Detector Signal Type Detector Signal Type |
---|
|
Specifications Met Specifications Met |
---|
|
Environment Environment |
---|
|
Environmental Rating Environmental Rating |
---|
Protection Type Protection Type |
---|
|
Battery Chemistry Battery Chemistry |
---|
|
When your work area has too much or too little oxygen, these detectors alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the high and low alarm trigger points to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check can be performed with the press of a button.
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, % Vol. | Volume | Ht. | Wd. | Dp. | Temperature Range, °F | Batteries Included | Battery Chemistry | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0-25 | 95 dB @ 1 ft. | 3 1/2" | 2" | 1" | -4° to 122° | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | ||||||||||
0-25 | 95 dB @ 1 ft. | 3 1/2" | 2" | 1" | -4° to 122° | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 0 Groups IIC, IIB, IIA | 00000000 | 000000 |
Batteries (Pkg. of 1) | 0000000 | Pkg. | 00000 |
Use the probe to test the air in a hazardous area before entering. Great for confined spaces. This detector alerts you with an audible alarm, warning light, and vibrating alarm in the presence of combustible and toxic gases. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Includes | Tube Lg., ft. | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL); Oxygen (0-30% Vol.); Carbon Monoxide (0-1,999 ppm); Hydrogen Sulfide (0-200 ppm) | 95 dB @ 1 ft. | -40° to 140° | Yes | Sampling Probe, Tubing Assembly, Rechargeable Lithium Ion Battery for Probe | 25 | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |
When this detector senses high levels of combustible and toxic gases, it alerts you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL); Oxygen (0-30% Vol.); Carbon Monoxide (0-1,999 ppm); Hydrogen Sulfide (0-200 ppm) | 95 dB @ 1 ft. | -40° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |