For Manufacturer For Manufacturer |
---|
|
Manufacturer Manufacturer |
---|
|
Opening/Closing Action Opening/Closing Action |
---|
|
System of Measurement System of Measurement |
---|
|
For Door Swing Direction For Door Swing Direction |
---|
|
Opening/Closing Speed Opening/Closing Speed |
---|
|
Operation Type Operation Type |
---|
|
Useful Life Useful Life |
---|
|
Manufacturer Series Manufacturer Series |
---|
|
|
Mounting Hardware Included Mounting Hardware Included |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Door Closers
When replacing an existing closer, remove the cover and match the model number and/or mounting hole pattern to a closer in our offering. Or, use one of our closers and a universal mounting plate that matches most hole patterns.
If you are installing a new closer, choose one that works for your door width. Due to added resistance from wind, closers typically accommodate smaller exterior doors than interior doors.

There are three typical mounting positions for door closers; many of our closers are versatile and can be mounted in any of these positions. To determine opening direction, stand on the side of the door where the closer will be mounted. If the door opens towards you it opens in; opens away from you it opens out.
Door Mount, Opens In—Also known as regular arm mount, this position allows the door to open in toward the closer.
Door Mount, Opens Out—Also known as parallel arm mount, the arm lays parallel with the door in the closed position.
Frame Mount, Opens Out—Also known as top frame mount, this position is often used for exterior doors.
High-Traffic Door Closers



For frequently used doors, these closers last twice as long as standard door closers. They can replace Yale, Dorma, Falcon, Stanley, Parker, and Cal-Royal models with the same mounting hole pattern. All meet ANSI A156.4 Grade 1 durability, strength, and performance standards for door controls. Closers that meet UL 10C for fire-rated doors meet positive pressure fire test standards.
To determine door swing direction, stand on the side of the door where it swings away from you. If it opens to the right, select a right closer; if it opens to the left, select a left closer. Reversible closers are for right or left door-swing directions.
Free-moving closers pull doors shut after you've opened them.
Hold-open closers hold doors open until you close them with a slight push or pull on the door.
For Door Wd. | Opening Direction | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Door Mount | Frame Mount | Range of Motion | Mounting Hardware Included | Specifications Met | Choose a Finish | Each | |
Norton 1601 | |||||||||||
33"-52" | 30"-48" | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 180° | Yes | ADA Compliant ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 0000000 | |
33"-52" | 30"-48" | Reversible | Hold Open | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 1 | 00000000 | 000000 | |
Norton 7500 | |||||||||||
32"-54" | 30"-48" | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 000000 | |
32"-54" | 30"-48" | Reversible | Hold Open | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 1 | 00000000 | 000000 | |
Norton 8301 | |||||||||||
30"-48" | 30"-48" | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 000000 | |
30"-48" | 30"-48" | Reversible | Hold Open | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 1 | 00000000 | 000000 | |
Norton 8501 | |||||||||||
28"-48" | 28"-48" | Reversible | Free Moving | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
28"-48" | 28"-48" | Reversible | Hold Open | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
30"-48" | 30"-48" | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
30"-48" | 30"-48" | Reversible | Hold Open | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
Door Closers




These closers can replace Yale, Dorma, Falcon, Stanley, Parker, and Cal-Royal models with the same mounting hole pattern. They are reversible for right or left door-swing directions. All meet ANSI A156.4 Grade 2 or ANSI A156.4 Grade 3 durability, strength, and performance standards for door controls. Closers that meet UL 10C for fire-rated doors meet positive pressure fire test standards.
Free-moving closers pull doors shut after you've opened them.
Hold-open closers hold doors open until you close them with a slight push or pull on the door.
Door Closers | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Door Wd. | Opening Direction | Replacement Springs | |||||||||||
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Door Mount | Frame Mount | Range of Motion | Mounting Hardware Included | Specifications Met | Choose a Finish | Each | Each | ||
Norton 1700 | |||||||||||||
32"-42" | __ | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 3 UL 10C for Fire-Rated Doors UL Listed | 0000000 | 0000000 | 000000 | 00 | |
32"-42" | __ | Reversible | Hold Open | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 3 | 0000000 | 000000 | 000000 | 00 | |
Norton 9300 | |||||||||||||
35"-40" | 31"-34" | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 3 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 000000 | 000000 | 00 | |
35"-40" | 31"-34" | Reversible | Hold Open | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 3 | 00000000 | 000000 | 000000 | 00 | |
41"-48" | 35"-40" | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 3 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 000000 | 000000 | 00 | |
41"-48" | 35"-40" | Reversible | Hold Open | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 3 | 00000000 | 000000 | 000000 | 00 | |
Norton 78 | |||||||||||||
21"-42" | 21"-36" | Reversible | Free Moving | Opens Out | __ | 180° | Yes | ANSI A156.4 Grade 3 UL 10C for Fire-Rated Doors UL Listed | Bronze | 0000000 | 000000 | 00000000 | 0000000 |
21"-42" | 37"-44" | Reversible | Free Moving | Opens Out | __ | 180° | Yes | ANSI A156.4 Grade 3 UL 10C for Fire-Rated Doors UL Listed | Bronze | 0000000 | 000000 | 00000000 | 000000 |
30"-48" | 30"-36" | Reversible | Free Moving | Opens In | __ | 135° | Yes | ANSI A156.4 Grade 3 UL 10C for Fire-Rated Doors UL Listed | Bronze | 0000000 | 000000 | 00000000 | 000000 |
30"-48" | 37"-44" | Reversible | Free Moving | Opens In | __ | 135° | Yes | ANSI A156.4 Grade 3 UL 10C for Fire-Rated Doors UL Listed | Bronze | 0000000 | 000000 | 00000000 | 000000 |
Top Frame Mounting Brackets for 30"-48" Interior Door Wd. (Aluminum) | 0000000 | Each | 0000000 |
High-Traffic Door Closers with Shock-Absorbing Stop



To protect doors and walls, these closers have a shock-absorbing stop to damp the force of doors when they’re pushed open. Designed for frequently used doors, these last twice as long as standard door closers. They can replace Yale, Dorma, Falcon, Stanley, Parker, and Cal-Royal models with the same mounting hole pattern. These closers are reversible for right or left door-swing directions. All meet ANSI A156.4 Grade 1 durability, strength, and performance standards for door controls. Closers that meet UL 10C for fire-rated doors meet positive pressure fire test standards.
Free-moving closers pull doors shut after you've opened them.
Hold-open closers hold doors open until you close them with a slight push or pull on the door.
For Door Wd. | Opening Direction | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Door Mount | Frame Mount | Range of Motion | Mounting Hardware Included | Specifications Met | Choose a Finish | Each | |
Norton UNI 1601 | |||||||||||
28"-32" | 27" | Reversible | Free Moving | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 0000000 | |
28"-32" | 27" | Reversible | Hold Open | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 | 00000000 | 000000 | |
33"-41" | 28"-36" | Reversible | Free Moving | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 000000 | |
33"-41" | 28"-36" | Reversible | Hold Open | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 | 00000000 | 000000 | |
42"-48" | 28"-36" | Reversible | Free Moving | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 000000 | |
42"-48" | 28"-36" | Reversible | Hold Open | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 | 00000000 | 000000 | |
Norton UNI 7500 | |||||||||||
36"-36" | 36"-36" | Reversible | Free Moving | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
36"-36" | 36"-36" | Reversible | Hold Open | Opens Out | __ | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
Norton UNI 8301 | |||||||||||
36"-36" | 36"-36" | Reversible | Free Moving | Opens Out | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
36"-36" | 36"-36" | Reversible | Hold Open | Opens Out | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
Norton UNI 8501 | |||||||||||
36"-36" | 36"-36" | Reversible | Free Moving | Opens Out | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
36"-36" | 36"-36" | Reversible | Hold Open | Opens Out | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
High-Traffic Door Closers with Built-In Stop



