Manufacturer Model Number Manufacturer Model Number |
---|
Measures Measures |
---|
|
AC Calculation AC Calculation |
---|
|
Safety Rating Safety Rating |
---|
|
Maximum Resistance Maximum Resistance |
---|
|
|
Certification Certification |
---|
|
Measurement Increments Measurement Increments |
---|
|
|
Software Features Software Features |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Calculation Features Calculation Features |
---|
|
Display Features Display Features |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Safety Ratings for Electrical Testing
More
Fluke Multimeters

Rely on the quality and durability of a Fluke multimeter when taking voltage, resistance, and other electrical measurements.
Average sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors. True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Multimeters with Calibration Certificate | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current | Max. DC Current | Hardware Features | Display Count | Includes | Each | |
Average Sensing AC Calculation | ||||||||||||
77IV | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.3% | 10 A | 10 A | Overload Protection | 6,000 | Test Leads | 0000000 | 0000000 |
True RMS AC Calculation | ||||||||||||
113 | CAT III, 600V | AC Voltage, Capacitance, DC Voltage, Resistance | 600 | 600 | 2% | __ | __ | Lead Storage | 6,000 | Test Leads | 00000000 | 000000 |
114 | CAT III, 600V | AC Voltage, DC Voltage, Low Impedance, Resistance | 600 | 600 | 0.5% | __ | __ | Overload Protection | 6,000 | Test Leads | 00000000 | 000000 |
115 | CAT III, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Low Impedance, Resistance | 600 | 600 | 0.5% | 10 A | 10 A | Overload Protection | 6,000 | Test Leads | 00000000 | 000000 |
116 | CAT III, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 600 | 600 | 0.5% | 600 µA | 600 µA | Overload Protection | 6,000 | Temperature Probe, Test Leads | 00000000 | 000000 |
117 | CAT III, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Low Impedance, Resistance | 600 | 600 | 0.5% | 10 A | 10 A | Overload Protection | 6,000 | Test Leads | 00000000 | 000000 |
117/323 | CAT III, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Low Impedance, Resistance | 600 | 600 | 0.5% | 400 A | 10 A | Overload Protection | 6,000 | Carrying Case, Fluke 323 True RMS Clamp Meter, Magnetic Hanger, Test Leads | 00000000 | 000000 |
Fluke High-Accuracy Multimeters

These Fluke multimeters provide results at least twice as accurate as standard Fluke multimeters. Fluke is known for quality and durability.
Average sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors. True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Multimeters with Calibration Certificate | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Hardware Features | Display Count | Includes | Each | |
Average Sensing AC Calculation | ||||||||||||
83V | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.1% | 10 | 10 | Lead Storage, Overload Protection | 6,000 | Alligator Clips, Test Leads | 00000000 | 0000000 |
88V | CAT IV, 600V | AC Voltage, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.1% | 10 | 10 | Overload Protection | 20,000 | High-Impact Holster, Test Leads | 00000000 | 000000 |
True RMS AC Calculation | ||||||||||||
175 | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.15% | 10 | 10 | Lead Storage, Overload Protection | 6,000 | Test Leads | 00000000 | 000000 |
177 | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.09% | 10 | 10 | Lead Storage, Overload Protection | 6,000 | Test Leads | 00000000 | 000000 |
179 | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 10 | 10 | Lead Storage, Overload Protection | 6,000 | Temperature Probe, Test Leads | 00000000 | 000000 |
87V | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Lead Storage, Overload Protection | 20,000 | Alligator Clips, Temperature Probe, Test Leads | 00000000 | 000000 |
87V/E2 | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Lead Storage, Overload Protection | 20,000 | Alligator Clips, Carrying Case, Magnetic Hanger, Temperature Probe, Test Leads | 00000000 | 000000 |
Fluke Data-Logging Multimeters
Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
To download and analyze data on a computer, software is required (not included).
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 50,000-count multimeters show numbers up to 49,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.

Multimeters with Calibration Certificate | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Model Number | Data Log Capacity | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Hardware Features | Display Count | Includes | Each | |
True RMS AC Calculation | |||||||||||||
287 | 10,000 | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 0000000 |
289 | 15,000 | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 00000000 |
Download and analyze data from a Fluke data-logging multimeter. Connect your multimeter to a computer with the included USB cord.
Manufacturer Model Number | For Fluke Model Number | For Operating System | Each | |
FVF-SC2 | 287, 289 | Windows 7 and earlier | 0000000 | 0000000 |
Fluke Water-Resistant Multimeters

For taking electrical measurements in washdown environments, choose the durability and quality of a Fluke multimeter with an IP67-rated housing.
Average sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors. True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Multimeters with Calibration Certificate | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Hardware Features | Display Count | Includes | Each | |
Average Sensing AC Calculation | ||||||||||||
27 II | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.1% | 10 | 10 | Overload Protection | 6,000 | Alligator Clips, Test Leads | 00000000 | 0000000 |
True RMS AC Calculation | ||||||||||||
28 II | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.05% | 10 | 10 | Overload Protection | 6,000 | Alligator Clips, Temperature Probe, Test Leads | 00000000 | 000000 |
Fluke Wireless Remote-Reading Multimeters

A wireless connection transmits electrical measurements from the multimeter to a separate display, so you can take measurements in hard-to-reach or potentially dangerous locations. Fluke multimeters are known for quality and durability.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Fluke 233 has a detachable display that communicates with the multimeter using built-in low-power wireless technology. The Fluke 233 with calibration certificate includes a document stating that it has passed a test for accuracy.
Multimeters with Calibration Certificate | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current | Max. DC Current | Hardware Features | Display Count | Includes | Each | |
True RMS AC Calculation | ||||||||||||
233 | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.25% | 10 A | 10 A | Overload Protection | 6,000 | Alligator Clips, Temperature Probe, Test Leads | 00000000 | 0000000 |
Tweezer-Style Electronic-Component Testers



Grasp tiny components on circuit boards and other electronic systems in order to test, identify, and troubleshoot them. These testers perform a complete analysis of components by measuring inductance, capacitance, resistance, dissipation factor, quality factor, impedance, and equivalent series resistance. They automatically determine the component model and test parameters, but you can manually select the parameters and test signal levels too. An LED screen displays the component type and measurements. These testers also check if diode voltage is open or shorted, if components are in the best-performance tolerance range so you can sort them, and if there’s continuity in the resistance readings or a shorted conductor. All include a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. They run on a rechargeable battery, so you aren’t tethered by a power cord.
These testers have tweezer-style pointed tips for precision control. Made of stainless steel, the tips withstand wear and high temperatures. They’re also gold plated to conduct electricity and resist corrosion and tarnishing, which hurt conductivity.
Testers with Bluetooth connectivity work with iOS and Android devices to download, store, and share data.
Tip | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures | Capacitance Range | Inductance Range | Resistance Range | Width | Height | Depth | Style | Length | Material | Batteries Included | Each | |
Capacitance, Dissipation Factor, Equivalent Series Resistance, Impedance, Inductance, Quality Factor, Resistance | 0.5 pF-4,999 µF | 1 µH-999 mH | 0.1 ohms-9.9 megohms | 0.8" | 6" | 0.6" | Standard | 1 1/4" | Gold-Plated Stainless Steel | Yes | 0000000 | 0000000 |
Tip | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures | Capacitance Range | Inductance Range | Resistance Range | Width | Height | Depth | Style | Length | Material | Batteries Included | Each | |
Capacitance, Dissipation Factor, Equivalent Series Resistance, Impedance, Inductance, Quality Factor, Resistance | 0.5 pF-4,999 µF | 1 µH-999 mH | 0.1 ohms-9.9 megohms | 0.8" | 6" | 0.6" | Standard | 1 1/4" | Gold-Plated Stainless Steel | Yes | 0000000 | 0000000 |

