For Use With For Use With |
---|
|
|
Dial Type Dial Type |
---|
![]() | ![]() |
Dry | Liquid Filled |
Case Material Case Material |
---|
|
Connection Material Connection Material |
---|
|
For Panel Cutout Diameter For Panel Cutout Diameter |
---|
|
|
|
Lens Material Lens Material |
---|
|
Accuracy Grade Accuracy Grade |
---|
|
Accuracy Scale Accuracy Scale |
---|
|
More
More
These are the most commonly used pressure gauges. Use them with pumps, filters, regulators, and in process lines to measure and display pressure.
Gauges with 304 stainless steel case or ABS plastic case have better corrosion resistance than gauges with brass or steel case.
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
1/8 Pipe Size | ||
0 to 15 | 0.5 | 1 |
0 to 30 | 0.5 | 5 |
0 to 60 | 1 | 5 |
0 to 100 | 2 | 10 |
0 to 160 | 5 | 20 |
0 to 200 | 5 | 20 |
0 to 300 | 5 | 30 |
0 to 400 | 10 | 50 |
0 to 600 | 10 | 50 |
0 to 1,000 | 20 | 200 |
1/4 Pipe Size | ||
0 to 15 | 0.5 | 1 |
0 to 30 | 0.5 | 5 |
0 to 60 | 1 | 5 |
0 to 100 | 2 | 10 |
0 to 160 | 5 | 20 |
0 to 200 | 5 | 20 |
0 to 300 | 5 | 30 |
0 to 400 | 10 | 50 |
0 to 600 | 10 | 50 |
0 to 1,000 | 20 | 200 |
0 to 2,000 | 50 | 400 |
0 to 3,000 | 100 | 500 |
0 to 4,000 | 100 | 1,000 |
0 to 5,000 | 100 | 1,000 |
0 to 6,000 | 200 | 1,000 |
Center Back Connection (Panel Mount) | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Mounting Orientation | For Panel Cutout Dia. | Each | |
NPT Male | ||||||||
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | Any | 1 31/32" | 0000000 | 000000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Black | Any | 2 7/16" | 0000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | Any | 3 7/64" | 0000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | Any | 4 1/64" | 0000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||||
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | Any | 1 31/32" | 0000000 | 000000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Black | Any | 2 7/16" | 0000000 | 000000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | Any | 3 5/64" | 0000000 | 000000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | Any | 4 1/64" | 0000000 | 000000 |
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
1/8 Pipe Size | ||
0 to 15 | 0.5 | 1 |
0 to 30 | 0.5 | 5 |
0 to 60 | 1 | 5 |
0 to 100 | 2 | 10 |
0 to 160 | 5 | 20 |
0 to 200 | 5 | 20 |
0 to 300 | 5 | 30 |
0 to 400 | 10 | 50 |
0 to 600 | 10 | 50 |
0 to 1,000 | 20 | 200 |
1/4 Pipe Size | ||
0 to 15 | 0.5 | 1 |
0 to 30 | 0.5 | 5 |
0 to 60 | 1 | 5 |
0 to 100 | 2 | 10 |
0 to 160 | 5 | 20 |
0 to 200 | 5 | 20 |
0 to 300 | 5 | 30 |
0 to 400 | 10 | 50 |
0 to 600 | 10 | 50 |
0 to 1,000 | 20 | 200 |
0 to 2,000 | 50 | 400 |
0 to 3,000 | 100 | 500 |
0 to 4,000 | 100 | 1,000 |
0 to 5,000 | 100 | 1,000 |
0 to 6,000 | 200 | 1,000 |
Center Back Connection (Panel Mount) | |||||||
---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Any | 1 3/4" | 000000 | 000000 |
2" | 1/8 | -40° to 150° | -40° to 150° | Any | 2 7/32" | 00000000 | 00000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Any | 2 7/32" | 000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Any | 2 3/4" | 0000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Any | 3 13/16" | 0000000 | 00000 |
Available Pressure Ranges | |||||
---|---|---|---|---|---|
Pressure Range | Graduation Marks | Numeric Increments | |||
psi | kPa | psi | kPa | psi | kPa |
1/8 Pipe Size | |||||
0 to 15 | 0 to 100 | 0.5 | 2 | 1 | 10 |
0 to 30 | 0 to 200 | 0.5 | 5 | 5 | 20 |
0 to 60 | 0 to 400 | 1 | 10 | 5 | 50 |
0 to 100 | 0 to 700 | 2 | 20 | 10 | 100 |
0 to 160 | 0 to 1,100 | 5 | 20 | 20 | 200 |
0 to 200 | 0 to 1,400 | 5 | 20 | 20 | 200 |
0 to 300 | 0 to 2,000 | 5 | 50 | 30 | 200 |
0 to 400 | 0 to 2,800 | 10 | 50 | 50 | 400 |
0 to 600 | 0 to 4,000 | 10 | 100 | 50 | 1,000 |
0 to 1,000 | 0 to 7,000 | 20 | 200 | 200 | 1,000 |
1/4 Pipe Size | |||||
0 to 15 | 0 to 100 | 0.5 | 2 | 1 | 10 |
0 to 30 | 0 to 200 | 0.5 | 5 | 5 | 20 |
0 to 60 | 0 to 400 | 1 | 10 | 5 | 50 |
0 to 100 | 0 to 700 | 2 | 20 | 10 | 100 |
0 to 160 | 0 to 1,100 | 5 | 20 | 20 | 200 |
0 to 200 | 0 to 1,400 | 5 | 20 | 20 | 200 |
0 to 300 | 0 to 2,000 | 5 | 50 | 30 | 200 |
0 to 400 | 0 to 2,800 | 10 | 50 | 50 | 400 |
0 to 600 | 0 to 4,000 | 10 | 100 | 50 | 1,000 |
0 to 1,000 | 0 to 7,000 | 20 | 200 | 200 | 1,000 |
0 to 2,000 | 0 to 14,000 | 50 | 200 | 400 | 2,000 |
0 to 3,000 | 0 to 20,000 | 100 | 1,000 | 500 | 5,000 |
0 to 4,000 | 0 to 28,000 | 100 | 1,000 | 1,000 | 5,000 |
0 to 5,000 | 0 to 35,000 | 100 | 1,000 | 1,000 | 5,000 |
0 to 6,000 | 0 to 40,000 | 200 | 2,000 | 1,000 | 10,000 |
Center Back Connection (Panel Mount) | |||||||
---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Any | 1 3/4" | 00000000 | 000000 |
2" | 1/8 | -40° to 150° | -40° to 150° | Any | 2 7/32" | 00000000 | 00000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Any | 2 7/32" | 00000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Any | 2 3/4" | 00000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Any | 3 13/16" | 00000000 | 00000 |
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 15 | 0.5 | 3 |
0 to 30 | 0.5 | 5 |
0 to 60 | 1 | 10 |
0 to 100 | 2 | 20 |
0 to 160 | 2 | 20 |
0 to 200 | 5 | 40 |
0 to 300 | 5 | 50 |
0 to 400 | 10 | 50 |
0 to 600 | 10 | 100 |
0 to 1,000 | 10 | 200 |
0 to 1,500 | 20 | 200 |
0 to 2,000 | 20 | 400 |
0 to 3,000 | 50 | 500 |
0 to 4,000 | 100 | 1,000 |
0 to 5,000 | 100 | 1,000 |
0 to 6,000 | 100 | 1,000 |
Center Back Connection (Panel Mount) | ||||||||
---|---|---|---|---|---|---|---|---|
For Pressure Ranges, psi | Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | For Panel Cutout Dia. | Each | |
NPT Male | ||||||||
0-15 to 0-6,000 | 2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Any | 2 35/64" | 0000000 | 000000 |
0-15 to 0-6,000 | 4" | 1/4 | -40° to 150° | -40° to 150° | Any | 3 31/32" | 0000000 | 00000 |
These gauges fit into square cutouts in your instrument panel. Use them with pumps, filters, regulators, and in process lines to measure and display pressure.
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 15 | 0.5 | 1 |
0 to 30 | 1 | 5 |
0 to 60 | 2 | 10 |
0 to 100 | 1 | 10 |
0 to 160 | 5 | 20 |
0 to 200 | 2 | 20 |
0 to 300 | 10 | 50 |
Center Back Connection (Panel Mount) | ||||||||
---|---|---|---|---|---|---|---|---|
Dial | For Panel Cutout | |||||||
Ht. | Wd. | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Ht. | Wd. | Each | |
1/8 NPT Male/10-32 UNF Female | ||||||||
2" | 2" | 0° to 140° | 0° to 140° | Black | 1 49/64" | 1 49/64" | 0000000 | 000000 |
A liquid-filled dial reduces needle flutter for precise readings in high-vibration applications. Gauges are commonly used with pumps, filters, regulators, and in process lines to measure and display pressure. Mount them with the dial face upright.
