Type Type |
---|
![]() | ![]() |
Receptacle | Plug |
Shape Shape |
---|
![]() | Straight |
Color Color |
---|
![]() | Black |
Connection Type Connection Type |
---|
![]() | ![]() |
Straight Blade | Vehicle |
Current Current | Show |
---|
|
Current Current | Hide |
---|
Wire Connection Type Wire Connection Type |
---|
![]() | ![]() |
Screw Terminals | Quick- Disconnect Terminals |
![]() | |
Solder |
Mounting Location Mounting Location |
---|
|
Grounding Grounding |
---|
![]() | ![]() |
Grounded | Non-Grounded |
For Panel Cutout Height For Panel Cutout Height |
---|
|
|
|
Specifications Met Specifications Met |
---|
|
For Panel Cutout Width For Panel Cutout Width |
---|
|
|
|
Maximum Temperature Maximum Temperature |
---|
|
More
More
Pair these connectors with standard IEC power cords to bring power into or out of your electronic devices. Often used to convey power from wall outlets, there’s no need to wire your devices to an external power source. Instead, wire these connectors into your device with the terminals on the back of each connector. Most meet U.S. or international standards for safety.
Receptacles are often installed in electrical devices. Most also include shock protection. Class I shock protection means they're insulated and have a protective ground to prevent electrical shocks. Class II shock protection means there are two levels of insulation to prevent electrical shocks. Male receptacles are commonly used to bring power into an electronic device. Some accept a fuse to prevent short circuits and circuit overloads from damaging your devices. The fuses are sold separately. Female receptacles are frequently used to bring power out of one electronic device and into another. C13 receptacles are also known as Sheet F outlets. Screw-on connectors mount to devices with any panel thickness, as long as you can drill mounting holes into the device. Snap-in connectors mount to devices with snap-in tabs—no fasteners needed—but require a specific panel thickness and a precisely cut hole for secure mounting.
Solder terminal wire connections are more secure than screw and quick-disconnect terminal connections. Quick-disconnect terminal wire connections are faster to wire than screw and solder terminal connections. The terminals slide together with the quick-disconnect terminals on your wiring and are easily disconnected by hand, but still provide a strong hold.
IP-rated connectors meet standards for protecting you from making contact with a live circuit. The larger the first digit, the smaller the object it protects against. An IP30 rating means screwdrivers and other objects larger than 2.5 mm won't get in. And an IP40 rating means wire and other objects larger than 1 mm won't get in.
Connectors with a UL 94 rating have passed one of UL's flame tests. UL 94V0 means they self-extinguish within 10 seconds if they catch fire and won’t spread flames from dripping. UL 94V2 means they self-extinguish within 30 seconds if they catch fire, but may drip flaming particles.
For technical drawings and 3-D models, click on a part number.
For Fuse | For Panel Cutout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | O'all Lg., mm | O'all Dia., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | Each | |
Solder Terminals | |||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.24" | -10° to 155° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.83" | 1.12" | 0.31" | -10° to 155° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.1" | 0.314" | -10° to 245° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C18 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.1" | -10° to 155° | IP40 | II | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C18 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.83" | 1.12" | 0.31" | -10° to 155° | IP40 | II | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
Quick-Disconnect Terminals | |||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.24" | -10° to 155° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.83" | 1.12" | 0.31" | -10° to 155° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.1" | 0.314" | -10° to 245° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16A | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.787" | 1.08" | 0.314" | -10° to 310° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C18 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.1" | -10° to 155° | IP40 | II | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C18 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.83" | 1.12" | 0.31" | -10° to 155° | IP40 | II | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
For Fuse | For Panel Cutout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | O'all Lg., mm | O'all Dia., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | Each | |
Solder Terminals | |||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.098" | -10° to 155° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.118" | -10° to 155° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.06" | 0.031"-0.059" | __ | __ | I | UL Recognized, CSA Certified, VDE Certified | 0000000 | 000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.098" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.118" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.059" | -10° to 245° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.098" | -10° to 245° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.118" | -10° to 245° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C18 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.06" | -10° to 155° | IP30 | II | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
Quick-Disconnect Terminals | |||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | __ | __ | 1.07" | 1 1/4" | 0.031"-0.079" | __ | __ | I | UL Recognized, CSA Certified, VDE Certified | 0000000 | 0000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | __ | __ | 1.24" | 1.07" | 0.03"-0.08" | __ | __ | I | UL Recognized, CSA Certified, VDE Certified | 0000000 | 0000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.098" | -10° to 155° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 20 | 5 | 1.24" | 1.08" | 0.118" | -10° to 155° | IP40 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.098" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.118" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.81" | 1.06" | 0.031"-0.059" | __ | __ | I | UL Recognized, CSA Certified, VDE Certified | 0000000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.059" | -10° to 245° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.098" | -10° to 245° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.118" | -10° to 245° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16A | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.787" | 1.08" | 0.059" | -10° to 310° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C16A | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.787" | 1.08" | 0.118" | -10° to 310° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C18 | 250V AC | 15A (UL), 10A (IEC) | __ | __ | 0.79" | 1.08" | 0.06" | -10° to 155° | IP30 | II | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | Each | |
Solder Terminals | |||||||||||
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.31" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 00000 |
Quick-Disconnect Terminals | |||||||||||
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.31" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Environmental Rating | Shock Protection Class | Specifications Met | Each | |
Solder Terminals | |||||||||||
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.28" | 0.031"-0.079" | __ | __ | I | UL Recognized, CSA Certified, UL 94V2 | 0000000 | 00000 |
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.1" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.11" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
Quick-Disconnect Terminals | |||||||||||
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.28" | 0.031"-0.079" | __ | __ | I | UL Recognized, CSA Certified, UL 94V0, VDE Certified | 0000000 | 0000 |
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.1" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
C13 | 250V AC | 15A (UL), 10A (IEC) | 1" | 1.3" | 0.11" | -10° to 155° | IP30 | I | UL Recognized, C-UL Recognized, CE Marked, CSA Certified, UL 94V0, ENEC Marked | 0000000 | 0000 |
Instead of hardwiring power supplies, appliances, and other electronic devices, these connectors let you plug in an IEC power cord and turn the power on and off without needing a separate switch. Wire these connectors using the quick-disconnect terminals; they slide together with matching terminals on your wiring for a secure hold that's also easy to pull apart to make repairs. The terminals are on the back of the connector, so the wiring stays inside your device.
Rated IP40, these connectors prevent objects larger than a 1 mm-wd. wire from touching internal components and accidentally shocking you. With Class I shock protection, they’re insulated and have a protective ground. Some have a fuse drawer to hold a fuse, which prevents short circuits and circuit overloads from damaging your device. The fuses are sold separately.
These connectors meet UL 94V0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. They’re also UL and C-UL recognized, CE and ENEC marked, and CSA certified, so they meet stringent safety standards.
Screw-on connectors mount to housings of any thickness, as long as you can drill mounting holes into them. Snap-in connectors have tabs on the side to mount to housings without using fasteners. But, they require a specific panel thickness and precisely cut hole for secure mounting.
Connectors with an indicator light on their switch show if your device is powered on.
Shielded connectors protect against interference from nearby equipment.
For technical drawings and 3-D models, click on a part number.
For Fuse | For Panel Cutout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | No. of Circuits Controlled | Switch Starting Position | Industry Designation | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Each | |
Screw On | |||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.11" | 1.85" | 0.314" | -10° to 185° | 0000000 | 000000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 1 Off (Normally Open) | SPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | 00000000 | 00000 |
Snap In | |||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.88" | 1.13" | 0.039", 0.059", 0.079", 0.098" | 0° to 155° | 0000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | 00000000 | 00000 |
For Fuse | For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Switch Starting Position | Industry Designation | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Each | |
Snap In | ||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.88" | 1.13" | 0.039", 0.059", 0.079", 0.098" | 0° to 155° | 0000000 | 000000 |
For Fuse | For Panel Cutout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | No. of Circuits Controlled | Switch Starting Position | Industry Designation | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Each | |
Green Indicator | |||||||||||||
Screw On | |||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.11" | 1.85" | 0.314" | -10° to 185° | 0000000 | 000000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | 00000000 | 00000 |
Snap In | |||||||||||||
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | 00000000 | 00000 |
Red Indicator | |||||||||||||
Screw On | |||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 5 | 20 | 1.11" | 1.85" | 0.314" | -10° to 185° | 0000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | __ | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.24" | -10° to 155° | 00000000 | 00000 |
Snap In | |||||||||||||
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.059" | -10° to 155° | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | 1.24" | 1.09" | 0.098" | -10° to 155° | 00000000 | 00000 |
For Fuse | ||||
---|---|---|---|---|
For No. of Fuses | O'all Dia., mm | O'all Lg., mm | Each | |
2 | 5 | 20 | 00000000 | 00000 |
Rated IP67, these connectors create a dust- and watertight seal where they fit into the housing of power supplies, appliances, and other electronic devices. Instead of hardwiring your devices, these connectors let you plug in a standard IEC power cord and turn the power on and off with a built-in switch. Wire these connectors using the quick-disconnect terminals; they slide together with matching terminals on your wiring for a secure hold that's also easy to pull apart to make repairs. The terminals are on the back of the connector, so the wiring stays inside your device.
To protect your devices, these connectors have a thermal circuit breaker that uses the excess heat when there’s overcurrent to trip the breaker and cut power. If there’s a short circuit, the breakers can safely stop up to a 2,000-Amp breakthrough current. These connectors also have Class I shock protection, so they’re insulated and have a protective ground.
These connectors meet UL 94V0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. They’re also UL and C-UL recognized, and CE and ENEC marked, so they meet stringent safety standards.
For technical drawings and 3-D models, click on a part number.
UL Rating | IEC Rating | For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Current, A | Voltage | Frequency, Hz | Voltage | Frequency, Hz | No. of Circuits Controlled | Switch Starting Position | Industry Designation | Ht. | Wd. | Temp. Range, °F | Each | |
Male Receptacles | |||||||||||||
Screw On | |||||||||||||
C14 | 10 | 250V AC | 60 | 250V AC | 50 | 2 | 2 Off (Normally Open) | DPST-NO | 2.32" | 1.35" | -10° to 140° | 00000000 | 000000 |
Bring power into electronic devices while protecting them from harmful electromagnetic interference (EMI). All of these connectors are compatible with standard IEC power cords. Often used to convey power from wall outlets, there’s no need to wire your devices to an external power source. Instead, wire these connectors into your device with the terminals on the back of each connector. When selecting a connector, make sure the current is at or slightly above the requirements of your device for the best EMI-filtering performance.
All of these connectors meet U.S. and international standards for safety. They also meet UL 94V0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. Rated IP40, these connectors prevent objects larger than 1 mm, such as wire, from making contact with a live circuit and shocking you. They also include shock protection. Class I shock protection means they're insulated and have a protective ground to prevent electrical shocks.
Screw-on connectors mount to devices with any panel thickness, as long as you can drill mounting holes into the device. Snap-in connectors mount to devices with snap-in tabs—no fasteners needed—but require a specific panel thickness and a precisely cut hole for secure mounting.
Quick-disconnect terminal wire connections are faster to wire than solder terminal connections. The terminals slide together with the quick-disconnect terminals on your wiring and are easily disconnected by hand, but still provide a strong hold.
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Shock Protection Class | Specifications Met | Each | |
Quick-Disconnect Terminals | ||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 0.85" | 1.14" | 0.315" | -10° to 185° | I | UL Recognized, C-UL Recognized, CE Marked, UL 94V0, ENEC Marked | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 0.85" | 1.14" | 0.315" | -10° to 185° | I | UL Recognized, C-UL Recognized, CE Marked, UL 94V0, ENEC Marked | 00000000 | 0000 |
For Panel Cutout | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Shock Protection Class | Specifications Met | Each | |
Quick-Disconnect Terminals | ||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 0.85" | 1.16" | 0.032"-0.079" | -10° to 185° | I | UL Recognized, C-UL Recognized, CE Marked, UL 94V0, ENEC Marked | 00000000 | 00000 |
C14 | 250V AC | 15A (UL), 10A (IEC) | 0.85" | 1.16" | 0.032"-0.079" | -10° to 185° | I | UL Recognized, C-UL Recognized, CE Marked, UL 94V0, ENEC Marked | 00000000 | 0000 |
With a built-in switch, these connectors run power to appliances, power supplies, and other electronic devices while also filtering damaging EMI (electromagnetic interference). Instead of hardwiring your devices, add these connectors and plug in a standard IEC power cord. Wire these connectors using the quick-disconnect terminals; they slide together with matching terminals on your wiring for a secure hold that's also easy to pull apart to make repairs. The terminals are on the back of the connector, so the wiring stays inside your device. For the best EMI-filtering performance, choose a connector with a current rating at or slightly above your device's current requirements.
Rated IP40, these connectors prevent objects larger than a 1 mm-wd. wire from touching internal components and accidentally shocking you. With Class I shock protection, they’re insulated and have a protective ground. Some have a fuse drawer to hold a fuse, which prevents short circuits and circuit overloads from damaging your device. The fuses are sold separately.
These connectors meet UL 94V0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. They’re also UL and C-UL recognized, ENEC marked, and CSA certified, so they meet stringent safety standards.
Screw-on connectors mount to housings of any thickness, as long as you can drill mounting holes into them. Snap-in connectors have tabs on the side to mount to housings without using fasteners. But, they require a specific panel thickness and precisely cut hole for secure mounting.
Shielded connectors protect against interference from nearby equipment.
For Fuse | For Panel Cutout | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | No. of Circuits Controlled | Switch Starting Position | Industry Designation | For No. of Fuses | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Each | |
Screw On | ||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | __ | 1.31" | 1.15" | 0.314" | -10° to 185° | 00000000 | 000000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | __ | 1.31" | 1.15" | 0.314" | -10° to 185° | 00000000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.17" | 1.94" | 0.314" | -10° to 185° | 0000000 | 00000 |
Snap In | ||||||||||||||
C14 | 250V AC | 10A (UL), 10A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | __ | 1.3" | 1.16" | 0.039"-0.118" | -10° to 185° | 00000000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | __ | 1.3" | 1.16" | 0.039"-0.118" | -10° to 185° | 00000000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.16" | 1.94" | 0.039"-0.118" | -10° to 185° | 0000000 | 00000 |
C14 | 250V AC | 10A (UL), 10A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.88" | 1.13" | 0.039", 0.059", 0.079", 0.098" | -10° to 185° | 0000000 | 00000 |
For Fuse | ||||
---|---|---|---|---|
For No. of Fuses | O'all Dia, mm | O'all Lg., mm | Each | |
2 | 5 | 20 | 00000000 | 00000 |
Distribute power from one electronic device to several others with these connectors. By housing multiple outlets in a single unit, they save space and time spent on installation. They’re compatible with IEC power cords, which are the industry standard for power connections. The outlets are C13 receptacles, also known as Sheet F outlets.
Wire these connectors into your device with the terminals on the back of each outlet. They mount to your device with snap-in tabs—no fasteners needed—but require a specific panel thickness and a precisely cut hole for secure mounting.
All meet international standards for safety. They are rated for Class I Shock Protection, meaning they have insulation and a protective ground.
Solder connections are more secure than quick-disconnect terminals. These connectors meet UL 94V2, which means they’ll self-extinguish within 30 seconds if they catch fire, but may drip flaming particles.
Quick-disconnect terminals are faster to wire than solder connections. The terminals slide together with the quick-disconnect terminals on your wiring and are easily disconnected by hand, but still provide a strong hold. Rated IP30, these connectors prevent objects larger than 2.5 mm, such as screwdrivers, from making contact with a live circuit and shocking you. They also meet UL 94V0, so they’ll self-extinguish within 10 seconds if they catch fire and won’t spread flames from dripping.
For technical drawings and 3-D models, click on a part number.
UL Rating | TUV Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 1.9" | 1.3" | 0.05"-0.07" | 15° to 155° | Black | 0000000 | 00000 |
UL Rating | TUV Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 2.8" | 1.3" | 0.05"-0.07" | 15° to 155° | Black | 0000000 | 00000 |
![]() Quad | ![]() IEC C13 Outlet |
![]() Solder Connect |
UL Rating | TUV Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 3.8" | 1.3" | 0.05"-0.07" | 15° to 155° | Black | 0000000 | 00000 |
UL Rating | IEC Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 3.8" | 1.3" | 0.06" | 15° to 155° | Black | 0000000 | 000000 |
![]() Five | ![]() IEC C13 Outlet |
![]() Solder Connect |
UL Rating | TUV Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 4.7" | 1.3" | 0.05"-0.07" | 15° to 155° | Black | 0000000 | 00000 |
![]() Six | ![]() IEC C13 Outlet |
![]() Solder Connect |
UL Rating | TUV Rating | For Panel | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | ||||||||||||
C13 | 250V AC | 15 | 60 | 10 | 50 | 5.7" | 1.3" | 0.05"-0.07" | 15° to 155° | Black | 0000000 | 00000 |
Send power to your device using the inlet, then route power to another device through the outlet—all with standard IEC power cords. Compared to using separate receptacles, these combination connectors are quicker to install and have a more streamlined appearance. Snap the connector into your panel—tabs on the side hold them in place without needing fasteners. Then solder your power supply to the wire terminals for a secure, permanent bond. C13 receptacles are also known as Sheet F outlets.
Rated IP30, these connectors prevent objects greater than 2.5mm wide, such as screwdrivers, from touching internal components and accidentally shocking you. With Class I shock protection, they’re insulated and have a protective ground.
These connectors meet UL 94 V-0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. They’re also UL recognized, CE marked, CSA certified, and ENEC marked, so you know they meet stringent safety standards.
For technical drawings and 3-D models, click on a part number.
UL Rating | IEC Rating | For Panel | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current, A | Frequency, Hz | Voltage | Current, A | Frequency, Hz | Cutout Ht. | Cutout Wd. | Thick. | Temp. Range, °F | Color | Each | |
Grounded | |||||||||||||
C13 (Female), C14 (Male) | 125V AC | 15 | 60 | 250V AC | 10 | 50 | 2" | 1.3" | 0.03"-0.08" | -10° to 155° | Black | 0000000 | 00000 |
Power ancillary devices, such as chargers for electronics, from a vehicle. When used together, the plug and socket create a moisture-resistant seal. Used separately, they are compatible with devices that have standard 12-volt plugs and sockets. All have a moisture-proof, corrosion-resistant housing.
For technical drawings and 3-D models, click on a part number.
Voltage | Current | For No. of Wires | Wire Connection Type | For Wire Gauge | For Cable OD | OD | Lg. | Color | Features | Temp. Range, °F | Each | |
12V DC | 10A | 2 | Screw Terminals | 16 | 0.2"-0.31" | 0.9" | 3.7" | Black | Power-Indicating Light | -5° to 265° | 000000 | 000000 |
Plug these cords into a vehicle outlet to power a device from the vehicle's battery. The connectors resists moisture and corrosion. An attached cap seals out water when the extension cord is not in use.
Lg., ft. | Retracted Lg. | Wire Gauge | Current, A | Voltage | Power-Indicating Light | Color | Each | |
Vehicle Plug × Vehicle Socket | ||||||||
---|---|---|---|---|---|---|---|---|
6 | 14" | 18 | 10 | 12V DC | Without Power-Indicating Light | Black | 000000 | 000000 |