For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
Maximum Flow Rate Maximum Flow Rate |
---|
Housing Material Housing Material |
---|
|
Power Source Power Source |
---|
|
Pump Type Pump Type |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Priming Type Priming Type |
---|
|
Diaphragm Material Diaphragm Material |
---|
|
Discharge Thread Type Discharge Thread Type |
---|
|
Maximum Viscosity Maximum Viscosity |
---|
|
|
Pump Style Pump Style |
---|
|
Maximum Feet of Head Maximum Feet of Head |
---|
|
Maximum Self-Priming Height Maximum Self-Priming Height |
---|
|
|
|
Air Connection Type Air Connection Type |
---|
![]() | Pipe |
More
More
More
These pumps can be grounded to dissipate static electricity and are rated for use with flammable liquids such as gasoline, kerosene, isopropyl alcohol, and mineral spirits. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connections (NPT) | Discharge Pipe Connections (NPT) | Lg. | Wd. | Ht. | Each | |
231 ft. of Head—100 psi Max. Discharge Pressure | |||||||||||||
4 | 3.5 | 2 | 1 | 5,000 | 6 | 1/4 Female | 1/4 Female, 1/2 Male | 1/4 Female, 1/2 Male | 6" | 7" | 8" | 00000000 | 0000000 |
6.5 | 5.5 | 4 | 2.75 | 3,000 | 5.5 | 1/4 Female | 3/8 Female | 3/8 Female | 5" | 8" | 8" | 00000000 | 000000 |
14 | 12 | 8 | 5 | 10,000 | 16 | 1/4 Female | 1/2 Female, 1 Male | 1/2 Female, 1 Male | 7" | 10" | 12" | 00000000 | 00000000 |
Air Motor Repair Kit for 13465K38 | 0000000 | Each | 0000000 |
Fluid Side Repair Kit for 13465K38 | 0000000 | Each | 000000 |
Fluid Side Repair Kit for 13465K18 | 0000000 | Each | 000000 |
Air Motor Repair Kit for 13465K18 | 0000000 | Each | 000000 |
Air Motor Repair Kit for 13465K25 | 00000000 | Each | 000000 |
Fluid Side Repair Kit for 13465K25 | 00000000 | Each | 000000 |
With a 316 stainless steel housing and a PTFE diaphragm, these pumps resist a variety of acids, alkalies, and flammable liquids such as phosphoric acid, acetone, and methyl ethyl ketone (MEK). They're designed for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female | 1/2 Female | 9" | 10" | 10" | 00000000 | 000000000 |
45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 00000000 | 00000000 |
106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 00000000 | 00000000 |
150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 00000000 | 00000000 |
235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 00000000 | 000000000 |
Air-Motor Maintenance Kit for 41655K28 | 0000000 | Each | 0000000 |
Fluid-Side Maintenance Kit for 41655K28 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 41655K29, 41655K31, 41655K32 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 41655K29 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 41655K31 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 41655K32 | 0000000 | Each | 00000000 |
Air-Motor Maintenance Kit for 41655K27 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 41655K27 | 0000000 | Each | 000000 |
A neoprene diaphragm resists oil and chemicals such as isopropyl alcohol and deionized water. These pumps have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Solids Dia. | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
15 | 12 | 10 | 7 | 1/8" | 10,000 | 20 | 1/4 Female | 1/2 Female, 1 Male | 1/2 Female, 1 Male | 9" | 10" | 12" | 0000000 | 000000000 |
45 | 38 | 30 | 19 | 1/4" | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 0000000 | 00000000 |
106 | 77 | 62 | 45 | 1/4" | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 0000000 | 00000000 |
150 | 104 | 76 | 53 | 1/4" | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 0000000 | 00000000 |
235 | 174 | 127 | 90 | 3/8" | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 0000000 | 00000000 |
Air-Motor Maintenance Kit for 9948K22, 9948K28 and 9948K26 | 0000000 | Each | 0000000 |
Fluid-Side Maintenance Kit for 9948K26 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K22 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K27 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K18 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K18 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K28 | 0000000 | Each | 00000000 |
These pumps have a PTFE diaphragm compatible with oil, fuel, and chemicals such as mineral spirits, methyl ethyl ketone (MEK), and xylene. They have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female, 1/2 Female | 1/2 Female, 1/2 Female | 9" | 10" | 12" | 0000000 | 000000000 |
45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 0000000 | 00000000 |
106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 0000000 | 00000000 |
150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 0000000 | 00000000 |
235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 0000000 | 00000000 |
Fluid-Side Maintenance Kit for 9948K21 | 0000000 | Each | 000000000 |
Air-Motor Maintenance Kit for 9948K21, 9948K23 and 9948K24 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K16 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K16 | 0000000 | Each | 000000 |
Air-Motor Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
Fluid-Side Maintenance Kit for 9948K24 | 0000000 | Each | 00000000 |
Fluid-Side Maintenance Kit for 9948K23 | 0000000 | Each | 00000000 |
Resistant to chemicals such as ammonia, detergents, and cleaning fluids, these pumps have a Santoprene diaphragm and polypropylene housing. They can be used to move thick sludges and slurries. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 120 ft.of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connections (NPT) | Discharge Pipe Connections (NPT) | Lg. | Wd. | Ht. | Each | |
231 Max. ft. of Head—100 psi Max. Discharge Pressure | |||||||||||||
4 | 3.5 | 2 | 1 | 5,000 | 6 | 1/4 Female | 1/4 Female, 1/2 Male | 1/4 Female, 1/2 Male | 6" | 7" | 8" | 0000000 | 0000000 |
14 | 12 | 8 | 5 | 10,000 | 16 | 1/4 Female | 1/2 Female, 1 Male | 1/2 Female, 1 Male | 7" | 10" | 12" | 0000000 | 000000 |
23 | 19 | 13 | 8 | 10,000 | 20 | 1/4 Female | 3/4 Female, 1 1/2 Male | 3/4 Female, 1 1/2 Male | 7" | 12" | 13" | 00000000 | 000000 |
Max. Flow Rate, gpm | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 40 Ft. of Head | @ 80 Ft. of Head | @ 120 Ft.of Head | @ 160 Ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connections (NPT) | Discharge Pipe Connections (NPT) | Lg. | Wd. | Ht. | Each | |
231 Max. ft. of Head—100 psi Max. Discharge Pressure | ||||||||||||||
7 | 7 | __ | 5 | 4 | 3,000 | 6 | 1/4 Female | 3/8 Female | 3/8 Female | 5" | 8" | 8" | 00000000 | 0000000 |
288 Max. ft. of Head—125 psi Max. Discharge Pressure | ||||||||||||||
5.3 | __ | 3.2 | 2.3 | 1.7 | Not Rated | 6.1 | 1/4 Female | 1/4 Female, 3/4 Male | 1/4 Female, 3/4 Male | 7" | 5" | 7" | 0000000 | 000000 |
A neoprene diaphragm stands up to oil and chemicals such as isopropyl alcohol and deionized water. These pumps have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered transfer pumps. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
70 | 47 | 35 | 20 | Not Rated | 50 | 1/2 Female | 1 Female | 1 Female | 11" | 17" | 16" | 0000000 | 000000000 |
140 | 120 | 96 | 77 | Not Rated | 150 | 3/4 Female | 2 Female | 2 Female | 14" | 22" | 20" | 0000000 | 00000000 |
Max. Flow Rate | Flange (Class 150) | Bolt | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 Feet of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Size | OD | Thick. | Circle Dia. | Size | Discharge Pipe Size | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||||||
260 | 178 | 150 | 118 | Not Rated | 120 | 3/4 Female | 3 | 7 1/2" | 7/8" | 6" | 5/8" | 3 | 16" | 37" | 30" | 0000000 | 000000000 |
With a 316 stainless steel housing and a fluoroelastomer diaphragm, these pumps resist a variety of harsh acids and alkalies, such as phosphoric acid, nitric acid, and sulfuric acid. They have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered transfer pumps. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
70 | 47 | 35 | 20 | Not Rated | 50 | 1/2 Female | 1 Female | 1 Female | 11" | 17" | 16" | 0000000 | 000000000 |
The fluoroelastomer diaphragm withstands higher temperatures than a neoprene diaphragm and has better resistance to fuel such as gasoline and kerosene. These pumps have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered transfer pumps. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
Max. Flow Rate, gpm | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Maximum Viscosity | Air Consumption, cfm | Air Connection | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
70 | 47 | 35 | 20 | Not Rated | 50 | 1/2 Female | 1 Female | 1 Female | 11" | 17" | 16" | 0000000 | 000000000 |
140 | 120 | 96 | 77 | Not Rated | 150 | 3/4 Female | 2 Female | 2 Female | 14" | 22" | 20" | 0000000 | 00000000 |