psi @ 70° F | 0° to 300° | 3 1/4" | 1 Off (Normally Open)/1 On (Normally Closed) | SPST-NO SPST-NC | 0.83 A @ 120 V AC | 316 Stainless Steel | Wire Leads | 1/2 | NPT | Male | 0000000 | 000000 |
Get NEMA 4 and IP66 protection from dirt and water. Switch is rated for hazardous locations for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. If vibration or shock exceeds a set activation point, the contacts actuate to either shut down your machine or activate an alarm. Reset the switch with the push of a button. The activation point is adjustable between 0 to 5 gravity units (g) at 0 to 60 Hz.
Activation Point | Switching | Conduit | Mounting Slot | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range, g | Frequency Range, Hz | Current, A | Voltage | Temp. Range, °F | Trade Size | Thread Type | Gender | Mounting Fasteners Included | Number of Mounting Holes | Lg. | Wd. | Environmental Rating | Each | |
1 Off (Normally Open) or 1 On (Normally Closed) Switch Starting Position | ||||||||||||||
SPDT | ||||||||||||||
0-5 | 0-60 | 15 | 125V AC 480V AC | -40° to 155° | 3/4 | NPT | Female | No | 4 | 3/4" | 3/8" | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G IP66 NEMA 4 | 0000000 | 0000000 |
Set to a specific speed to detect unwanted machinery slowdown that can cause damage and downtime. Applications include drive trains, power-driven components, and conveyors. Switches are UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. They have an explosion-proof housing and are also rated NEMA 4X for washdown and corrosion protection.
Switching | Input | Conduit | Mounting Slot | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Activation Point Range, rpm | Current, A | Voltage | Voltage | Frequency, Hz | No. of Terminals | Trade Size | Thread Type | Gender | Lg. | Wd. | No. of | Mounting Fasteners Included | Specifications Met | Each | |
1 Off (Normally Open), 1 On (Normally Closed) Starting Switch Position | |||||||||||||||
SPDT | |||||||||||||||
5-100 | 5 | 120V AC | 120V AC | 60 | 5 | 1 | NPT | Female | 1 1/4" | 0.32" | 2 | Yes | UL Listed, C-UL Listed, CE Marked | 0000000 | 0000000 |