Mount Type Mount Type | Show |
|---|
|
Mount Type Mount Type | Hide |
|---|
Thermometer Type Thermometer Type |
|---|
| Direct Reading | Remote Reading |
Maximum Temperature Maximum Temperature |
|---|
Minimum Temperature Minimum Temperature |
|---|
Scale Scale |
|---|
|
System of Measurement System of Measurement |
|---|
|
Probe Material Probe Material |
|---|
|
Housing Material Housing Material |
|---|
|
Maximum Cable Temperature Maximum Cable Temperature |
|---|
|
|
|
Maximum Pressure Maximum Pressure |
|---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
|---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
Cable Material Cable Material |
|---|
|
Fasteners Included Fasteners Included |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
About Selecting Temperature Sensors
More
Miniature Remote-Reading Panel-Mount Thermometers


Install the small display in tight spaces and crowded instrument panels up to 10 feet from the probe.
Probe | Mtg. Holes | For Panel Cutout | Material | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temperature Range | Resolution | Accuracy | Lg. | Dia. | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | Dp. | Housing | Probe | Batteries Included | Each | |
| -40° to 300° F/ -40° to 150° C | 0.1/0.1 | ±1.8° F | 7/8" | 3/16" | 2 | 5/32" | No | 1 1/2" | 2 3/4" | 1 5/8" | 2 15/16" | 1" | Plastic | Stainless Steel | Yes | 0000000 | 000000 |
| 14° to 230° F/ -10° to 110° C | 0.1/0.1 | ±1° F | 20" | 3/16" | 2 | 3/8" | No | 3 3/4" | 4 3/4" | 3 5/16" | 4 3/4" | 1 1/4" | Plastic | Stainless Steel | Yes | 0000000 | 000000 |
Remote-Reading Panel-Mount Thermometers





Monitor the temperature of difficult-to-access system components from a distance. The probe is connected to a cable, so the dial can be mounted away from your system. Mount the dial no more than 5 feet above or below the probe to ensure accuracy.
Bracket-mount thermometers have an adjustable bracket that allows the dial to pivot 90° front to back.
For technical drawings and 3-D models, click on a part number.
Available Temperature Ranges | ||
|---|---|---|
| Temperature Range | Graduation Marks | Accuracy |
| 40° to 240° F | 2° F | ±1% |
| 100° to 350° F | 2° F | ±1% |
| -40° to 110° F/-40° to 43° C | 1° F/1° C | ±1% |
| -20° to 100° F/-30° to 35° C | 2° F/1° C | ±1% |
| 0° to 150° F/-15° to 65° C | 2° F/1° C | ±1% |
| 0° to 180° F/-20° to 80° C | 1° F/1° C | ±1% |
| 30° to 300° F/0° to 150° C | 2° F/1° C | ±1% |
Probe | Mtg. Holes | Material | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Pipe Size | Thread Type | Gender | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | For Panel Cutout Dia. | Max. Pressure | Housing | Probe | Each | |
Front Flange Mount | |||||||||||||||||
| 3 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 3 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 3 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 3 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 4 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 4 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 4 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 4 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
Back Flange Mount | |||||||||||||||||
| 3 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 00000 |
| 3 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 3 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 3 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 4 3/4" | 4 5/16" | 3 | 5/32" | No | 3 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 4 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 4 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 4 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
| 4 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | 110 psi @ 72° F | Stainless Steel | Copper | 0000000 | 000000 |
Bracket Mount | |||||||||||||||||
| 3 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 00000 |
| 3 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
| 3 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
| 3 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
| 4 1/2" | 5 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
| 4 1/2" | 10 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
| 4 1/2" | 15 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
| 4 1/2" | 20 | 3 3/8" | 7/16" | 1/2 | NPT | Male | __ | __ | 2 | 1/4" | No | __ | 110 psi @ 72° F | Stainless Steel | Copper | 00000000 | 000000 |
| Optional Brass Thermowell | 000000 | Each | 000000 |
Remote-Reading Panel-Mount Freezer Thermometers with Audible Alarm

Protect temperature-sensitive materials in refrigerators and freezers with one of these thermometers that sound an alarm and flash the display when temperature rises above your activation point. Alarm requires a power supply (sold separately).
Probe | Mtg. Holes | For Panel Cutout | Input Voltage | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temperature Range | Actuation Point Temperature Range | Resolution | Accuracy | Cable Lg., ft. | Dia. | Lg. | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | AC | DC | Electrical Connection | Frequency, Hz | Each | |
| -25° F to 99° F/-32° C to 38° C | -15° F to 50° F/-26° C to 10° C | 1/1 | ±3° F | 6 | 3/8" | 7/8" | 2 | 7/32" | No | 3 7/8" | 2 7/8" | 5" | 3 1/8" | 10.5 to 28 | 12 to 28 | Wire Leads | 60 | 000000 | 0000000 |
| 12V AC Output/120V AC Input Power Supply | 0000000 | Each | 000000 |
High-Temperature Panel-Mount Thermometers

