Solenoid On/Off Valves with Flow Adjustment

- For Use With: Water
- Seal Material: EPDM Rubber
Turn the knob to adjust how much these valves will open or close when actuated. They are often used in irrigation and landscaping applications. All operate on electricity to automatically start and stop flow.
These valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Normally closed valves are closed unless actuated. Normally open valves are open unless actuated.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Gender | Thread Type | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Each | |
Nylon Plastic Body with Wire Leads | |||||||||
---|---|---|---|---|---|---|---|---|---|
Normally Closed—24V AC | |||||||||
1 | Female | NPT | 175 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 4 1/4" | 5 1/2" | 00000000 | 000000 |
1 1/2 | Female | NPT | 160 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 5 13/16" | 7 1/16" | 00000000 | 000000 |
2 | Female | NPT | 160 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 6 1/2" | 8 1/2" | 00000000 | 000000 |
Normally Closed—120V AC | |||||||||
1 | Female | NPT | 175 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 4 1/4" | 5 1/2" | 00000000 | 00000 |
1 1/2 | Female | NPT | 160 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 5 13/16" | 7 1/16" | 00000000 | 000000 |
2 | Female | NPT | 160 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 6 1/2" | 8 1/2" | 00000000 | 000000 |
Normally Open—24V AC | |||||||||
1 | Female | NPT | 175 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 4 1/4" | 5 15/16" | 00000000 | 000000 |
Normally Open—120V AC | |||||||||
1 | Female | NPT | 175 psi @ 70° F | Pressure Drop Assisted | 35° to 150° | 4 1/4" | 5 15/16" | 00000000 | 000000 |
Washdown-Resistant Electrically Operated Air Directional Control Valves

3-way valves create one action, such as extending a cylinder. 4-way valves create two actions, such as extending and then retracting a double-acting cylinder. 5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. Valves with spring return actuation go back to their original position when voltage is removed. Valves with electric (solenoid) return actuation go back to their original position when voltage moves from the first solenoid to the second solenoid. Valves with two exhaust ports allow you to independently control the speed of two different actions. Connect a flow control valve to each exhaust port. Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
O'all | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Directional Control Valve Type | Flow Pattern | No. of Flow Ports | No. of Exhaust Ports | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Lg. | Wd. | Ht. | Each | |
Single Solenoid—Spring Return Actuation | |||||||||||||
3-Way | 3/2 | 3 | 1 | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 68.58 mm | 0000000 | 0000000 |
4-Way | 5/2 | 5 | 2 | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 68.58 mm | 0000000 | 000000 |
4-Way | 5/3 (Closed Center) | 5 | 2 | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 68.58 mm | 0000000 | 000000 |
Double Solenoid—Electric (Solenoid) Return Actuation | |||||||||||||
4-Way | 5/2 | 5 | 2 | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 68.58 mm | 0000000 | 000000 |
O'all | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Directional Control Valve Type | Flow Pattern | No. of Flow Ports | No. of Exhaust Ports | For Inlet Tube OD | For Outlet Tube OD | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Lg. | Wd. | Ht. | Each | |
SingleSolenoid—Spring Return Actuation | |||||||||||||||
3-Way | 3/2 | 3 | 1 | 8 mm | 8 mm | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 76.2 mm | 0000000 | 0000000 |
4-Way | 5/2 | 5 | 2 | 8 mm | 8 mm | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 76.2 mm | 0000000 | 000000 |
4-Way | 5/3 (Closed Center) | 5 | 2 | 8 mm | 8 mm | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 76.2 mm | 0000000 | 000000 |
DoubleSolenoid—Electric (Solenoid) Return Actuation | |||||||||||||||
4-Way | 5/2 | 5 | 2 | 8 mm | 8 mm | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 76.2 mm | 0000000 | 000000 |