For Use With For Use With |
---|
Body Material Body Material |
---|
|
Connection Style Connection Style |
---|
![]() | ![]() |
Threaded | Quick Clamp |
![]() | ![]() |
Flanged | Solder Connect |
![]() | |
Socket Weld |
Valve Function Valve Function |
---|
|
Valve Starting Position Valve Starting Position |
---|
|
Ball Material Ball Material |
---|
|
Maximum Pressure Maximum Pressure |
---|
|
Seal Material Seal Material |
---|
|
Flow Coefficient (Cv) Flow Coefficient (Cv) |
---|
Mounting Orientation Mounting Orientation |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
More
Also known as actuated ball valves, these have a motor that can handle high flow rates and pressures. All operate on electricity to automatically start and stop flow. Valves can be wired as normally closed unless actuated or normally open unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages.
316 stainless steel valves are more corrosion resistant than brass valves.
Full-port valves do not restrict flow. Standard-port valves slightly restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Port Type | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Each | |
Brass Body with Screw Terminals | ||||||||||||||
Normally Open or Normally Closed—120V AC | ||||||||||||||
1/2 | Female | NPTF | Full | 12 | 720 psi @ 150° F | 150 psi @ 366° F | Zero Pressure Drop | 6 | -50° to 450° | 2 15/16" | 6 1/4" | 8 7/8" | 00000000 | 0000000 |
3/4 | Female | NPTF | Full | 32 | 720 psi @ 150° F | 150 psi @ 366° F | Zero Pressure Drop | 6 | -50° to 450° | 3 5/16" | 6 1/4" | 9 5/16" | 00000000 | 000000 |
1 | Female | NPTF | Full | 46 | 720 psi @ 150° F | 150 psi @ 366° F | Zero Pressure Drop | 6 | -50° to 450° | 3 11/16" | 6 1/4" | 10 1/16" | 00000000 | 000000 |
1 1/2 | Female | NPTF | Full | 120 | 720 psi @ 150° F | 150 psi @ 366° F | Zero Pressure Drop | 6 | -50° to 450° | 4 9/16" | 6 1/4" | 10 15/16" | 00000000 | 000000 |
2 | Female | NPTF | Standard | 60 | 720 psi @ 150° F | 150 psi @ 366° F | Zero Pressure Drop | 6 | -20° to 400° | 4 1/16" | 6 1/4" | 10 9/16" | 00000000 | 000000 |
316 Stainless Steel Body with Screw Terminals | ||||||||||||||
Normally Open or Normally Closed—120V AC | ||||||||||||||
1/2 | Female | NPTF | Full | 12 | 720 psi @ 150° F | 150 psi @ 366° F | Zero Pressure Drop | 10 | -20° to 400° | 2 15/16" | 6 1/4" | 8 7/8" | 00000000 | 000000 |
3/4 | Female | NPTF | Full | 32 | 720 psi @ 150° F | 150 psi @ 366° F | Zero Pressure Drop | 10 | -20° to 400° | 3 5/16" | 6 1/4" | 9 5/16" | 00000000 | 000000 |
1 | Female | NPTF | Full | 46 | 720 psi @ 150° F | 150 psi @ 366° F | Zero Pressure Drop | 10 | -20° to 400° | 3 11/16" | 6 1/4" | 10 1/16" | 00000000 | 000000 |
2 | Female | NPTF | Standard | 60 | 720 psi @ 150° F | 150 psi @ 366° F | Zero Pressure Drop | 10 | -20° to 400° | 4 1/16" | 6 1/4" | 10 9/16" | 00000000 | 000000 |
Maintain and repair these valves without unthreading pipe connections. They have a three-piece bolted body that disassembles inline for easy access to internal components. All operate on electricity to automatically start and stop flow. Valves don't require a minimum pressure drop between the inlet and the outlet for operation. All can be wired as normally closed unless actuated or normally open unless actuated. They are full port, so they do not restrict flow.
Body is 316 stainless steel for excellent corrosion resistance. The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages. Valves meet NEMA 4 for resistance to washdowns, splashing water, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Environmental Rating | Each | |
316 Stainless Steel Body with Screw Terminals | |||||||||||||
Normally Open or Normally Closed—120V AC | |||||||||||||
1/2 | Female | NPT | 15 | 1500 psi @ 100° F | Zero Pressure Drop | 2.5 | -20° to 450° | 2 5/8" | 5 5/8" | 8 5/16" | NEMA 4 | 0000000 | 0000000 |
3/4 | Female | NPT | 35 | 1500 psi @ 100° F | Zero Pressure Drop | 2.5 | -20° to 450° | 3" | 5 5/8" | 8 5/8" | NEMA 4 | 0000000 | 000000 |
1 | Female | NPT | 60 | 1500 psi @ 100° F | Zero Pressure Drop | 2.5 | -20° to 450° | 3 3/8" | 5 5/8" | 9 1/16" | NEMA 4 | 0000000 | 000000 |
1 1/2 | Female | NPT | 138 | 1200 psi @ 150° F | Zero Pressure Drop | 10 | -20° to 450° | 4 11/16" | 7" | 15 1/16" | NEMA 4 | 0000000 | 00000000 |
2 | Female | NPT | 270 | 1000 psi @ 200° F | Zero Pressure Drop | 15 | -20° to 450° | 5 3/16" | 7" | 15 5/8" | NEMA 4 | 0000000 | 00000000 |
With a slimmer motor than other motor-driven valves, these fit in tight spots. They operate on electricity to automatically start and stop flow. Valves don’t require a minimum pressure drop between the inlet and outlet for operation. All can be wired as normally closed unless actuated or normally open unless actuated. They are full port, so they do not restrict flow.
Body is 316 stainless steel for excellent corrosion resistance. The actuator is directly mounted to the valve body to minimize movement and reduce wear. The manual override allows you to operate the valve during power outages. All valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Each | |
316 Stainless Steel Body with Screw Terminals | |||||||||||||
Normally Open or Normally Closed—120V AC | |||||||||||||
1 | Female | NPT | 110 | 1000 psi @ 100° F | 150 psi @ 366° F | Zero Pressure Drop | 12 | 0° to 450° | 3 7/16" | 4 1/2" | 9 3/16" | 0000000 | 0000000 |
1 1/2 | Female | NPT | 350 | 1000 psi @ 100° F | 150 psi @ 366° F | Zero Pressure Drop | 12 | 0° to 450° | 4 1/2" | 4 1/2" | 10 5/16" | 0000000 | 000000 |
2 | Female | NPT | 600 | 1000 psi @ 100° F | 150 psi @ 366° F | Zero Pressure Drop | 27 | 0° to 450° | 5 7/16" | 5 3/8" | 12 13/16" | 0000000 | 00000000 |
Separate the union fittings on each end of these valves for fast installation and removal from pipelines. Valves come with both threaded NPT fittings and unthreaded socket-connect female fittings. They operate on electricity to automatically start and stop flow. Valves don’t require a minimum pressure drop between the inlet and outlet for operation. All can be wired as normally closed unless actuated or normally open unless actuated. They are full port, so they do not restrict flow.
The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. All valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Valve Dia. | Lg. | Ht. | Environmental Rating | Each | |
Dark Gray PVC Plastic Body with Screw Terminals | ||||||||||||||
Normally Open or Normally Closed—120V AC | ||||||||||||||
1/2 | Female | NPT | 8 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 4 5/8" | __ | 4 5/8" | 9 1/2" | NEMA 4X | 0000000 | 0000000 |
3/4 | Female | NPT | 16 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 4 3/4" | __ | 4 3/4" | 9 15/16" | NEMA 4X | 0000000 | 000000 |
1 | Female | NPT | 29 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 5 1/4" | __ | 5 1/4" | 10 5/8" | NEMA 4X | 0000000 | 000000 |
1 1/2 | Female | NPT | 90 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 6 3/4" | __ | 6 3/4" | 11 1/2" | NEMA 4X | 0000000 | 000000 |
2 | Female | NPT | 150 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 8" | __ | 8" | 12 1/2" | NEMA 4X | 0000000 | 000000 |
Light Gray CPVC Plastic Body with Screw Terminals | ||||||||||||||
Normally Open or Normally Closed—120V AC | ||||||||||||||
1 | Female | NPT | 29 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 190° | __ | 3" | 5 1/4" | 10 5/8" | NEMA 4X | 0000000 | 000000 |
1 1/2 | Female | NPT | 90 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 190° | __ | 4" | 6 3/4" | 11 1/2" | NEMA 4X | 0000000 | 000000 |
2 | Female | NPT | 150 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 190° | __ | 4 3/4" | 8" | 12 1/2" | NEMA 4X | 0000000 | 000000 |
Slide copper pipe into the solder-connect fittings on these valves and weld for a strong, permanent connection. They’re often used for remote on/off control in heating and cooling systems. All operate on electricity to automatically start and stop flow. Valves do not require a minimum pressure drop between the inlet and the outlet for operation. They are normally closed unless actuated. All are standard port, so they slightly restrict flow.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. The manual override allows you to operate the valve during power outages.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | For Copper Tube Size | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Each | |
Brass Body with Wire Leads | ||||||||||||
24V AC | ||||||||||||
5/8" | 1/2 | 4 | 300 psi @ 250° F | 15 psi @ 250° F | Zero Pressure Drop | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 0000000 |
7/8" | 3/4 | 4 | 300 psi @ 250° F | 15 psi @ 250° F | Zero Pressure Drop | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
1 1/8" | 1 | 4 | 300 psi @ 250° F | 15 psi @ 250° F | Zero Pressure Drop | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
120V AC | ||||||||||||
5/8" | 1/2 | 3 | 300 psi @ 250° F | 15 psi @ 250° F | Zero Pressure Drop | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
7/8" | 3/4 | 3 | 300 psi @ 250° F | 15 psi @ 250° F | Zero Pressure Drop | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
1 1/8" | 1 | 3 | 300 psi @ 250° F | 15 psi @ 250° F | Zero Pressure Drop | 9 | 35° to 250° | 3 1/2" | 3 11/16" | 4 1/4" | 00000000 | 000000 |
Their ball-valve design allows these valves to handle at least three times the flow of standard flanged valves. All operate on electricity to automatically start and stop flow. They don’t require a minimum pressure drop between the inlet and outlet for operation. Valves are normally open unless actuated. All are full port, so they do not restrict flow.
The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. A manual override allows you to operate the valve during power outages.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Bolts | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Flange OD | No. of Holes | Hole Size. | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Pressure Drop | Temp. Range, ° F | Valve Lg. | O'all Ht. | Each | |
Carbon Steel Body with Screw Terminals | |||||||||||||||
Normally Open—24V AC/24V DC | |||||||||||||||
2 | Female | 6" | 4 | 5/8" | No | 4 3/4" | 307 | 275 psi @ 100° F | 100 psi @ 338° F | Zero Pressure Drop | 0° to 365° | 3 1/4" | 19 1/16" | 0000000 | 0000000 |
3 | Female | 7 1/4" | 4 | 5/8" | No | 6" | 1,013 | 275 psi @ 100° F | 100 psi @ 338° F | Zero Pressure Drop | 0° to 365° | 4 13/16" | 22 5/8" | 0000000 | 00000000 |
Normally Open—120V AC | |||||||||||||||
2 | Female | 6" | 4 | 5/8" | No | 4 3/4" | 307 | 275 psi @ 100° F | 100 psi @ 338° F | Zero Pressure Drop | 0° to 365° | 3 1/4" | 19 1/16" | 0000000 | 000000 |
3 | Female | 7 1/4" | 4 | 5/8" | No | 6" | 1,013 | 275 psi @ 100° F | 100 psi @ 338° F | Zero Pressure Drop | 0° to 365° | 4 13/16" | 22 5/8" | 0000000 | 00000000 |
For high-flow chemical-processing applications, these valves have a ball-valve design that provides at least three times the flow of standard flanged valves. They have a 316 stainless steel body and a PTFE seal that can stand up to aggressive and corrosive solutions. Valves operate on electricity to automatically start and stop flow. They don’t require a minimum pressure drop between the inlet and outlet for operation. All are normally open unless actuated. Valves are full port, so they do not restrict flow.
The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. The manual override allows you to operate the valve during power outages.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Bolts | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
316 Stainless Steel Body with Screw Terminals | |||||||||||||||
Normally Open—24V AC/24V DC | |||||||||||||||
2 | Female | 6" | 4 | 5/8" | No | 4 3/4" | 307 | 275 psi @ 100° F | 100 psi @ 338° F | Zero Pressure Drop | 0° to 365° | 3 1/4" | 19 1/16" | 0000000 | 000000000 |
3 | Female | 7 1/4" | 4 | 5/8" | No | 6" | 1,013 | 275 psi @ 100° F | 100 psi @ 338° F | Zero Pressure Drop | 0° to 365° | 4 13/16" | 22 5/8" | 0000000 | 00000000 |
Normally Open—120V AC | |||||||||||||||
2 | Female | 6" | 4 | 5/8" | No | 4 3/4" | 307 | 275 psi @ 100° F | 100 psi @ 338° F | Zero Pressure Drop | 0° to 365° | 3 1/4" | 19 1/16" | 0000000 | 00000000 |
3 | Female | 7 1/4" | 4 | 5/8" | No | 6" | 1,013 | 275 psi @ 100° F | 100 psi @ 338° F | Zero Pressure Drop | 0° to 365° | 4 13/16" | 22 5/8" | 0000000 | 00000000 |
Separate the union fittings on each end of these valves for fast installation and removal from pipelines. Valves come with both threaded NPT fittings and unthreaded socket-connect female fittings. They operate on electricity to automatically start and stop flow. These valves don’t require a minimum pressure drop between the inlet and outlet for operation. All can be wired as normall closed unless actuated or normally open unless actuated. They are full port, so they do not restrict flow.
The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. All valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Environmental Rating | Each | |
Normally Open or Normally Closed—120V AC | |||||||||||||
1/2 | Female | NPT | 8 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 4 5/8" | 4 5/8" | 9 1/2" | NEMA 4X | 0000000 | 0000000 |
3/4 | Female | NPT | 16 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 4 3/4" | 4 3/4" | 9 15/16" | NEMA 4X | 0000000 | 000000 |
1 | Female | NPT | 29 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 5 1/4" | 5 1/4" | 10 5/8" | NEMA 4X | 0000000 | 000000 |
1 1/2 | Female | NPT | 90 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 6 3/4" | 6 3/4" | 11 1/2" | NEMA 4X | 0000000 | 000000 |
2 | Female | NPT | 150 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 140° | 8" | 8" | 12 1/2" | NEMA 4X | 0000000 | 000000 |
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Environmental Rating | Each | |
Normally Open or Normally Closed—120V AC | |||||||||||||
1 | Female | NPT | 29 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 190° | 5 1/4" | 5 1/4" | 10 5/8" | NEMA 4X | 0000000 | 0000000 |
1 1/2 | Female | NPT | 90 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 190° | 6 3/4" | 6 3/4" | 11 1/2" | NEMA 4X | 0000000 | 000000 |
2 | Female | NPT | 150 | 250 psi @ 70° F | Zero Pressure Drop | 2.5 | 40° to 190° | 8" | 8" | 12 1/2" | NEMA 4X | 0000000 | 000000 |
For food and beverage systems that require frequent cleaning, these valves have polished internal surfaces and sanitary quick-clamp connections for easy disassembly. The three-piece bolted body comes apart for access to internal components without unthreading pipe connections and removing the valve from your line. Valves operate on electricity to automatically start and stop flow. They don't require a minimum pressure drop between the inlet and the outlet for operation. All are normally open unless actuated. Valves are full port, so they do not restrict flow.
