Type Type |
---|
![]() | Receptacle |
Shape Shape |
---|
![]() | Straight |
Color Color |
---|
![]() | Black |
Connection Type Connection Type |
---|
![]() | Straight Blade |
Current Current | Show |
---|
|
Current Current | Hide |
---|
IEC Style IEC Style |
---|
![]() | C14 |
Wire Connection Type Wire Connection Type |
---|
![]() | Quick-Disconnect Terminals |
Gender Gender |
---|
|
Number of Blades Number of Blades |
---|
|
Shock Protection Class Shock Protection Class |
---|
|
Terminal Thickness Terminal Thickness |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Mounting Location Mounting Location |
---|
|
Receptacle Type Receptacle Type |
---|
![]() | Single |
More
Bring power into electronic devices while protecting them from harmful electromagnetic interference (EMI). All of these connectors are compatible with standard IEC power cords. Often used to convey power from wall outlets, there’s no need to wire your devices to an external power source. Instead, wire these connectors into your device with the terminals on the back of each connector. When selecting a connector, make sure the current is at or slightly above the requirements of your device for the best EMI-filtering performance.
All of these connectors meet U.S. and international standards for safety. They also meet UL 94V0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. Rated IP40, these connectors prevent objects larger than 1 mm, such as wire, from making contact with a live circuit and shocking you. They also include shock protection. Class I shock protection means they're insulated and have a protective ground to prevent electrical shocks.
Screw-on connectors mount to devices with any panel thickness, as long as you can drill mounting holes into the device. Snap-in connectors mount to devices with snap-in tabs—no fasteners needed—but require a specific panel thickness and a precisely cut hole for secure mounting.
Quick-disconnect terminal wire connections are faster to wire than solder terminal connections. The terminals slide together with the quick-disconnect terminals on your wiring and are easily disconnected by hand, but still provide a strong hold.
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Shock Protection Class | Specifications Met | Each | |
Quick-Disconnect Terminals | ||||||||||
C14 | 250V AC | 2A (UL), 2A (IEC) | 0.85" | 1.14" | 0.315" | -10° to 185° | I | UL Recognized, C-UL Recognized, CE Marked, UL 94V0, ENEC Marked | 00000000 | 00000 |
For Panel Cutout | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Shock Protection Class | Specifications Met | Each | |
Quick-Disconnect Terminals | ||||||||||
C14 | 250V AC | 2A (UL), 2A (IEC) | 0.85" | 1.16" | 0.032"-0.079" | -10° to 185° | I | UL Recognized, C-UL Recognized, CE Marked, UL 94V0, ENEC Marked | 00000000 | 00000 |
IP rated for dusty and wet environments, these connectors bring power into electronic devices while protecting them from harmful electromagnetic interference (EMI). All are for use with standard IEC power cords. Commonly used to convey power from wall outlets, you won’t have to wire your devices to an external power source. Instead, wire these connectors into your device with the terminals on the back of each connector. When selecting a connector, make sure the current is at or slightly above the requirements of your device for the best EMI-filtering performance.
All of these connectors include fuses to prevent short circuits and circuit overloads from damaging your devices. For fast wire connections, they have quick-disconnect terminals. The terminals slide together with the quick-disconnect terminals on your wiring and are easily disconnected by hand, but still provide a strong hold.
These connectors meet U.S. and international standards for safety. They also meet UL 94V0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. All have Class I shock protection—they're insulated and have a protective ground to prevent electrical shocks.
For technical drawings and 3-D models, click on a part number.
UL Rating | IEC Rating | For Panel Cutout | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Current, A | Voltage | Frequency, Hz | Voltage | Frequency, Hz | Fuses Included | Ht. | Wd. | Temp. Range, °F | Each | |
Male Receptacles | |||||||||||
C14 | 2 | 250V AC | 60 | 250V AC | 50 | Yes | 1.27" | 1.15" | -10° to 185° | 00000000 | 000000 |
With a built-in switch, these connectors run power to appliances, power supplies, and other electronic devices while also filtering damaging EMI (electromagnetic interference). Instead of hardwiring your devices, add these connectors and plug in a standard IEC power cord. Wire these connectors using the quick-disconnect terminals; they slide together with matching terminals on your wiring for a secure hold that's also easy to pull apart to make repairs. The terminals are on the back of the connector, so the wiring stays inside your device. For the best EMI-filtering performance, choose a connector with a current rating at or slightly above your device's current requirements.
Rated IP40, these connectors prevent objects larger than a 1 mm-wd. wire from touching internal components and accidentally shocking you. With Class I shock protection, they’re insulated and have a protective ground. Some have a fuse drawer to hold a fuse, which prevents short circuits and circuit overloads from damaging your device. The fuses are sold separately.
These connectors meet UL 94V0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. They’re also UL and C-UL recognized, ENEC marked, and CSA certified, so they meet stringent safety standards.
Screw-on connectors mount to housings of any thickness, as long as you can drill mounting holes into them. Snap-in connectors have tabs on the side to mount to housings without using fasteners. But, they require a specific panel thickness and precisely cut hole for secure mounting.
Connectors with an indicator light on their switch show if your device is powered on.
Shielded connectors protect against interference from nearby equipment.
For Fuse | For Panel Cutout | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | No. of Circuits Controlled | Switch Starting Position | Industry Designation | For No. of Fuses | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Each | |
Screw On | ||||||||||||||
C14 | 250V AC | 2A (UL), 2A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | __ | 1.31" | 1.15" | 0.314" | -10° to 185° | 00000000 | 000000 |
C14 | 250V AC | 2A (UL), 2A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | __ | 1.31" | 1.15" | 0.314" | -10° to 185° | 00000000 | 00000 |
C14 | 250V AC | 2A (UL), 2A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.17" | 1.94" | 0.314" | -10° to 185° | 0000000 | 00000 |
Snap In | ||||||||||||||
C14 | 250V AC | 2A (UL), 2A (IEC) | 1 | 1 Off (Normally Open) | SPST-NO | __ | __ | __ | 1.3" | 1.16" | 0.039"-0.118" | -10° to 185° | 00000000 | 00000 |
C14 | 250V AC | 2A (UL), 2A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | __ | __ | __ | 1.3" | 1.16" | 0.039"-0.118" | -10° to 185° | 00000000 | 00000 |
C14 | 250V AC | 2A (UL), 2A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.16" | 1.94" | 0.039"-0.118" | -10° to 185° | 0000000 | 00000 |
C14 | 250V AC | 2A (UL), 2A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.88" | 1.13" | 0.039", 0.059", 0.079", 0.098" | -10° to 185° | 0000000 | 00000 |
For Fuse | For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Voltage | Current (Rating) | No. of Circuits Controlled | Switch Starting Position | Industry Designation | For No. of Fuses | O'all Dia., mm | O'all Lg., mm | Ht. | Wd. | For Panel Thick. | Temp. Range, °F | Indicator Color | Each | |
Screw On | |||||||||||||||
C14 | 250V AC | 2A (UL), 2A (IEC) | 2 | 2 Off (Normally Open) | DPST-NO | 2 | 5 | 20 | 1.17" | 1.94" | 0.314" | -10° to 185° | Green | 0000000 | 000000 |
For Fuse | ||||
---|---|---|---|---|
For No. of Fuses | O'all Dia, mm | O'all Lg., mm | Each | |
2 | 5 | 20 | 00000000 | 00000 |