Silicone-filled dials withstand lower temperatures than glycerin-filled dials and provide greater resistance to sudden shocks such as water hammer.
Gauges with 304 stainless steel case and ABS plastic case have better corrosion resistance than gauges with brass case.
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | |||||
---|---|---|---|---|---|
Pressure Range | Graduation Marks | Numeric Increments | |||
psi | kPa | psi | kPa | psi | kPa |
0 to 30 | 0 to 205 | 0.5 | 5 | 5 | 50 |
0 to 60 | 0 to 410 | 1 | 10 | 10 | 100 |
0 to 100 | 0 to 680 | 2 | 20 | 20 | 200 |
0 to 160 | 0 to 1,100 | 4 | 40 | 40 | 400 |
0 to 200 | 0 to 1,360 | 4 | 40 | 40 | 400 |
0 to 300 | 0 to 2,050 | 5 | 50 | 50 | 500 |
0 to 400 | 0 to 2,700 | 10 | 100 | 100 | 1,000 |
0 to 600 | 0 to 4,100 | 10 | 100 | 100 | 1,000 |
0 to 1,000 | 0 to 6,800 | 20 | 200 | 200 | 2,000 |
0 to 1,500 | 0 to 10,200 | 20 | 200 | 300 | 3,000 |
0 to 2,000 | 0 to 13,600 | 40 | 400 | 400 | 4,000 |
0 to 3,000 | 0 to 20,500 | 50 | 500 | 500 | 5,000 |
0 to 5,000 | 0 to 34,000 | 100 | 1,000 | 1,000 | 10,000 |
0 to 6,000 | 0 to 41,000 | 100 | 1,000 | 1,000 | 10,000 |
Center Back Connection (Panel Mount) | |||||||||
---|---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Liquid Type | Mounting Orientation | For Panel Cutout Dia. | Each | |
NPT Male | |||||||||
2 1/2" | 1/4 | 0° to 140° | 0° to 140° | Black | Glycerin | Upright | 2 1/2" | 000000 | 000000 |
Available Pressure Ranges | |||||
---|---|---|---|---|---|
Pressure Range | Graduation Marks | Numeric Increments | |||
psi | kPa | psi | kPa | psi | kPa |
0 to 15 | 0 to 100 | 0.5 | 2 | 3 | 20 |
0 to 30 | 0 to 200 | 0.5 | 5 | 5 | 50 |
0 to 60 | 0 to 400 | 1 | 10 | 10 | 100 |
0 to 100 | 0 to 700 | 2 | 20 | 20 | 100 |
0 to 160 | 0 to 1,100 | 5 | 20 | 20 | 200 |
0 to 200 | 0 to 1,400 | 5 | 50 | 50 | 200 |
0 to 300 | 0 to 2,000 | 10 | 40 | 50 | 400 |
0 to 600 | 0 to 4,000 | 10 | 100 | 100 | 1,000 |
0 to 1,000 | 0 to 7,000 | 20 | 200 | 200 | 1,000 |
0 to 1,500 | 0 to 10,000 | 50 | 200 | 300 | 2,000 |
0 to 2,000 | 0 to 14,000 | 40 | 500 | 400 | 2,000 |
0 to 3,000 | 0 to 20,000 | 50 | 400 | 500 | 4,000 |
0 to 5,000 | 0 to 35,000 | 100 | 1,000 | 1,000 | 5,000 |
Center Back Connection (Panel Mount) | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Mounting Orientation | For Panel Cutout Dia. | Each | |
NPT Male | ||||||||
1 1/2" | 1/8 | -20° to 160° | -20° to 160° | Silicone | Upright | 1 5/8" | 0000000 | 000000 |
These gauges have a red needle that indicates the highest pressure reached since the last setting. They have a glycerin-filled dial that reduces needle flutter for precise readings in high-vibration applications. Use them with pumps, filters, regulators, and in process lines to measure and display pressure. Mount gauges with the dial face upright.
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 15 | 0.2 | 3 |
0 to 30 | 0.5 | 5 |
0 to 60 | 1 | 10 |
0 to 100 | 2 | 20 |
0 to 160 | 4 | 40 |
0 to 200 | 4 | 40 |
0 to 300 | 5 | 50 |
0 to 400 | 10 | 100 |
0 to 600 | 10 | 100 |
0 to 1,000 | 20 | 200 |
0 to 1,500 | 20 | 300 |
0 to 3,000 | 50 | 500 |
0 to 5,000 | 100 | 1,000 |
0 to 7,500 | 100 | 1,500 |
0 to 10,000 | 200 | 2,000 |
0 to 15,000 | 200 | 3,000 |
Center Back Connection (Panel Mount) | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | Mounting Orientation | For Panel Cutout Dia. | Each | |
NPT Male | ||||||||
2 1/2" | 1/4 | 0° to 140° | 0° to 140° | Glycerin | Upright | 2 1/2" | 0000000 | 0000000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||||
2 1/2" | 1/4 | 0° to 140° | 0° to 140° | Glycerin | Upright | 2 1/2" | 0000000 | 000000 |
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | ||||||
---|---|---|---|---|---|---|
1 1/2" Dial Diameter | 2 1/2" Dial Diameter | 4" Dial Diameter | ||||
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi | Graduation Marks, psi | Numeric Increments, psi | Graduation Marks, psi | Numeric Increments, psi |
Gauges | ||||||
0 to 15 | 0.5 | 3 | 0.5 | 3 | 0.5 | 3 |
0 to 30 | 0.5 | 5 | 0.5 | 5 | 0.5 | 5 |
0 to 60 | 1 | 10 | 1 | 10 | 1 | 10 |
0 to 100 | 2 | 20 | 2 | 20 | 2 | 20 |
0 to 160 | 2 | 20 | 2 | 20 | 2 | 20 |
0 to 200 | 5 | 40 | 5 | 40 | 5 | 40 |
0 to 300 | 5 | 50 | 5 | 50 | 5 | 50 |
0 to 400 | 5 | 50 | 10 | 50 | 10 | 50 |
0 to 600 | 10 | 100 | 10 | 100 | 10 | 100 |
0 to 1,000 | 20 | 200 | 20 | 200 | 20 | 200 |
0 to 2,000 | 50 | 400 | 50 | 400 | 50 | 400 |
0 to 3,000 | 50 | 500 | 50 | 500 | 50 | 500 |
0 to 4,000 | 50 | 500 | 50 | 500 | 50 | 500 |
0 to 5,000 | 100 | 1,000 | 100 | 1,000 | 100 | 1,000 |
Center Back Connection (Panel Mount) | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | Liquid Type | For Panel Cutout Dia. | Each | |
NPT Male | ||||||||
1 1/2" | 1/8 | 20° to 150° | 20° to 200° | Any | Glycerin | 1 11/16" | 0000000 | 0000000 |
2 1/2" | 1/4 | 20° to 150° | 20° to 200° | Any | Glycerin | 2 9/16" | 0000000 | 00000 |
4" | 1/4 | 20° to 150° | 20° to 200° | Any | Glycerin | 3 31/32" | 0000000 | 000000 |
Both the case material and connection threads are stainless steel, giving these gauges excellent corrosion resistance in harsh environments. Use them with pumps, filters, regulators, and in process lines to measure and display pressure.
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 15 | 0.5 | 3 |
0 to 30 | 0.5 | 5 |
0 to 60 | 1 | 10 |
0 to 100 | 2 | 20 |
0 to 160 | 2 | 20 |
0 to 200 | 5 | 40 |
0 to 300 | 5 | 50 |
0 to 400 | 5 | 50 |
0 to 400 | 10 | 50 |
0 to 600 | 10 | 100 |
0 to 1,000 | 20 | 200 |
0 to 2,000 | 50 | 400 |
0 to 3,000 | 50 | 500 |
0 to 4,000 | 50 | 500 |
0 to 5,000 | 100 | 1,000 |
Center Back Connection (Panel Mount) | |||||||
---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
1 1/2" | 1/8 | 0° to 200° | 0° to 200° | Any | 1 11/16" | 0000000 | 000000 |
2 1/2" | 1/4 | 0° to 200° | 0° to 200° | Any | 2 9/16" | 0000000 | 00000 |
4" | 1/4 | 0° to 200° | 0° to 200° | Any | 3 31/32" | 0000000 | 000000 |
Not only do these gauges withstand corrosive environments, they have the precision needed for critical processes that require high accuracy, such as hydraulic and laboratory applications. Use them with pumps, filters, regulators, and in process lines to measure and display pressure. Mount gauges with the dial face upright.
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | ||
---|---|---|
2 1/2" Dial Diameter | ||
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 15 | 0.2 | 3 |
0 to 30 | 0.5 | 5 |
0 to 60 | 1 | 10 |
0 to 100 | 2 | 20 |
0 to 160 | 4 | 40 |
0 to 200 | 4 | 40 |
0 to 300 | 5 | 50 |
0 to 400 | 10 | 100 |
0 to 600 | 10 | 100 |
0 to 1,000 | 20 | 200 |
0 to 1,500 | 20 | 300 |
0 to 2,000 | 40 | 400 |
0 to 3,000 | 50 | 500 |
0 to 5,000 | 100 | 1,000 |
0 to 6,000 | 100 | 1,000 |
0 to 10,000 | 200 | 2,000 |
Center Back Connection (Panel Mount) | |||||||
---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
2 1/2" | 1/4 | -40° to 140° | -40° to 210° | Upright | 2 1/2" | 00000000 | 0000000 |
Designed for harsh environments prone to vibration, these gauges pair a corrosion-resistant 304 stainless steel case with a glycerin-filled dial that reduces needle flutter. Also known as compound gauges, they measure both pressure and vacuum. Use them with pumps, filters, regulators, compressors, and in suction and process lines.
For technical drawings and 3-D models, click on a part number.
Available Pressure Ranges | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pressure Range | Vacuum Range | Graduation Marks | Numeric Increments | ||||||
psi | kPa | in. of Hg | kPa | psi | in. of Hg | kPa | psi | in. of Hg | kPa |
1 1/2" Dial Diameter | |||||||||
0 to 15 | 0 to 100 | 30 to 0 | -100 to 0 | 1 | 1 | 5 | 5 | 10 | 50 |
0 to 30 | 0 to 200 | 30 to 0 | -100 to 0 | 1 | 1 | 5 | 10 | 10 | 50 |
0 to 60 | 0 to 400 | 30 to 0 | -100 to 0 | 1 | 2 | 10 | 10 | 10 | 100 |
0 to 100 | 0 to 700 | 30 to 0 | -100 to 0 | 2 | 5 | 20 | 20 | 30 | 100 |
0 to 150 | 0 to 1,000 | 30 to 0 | -100 to 0 | 2 | 5 | 20 | 20 | 30 | 200 |
2 1/2" Dial Diameter | |||||||||
0 to 15 | 0 to 100 | 30 to 0 | -100 to 0 | 0.5 | 1 | 5 | 5 | 10 | 50 |
0 to 30 | 0 to 200 | 30 to 0 | -100 to 0 | 1 | 2 | 5 | 10 | 10 | 50 |
0 to 60 | 0 to 400 | 30 to 0 | -100 to 0 | 2 | 2 | 10 | 20 | 30 | 100 |
0 to 100 | 0 to 680 | 30 to 0 | -100 to 0 | 2 | 5 | 10 | 20 | 30 | 200 |
0 to 160 | 0 to 1,100 | 30 to 0 | -100 to 0 | 5 | 10 | 20 | 40 | 30 | 200 |
0 to 200 | 0 to 1,350 | 30 to 0 | -100 to 0 | 5 | 10 | 50 | 50 | 30 | 200 |
0 to 300 | 0 to 2,050 | 30 to 0 | -100 to 0 | 5 | 10 | 50 | 50 | 30 | 500 |
Available Pressure and Vacuum Ranges | |||||
---|---|---|---|---|---|
Graduation Marks | Numeric Increments | ||||
Pressure Range, psi | Vacuum Range, in. of Hg | psi | in. of Hg | psi | in. of Hg |
0 to 15 | 30 to 0 | 0.5 | 1 | 5 | 10 |
0 to 30 | 30 to 0 | 1 | 2 | 10 | 30 |
0 to 60 | 30 to 0 | 2 | 5 | 20 | 30 |
0 to 100 | 30 to 0 | 2 | 5 | 20 | 30 |
0 to 160 | 30 to 0 | 4 | 10 | 40 | 30 |
0 to 300 | 30 to 0 | 5 | 10 | 50 | 30 |
Center Back Connection (Panel Mount) | |||||||
---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
2 1/2" | 1/4 | -40° to 140° | -40° to 210° | Glycerin | 2 7/16" | 0000000 | 0000000 |
Also known as compound gauges, these measure both pressure and vacuum. Use them with pumps, filters, regulators, compressors, and in suction and process lines.
Gauges with steel case are more impact resistant than gauges with ABS plastic case.
For technical drawings and 3-D models, click on a part number.
Available Pressure and Vacuum Ranges | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pressure Range | Vacuum Range | Graduation Marks | Numeric Increments | ||||||
psi | kPa | in. of Hg | kPa | psi | kPa | in. of Hg | psi | kPa | in. of Hg |
0 to 15 | 0 to 100 | 30 to 0 | -100 to 0 | 0.5 | 5 | 1 | 5 | 20 | 5 |
0 to 30 | 0 to 200 | 30 to 0 | -100 to 0 | 1 | 5 | 1 | 5 | 50 | 5 |
0 to 75 | 0 to 500 | 30 to 0 | -100 to 0 | 5 | 20 | 2 | 10 | 100 | 10 |
0 to 100 | 0 to 700 | 30 to 0 | -100 to 0 | 2 | 20 | 5 | 10 | 100 | 15 |
0 to 160 | 0 to 1,100 | 30 to 0 | -100 to 0 | 2 | 20 | 5 | 20 | 200 | 30 |
0 to 200 | 0 to 1,400 | 30 to 0 | -100 to 0 | 2 | 50 | 5 | 20 | 200 | 30 |
0 to 300 | 0 to 2,100 | 30 to 0 | -100 to 0 | 10 | 50 | 15 | 50 | 300 | 30 |
A 304 stainless steel case coupled with 316 stainless steel connection threads provide protection from corrosive environments. Also known as compound gauges, these measure both pressure and vacuum. Use them with pumps, filters, regulators, compressors, and in suction and process lines.
For technical drawings and 3-D models, click on a part number.
Available Pressure and Vacuum Ranges | |||||
---|---|---|---|---|---|
Nylon Plastic Lens | |||||
Graduation Marks | Numeric Increments | ||||
Pressure Range, psi | Vacuum Range, in. of Hg | psi | in. of Hg | psi | in. of Hg |
0 to 15 | 30 to 0 | 0.5 | 1 | 5 | 10 |
0 to 30 | 30 to 0 | 1 | 2 | 10 | 30 |
0 to 60 | 30 to 0 | 2 | 5 | 20 | 30 |
0 to 100 | 30 to 0 | 2 | 5 | 20 | 30 |
0 to 160 | 30 to 0 | 4 | 10 | 40 | 30 |
0 to 300 | 30 to 0 | 5 | 10 | 50 | 30 |
Center Back Connection (Panel Mount) | |||||||
---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Lens Material | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
2 1/2" | 1/4 | -40° to 140° | -40° to 210° | Nylon Plastic | 2 7/16" | 0000000 | 000000 |
Use these gauges with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
Gauges with ABS plastic case are more corrosion resistant than gauges with steel case. Gauges with steel case are more impact resistant than gauges with ABS plastic case.
For technical drawings and 3-D models, click on a part number.
Available Vacuum Ranges | ||
---|---|---|
Vacuum Range, in. of Hg | Graduation Marks, in. of Hg | Numeric Increments, in. of Hg |
30 to 0 | 0.5 | 5 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 |
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
---|---|---|---|---|---|---|---|
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 1 3/4" | 0000000 | 000000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Black | 2 7/32" | 00000000 | 00000 |
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 2 3/4" | 00000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 2 3/4" | 00000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 3 13/16" | 00000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | |||||||
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 1 3/4" | 00000000 | 00000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Black | 2 7/32" | 00000000 | 00000 |
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 2 3/4" | 00000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 2 3/4" | 00000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 3 13/16" | 00000000 | 000000 |
Available Vacuum Ranges | |||||
---|---|---|---|---|---|
Vacuum Range | Graduation Marks | Numeric Increments | |||
in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa |
30 to 0 | -100 to 0 | 0.5 | 2 | 5 | 10 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 00000000 | 000000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||
2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 00000000 | 00000 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
---|---|---|---|---|---|---|---|
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 1 3/4" | 00000000 | 000000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Black | 2 7/32" | 0000000 | 00000 |
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 2 3/4" | 00000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 2 3/4" | 0000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 3 13/16" | 0000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | |||||||
1 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 1 3/4" | 00000000 | 00000 |
2" | 1/4 | -40° to 150° | -40° to 150° | Black | 2 7/32" | 00000000 | 00000 |
2 1/2" | 1/8 | -40° to 150° | -40° to 150° | Black | 2 3/4" | 00000000 | 00000 |
2 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 2 3/4" | 00000000 | 00000 |
3 1/2" | 1/4 | -40° to 150° | -40° to 150° | Black | 3 13/16" | 00000000 | 000000 |
Available Vacuum Ranges | ||
---|---|---|
Vacuum Range, in. of Hg | Graduation Marks, in. of Hg | Numeric Increments, in. of Hg |
30 to 0 | 0.5 | 5 |
Center Back Connection | ||||||
---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Each | |
NPT Male | ||||||
2 1/2" | 1/8 | -40° to 140° | -40° to 140° | Black | 0000000 | 000000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||
1 1/2" | 1/8 | -40° to 140° | -40° to 140° | Black | 0000000 | 000000 |
2" | 1/8 | -40° to 140° | -40° to 140° | Black | 0000000 | 000000 |
2 1/2" | 1/4 | -40° to 140° | -40° to 140° | Black | 0000000 | 000000 |
Available Vacuum Ranges | |||||
---|---|---|---|---|---|
Vacuum Range | Graduation Marks | Numeric Increments | |||
in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa |
30 to 0 | -100 to 0 | 0.5 | 2 | 5 | 10 |
Center Back Connection | ||||||
---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Each | |
NPT Male | ||||||
1 1/2" | 1/8 | -40° to 140° | -40° to 140° | Black | 0000000 | 000000 |
2" | 1/8 | -40° to 140° | -40° to 140° | Black | 0000000 | 00000 |
2 1/2" | 1/4 | -40° to 140° | -40° to 140° | Black | 0000000 | 00000 |
NPT Male with Calibration Certificate Traceable to NIST | ||||||
1 1/2" | 1/8 | -40° to 140° | -40° to 140° | Black | 0000000 | 000000 |
2" | 1/8 | -40° to 140° | -40° to 140° | Black | 0000000 | 000000 |
2 1/2" | 1/4 | -40° to 140° | -40° to 140° | Black | 0000000 | 000000 |
Designed for harsh environments prone to vibration, these gauges pair a corrosion-resistant 304 stainless steel case with a glycerin-filled dial to reduce needle flutter. Use them with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
For technical drawings and 3-D models, click on a part number.
Available Vacuum Ranges | ||
---|---|---|
Vacuum Range, in. of Hg | Graduation Marks, in. of Hg | Numeric Increments, in. of Hg |
30 to 0 | 0.5 | 5 |
Center Back Connection (Panel Mount) | |||||||
---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Liquid Type | For Panel Cutout Dia. | Each | |
NPT Male | |||||||
2 1/2" | 1/4 | -40° to 140° | -40° to 210° | Glycerin | 2 7/16" | 000000000 | 0000000 |
Available Vacuum Ranges | |||||
---|---|---|---|---|---|
Gauges | |||||
Vacuum Range | Graduation Marks | Numeric Increments | |||
in. of Hg | kPa | in. of Hg | kPa | in. of Hg | kPa |
1 1/2" Dial Diameter | |||||
30 to 0 | -100 to 0 | 0.5 | 2 | 5 | 20 |
2 1/2" Dial Diameter | |||||
30 to 0 | -100 to 0 | 0.5 | 2 | 5 | 10 |
The case and connection threads are stainless steel for protection in corrosive environments. Use these gauges with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
For technical drawings and 3-D models, click on a part number.
Available Vacuum Ranges | ||
---|---|---|
Vacuum Range, in. of Hg | Graduation Marks, in. of Hg | Numeric Increments, in. of Hg |
2 1/2" Dial Diameter | ||
30 to 0 | 0.5 | 5 |
Center Back Connection (Panel Mount) | ||||||
---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | For Panel Cutout Dia. | Each | |
NPT Male | ||||||
2 1/2" | 1/4 | -40° to 140° | -40° to 210° | 2 7/16" | 000000000 | 000000 |