Push the plunger to pump water, cleaners, and chemicals.
Styles A and B are for thin liquids with a viscosity up to 700 centipoise.
Styles C-F are rated for liquids up to 2,500 centipoise.
Style C are often used as hand pumps and do not come with a connector. To attach them to a container, select an optional connector.
Temp. Range, °F | Intake | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | For Use With | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Discharge Location | Each | |
8 | 5-15 | 700 | Water, Deionized Water, Ethylene Glycol, Ammonium Hydroxide, Coolant, Hydraulic Oil, Hydrochloric Acid, Nitric Acid, Sodium Hydroxide | Not Rated | 120° | 2 NPT | Drum Connector | 1 1/2" | 22" | Spout End | 0000000 | 000000 |
22 | 15-55 | 700 | Water, Deionized Water, Ethylene Glycol, Ammonium Hydroxide, Coolant, Hydraulic Oil, Hydrochloric Acid, Nitric Acid, Sodium Hydroxide | Not Rated | 120° | 2 NPT | Drum Connector | 1 1/2" | 39" | Spout End | 0000000 | 00000 |
Temp. Range, °F | Intake | Discharge | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | For Use With | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
8 | 5-15 | 700 | Water, Deionized Water, Ethylene Glycol, Ammonium Hydroxide, Coolant, Hydraulic Oil, Hydrochloric Acid, Nitric Acid, Sodium Hydroxide | Not Rated | 120° | 2 NPT | Drum Connector | 1 1/2" | 22" | 7/16" | 5/8" | 22" | 0000000 | 000000 |
22 | 15-55 | 700 | Water, Deionized Water, Ethylene Glycol, Ammonium Hydroxide, Coolant, Hydraulic Oil, Hydrochloric Acid, Nitric Acid, Sodium Hydroxide | Not Rated | 120° | 2 NPT | Drum Connector | 1 1/2" | 39" | 7/16" | 5/8" | 36" | 0000000 | 00000 |
Temp. Range, °F | Intake | Discharge | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | For Use With | Min. | Max. | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
5 | 5-15 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Coolant, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Motor Oil, Nitric Acid, Phosphoric Acid, Salt Water, Sodium Hydroxide, Sulfuric Acid | 35° | 120° | 1/2" | 18" | 7/16" | 9/16" | 9" | 0000000 | 000000 |
Temp. Range, °F | Intake | Discharge | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | For Use With | Min. | Max. | For Drum Opening Size, mm | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
6 | 5 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Sulfuric Acid | 35° | 120° | 61 | Drum Connector | 1/2" | 14 1/2" | 7/16" | 9/16" | 36" | 0000000 | 000000 |
6 | 5 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Sulfuric Acid | 35° | 120° | 63 | Drum Connector | 1/2" | 14 1/2" | 7/16" | 9/16" | 36" | 0000000 | 00000 |
6 | 5 | 2,500 | Water, Deionized Water, Ethylene Glycol, Bleach, Diesel Fuel, Ethanol, Gasoline, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Mineral Spirits, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Sulfuric Acid | 35° | 120° | 70 | Drum Connector | 1/2" | 14 1/2" | 7/16" | 9/16" | 36" | 0000000 | 00000 |
A 316 stainless steel housing makes these pumps resistant to coolants such as ethylene glycol.
Repair kits include a gasket, a packing gland, a piston, a piston washer, and a push-on nut.
These pumps have a selectable flow rate, so you can adjust flow for different dispensing applications. A lever handle maximizes output with each stroke for low-effort dispensing.
Temp. Range, °F | Intake | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | For Discharge Tube ID | Spout Type | Each | |
Stainless Steel Intake Tube and Housing | ||||||||||||
6, 8, 10, 12 | 15-55 | 2,000 | Not Rated | 140° | 1 1/2 NPT, 2 NPT | Drum Connector | 1 1/8" | 18 1/2"-32 1/2" | 11/16" | Removable | 0000000 | 0000000 |
A lever handle maximizes output with each stroke for low-effort dispensing.
Style B pumps are for thin liquids with a viscosity up to 250 centipoise. They have a built-in drum connector.
Temp. Range, °F | Intake | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Style | Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Each | |
B | 11 | 15-55 | 250 | -15° | 150° | 2 NPT | Drum Connector | 1" | 19 3/4"-35 1/2" | 0000000 | 000000 |
Use these pumps with fuel and flammable liquids, such as acetone, ethanol, and gasoline. They handle nearly twice the amount of pressure as other air-powered drum pumps to move high-viscosity liquids. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Air Connection | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
4 | 55 | 7,500 | 40° | 200° | 0-150 | 10 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 2 1/8" | 33 11/16" | 3/4 | Female | NPT | 0000000 | 000000000 |
With a higher pressure than other air-powered drum pumps, these pumps move thick chemicals with a viscosity of up to 5,000 centipoise. A stainless steel housing stands up to acids, solvents, and other caustics. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Temp. Range, °F | Air Connection | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
4 | 5 | 5,000 | 35° | 120° | 180 | 1.5 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 2 1/8" | 10" | 3/4 | Female | NPT | 000000 | 000000000 |
4 | 55 | 5,000 | 35° | 120° | 180 | 1.5 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 2 1/8" | 36" | 3/4 | Female | NPT | 000000 | 00000000 |
A filter/lubricator ensures efficiency and reduces wear on the pump. They have a chemically resistant seal for use with hydraulic oil and motor oil in addition to acidic and alkaline liquids such as ammonia and etching and cleaning solutions. Pumps have a nonsparking motor for use in applications where electricity is unavailable or dangerous.
Temp. Range, °F | Air Connection | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Tube ID | Tube Lg., ft. | Features | Each | |
16 | 55 | 2,000 | -20° | 150° | 80-100 | 32 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 1 1/2" | 40" | 1" | 5 | 15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler | 0000000 | 0000000 |
16 | 55 | 2,000 | 35° | 150° | 80-100 | 32 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 1 5/8" | 40" | 1" | 5 | 15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler | 0000000 | 00000000 |
22 | 55 | 330 | 35° | 160° | 80-100 | 32 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 2" | 40" | 1" | 5 | 15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler | 0000000 | 000000 |
22 | 55 | 330 | 35° | 160° | 80-100 | 32 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 2" | 48" | 1" | 5 | 15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler | 0000000 | 00000000 |
These pumps have a motor that is rated for IEC Zone 1, Groups IIB and IIA; and IEC Zone 21, Groups IIIC, IIIB, and IIIA hazardous locations with flammable gases and vapors, so they can be used with liquids such as acetone, ethanol, methyl ethyl ketone (MEK), xylene, and mineral spirits. Motor is nonsparking for use in applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Each | |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 000000000 |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |
These pumps have a nonsparking air-powered motor for applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump. They're often used with ammonia, etching and cleaning solutions, and other caustics.
Temp. Range, °F | Air Connection | Intake | Discharge (Pump Body) | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
14 | 55 | 1,500 | -30° | 300° | 40-80 | 27 | 2 NPT | Drum Connector | 1/8 | Female | NPT | 1 1/2" | 39" | 3/4 | Female | NPT | 00000000 | 0000000 |
Temp. Range, °F | Air Connection | Intake | Discharge (Tube End) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | ID | Lg., ft. | Each | |
15 | 30 | 300 | 35° | 150° | 40 | 27 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 1 1/4" | 27" | 3/4" | 5 | 000000 | 0000000 |
15 | 55 | 300 | 35° | 150° | 40 | 27 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 1 1/4" | 40" | 3/4" | 5 | 000000 | 000000 |
Made of PVDF components, these pumps resist harsh chemicals such as hydrochloric acid and sulfuric acid. They have a foot pedal for hands-free operation. A telescoping intake tube works with containers of different heights.
Temp. Range, °F | Intake | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Each | |
5 | 30 | 500 | 35° | 100° | 1 1/8"-2 3/4" | Drum Connector | 5/8" | 27 1/2" | 0000000 | 0000000 |
With a 316 stainless steel housing and a PTFE diaphragm, these pumps resist a variety of acids, alkalies, and flammable liquids such as phosphoric acid, acetone, and methyl ethyl ketone (MEK). They're designed for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female | 1/2 Female | 9" | 10" | 10" | 00000000 | 000000000 |
45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 00000000 | 00000000 |
106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 00000000 | 00000000 |
150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 00000000 | 00000000 |
235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 00000000 | 000000000 |
Air-Motor Maintenance Kit for 41655K28 | 0000000 | Each | 0000000 |
Fluid-Side Maintenance Kit for 41655K28 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 41655K29, 41655K31, 41655K32 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 41655K29 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 41655K31 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 41655K32 | 0000000 | Each | 00000000 |
Air-Motor Maintenance Kit for 41655K27 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 41655K27 | 0000000 | Each | 000000 |
These pumps have a PTFE diaphragm compatible with oil, fuel, and chemicals such as mineral spirits, methyl ethyl ketone (MEK), and xylene. They have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female, 1/2 Female | 1/2 Female, 1/2 Female | 9" | 10" | 12" | 0000000 | 000000000 |
45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 0000000 | 00000000 |
106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 0000000 | 00000000 |
150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 0000000 | 00000000 |
235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 0000000 | 00000000 |
Fluid-Side Maintenance Kit for 9948K21 | 0000000 | Each | 000000000 |
Air-Motor Maintenance Kit for 9948K21, 9948K23 and 9948K24 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K16 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K16 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K24 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 9948K23 | 0000000 | Each | 00000000 |
With a 316 stainless steel housing and a fluoroelastomer diaphragm, these pumps resist a variety of harsh acids and alkalies, such as phosphoric acid, nitric acid, and sulfuric acid. They have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered transfer pumps. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
70 | 47 | 35 | 20 | Not Rated | 50 | 1/2 Female | 1 Female | 1 Female | 11" | 17" | 16" | 0000000 | 000000000 |
Also known as sprayer pumps, these provide a smooth, uniform flow for agricultural spraying, soap dispensing, and chemical transferring. They automatically turn on when you open the outlet valve. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Do not run dry.
Santoprene diaphragm stands up to ammonia and resists cracking for a long service life.
Fluoroelastomer diaphragm is compatible with many etching and cleaning solutions that have a low concentration of nitric acid.
Pumps | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Overall | Maintenance Kits for Pumps | |||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection | Intake Tube Connection | Discharge Tube Connection | Diaphragm Material | Lg. | Wd. | Ht. | Each | Each | ||
135 ft. of Head—58 psi Max. Discharge Pressure | |||||||||||||||
0.6 | 0.5 | 0.4 | 2,500 | 0.48 | 1/4" Male | 3/8" Male | 3/8" Male | Fluoroelastomer Rubber | 4" | 6" | 6" | 0000000 | 0000000 | 0000000 | 000000 |
0.6 | 0.5 | 0.4 | 2,500 | 0.48 | 1/4" Male | 3/8" Male | 3/8" Male | Santoprene Rubber | 4" | 6" | 6" | 0000000 | 000000 | 0000000 | 00000 |
For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,448 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | For Tube ID | Tube Connection Type | For Tube ID | Tube Connection Type | Lg. | Wd. | Ht. | Includes | Each | |
120V AC, Single Phase | |||||||||||||||
Plug | |||||||||||||||
2,448 | 20 | 1,000 | 35° to 160° | 1/4 hp | 3.1 | 1/2" | Barbed | 1/2" | Barbed | 10" | 5 1/2" | 10" | 10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61) | 0000000 | 0000000 |