For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
For Container Size For Container Size |
---|
|
Housing Material Housing Material |
---|
|
Pump Type Pump Type |
---|
|
Flow Rate Flow Rate |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Intake Tube Type Intake Tube Type |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Piston Material Piston Material |
---|
|
Air Pressure Air Pressure |
---|
|
Spout Material Spout Material |
---|
|
Air Connection Gender Air Connection Gender |
---|
|
Air Connection Thread Type Air Connection Thread Type |
---|
|
Air Connection Type Air Connection Type |
---|
![]() | Pipe |
More
These pumps have a selectable flow rate, so you can adjust flow for different dispensing applications. A lever handle maximizes output with each stroke for low-effort dispensing.
Temp. Range, °F | Intake | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | For Discharge Tube ID | Spout Type | Each | |
Stainless Steel Intake Tube and Housing | ||||||||||||
6, 8, 10, 12 | 15-55 | 2,000 | Not Rated | 140° | 1 1/2 NPT, 2 NPT | Drum Connector | 1 1/8" | 18 1/2"-32 1/2" | 11/16" | Removable | 0000000 | 0000000 |
All of these pumps have bonding and grounding wires, while some also have an internal flame arrester, to pump fuel, cleaning solvents, and lacquer thinners.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Steel pumps work with fuels and flammable liquids, but not especially aggressive and corrosive chemicals.
Stainless steel pumps handle aggressive and corrosive liquids that steel pumps cannot.
Pumps for 5-gallon containers have a drum connector that fits Rieke flex spouts and four screw cap adapters: 1 3/4", 2 1/8", 2 1/4", and 2 7/8".
Repair kits include components such as extension tubes, gaskets, and pistons.
Intake | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Max. Temp. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Features | Each | |
Steel | ||||||||||
4 | 5 | 110 | Not Rated | 1 3/4", 2 1/4", 2 1/8", 2 7/8" | Drum Connector, Flex Spout Adapter, Four Screw Cap Adapters | 1/2" | 16" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 0000000 |
8 | 55 | 110 | Not Rated | 2 NPT | Drum Connector | 1/2" | 22" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
316 Stainless Steel | ||||||||||
12 | 5-7 | 650 | 140° F | 2 5/8", 2" | Drum Connector | 1 1/2" | 18" | Bonding and Grounding Wires | 0000000 | 000000 |
20 | 30-55 | 650 | 140° F | 2" | Drum Connector | 1 1/2" | 37 1/2" | Bonding and Grounding Wires | 0000000 | 000000 |
Repair Kit for Steel Pumps with 110 cP Max. Viscosity | 0000000 | Each | 0000000 |
Since these pumps use suction to draw liquid out of your container, they continue dispensing once you get them started. They're often used with coolant and water.
Temp. Range, °F | Intake | Discharge | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | ||
A | 2 | 5 | 150 | Not Rated | 140° | 11/16" | 16" | 9/16" | 11/16" | 21" | 0000000 | 00000 |
Use these pumps with fuel and flammable liquids, such as acetone, ethanol, and gasoline. They handle nearly twice the amount of pressure as other air-powered drum pumps to move high-viscosity liquids. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Air Connection | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
4 | 55 | 7,500 | 40° | 200° | 0-150 | 10 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 2 1/8" | 33 11/16" | 3/4 | Female | NPT | 0000000 | 000000000 |
Since these pumps move liquid by pressurizing your drum, they have few moving parts prone to wear and tear. They are often used with fuel and lubricating oil. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump. Pumps come set at 6 psi.
Temp. Range, °F | Air Connection | Intake | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Spout Type | Each | |
18 | 55 | 1,200 | Not Rated | 125° | 10-120 | 6 | 2 NPT | Air Hose Quick-Connect Coupling | 1/4 | Female | NPT | 1 1/4" | 21"-36" | Removable | 0000000 | 0000000 |
Hose with Nozzle | 000000 | Each | 0000000 |
These pumps have a motor that is rated for IEC Zone 1, Groups IIB and IIA; and IEC Zone 21, Groups IIIC, IIIB, and IIIA hazardous locations with flammable gases and vapors, so they can be used with liquids such as acetone, ethanol, methyl ethyl ketone (MEK), xylene, and mineral spirits. Motor is nonsparking for use in applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Each | |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 000000000 |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |