For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
For Container Size For Container Size |
---|
|
Housing Material Housing Material |
---|
|
Pump Type Pump Type |
---|
|
Maximum Flow Rate Maximum Flow Rate |
---|
Maximum Viscosity Maximum Viscosity |
---|
Maximum Temperature Maximum Temperature |
---|
|
For Drum Opening Size For Drum Opening Size |
---|
|
|
|
Minimum Temperature Minimum Temperature |
---|
|
|
Intake Tube Length Intake Tube Length |
---|
Intake Connection Style Intake Connection Style |
---|
|
More
More
More
More
Use these pumps to move lubricating oil, such as motor oil. Spout is removable and can be replaced with a garden hose.
Temp. Range, °F | Intake | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Spout Type | Each | |
16 | 15-55 | 316 | 50° | 110° | 2 NPT | Drum Connector | 1 1/2" | 37" | Removable | 0000000 | 000000 |
Push the plunger to pump water, cleaners, and chemicals.
Styles C-F are rated for liquids up to 2,500 centipoise.
Style C are often used as hand pumps and do not come with a connector. To attach them to a container, select an optional connector.
Temp. Range, °F | Intake | Discharge | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | For Use With | Min. | Max. | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
5 | 5-15 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Coolant, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Motor Oil, Nitric Acid, Phosphoric Acid, Salt Water, Sodium Hydroxide, Sulfuric Acid | 35° | 120° | 1/2" | 18" | 7/16" | 9/16" | 9" | 0000000 | 000000 |
Temp. Range, °F | Intake | Discharge | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | For Use With | Min. | Max. | For Drum Opening Size, mm | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
6 | 5 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Sulfuric Acid | 35° | 120° | 61 | Drum Connector | 1/2" | 14 1/2" | 7/16" | 9/16" | 36" | 0000000 | 000000 |
6 | 5 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Sulfuric Acid | 35° | 120° | 63 | Drum Connector | 1/2" | 14 1/2" | 7/16" | 9/16" | 36" | 0000000 | 00000 |
6 | 5 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Sulfuric Acid | 35° | 120° | 70 | Drum Connector | 1/2" | 14 1/2" | 7/16" | 9/16" | 36" | 0000000 | 00000 |
Temp. Range, °F | Intake | Discharge | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | For Use With | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
5 | 5-55 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Phosphoric Acid, Salt Water, Sodium Hydroxide, Sulfuric Acid | 35° | 120° | 2 NPT | Drum Connector | 9/16" | 36" | 7/16" | 9/16" | 9" | 0000000 | 000000 |
8 | 5-30 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Phosphoric Acid, Salt Water, Sodium Hydroxide, Sulfuric Acid | 35° | 120° | 2 NPT | Drum Connector | 1/2" | 18" | 7/16" | 9/16" | 48" | 0000000 | 00000 |
These pumps have a selectable flow rate, so you can adjust flow for different dispensing applications. A lever handle maximizes output with each stroke for low-effort dispensing.
Temp. Range, °F | Intake | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | For Discharge Tube ID | Spout Type | Each | |
Stainless Steel Intake Tube and Housing | ||||||||||||
6, 8, 10, 12 | 15-55 | 2,000 | Not Rated | 140° | 1 1/2 NPT, 2 NPT | Drum Connector | 1 1/8" | 18 1/2"-32 1/2" | 11/16" | Removable | 0000000 | 0000000 |
Remove liquid from hard-to-reach areas with a long, flexible intake tube that extends into deep and hard-to-access tanks.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with a PVC housing have a handle that acts as a siphon when fully extended.
Temp. Range, °F | Intake | Discharge | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | Max. Viscosity, cP | Min. | Max. | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
PVC Plastic Housing | ||||||||||
4 | 2,500 | 35° | 120° | 9/16" | 72" | 7/16" | 9/16" | 36" | 0000000 | 000000 |
All of these pumps have bonding and grounding wires, while some also have an internal flame arrester, to pump fuel, cleaning solvents, and lacquer thinners.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Steel pumps work with fuels and flammable liquids, but not especially aggressive and corrosive chemicals.
Stainless steel pumps handle aggressive and corrosive liquids that steel pumps cannot.
Pumps for 5-gallon containers have a drum connector that fits Rieke flex spouts and four screw cap adapters: 1 3/4", 2 1/8", 2 1/4", and 2 7/8".
Repair kits include components such as extension tubes, gaskets, and pistons.
Intake | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Max. Temp. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Features | Each | |
Steel | ||||||||||
4 | 5 | 110 | Not Rated | 1 3/4", 2 1/4", 2 1/8", 2 7/8" | Drum Connector, Flex Spout Adapter, Four Screw Cap Adapters | 1/2" | 16" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 0000000 |
4 | 5 | 650 | Not Rated | 1 3/4", 2 1/4", 2 1/8", 2 7/8" | Drum Connector, Flex Spout Adapter, Four Screw Cap Adapters | 1 1/8" | 15" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
8 | 15-55 | 650 | Not Rated | 2 NPT | Drum Connector | 9/16" | 16"-38" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
8 | 55 | 110 | Not Rated | 2 NPT | Drum Connector | 1/2" | 22" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
316 Stainless Steel | ||||||||||
12 | 5-7 | 650 | 140° F | 2 5/8", 2" | Drum Connector | 1 1/2" | 18" | Bonding and Grounding Wires | 0000000 | 000000 |
20 | 30-55 | 650 | 140° F | 2" | Drum Connector | 1 1/2" | 37 1/2" | Bonding and Grounding Wires | 0000000 | 000000 |
Since these pumps use suction to draw liquid out of your container, they continue dispensing once you get them started. They're often used with coolant and water.
Adjust pumps with a 5-7 gpm flow rate for different dispensing applications.
Temp. Range, °F | Intake | Discharge | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | ||
B | 5-7 | 5 | 650 | Not Rated | 140° | 2 NPS, 70 mm | Drum Connector | 1 1/2" | 16" | 1" | 1 1/4" | 60" | 0000000 | 000000 |
B | 5-7 | 5-6 | 650 | Not Rated | 140° | 2 NPS | Drum Connector | 1 1/2" | 16" | 1" | 1 1/4" | 60" | 0000000 | 00000 |
B | 5-7 | 15 | 650 | Not Rated | 140° | 2 NPS | Drum Connector | 1 1/2" | 24" | 1" | 1 1/4" | 60" | 0000000 | 00000 |
Use these pumps with fuel and flammable liquids, such as acetone, ethanol, and gasoline. They handle nearly twice the amount of pressure as other air-powered drum pumps to move high-viscosity liquids. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Air Connection | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
4 | 55 | 7,500 | 40° | 200° | 0-150 | 10 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 2 1/8" | 33 11/16" | 3/4 | Female | NPT | 0000000 | 000000000 |
With a nozzle and hose, these pumps allow you to dispense directly into your container. They move liquid by pressurizing the drum, so they have few moving parts prone to wear and tear. They are often used with fuel and lubricating oil. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump. Pumps come set at 6 psi.
Temp. Range, °F | Air Connection | Intake | Discharge (Hose and Nozzle) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | ID | Lg., ft. | Each | |
18 | 55 | 1,200 | Not Rated | 140° | 10-120 | 6 | 2 NPT | Air Hose Quick-Connect Coupling | 1/4 | Female | NPT | 1 1/4" | 21"-36" | 3/4" | 8 | 0000000 | 0000000 |
Replacement Hose with Nozzle | 000000 | Each | 0000000 |
Since these pumps move liquid by pressurizing your drum, they have few moving parts prone to wear and tear. They are often used with fuel and lubricating oil. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump. Pumps come set at 6 psi.
Temp. Range, °F | Air Connection | Intake | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Spout Type | Each | |
18 | 55 | 1,200 | Not Rated | 125° | 10-120 | 6 | 2 NPT | Air Hose Quick-Connect Coupling | 1/4 | Female | NPT | 1 1/4" | 21"-36" | Removable | 0000000 | 0000000 |
Hose with Nozzle | 000000 | Each | 0000000 |
These pumps have a motor that is rated for IEC Zone 1, Groups IIB and IIA; and IEC Zone 21, Groups IIIC, IIIB, and IIIA hazardous locations with flammable gases and vapors, so they can be used with liquids such as acetone, ethanol, methyl ethyl ketone (MEK), xylene, and mineral spirits. Motor is nonsparking for use in applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Each | |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 000000000 |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |
These pumps can be grounded to dissipate static electricity and are rated for use with flammable liquids such as gasoline, kerosene, isopropyl alcohol, and mineral spirits. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connections (NPT) | Discharge Pipe Connections (NPT) | Lg. | Wd. | Ht. | Each | |
231 ft. of Head—100 psi Max. Discharge Pressure | |||||||||||||
4 | 3.5 | 2 | 1 | 5,000 | 6 | 1/4 Female | 1/4 Female, 1/2 Male | 1/4 Female, 1/2 Male | 6" | 7" | 8" | 00000000 | 0000000 |
6.5 | 5.5 | 4 | 2.75 | 3,000 | 5.5 | 1/4 Female | 3/8 Female | 3/8 Female | 5" | 8" | 8" | 00000000 | 000000 |
14 | 12 | 8 | 5 | 10,000 | 16 | 1/4 Female | 1/2 Female, 1 Male | 1/2 Female, 1 Male | 7" | 10" | 12" | 00000000 | 00000000 |
Air Motor Repair Kit for 13465K38 | 0000000 | Each | 0000000 |
Fluid Side Repair Kit for 13465K38 | 0000000 | Each | 000000 |
Fluid Side Repair Kit for 13465K18 | 0000000 | Each | 000000 |
Air Motor Repair Kit for 13465K18 | 0000000 | Each | 000000 |
Air Motor Repair Kit for 13465K25 | 00000000 | Each | 000000 |
Fluid Side Repair Kit for 13465K25 | 00000000 | Each | 000000 |
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connections (NPT) | Discharge Pipe Connections (NPT) | Lg. | Wd. | Ht. | Each | |
288 ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
5.3 | 3.2 | 2.3 | 1.7 | Not Rated | 6.1 | 1/4 Female | 1/4 Female, 3/4 Male | 1/4 Female, 3/4 Male | 7" | 5" | 7" | 0000000 | 0000000 |
UL listed for pumping petroleum products and rated for use with flammable liquids, these pumps move diesel fuel, gasoline, kerosene, and mineral spirits. They can be grounded to dissipate static electricity. All have a pressure-relief valve set at 50 psi per UL 79 safety standard. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head | @ 100 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
115 Max. ft. of Head—50 psi Max. Discharge Pressure | ||||||||||||||
12 | 12 | 11.1 | 10.3 | 8.5 | 1,000 | 12 | 1/4 Female | 1/2 Female | 1/2 Female | 8" | 8" | 12" | 00000000 | 000000000 |
29 | 28 | 21 | 17 | 8 | 1,000 | 32 | 1/4 Female | 1 Female | 1 Female | 8" | 9" | 13" | 00000000 | 00000000 |
75 | 66 | 55 | 44 | 13 | 1,000 | 75 | 1/2 Female | 1 1/2 Female | 1 1/2 Female | 15" | 13" | 20" | 00000000 | 00000000 |
75 | 95 | 80 | 65 | 20 | 1,000 | 75 | 1/2 Female | 2 Female | 2 Female | 15" | 13" | 20" | 00000000 | 00000000 |
Air-Motor Maintenance Kit for 13455K36, 13455K37 and 13455K38 | 00000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 13455K36 | 00000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 13455K37 and 13455K38 | 00000000 | Each | 00000000 |
Air-Motor Maintenance Kit for 13455K41 | 00000000 | Each | 00000 |
Fluid-Side Maintenance Kit for 13455K41 | 00000000 | Each | 000000 |
With a 316 stainless steel housing and a PTFE diaphragm, these pumps resist a variety of acids, alkalies, and flammable liquids such as phosphoric acid, acetone, and methyl ethyl ketone (MEK). They're designed for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female | 1/2 Female | 9" | 10" | 10" | 00000000 | 000000000 |
45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 00000000 | 00000000 |
106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 00000000 | 00000000 |
150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 00000000 | 00000000 |
235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 00000000 | 000000000 |
Air-Motor Maintenance Kit for 41655K28 | 0000000 | Each | 0000000 |
Fluid-Side Maintenance Kit for 41655K28 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 41655K29, 41655K31, 41655K32 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 41655K29 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 41655K31 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 41655K32 | 0000000 | Each | 00000000 |
Air-Motor Maintenance Kit for 41655K27 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 41655K27 | 0000000 | Each | 000000 |
A neoprene diaphragm resists oil and chemicals such as isopropyl alcohol and deionized water. These pumps have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
15 | 12 | 10 | 7 | 1/8" | 10,000 | 20 | 1/4 Female | 1/2 Female, 1 Male | 1/2 Female, 1 Male | 9" | 10" | 12" | 0000000 | 000000000 |
These pumps have a PTFE diaphragm compatible with oil, fuel, and chemicals such as mineral spirits, methyl ethyl ketone (MEK), and xylene. They have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female, 1/2 Female | 1/2 Female, 1/2 Female | 9" | 10" | 12" | 0000000 | 000000000 |
45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 0000000 | 00000000 |
106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 0000000 | 00000000 |
150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 0000000 | 00000000 |
235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 0000000 | 00000000 |
Fluid-Side Maintenance Kit for 9948K21 | 0000000 | Each | 000000000 |
Air-Motor Maintenance Kit for 9948K21, 9948K23 and 9948K24 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K16 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K16 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K24 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 9948K23 | 0000000 | Each | 00000000 |
Pump fuel and flammable liquids, such as isopropyl alcohol and xylene. These pumps have an explosion-proof motor that is rated for environments where hazardous material is present. Maximum temperature is 250° F or the boiling point of the liquid being pumped, whichever is lower. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 7.4/3.7 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 2.4-2.2/1.1 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
100 | __ | 78 | 48 | 10 | 64 | 150 | 264 | 1 | 2.8/1.4 | 1 1/2 | 1 | 15 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
15 | __ | 10 | 4 | __ | 46 | 150 | 264 | 1/3 | 4.8/2.4 | 3/4 | 1/2 | 15 1/2" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
100 | 78 | 64 | 48 | 10 | 64 | 150 | 264 | 1 | 12/6 | 1 1/2 | 1 | 17 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
115 | __ | 100 | 90 | 60 | 81 | 150 | 264 | 1 1/2 | 5-4.6/2.3 | 1 1/2 | 1 | 16 3/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
125 | 114 | 98 | 78 | 18 | 69 | 150 | 264 | 2 | 5.7-5.4/2.7 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
140 | __ | __ | 120 | 47 | 75 | 150 | 264 | 3 | 8.1-7.6/3.8 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |