Cooling Capacity Cooling Capacity |
|---|
|
Overall Height Overall Height |
|---|
Overall Width Overall Width |
|---|
|
|
|
Current Current |
|---|
Airflow Airflow |
|---|
|
For Opening Width For Opening Width |
|---|
|
|
|
Material Material |
|---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
|---|
For Opening Height For Opening Height |
|---|
|
|
|
Overall Depth Overall Depth |
|---|
|
|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
Electrical Connection Type Electrical Connection Type |
|---|
|
Wattage Wattage |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
About Air Conditioner Cooling Capacity
More
Wall-Mount Enclosure-Cooling Air Conditioners

Protect equipment in enclosures and cabinets from overheating with chilled air. All of these air conditioners are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping. The internal circuits of these air conditioners are rated IP54. The external circuits of these air conditioners are rated IP34.
Air conditioners with 3,600 and 5,100 BTU/hr. cooling capacity require two openings for installation.
Overall | For Opening | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling Cap., Btu/hr. | Airflow, cfm | Current, A | Ht. | Wd. | Dp. | Ht. | Wd. | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | |
With Adjustable Thermostat (68° to 131° F) | ||||||||||||
120V AC, Single Phase, 60Hz—Quick-Disconnect Terminals | ||||||||||||
| 1,000 | 200 | 3.3 | 21 5/8" | 11" | 5 1/2" | 21 5/8" | 11" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 000000000 |
| 2,000 | 160 | 5.7 | 21 5/8" | 11" | 7 7/8" | 21 5/8" | 11" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
| 3,600 | 350 | 10 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
| 5,100 | 470 | 12.5 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
230V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminals | ||||||||||||
| 1,000 | 200 | 1.7 | 21 5/8" | 11" | 5 1/2" | 21 5/8" | 11" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
| 2,000 | 155 | 2.6 | 21 5/8" | 11" | 7 7/8" | 21 5/8" | 11" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
| 3,600 | 350 | 4.4 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
| 5,100 | 470 | 6 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
| 8,000 | 575 | 8.5 | 62 3/16" | 15 3/4" | 11 3/8" | 62 1/8" | 15 3/4" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
460V AC, Three Phase, 50Hz/60Hz—Quick-Disconnect Terminals | ||||||||||||
| 5,100 | 470 | 2.6 | 37 3/8" | 15 3/4" | 10 3/16" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
| 8,000 | 525 | 3 | 62 3/16" | 15 3/4" | 11 3/8" | 62 1/8" | 15 3/4" | Yes | IP34, IP54, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
Ceiling-Mount Enclosure-Cooling Air Conditioners

Protect equipment in enclosures and cabinets from overheating with chilled air. All of these air conditioners are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
Overall | For Opening | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Cooling Cap., Btu/hr. | Airflow, cfm | Current, A | Ht. | Wd. | Dp. | Ht. | Wd. | Mounting Fasteners Included | Each | |
With Adjustable Thermostat (68° to 131° F) | ||||||||||
120V AC, Single Phase, 60Hz—Quick-Disconnect Terminals | ||||||||||
| 3,600 | 285 | 8.7 | 16 5/16" | 23 1/2" | 18 3/4" | 15 3/8" | 19 5/16" | Yes | 00000000 | 000000000 |
| 5,100 | 285 | 14.1 | 16 5/16" | 23 1/2" | 18 3/4" | 15 3/8" | 19 5/16" | Yes | 00000000 | 00000000 |
| 7,200 | 275 | 14.2 | 16 5/16" | 23 1/2" | 18 3/4" | 15 3/8" | 19 5/16" | Yes | 00000000 | 00000000 |
Washdown Enclosure-Cooling Air Conditioners

Suitable for washdown applications, these air conditioners are rated NEMA 4X to resist dirt, washdowns, and corrosion. Use them to protect equipment in enclosures and cabinets from overheating with chilled air. The internal circuits of these air conditioners are rated IP55. The external circuits of these air conditioners are rated IP34.
Overall | For Opening | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling Cap., Btu/hr. | Airflow, cfm | Current, A | Ht. | Wd. | Dp. | Ht. | Wd. | For Use Outdoors | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | |
With Adjustable Thermostat (68° to 131° F) | |||||||||||||
120V AC, Single Phase, 60Hz—Quick-Disconnect Terminals | |||||||||||||
| 1,700 | 160 | 5.7 | 24 3/8" | 11 3/16" | 11 11/16" | 21 5/8" | 11" | Yes | Yes | IP34, IP55, NEMA 4X | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 000000000 |
| 3,600 | 350 | 10 | 40 3/16" | 15 7/8" | 14 1/8" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | Yes | IP34, IP55, NEMA 4X | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
230V AC, Single Phase, 50Hz/60Hz—Quick-Disconnect Terminals | |||||||||||||
| 1,700 | 155 | 2.6 | 24 3/8" | 11 3/16" | 11 11/16" | 21 5/8" | 11" | Yes | Yes | IP34, IP55, NEMA 4X | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
| 3,600 | 350 | 4.4 | 40 3/16" | 15 7/8" | 14 1/8" | 10", 13 3/4" | 13 3/4", 13 3/4" | Yes | Yes | IP34, IP55, NEMA 4X | UL Recognized Component, C-UL Recognized Component, CSA Certified | 00000000 | 00000000 |
Enclosure-Cooling Heat Exchangers





Cool the air in your enclosure to protect electronic components from excessive heat. These heat exchangers absorb heat in the enclosure, then use cooler air outside the enclosure to draw the heat away, lowering the temperature inside. Unlike a fan, they seal out outside air, so dust, moisture, and other contaminants can't get in. Because they use ambient air to cool the enclosure, heat exchangers use less energy and are less likely to cause condensation than air conditioners.
Heat exchangers that meet NEMA 12 and IP54 seal out dust, dirt, and splashing water and oil. Made of steel, these enclosures are powder coated, so they won’t rust in damp environments, but they’re not watertight enough to use outdoors.
NEMA 4- and IP56-rated heat exchangers are designed to withstand rain, snow, and washdowns. They’re made of powder-coated steel.
Heat exchangers rated NEMA 4X and IP56 are made of stainless steel to resist corrosion in the harshest environments. They stand up to weather, washdowns, and corrosive chemicals.
All of these heat exchangers meet American and Canadian safety standards. CE marked heat exchangers also meet European safety standards.
For technical drawings and 3-D models, click on a part number.
Overall | For Opening | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling Capacity, Btu/hr. | Airflow, cfm | Wattage, W | Current, A | Height | Width | Depth | Height | Width | Material | Thermostat Included | For Use Outdoors | Mounting Fasteners Included | Specifications Met | Each | |
NEMA 12, IP54 | |||||||||||||||
120V AC, Single Phase, 60Hz—Screw Terminals | |||||||||||||||
| 4,400 | 180 | 75 | 0.9 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 000000000 |
| 6,800 | 180 | 75 | 0.9 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 10,200 | 560 | 345 | 2.8 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 12,200 | 560 | 345 | 2.8 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
230V AC, Single Phase, 50Hz/60Hz—Screw Terminals | |||||||||||||||
| 4,400 | 180 | 75 | 0.4 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 6,800 | 180 | 75 | 0.4 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 10,200 | 560 | 245 | 1.4 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 12,200 | 560 | 245 | 1.4 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
460V AC, Single Phase, 50Hz/60Hz—Screw Terminals | |||||||||||||||
| 4,400 | 180 | 75 | 0.2 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 6,800 | 180 | 75 | 0.2 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 10,200 | 560 | 245 | 0.7 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 12,200 | 560 | 245 | 0.7 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | No | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
NEMA 4, IP56 | |||||||||||||||
120V AC, Single Phase, 60Hz—Screw Terminals | |||||||||||||||
| 4,400 | 180 | 75 | 0.9 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 6,800 | 180 | 75 | 0.9 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 10,200 | 560 | 345 | 2.8 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 12,200 | 560 | 345 | 2.8 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
230V AC, Single Phase, 50Hz/60Hz—Screw Terminals | |||||||||||||||
| 4,400 | 180 | 75 | 0.4 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 6,800 | 180 | 75 | 0.4 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 10,200 | 560 | 245 | 1.4 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 12,200 | 560 | 245 | 1.4 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
460V AC, Single Phase, 50Hz/60Hz—Screw Terminals | |||||||||||||||
| 4,400 | 180 | 75 | 0.2 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 6,800 | 180 | 75 | 0.2 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 10,200 | 560 | 245 | 0.7 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 12,200 | 560 | 245 | 0.7 | 35" | 12" | 11" | 17" | 10" | Powder-Coated Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
NEMA 4X, IP56 | |||||||||||||||
120V AC, Single Phase, 50Hz/60Hz—Three-Prong Plug | |||||||||||||||
| 1,400 | Not Rated | 80 | 0.7 | 12" | 12" | 8" | 11" | 11" | Stainless Steel | No | Yes | Yes | UL Listed C-UL Listed CE Marked | 0000000 | 00000000 |
| 3,000 | Not Rated | 160 | 1.4 | 23" | 12" | 8" | 21 3/4" | 11" | Stainless Steel | No | Yes | Yes | UL Listed C-UL Listed CE Marked | 0000000 | 00000000 |
120V AC, Single Phase, 60Hz—Screw Terminals | |||||||||||||||
| 4,400 | 180 | 75 | 0.9 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 6,800 | 180 | 75 | 0.9 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 10,200 | 560 | 345 | 2.8 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 12,200 | 560 | 345 | 2.8 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
230V AC, Single Phase, 50Hz/60Hz—Screw Terminals | |||||||||||||||
| 4,400 | 180 | 75 | 0.4 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 6,800 | 180 | 75 | 0.4 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 10,200 | 560 | 245 | 1.4 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 12,200 | 560 | 245 | 1.4 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
460V AC, Single Phase, 50Hz/60Hz—Screw Terminals | |||||||||||||||
| 4,400 | 180 | 75 | 0.2 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 6,800 | 180 | 75 | 0.2 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 10,200 | 560 | 245 | 0.7 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
| 12,200 | 560 | 245 | 0.7 | 35" | 12" | 11" | 17" | 10" | Stainless Steel | Yes | Yes | Yes | UL Listed C-UL Listed | 0000000 | 00000000 |
Thermoelectric Coolers for Enclosures




Also known as Peltier coolers, these coolers use electrical current to transfer heat away from your enclosure while sealing out contaminants. They cool the enclosure to below the ambient temperature. The solid-state thermoelectric components require no maintenance and take up less space than an air conditioner or heat exchanger.
Rated IP66 and NEMA 4X, these coolers withstand weather, washdowns, and corrosive environments. They meet American and European safety standards.
Coolers without a thermostat run continuously when powered. Add a thermostat, timer, or switch to turn them on and off.
An optional extension bracket holds the cooler away from the enclosure wall for more space inside the enclosure.
Add a drain kit to remove moisture when condensation is likely, such as in humid environments and enclosures exposed to rapid temperature changes. The included hose directs water away from electrical components.
For technical drawings and 3-D models, click on a part number.
Coolers | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | For Opening | Extension Brackets | Drain Kits | |||||||||||||
| Cooling Capacity, Btu/hr. | Airflow, cfm | Wattage, W | Current, A | Height | Width | Depth | Height | Width | Environment | Mounting Fasteners Included | Each | Each | Each | |||
Without Thermostat | ||||||||||||||||
12V DC—Terminal Block | ||||||||||||||||
| 100 | 10 | 30 | 2.9 | 4 5/16" | 6 1/8" | 5" | 3 9/16" | 4 13/16" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 0000000 | 0000000 | 000000 | 0000000 | 0000000 |
24V DC—Terminal Block | ||||||||||||||||
| 170 | 10 | 50 | 2.5 | 8 1/8" | 6 1/8" | 5 5/16" | 6 11/16" | 4 3/4" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
| 340 | 25 | 100 | 4.9 | 7 7/8" | 12" | 5 3/8" | 6 5/16" | 10 1/4" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 00000000 | 0000000 | 00000 | 0000000 | 000000 |
| 510 | 35 | 150 | 7.5 | 15 3/4" | 7 1/8" | 6 11/16" | 14 5/8" | 6 1/8" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
| 680 | 70 | 200 | 11.6 | 15 3/4" | 7 1/8" | 6 11/16" | 14 5/8" | 6 1/8" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
48V DC—Terminal Block | ||||||||||||||||
| 850 | 70 | 250 | 9.3 | 15 3/4" | 7 1/8" | 6 11/16" | 14 5/8" | 6 1/8" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
With Adjustable Thermostat (68° to 122° F) | ||||||||||||||||
120-230V AC, Single Phase, 50Hz/60Hz—Terminal Block | ||||||||||||||||
| 340 | 25 | 100 | 1.1 | 11" | 13 13/16" | 6 1/2" | 11" | 13 13/16" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
| 510 | 35 | 150 | 1.5 | 19 11/16" | 13" | 7 11/16" | 13 3/4" | 11 1/4" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
| 680 | 90 | 200 | 2 | 19 11/16" | 13" | 7 11/16" | 18 9/16" | 11 7/8" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
| 1,370 | 140 | 400 | 4 | 23 11/16" | 17" | 8" | 21 5/8" | 15" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
| 2,730 | 280 | 800 | 8 | 38 1/4" | 20 1/4" | 8 5/16" | 36 5/16" | 18 5/16" | Corrosive, Outdoor, Washdown, Wet Location | Yes | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 |
Thermoelectric Modules

Cool down enclosures, laser and optical equipment, and other small devices to maintain their ideal temperature. An electrical current transfers heat from one side of these modules—also known as Peltier modules—to the other. This means the side closest to your equipment stays cold.
Unlike fans and other coolers, these modules don’t have moving parts that require maintenance. They also don’t rely on moving air for cooling, so you can use them in sealed areas, like refrigerators. Compact, they fit in crowded enclosures and other tight spaces. Their flat sides mean you can attach an adhesive-mount heat sink to draw excess heat away from them.
To control these modules, connect their wire leads to a power source and thermostat or switch. You can even alter them for use in heating applications—just reverse the polarity of the DC voltage to switch their hot and cold sides.
Qmax describes the maximum thermal energy these modules can transfer. Delta Tmax refers to the maximum temperature difference between the hot and cold sides. Change the input voltage to adjust this difference in temperature.
For technical drawings and 3-D models, click on a part number.
Maximum Input | Overall | Wire Lead | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Qmax @ Th | Delta Tmax @ Th | Voltage | Current, A | Maximum Temperature, °F | Length | Width | Thickness | Material | Length | Gauge | Each | |
| 3.7 W @ 80° F 4.2 W @ 122° F | 154° F @ 80° F 167° F @ 122° F | 8.8V DC | 0.8 | 175° | 7/16" | 7/16" | 0.12" | Ceramic | 4" | 28 | 0000000 | 000000 |
| 7.1 W @ 80° F 7.9 W @ 122° F | 154° F @ 80° F 167° F @ 122° F | 2.1V DC | 6 | 175° | 5/8" | 5/8" | 0.16" | Ceramic | 4" | 20 | 0000000 | 00000 |
| 13 W @ 80° F 14.5 W @ 122° F | 154° F @ 80° F 167° F @ 122° F | 3.8V DC | 6 | 175° | 13/16" | 13/16" | 0.16" | Ceramic | 4" | 20 | 0000000 | 00000 |
| 42 W @ 80° F 46.9 W @ 122° F | 154° F @ 80° F 167° F @ 122° F | 8.6V DC | 8.5 | 175° | 1 3/16" | 1 3/16" | 0.15" | Ceramic | 4" | 20 | 0000000 | 00000 |
| 75 W @ 80° F 83.9 W @ 122° F | 154° F @ 80° F 167° F @ 122° F | 15.4V DC | 8.5 | 175° | 1 5/8" | 1 5/8" | 0.15" | Ceramic | 4" | 20 | 0000000 | 00000 |
| 200 W @ 80° F 224 W @ 122° F | 154° F @ 80° F 167° F @ 122° F | 24.1V DC | 13 | 175° | 2" | 2" | 0.13" | Ceramic | 4" | 18 | 0000000 | 00000 |