Specifications Met Specifications Met | Hide |
---|
Application Application |
---|
|
Garment Garment |
---|
|
|
Arc Rating Arc Rating |
---|
Flame-Resistant Application Flame-Resistant Application |
---|
|
Cuff Style Cuff Style |
---|
|
|
Material Material |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Chest Size Chest Size |
---|

Shirt Style Shirt Style |
---|
|
Coverall Style Coverall Style |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Maximum Use Voltage Maximum Use Voltage |
---|
|
|
Construction Construction |
---|
![]() | Woven |
About Glove Sizing
More
About Flame-Resistant Arc-Rated Personal Protection
More
About Cut-Resistant Gloves
More
Flame- and Arc-Flash-Protection Rain Suits

These suits meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They also meet ASTM F2733 standards for protection against flash fires. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These suits are made of PVC-coated Nomex aramid. Jackets have snaps down the front and a storm flap to keep rain out. Sleeves have hook and loop cuffs; tighten to fit your wrist or expand to wear over gloves. The bib overalls have adjustable suspenders to modify the length.
When measuring chest size, measure around the fullest part of your chest. Find your waist size by measuring just above the top of your hip bone. Take all measurements over any clothing you expect to wear under these suits.
Available Sizes | |||
---|---|---|---|
Size | Chest Size | Waist Size | Inseam Lg. |
S | 46" | 42" | 28" |
M | 50" | 46" | 29" |
L | 54" | 50" | 30" |
XL | 58" | 54" | 31" |
2XL | 62" | 58" | 32" |
3XL | 66" | 62" | 32" |
Flame- and Arc-Flash-Protection Rain Jackets


These jackets meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They also meet ASTM F2733 standards for protection against flash fires. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These jackets are made of PVC-coated Nomex aramid. They have snaps down the front and a storm flap to keep rain out. They have hook and loop cuffs; tighten to fit your wrist or gloves.
Fasten a hood (sold separately) to the collar snaps.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under these jackets.
Available Sizes | ||
---|---|---|
Size | Chest Size | Lg. |
S | 46" | 29" |
M | 50" | 30" |
L | 54" | 31" |
XL | 58" | 31" |
2XL | 62" | 32" |
3XL | 66" | 32" |
Flame- and Arc-Flash-Protection High-Visibility Vests


These vests meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 1 and ANSI/ISEA 107 standards for high visibility. They are rated ANSI Class 2 for working on or near roadways. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These vests are mesh acrylic and are self-extinguishing. They are stitched with Nomex thread for added durability. They have hook and loop closures down the front and one waist pocket.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under these vests.
Available Sizes | |
---|---|
Size | Chest Size |
M | 36"/38" |
L | 40"/42" |
XL | 44"/46" |
2XL | 48"/50" |
3XL | 52"/54" |
4XL | 56"/58" |
5XL | 60"/62" |
Flame and Arc-Flash Cold-Protection Face Masks

These face masks meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These hats are made of abrasion-resistant aramid/viscose blend fabric, which keeps you warm without accumulating moisture.
Material | Arc Rating, cal/cm2 | Arc Rated PPE Category | Specifications Met | Color | Size | Each | |
Aramid/Viscose Fabric Blend | 12.2 | 2 | NFPA 70E | Blue | One Size | 00000000 | 000000 |
Flame and Arc-Flash Cold-Protection Hats

These hats meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These hats are made of abrasion-resistant aramid/viscose blend fabric, which keeps you warm without accumulating moisture.
Material | Arc Rating, cal/cm2 | Arc Rated PPE Category | Specifications Met | Color | Size | Each | |
Aramid/Viscose Fabric Blend | 20 | 2 | NFPA 70E | Black | One Size | 00000000 | 000000 |
Flame- and Arc-Flash-Protection Coats

These coats meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These coats are made of breathable cotton and are self-extinguishing. They have a flap in the front that conceals the snaps.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under these coats.
Available Sizes | ||
---|---|---|
Size | Chest Size | Length |
L | 43 1/2" | 42" |
L | 45 1/2" | 42" |
XL | 47 1/2" | 42" |
XL | 49 1/2" | 42" |
2XL | 51 1/2" | 42" |
2XL | 53 1/2" | 42 1/2" |
3XL | 55 1/2" | 42 1/2" |
3XL | 57 1/2" | 43" |
4XL | 59 1/2" | 43" |
Flame- and Arc-Flash-Protection Jackets

These jackets meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 4. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These jackets are made of a durable modacrylic/aramid blend. They have a flap in the front that conceals the zipper.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under these jackets.
Flame- and Arc-Flash-Protection Coveralls



These coveralls meet NFPA 70E standards for protection against electrical arc flashes. Check the personal protection equipment (PPE) category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance.
NFPA 2112 rated coveralls protect against flash fires.
Nomex aramid (men's) won’t melt or drip if it catches fire. It resists wear and abrasion better than other materials. It’s arc rated for PPE category 1.
Cotton (men's) is lightweight and provides better breathability than other materials. Coveralls are stitched with Nomex threads for added durability. They are self-extinguishing and arc rated for PPE category 2.
Cotton/nylon blend (men's) is soft, yet wear resistant, and provides better breathability than modacrylic/aramid blend and Nomex aramid. It’s arc rated for PPE category 2.
Acrylic/Buna-N (men's) is breathable and moisture wicking to keep you cool and dry. It’s arc rated for PPE category 2.
Carbon fiber (women’s), similar to acrylic/Buna-N, is lightweight, breathable, and moisture wicking to keep you cool and dry. It’s arc rated for PPE category 2.
Modacrylic/aramid blend (men's) provides better resistance against arc flashes and is more durable than cotton and acrylic/Buna-N. It’s arc rated for PPE category 4.
When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls. Long coveralls have added length in the torso, sleeves, and legs, so they are recommended for workers 6' 1" and taller.
Available Men's Sizes | |
---|---|
Size | Chest Size |
S | 36" |
S | 38" |
M | 42" |
M | 40" |
L | 46" |
L | 44" |
XL | 48" |
XL | 50" |
2XL | 52" |
2XL | 54" |
Available Men's Sizes | |
---|---|
Size | Chest Size |
S | 38" |
M | 42" |
M | 40" |
L | 46" |
L | 44" |
XL | 48" |
XL | 50" |
2XL | 54" |
2XL | 52" |
3XL | 56" |
Available Men's Sizes | |
---|---|
Size | Chest Size |
S | 36" |
M | 38" |
L | 42" |
XL | 44" |
2XL | 48" |
3XL | 52" |
Available Men's Sizes | |
---|---|
Size | Chest Size |
M | 40"/42" |
L | 44"/46" |
XL | 48"/50" |
2XL | 52"/54" |
3XL | 56"/58" |
4XL | 60"/62" |
Available Women's Sizes | |
---|---|
Size | Chest Size |
S | 34" |
M | 37" |
L | 40" |
XL | 43" |
2XL | 47" |
3XL | 50" |
Available Men's Sizes | |
---|---|
Size | Chest Size |
S | 36" |
M | 38" |
L | 42" |
XL | 44" |
2XL | 48" |
3XL | 52" |
Flame- and Arc-Flash-Protection Shirts


These shirts meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They also meet NFPA 2112 standards for protection against flash fire. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. Made of acrylic/Buna-N blend, these shirts are breathable and moisture wicking to keep you cool. They have buttons down the front and on the cuffs, as well as two chest pockets.
When measuring chest size, measure around the fullest part of your chest.
Available Women's Sizes | |
---|---|
Size | Chest Size |
S | 33"/35" |
M | 36"/38" |
L | 39"/41" |
XL | 42"/44" |
2XL | 46"/48" |
3XL | 49"/51" |
Flame- and Arc-Flash-Protection Bib Overalls

These overalls meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 4. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. Made of modacrylic/aramid blend, these overalls are extremely durable. They have adjustable suspenders; tighten or loosen them to modify the fit. Adjust the hook and loop straps on the cuffs to tighten pant legs around boots.
Find your waist size by measuring just above the top of your hip bone. Take all measurements over any clothing you expect to wear under these overalls.
Flame- and Arc-Flash-Protection Base Layers




Wear these fitted garments under clothing for an added layer of protection against intermittent exposure to flames and radiant heat. They meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 1 or 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. All base layer materials are lightweight, breathable, and moisture wicking for added comfort.
They all comply with OSHA 29 CFR 1910.269 standards for flame and arc flash protection.
Cotton/acrylic base layers are stretchy for increased mobility and range of motion.
When measuring chest size, measure around the fullest part of your chest.
Available Men's Sizes | |
---|---|
Size | Chest Size |
S | 34"/36" |
M | 38"/40" |
L | 42"/44" |
XL | 46"/48" |
2XL | 50"/52" |
3XL | 54"/56" |
Material | Arc Rating, cal/cm2 | Arc Rated PPE Category | Cuff Style | Specifications Met | Color | Choose a Size | Each | |
Short Sleeve | ||||||||
---|---|---|---|---|---|---|---|---|
Cotton/Acrylic Fabric Blend | 4 | 1 | Open | OSHA Compliant 29 CFR 1910.269, NFPA 70E, ASTM F1506 | Dark Blue | 0000000 | 0000000 | |
Long Sleeve | ||||||||
Cotton/Acrylic Fabric Blend | 4 | 1 | Knit | OSHA Compliant 29 CFR 1910.269, NFPA 70E, ASTM F1506 | Dark Blue | 0000000 | 000000 |
Available Women's Sizes | |
---|---|
Size | Chest Size |
XS | 30"/32" |
S | 34"/36" |
M | 38"/40" |
L | 42"/44" |
XL | 46"/48" |
2XL | 50"/52" |
3XL | 54"/56" |
Available Men's Sizes | ||
---|---|---|
Size | Waist Size | Inseam Lg. |
S | 27"-29" | 31" |
M | 30"-33" | 32" |
L | 32"-35" | 33" |
XL | 36"-39" | 34" |
2XL | 40"-43" | 34" |
3XL | 42"-45" | 35" |
Flame- and Arc-Flash-Protection Work Pants


These pants meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. They also meet NFPA 2112 standards for protection against flash fire. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These pants are made of a breathable cotton/nylon blend that’s lightweight, yet durable. Cuffs are open to fit over work boots. They have two waist pockets and two rear pockets.
Find your waist size by measuring just above the top of your hip bone.
Available Sizes | |
---|---|
Size | Waist Size |
XS | 28" |
S | 30" |
S | 32" |
M | 34" |
M | 36" |
L | 38" |
L | 40" |
XL | 42" |
XL | 44" |
Material | Arc Rating, cal/cm2 | Arc Rated PPE Category | Closure Type | Cuff Style | Features | Color | Inseam Lg. | Choose a Waist Size | Each | |
Cotton/Nylon Fabric Blend | 12 | 2 | Button | Open | Two Rear Pockets, Two Waist Pockets | Dark Blue | 30" | 000000 | 0000000 | |
Cotton/Nylon Fabric Blend | 12 | 2 | Button | Open | Two Rear Pockets, Two Waist Pockets | Dark Blue | 32" | 0000000 | 000000 | |
Cotton/Nylon Fabric Blend | 12 | 2 | Button | Open | Two Rear Pockets, Two Waist Pockets | Dark Blue | 34" | 000000 | 000000 |
Available Sizes | |
---|---|
Size | Waist Size |
0 | 30" |
2 | 31" |
4 | 32" |
6 | 33" |
8 | 34" |
10 | 36" |
12 | 38" |
14 | 40" |
16 | 42" |
Material | Arc Rating, cal/cm2 | Arc Rated PPE Category | Closure Type | Cuff Style | Features | Color | Inseam Lg. | Choose a Waist Size | Each | |
Cotton/Nylon Fabric Blend | 12 | 2 | Button | Open | Two Rear Pockets, Two Waist Pockets | Dark Blue | 30" | 00000000 | 0000000 | |
Cotton/Nylon Fabric Blend | 12 | 2 | Button | Open | Two Rear Pockets, Two Waist Pockets | Dark Blue | 31" | 00000000 | 000000 | |
Cotton/Nylon Fabric Blend | 12 | 2 | Button | Open | Two Rear Pockets, Two Waist Pockets | Dark Blue | 32" | 00000000 | 000000 |
Flame- and Arc-Flash-Protection Face Masks


Protect your head from electrical arc flashes. These face masks won’t melt or drip when exposed to intermittent flames. They meet NFPA 70E standards for personal protection equipment (PPE) category 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. Masks are soft, breathable, and washable.
Westex® UltraSoft® Rib fabric is a lightweight material that’s 88% flame-resistant cotton and 12% nylon knit.
CarbonX fabric is double-layered for better flame resistance than Westex® UltraSoft® Rib fabric.
Flame- and Arc-Flash-Protection Sweatshirts


These sweatshirts meet NFPA 70E for protection against electrical arc flashes and NFPA 2112 for flame resistance. The front zipper is fully covered for complete protection from fire. Sweatshirts are made of a blended fleece for comfort and warmth. Knit cuffs and a knit waistband fit snugly to prevent heat from escaping.
Flame-, Arc-Flash, and Cut-Protection Gloves

These gloves meet NFPA 70E for protection against arc-flash hazards. They are made with materials that protect against radiant heat and flames. All meet the ANSI/ISEA 105 standard, which designates levels of cut resistance based on the force needed to cut through the material of the glove using a razor blade.
Available Sizes | |
---|---|
Size | Glove Size |
XS | 6 |
S | 7 |
M | 8 |
L | 9 |
XL | 10 |
2XL | 11 |
Coating | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cut Resistance | Material | Coverage | Lg. | Cuff Style | Color | For Heat Exposure Type | Arc Rated PPE Category | Arc Rating | Features | Specifications Met | Choose a Size | Pair | |
Fiberglass/Modacrylic/Kevlar Aramid Fabric Blend | |||||||||||||
ANSI Level A4 | Neoprene Rubber | Palm | 9" | Knit | Black/Gray | Ambient | 2 | 9.4cal/cm2 | Kevlar Threads | ANSI/ISEA 105, NFPA 70E | 000000 | 000000 |
Electrical-Protection Gloves


ASTM D120 rated for use when handling live electrical equipment, these gloves come tested and marked with the test date. You have one year from the test date to put gloves into service before they must be retested. Once in use, gloves should be tested every six months. All gloves meet NFPA 70E for protection against arc-flash hazards.
ASTM defines voltage classes for rubber insulating gloves. Before working with electrical equipment, make sure you have the right protection.
Wear-indicating gloves have a colored inner layer that shows through the coating as it wears off, making it easy to inspect them for signs of wear such as cracks and pinholes.
Protectors (sold separately) must be worn over gloves for ASTM compliance when working with live electrical equipment. Protectors should be the same size as the gloves they will be worn over. Goatskin protectors cannot be sold to Canada due to import regulations.
Strap your glove to an inspection pump (sold separately) and inflate to check Class 1-4 gloves for cracks, pinholes, and other signs of wear. Purchase an adapter (sold separately) to use the inspection pump with Class 0 and 00 gloves.
Available Sizes | |
---|---|
Size | Glove Size |
M | 8 |
L | 9 |
XL | 10 |
2XL | 11 |
3XL | 12 |
ASTM Voltage Rating | Max. Use Voltage | Lg. | Texture | Cuff Style | Color | Arc Rated PPE Category | Arc Rating, cal/cm2 | Features | Choose a Size | Pair | |
Dielectric Rubber | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Class 00 | 500V AC | 11" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction | 0000000 | 000000 | |
Class 00 | 500V AC | 14" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction | 0000000 | 00000 | |
Class 0 | 1,000V AC | 11" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction | 0000000 | 00000 | |
Class 0 | 1,000V AC | 14" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction | 0000000 | 00000 | |
Class 1 | 7,500V AC | 14" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction | 0000000 | 000000 | |
Class 1 | 7,500V AC | 14" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction, Wear Indicator | 0000000 | 000000 | |
Class 2 | 17,000V AC | 14" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction | 0000000 | 000000 | |
Class 2 | 17,000V AC | 14" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction, Wear Indicator | 0000000 | 000000 | |
Class 2 | 17,000V AC | 16" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction | 0000000 | 000000 | |
Class 2 | 17,000V AC | 16" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction, Wear Indicator | 0000000 | 000000 | |
Class 3 | 26,500V AC | 16" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction | 0000000 | 000000 | |
Class 3 | 26,500V AC | 16" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction, Wear Indicator | 0000000 | 000000 | |
Class 4 | 36,000V AC | 18" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction | 0000000 | 000000 | |
Class 4 | 36,000V AC | 18" | Smooth | Open | Black | Not Rated | Not Rated | Rolled Cuffs, Seamless Construction, Wear Indicator | 0000000 | 000000 | |
Natural Rubber | |||||||||||
Class 00 | 500V AC | 11" | Smooth | Open | Red | 1 | 6.7 | Rolled Cuffs, Seamless Construction | 0000000 | 00000 | |
Class 0 | 1,000V AC | 11" | Smooth | Open | Red | 1 | 7.3 | Rolled Cuffs, Seamless Construction | 0000000 | 00000 |

For ASTM Voltage Rating | Lg. | Color | Choose a Size | Cannot Be Sold To | Pair | |
Cowhide Leather | ||||||
---|---|---|---|---|---|---|
Class 1, Class 3 | 13" | Red/Orange | __ | 00000000 | 000000 | |
Class 2 | 12" | Red/Orange | __ | 00000000 | 00000 | |
Class 2, Class 4 | 14" | Red/Orange | __ | 00000000 | 00000 | |
Goatskin Leather | ||||||
Class 00 | 10" | White | Canada | 00000000 | 00000 | |
Class 00, Class 0 | 13" | White | Canada | 00000000 | 00000 | |
Class 0 | 10" | White | Canada | 00000000 | 00000 |

For ASTM Voltage Rating | Each | |
Class 00, Class 0 | 0000000 | 0000000 |

Prevent damage to gloves in storage. Attach the bag to your belt with the quick-release snap hook. Grommets on the bottom provide ventilation and drainage.

For ASTM Voltage Rating | Each | |
Class 1, Class 2, Class 3, Class 4 | 0000000 | 0000000 |
Arc-Flash-Protection Equipment Kits


For protection from low-level arc flash hazards, these kits include several of the necessary safety items in a storage bag. All contents meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. All hard hats have a ratchet adjustment with an easy-turn knob.
Style A kits come with a hard hat, face shield, hood, safety glasses, and storage bag.
Style B kits come with coveralls, hard hat, face shield, hood, safety glasses, and two storage bags.When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.

Hard Hat | Face Shield | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Arc Rating, cal/cm2 | Arc Rated PPE Category | No. of Suspension Points | Material | Hat Size | Lens Material | Lens Ht. | Lens Wd. | Lens Thick. | Each | |
12 | 2 | 4 | Polyethylene Plastic | 6 1/2-8 | Polycarbonate Plastic | 10" | 11 1/2" | 0.06" | 0000000 | 0000000 |

Hard Hat | Face Shield | Coverall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Arc Rating, cal/cm2 | Arc Rated PPE Category | No. of Suspension Points | Material | Hat Size | Lens Material | Lens Ht. | Lens Wd. | Lens Thick. | Material | Choose a Size (Chest Size) | Each | |
8 | 2 | 4 | Polyethylene Plastic | 6 1/2-8 | Polycarbonate Plastic | 10" | 11 1/2" | 0.06" | Cotton/Nylon Fabric Blend | 000000 | 0000000 | |
12 | 2 | 4 | Polyethylene Plastic | 6 1/2-8 | Polycarbonate Plastic | 10" | 11 1/2" | 0.06" | Cotton/Nylon Fabric Blend | 000000 | 000000 |
Arc-Flash-Protection Hoods

These hoods meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 4. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. Each hood has a hard hat with adjustable headgear and a face shield with an antifog coating.
Optional fan (sold separately) mounts on your hood and pumps air inside using a fan motor. It operates on four AA batteries (not included).
Arc-Flash-Protection Face Shields

Provide protection from low-level arc flash hazards when a full hood is not necessary. These face shields meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. Meets ANSI/ISEA Z87.1 basic-impact standards when worn with safety glasses or goggles. The chin guard offers added protection. Hard hats have a ratchet adjustment with an easy-turn knob.
Flame- and Arc-Flash-Protection Knee Pads

These knee pads meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) Category 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. These pads have a hard plastic cap that reduces resistance, making it easy to slide on hard surfaces. They have two adjustable buckles to modify the fit.
Material | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Padding | Cover | Cap | Arc Rating, cal/cm2 | Arc Rated PPE Category | Padding Thick. | Closure Type | Specifications Met | Color | Size | Pair | |
Foam | Cotton Fabric | Plastic | 12.4 | 2 | 1/2" | Buckle | NFPA 70E | Black and Gray | One Size | 00000000 | 000000 |