A built-in stop prevents doors from opening too far—good when wall- or floor-stops can’t be used. Designed for frequently used doors, these closers last twice as long as standard door closers. They can replace Yale, Dorma, Falcon, Stanley, Parker, and Cal-Royal models with the same mounting hole pattern. These closers are reversible for right or left door-swing directions. All meet ANSI A156.4 Grade 1 durability, strength, and performance standards for door controls. Closers that meet UL 10C for fire-rated doors meet positive pressure fire test standards.
Free-moving closers pull doors shut after you've opened them.
Hold-open closers hold doors open until you close them with a slight push or pull on the door.
For Door Wd. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Door Mount Opening Direction | Range of Motion | Mounting Hardware Included | Specifications Met | Choose a Finish | Each | |
Norton CLP 1601 | ||||||||||
28"-48" | 28"-48" | Reversible | Free Moving | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 0000000 | |
28"-48" | 28"-48" | Reversible | Hold Open | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 | 00000000 | 000000 | |
Norton CLP 7500 | ||||||||||
30"-48" | 32"-48" | Reversible | Free Moving | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 000000 | |
30"-48" | 32"-48" | Reversible | Hold Open | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 | 00000000 | 000000 | |
Norton CLP 8301 | ||||||||||
28"-48" | 28"-48" | Reversible | Free Moving | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | 00000000 | 000000 | |
28"-48" | 28"-48" | Reversible | Hold Open | Opens Out | 110° | Yes | ANSI A156.4 Grade 1 | 00000000 | 000000 |
Universal-Mount Door Closers

No need to drill new holes—these closers have a mounting plate that fits the hole patterns of most closers from Norton, LCN, Yale, Corbin Russwin, and Dorma. Designed for frequently used doors, they last twice as long as standard door closers. These free-moving closers pull doors shut after you've opened them and are reversible for right or left door-swing directions. They meet ANSI A156.4 Grade 1 durability, strength, and performance standards for door controls. They also meet UL 10C for fire-rated doors, which meet positive pressure fire test standards.
For Door Wd. | Opening Direction | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Door Mount | Frame Mount | Range of Motion | Mounting Hardware Included | Specifications Met | Finish | Each | |
24"-48" | 24"-48" | Reversible | Free Moving | Opens In, Opens Out | Opens Out | 180° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Aluminum | 0000000 | 0000000 |
Universal Mounting Plates for Door Closers

When replacing door closers, these mounting plates let you match new closers to your existing hole patterns from most Corbin Russwin, Dorma, LCN, Norton, and Yale closers. They are reversible for right or left door-swing directions.
For Door Swing Direction | Lg. | Ht. | Material | Each | |
Reversible | 12 7/8" | 3 1/16" | Aluminum | 0000000 | 000000 |
Replacement Arms for Door Closers


Save time and money by replacing worn or damaged arms instead of the entire closer. These arms are reversible for right or left door-swing directions. All meet ANSI A156.4 Grade 1 durability, strength, and performance standards for door controls. They also meet UL 10C for fire-rated doors, which meet positive pressure fire test standards.
Use free-moving arms with free-moving closers that pull doors shut after you've opened them.
For Door Wd. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Interior | Exterior | For Door Swing Direction | Opening/Closing Action | Range of Motion | Mounting Hardware Included | Specifications Met | Finish | Each | |
Norton 1601 | |||||||||
33"-52" | 30"-48" | Reversible | Free Moving | 180° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 00000000 | 000000 |
Norton 8301 | |||||||||
30"-48" | 30"-48" | Reversible | Free Moving | 180° | Yes | ANSI A156.4 Grade 1 UL 10C for Fire-Rated Doors UL Listed | Gray | 000000000 | 00000 |
Replacement Covers for Door Closers


Make existing door closers with lost or damaged covers look new again.