Tip Style | Tip Length | Tip Material | Pair | |
Standard | 1 1/4" | Gold-Plated Stainless Steel | 00000000 | 000000 |
Fluke Instrumentation Process Control Multimeters

With this combination loop calibrator and multimeter, check for current control loop issues in PLCs, motors, and fans in addition to taking other electrical measurements. When used as a loop calibrator, the current input as well as the percentage of the input scale is shown on the dual display, giving you quick diagnostic information. Fluke is known for quality and durability.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 4,000-count multimeters show numbers up to 3,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Multimeters with Calibration Certificate | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Hardware Features | Display Count | Includes | Each | |
True RMS AC Calculation | ||||||||||||
787B | CAT III, 1,000V | AC Voltage, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.1% | 0.44 | 0.44 | Lead Storage, Overload Protection | 4,000 | Alligator Clips, Test Leads | 0000000 | 000000000 |
789 | CAT IV, 600V | AC Voltage, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.1% | 0.44 | 0.44 | Overload Protection | 4,000 | Alligator Clips, Test Leads | 00000000 | 00000000 |
Fluke Insulation Testing Multimeters

Check insulation quality in electrical equipment such as motors and power tools. You can also take other electrical measurements with these Fluke multimeters, known for quality and durability.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 6,000-count multimeters show numbers up to 5,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Multimeters with Calibration Certificate | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Model Number | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, mA | Max. DC Current, mA | Hardware Features | Display Count | Includes | Environmental Rating | Each | |
True RMS AC Calculation | |||||||||||||
1577 | CAT IV, 600V | AC Voltage, Current, DC Voltage, Resistance | 1,000 | 1,000 | 0.2% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Test Leads | IP40 | 00000000 | 000000000 |
1587 FC | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.09% | 400 | 400 | Overload Protection | 6,000 | Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test Leads | IP40 | 00000000 | 00000000 |
Fluke Clamp-On Multimeters

Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Multimeters with Calibration Certificate | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Model Number | Jaw Opening | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Display Count | Includes | Each | |
True RMS AC Calculation | ||||||||||||
324 | 1.18" | CAT IV, 300V | AC Voltage, Capacitance, Current, DC Voltage, Resistance, Temperature | 600 | 600 | 1% | 400 | __ | 6,000 | Carrying Case, Temperature Probe, Test Leads | 00000000 | 0000000 |
373 | 1.3" | CAT IV, 300V | AC Voltage, Capacitance, Current, DC Voltage, Resistance | 600 | 600 | 1% | 600 | __ | 6,000 | Carrying Case, Test Leads | 00000000 | 000000 |
374 FC | 1.3" | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Resistance | 1,000 | 1,000 | 1% | 600 | 600 | 6,000 | Carrying Case, Test Leads | 00000000 | 000000 |
376 FC | 1.3" | CAT IV, 600V | AC Voltage, Capacitance, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Carrying Case, Flexible Current Loop, Test Leads | 00000000 | 000000 |
381 | 1.34" | CAT IV, 600V | AC Voltage, Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Alligator Clips, Carrying Case, Flexible Current Loop, Removable Wireless Display, Test Leads | 00000000 | 00000000 |
Fluke Open-Jaw Multimeters

Run a cable through the open jaw to test current without interrupting the circuit. These multimeters are especially useful for high current measurements and include test leads to perform other electrical tests. Fluke multimeters are known for quality and durability.
All are average sensing, so they take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
Display count is an industry designation and not an actual value. These 1,000-count multimeters show numbers up to 999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Multimeters with Calibration Certificate | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer Model Number | Jaw Opening | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Display Count | Includes | Each | |
Average Sensing AC Calculation | |||||||||||
T5-600 | 0.5" | CAT III, 600V | AC Voltage, Current, DC Voltage, Resistance | 600 | 600 | 1% | 100 | 1,000 | Test Leads | 0000000 | 0000000 |
T5-1000 | 0.5" | CAT IV, 600V | AC Voltage, Current, DC Voltage, Resistance | 1,000 | 1,000 | 1% | 100 | 1,000 | Test Leads | 0000000 | 000000 |