Body is 316 stainless steel for excellent corrosion resistance. The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. The manual override allows you to operate the valve during power outages.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | Gender | Connection Style | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Each | |
316 Stainless Steel Body with Screw Terminals | ||||||||||||
Normally Open—24V AC/24V DC | ||||||||||||
1/2" | Female | Quick Clamp | 15 | 1000 psi @ 100° F | Zero Pressure Drop | 9 | -20° to 365° | 3 1/2" | 7 7/16" | 8 3/16" | 0000000 | 0000000 |
3/4" | Female | Quick Clamp | 34 | 1000 psi @ 100° F | Zero Pressure Drop | 9 | -20° to 365° | 4" | 7 5/8" | 8 5/8" | 0000000 | 000000 |
1" | Female | Quick Clamp | 56 | 1000 psi @ 100° F | Zero Pressure Drop | 8 | -20° to 365° | 4 1/2" | 8 3/16" | 9" | 0000000 | 000000 |
1 1/2" | Female | Quick Clamp | 125 | 1000 psi @ 100° F | Zero Pressure Drop | 8 | -20° to 365° | 5 1/2" | 9 1/8" | 11 5/16" | 0000000 | 000000 |
2" | Female | Quick Clamp | 250 | 1000 psi @ 100° F | Zero Pressure Drop | 9 | -20° to 365° | 6 1/4" | 10 3/8" | 12 11/16" | 0000000 | 000000 |
Normally Open—120V AC | ||||||||||||
1/2" | Female | Quick Clamp | 15 | 1000 psi @ 100° F | Zero Pressure Drop | 9 | -20° to 365° | 3 1/2" | 7 7/16" | 8 3/16" | 0000000 | 000000 |
3/4" | Female | Quick Clamp | 34 | 1000 psi @ 100° F | Zero Pressure Drop | 9 | -20° to 365° | 4" | 7 5/8" | 8 5/8" | 0000000 | 000000 |
1" | Female | Quick Clamp | 56 | 1000 psi @ 100° F | Zero Pressure Drop | 8 | -20° to 365° | 4 1/2" | 8 3/16" | 9" | 0000000 | 000000 |
1 1/2" | Female | Quick Clamp | 125 | 1000 psi @ 100° F | Zero Pressure Drop | 8 | -20° to 365° | 5 1/2" | 9 1/8" | 11 5/16" | 0000000 | 000000 |
2" | Female | Quick Clamp | 250 | 1000 psi @ 100° F | Zero Pressure Drop | 9 | -20° to 365° | 6 1/4" | 10 3/8" | 12 11/16" | 0000000 | 000000 |
These valves meet NSF/ANSI 61 for drinking water applications. All operate on electricity to automatically start and stop flow. They don't require a minimum pressure drop between the inlet and outlet for operation. Valves are normally closed unless actuated. All are full port, so they do not restrict flow.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Environmental Rating | Specifications Met | Each | |
Dark Gray PVC Plastic Body with Wire Leads | ||||||||||||||
Normally Closed—120V AC | ||||||||||||||
1/2 | Female | NPT | 42 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 3 1/16" | 5 3/8" | 7 3/8" | NEMA 4X | NSF/ANSI 61 | 0000000 | 0000000 |
3/4 | Female | NPT | 87 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 3 9/16" | 5 3/8" | 7 13/16" | NEMA 4X | NSF/ANSI 61 | 0000000 | 000000 |
1 | Female | NPT | 157 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 4" | 5 3/8" | 8 1/8" | NEMA 4X | NSF/ANSI 61 | 0000000 | 000000 |
1 1/4 | Female | NPT | 311 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 4 5/8" | 6 1/16" | 8 15/16" | NEMA 4X | NSF/ANSI 61 | 0000000 | 000000 |
1 1/2 | Female | NPT | 429 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 5 1/4" | 6 1/16" | 9 3/8" | NEMA 4X | NSF/ANSI 61 | 0000000 | 000000 |
2 | Female | NPT | 768 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 6" | 6 1/16" | 10 3/16" | NEMA 4X | NSF/ANSI 61 | 0000000 | 000000 |
Insert unthreaded pipe into the socket ends and bond with PVC primer and cement to create a permanent, leak-tight connection. These valves meet NSF/ANSI Standard 61 for drinking water applications. All operate on electricity to automatically start and stop flow. Valves don’t require a minimum pressure drop between the inlet and outlet for operation. They are normally closed unless actuated. All valves are full port, so they do not restrict flow.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Actuation Time, sec. | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Environmental Rating | Each | |
Dark Gray PVC Plastic Body with Wire Leads | ||||||||||||
Normally Closed—120V AC | ||||||||||||
1/2 | Female | 42 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 3 1/16" | 5 3/8" | 7 3/8" | NEMA 4X | 0000000 | 0000000 |
3/4 | Female | 87 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 3 9/16" | 5 3/8" | 7 13/16" | NEMA 4X | 0000000 | 000000 |
1 | Female | 157 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 4" | 5 3/8" | 8 1/8" | NEMA 4X | 0000000 | 000000 |
1 1/4 | Female | 311 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 4 5/8" | 6 1/16" | 8 15/16" | NEMA 4X | 0000000 | 000000 |
1 1/2 | Female | 429 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 5 1/4" | 6 1/16" | 9 3/8" | NEMA 4X | 0000000 | 000000 |
2 | Female | 768 | 235 psi @ 100° F | Zero Pressure Drop | 5 | 40° to 140° | 6" | 6 1/16" | 10 3/16" | NEMA 4X | 0000000 | 000000 |
To maintain sanitary standards in food and beverage applications, these valves have sanitary quick-clamp connections and polished internal surfaces for easy cleaning. The three-piece bolted body comes apart for access to internal components without unthreading pipe connections and removing the valve from your line. They have a ball-valve design that provides higher flow rates than other air-driven valves. All operate on compressed air to automatically start and stop flow faster than motor-driven valves. You must control the air to the actuator using either an electric pilot valve or a manual on/off valve (not included). These valves do not require a minimum pressure drop between the inlet and the outlet for operation. All are full port, so they do not restrict flow.
Body is 316 stainless steel for excellent corrosion resistance. The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages.
Single-acting actuators only require air pressure to open the valve; they automatically spring closed when the air turns off. These valves are normally closed unless actuated. Double-acting actuators require air pressure to open and close the valve. Once actuated, these valves remain actuated until air pressure is applied, so they do not have a valve starting position.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Overall | Air | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | Gender | Connection Style | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | Lg. | Ht. | Connection | Pressure Range, psi | Each | |
316 Stainless Steel Body with Screw Terminals | |||||||||||||
Single Acting: Air-to-Open, Spring Return (Normally Closed)—120V AC | |||||||||||||
1/2" | Female | Quick Clamp | 15 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 3 1/2" | 6 3/8" | 5 13/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 0000000 |
3/4" | Female | Quick Clamp | 34 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 4" | 6 3/8" | 5 13/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
1" | Female | Quick Clamp | 56 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 4 1/2" | 8 1/8" | 7 1/4" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
1 1/2" | Female | Quick Clamp | 125 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 5 1/2" | 9 3/8" | 8 13/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
2" | Female | Quick Clamp | 250 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 6 1/4" | 10 11/16" | 9 7/8" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
Double Acting: Air-to-Open, Air-to-Close—120V AC | |||||||||||||
1/2" | Female | Quick Clamp | 15 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 3 1/2" | 5 1/2" | 5 3/8" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
3/4" | Female | Quick Clamp | 34 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 4" | 5 1/2" | 5 11/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
1" | Female | Quick Clamp | 56 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 4 1/2" | 5 1/2" | 6 3/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
1 1/2" | Female | Quick Clamp | 125 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 5 1/2" | 6 3/8" | 7 11/16" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
2" | Female | Quick Clamp | 250 | 1000 psi @ 100° F | Zero Pressure Drop | -20° to 365° | 6 1/4" | 8 1/8" | 8 5/8" | 1/4 NPT Female | 40 to 115 | 0000000 | 000000 |
Also known as proportional V-ball valves, these have a motor that adjusts and regulates flow in applications with higher flow rates and pressures than solenoid valves. As you increase the intensity of the electrical signal, the motor opens the valve, moving a ball with a V-cut opening that proportionately allows more flow as the valve opens. They're often integrated into PLC systems for automatic control over the valve position based on system conditions. Valves can accept both 4-20 mA current and 0-10 DC voltage. All are normally open unless actuated. They don't require a minimum pressure drop between the inlet and outlet for operation. All are full port, so they do not restrict flow.
The three-piece bolted body comes apart for access to internal components without unthreading pipe connections and removing the valve from your line. It is 316 stainless steel for excellent corrosion resistance. The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. A manual override allows you to operate the valve during power outages.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Input Signal | O'all | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Gender | Thread Type | Max. Pressure | Pressure Drop | Min. Pressure Drop Required | Temp. Range, °F | Actuation Time | Current | Voltage | Voltage Range | Valve Lg. | Ht. | Lg. | Environmental Rating | Each | |
316 Stainless Steel Body with Screw Terminals | ||||||||||||||||
Normally Open—100V AC to 240V AC | ||||||||||||||||
1 | Female | NPT | 1,000 psi @ 100° F | Zero Pressure Drop | None | 0° to 400° | 8 sec. | 4mA-20mA | 0V DC-10V DC | 100V AC to 240V AC | 3 5/8" | 10 3/4" | 7 3/8" | NEMA 4X | 0000000 | 000000000 |
1 1/2 | Female | NPT | 1,000 psi @ 100° F | Zero Pressure Drop | None | 0° to 400° | 9 sec. | 4mA-20mA | 0V DC-10V DC | 100V AC to 240V AC | 4 9/16" | 12 9/16" | 7 3/4" | NEMA 4X | 0000000 | 00000000 |
2 | Female | NPT | 1,000 psi @ 100° F | Zero Pressure Drop | None | 0° to 400° | 9 sec. | 4mA-20mA | 0V DC-10V DC | 100V AC to 240V AC | 5 3/8" | 12 15/16" | 7 3/4" | NEMA 4X | 0000000 | 00000000 |
3 | Female | NPT | 350 psi @ 100° F | Zero Pressure Drop | None | 0° to 400° | 27 sec. | 4mA-20mA | 0V DC-10V DC | 100V AC to 240V AC | 7 1/16" | 15 1/2" | 10 1/2" | NEMA 4X | 0000000 | 00000000 |
The motor on these valves can handle diverting applications with high flow rates and pressures. They operate on electricity to automatically divert flow between ports. Valves do not require a minimum pressure drop between the inlet and outlet for operation. Valves can direct flow from the center-port inlet to either side-port outlet. They cannot shut off flow. All are full port, so they do not restrict flow.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows which direction flow is being diverted. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. A manual override allows you to operate the valve during power outages.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
O'all | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flow Pattern | For Use With | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Min. Pressure Drop Required | Temp. Range, °F | Actuation Time | Valve Lg. | Ht. | Lg. | Each | |
Brass Body with Wire Leads—120V AC, 240V AC | |||||||||||||
NPT Female × NPT Female × NPT Female | |||||||||||||
1/4 | L-Pattern | Air, Argon, Helium, Krypton, Neon, Oil, Xenon | 3.24 | 400 psi @ 100° F | Zero Pressure Drop | None | 0° to 130° | 10 sec. | 2 5/8" | 7 7/16" | 6 7/16" | 0000000 | 0000000 |
3/8 | L-Pattern | Air, Argon, Helium, Krypton, Neon, Oil, Water, Xenon | 3.47 | 400 psi @ 100° F | Zero Pressure Drop | None | 0° to 130° | 10 sec. | 2 5/8" | 7 7/16" | 6 7/16" | 0000000 | 000000 |
1/2 | L-Pattern | Air, Argon, Helium, Krypton, Neon, Oil, Xenon | 4.16 | 400 psi @ 100° F | Zero Pressure Drop | None | 0° to 130° | 10 sec. | 2 7/8" | 7 7/16" | 6 7/16" | 0000000 | 000000 |
3/4 | L-Pattern | Air, Argon, Helium, Krypton, Neon, Oil, Water, Xenon | 7.05 | 400 psi @ 100° F | Zero Pressure Drop | None | 0° to 130° | 10 sec. | 3 3/16" | 7 5/8" | 6 7/16" | 0000000 | 000000 |
1 | L-Pattern | Air, Argon, Helium, Krypton, Neon, Oil, Xenon | 12.83 | 400 psi @ 100° F | Zero Pressure Drop | None | 0° to 130° | 8 sec. | 3 3/4" | 10" | 7 1/2" | 0000000 | 000000 |
1 1/2 | L-Pattern | Air, Argon, Helium, Krypton, Neon, Oil, Water, Xenon | 29.71 | 400 psi @ 100° F | Zero Pressure Drop | None | 0° to 130° | 8 sec. | 4 7/8" | 11 3/16" | 7 1/2" | 0000000 | 000000 |
2 | L-Pattern | Air, Argon, Helium, Krypton, Neon, Oil, Water, Xenon | 43.81 | 400 psi @ 100° F | Zero Pressure Drop | None | 0° to 130° | 9 sec. | 5 3/4" | 13 1/16" | 8 7/16" | 0000000 | 000000 |