Often used to remotely monitor probe readings in high-temperature applications, these thermometers have a housing designed for installation in instrument and control panels. They interpret data from a thermocouple probe or RTD probe (sold separately).
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temperature Range | Resolution | Accuracy | For Thermocouple Probe Type | For RTD Probe Type | DIN Trade Size | Ht. | Wd. | Ht. | Wd. | Dp. | Electrical Connection | Frequency, Hz | Each | |
| -2° to 752° F | 1 | ±3.3° F | K | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 0000000 |
| 0° to 1,000° F | 1 | ±5.0° F | J | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
| 0° to 1,999° F | 1 | ±10.0° F | K | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
| 32° to 428° F | 1 | ±2.8° F | J | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
| -346° to 1,400° F/-210° to 760° C | 1 | ±3.7° F | J | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
| -157° to 752° F/-105° to 400° C | 1 | ±3.7° F | T | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
| -157° to 1,999° F/-105° to 1,372° C | 1 | ±3.7° F | K | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
| -58° to 200° F/-50° to 199° C | 0.1 | ±0.3° F | __ | 100 ohms | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
| -58° to 1,562° F/-50° to 850° C | 1 | ±2.0° F | __ | 100 ohms | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
Food and Beverage Panel-Mount Thermometers




For use in food processing and preparation areas, these thermometers meet NSF/ANSI standards. They have an unthreaded probe attached to a cable for dropping into tanks, vats, and drums.
For technical drawings and 3-D models, click on a part number.
Available Temperature Ranges | ||
|---|---|---|
| Temperature Range | Graduation Marks | Accuracy |
| -40° to 60° F/-40° to 15° C | 2° F/1° C | ±1% |
| -40° to 110° F/-40° to 43° C | 2° F/1° C | ±1% |
| 40° to 240° F/0° to 115° C | 2° F/1° C | ±1% |
Probe | Mtg. Holes | Material | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | Panel Cutout Dia. | Housing | Probe | Specifications Met | Each | |
| *Only available in -40° to 110° F/-40° to 43° C | ||||||||||||||
Front Flange Mount | ||||||||||||||
| 2" | 4 | 2 1/2" | 3/8" | 2 15/16" | 2 9/16" | 3 | 9/64" | No | 2 1/16" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 000000 |
| 2 1/2" | 4 | 2 1/2" | 3/8" | 3 11/16" | 3 5/16" | 3 | 11/64" | No | 2 5/8" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 |
| 4 1/2" | 4 | 3 1/2" | 3/8" | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 000000 |
Back Flange Mount | ||||||||||||||
| 2" | 4 | 2 1/2" | 3/8" | 2 15/16" | 2 9/16" | 3 | 9/64" | No | 2 1/16" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 00000 |
| 2 1/2" | 4 | 2 1/2" | 3/8" | 3 11/16" | 3 5/16" | 3 | 11/64" | No | 2 5/8" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 000000000 | 00000 |
| 4 1/2" | 4 | 3 1/2" | 3/8" | 5 7/8" | 5 3/8" | 3 | 7/32" | No | 4 5/8" | Stainless Steel | Nickel-Plated Copper | NSF/ANSI 2 | 00000000 | 000000 |
Quick-Response Food and Beverage Panel-Mount Thermometers

A resistance temperature detector (RTD) probe responds to temperature change faster than dial thermometers.
For technical drawings and 3-D models, click on a part number.
Probe | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temperature Range | Resolution | Accuracy | For RTD Probe Type | Cable Lg., ft. | Dia. | Lg. | Panel Cutout Dia. | AC Voltage | Electrical Connection | Response Time, sec. | Includes | Each | |
| -40° to 250° F | 1 | ±2° F | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 0000000 |
| -40° to 120° C | 1 | ±2° C | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 000000 |
Panel-Mount Thermometers

For mounting on instrument and control panels, these thermometers have a back flange.
Stem | Mtg. Holes | Material | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temperature Range | Graduation Marks , °F | Accuracy | Lg. | Dia. | Dial Dia. | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | Housing | Stem | Each | |
Back Flange Mount | ||||||||||||||
| -40° to 160° F -40° to 70° C | 2° | ±3° F | 6" | 1/4" | 2" | 3 1/2" | 2 7/8" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 000000 |
| -40° to 160° F | 2° | ±4° F | 9" | 1/4" | 2 1/2" | 3 5/16" | 3" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 00000 |
| 0° to 200° F | 2° | ±4° F | 6" | 1/4" | 2 1/2" | 3 5/16" | 3" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 00000 |
| 0° to 200° F | 2° | ±4° F | 9" | 1/4" | 2 1/2" | 3 5/16" | 3" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 00000 |
| 0° to 220° F -15° to 100° C | 2° | ±2° F | 4" | 1/4" | 2" | 3 1/2" | 2 7/8" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 00000 |
High-Accuracy Panel-Mount Thermometers with Calibration Certificate


Obtain the most accurate readings possible with these thermometers that include a calibration certificate traceable to NIST that states they’ve passed a test to fall within ±0.5° F accuracy. The thermometer probe is connected to a cable, so the display can be mounted away from your system for remote viewing.
For technical drawings and 3-D models, click on a part number.
Probe | Mtg. Holes | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cable Lg., ft. | Temperature Range, ° F | Resolution | Accuracy | Dial Dia. | Lg. | Dia. | Pipe Size | Thread Type | Gender | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | Probe Material | Batteries Included | Each | |
Back Flange Mount | ||||||||||||||||||
| 5 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 0000000 |
| 10 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 000000 |
| 15 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 000000 |
| 20 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 000000 |
| 25 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 000000 |
Heavy Duty Panel-Mount Thermometers with Thermowell


The included thermowell protects the probe from the effects of vibration, shock, pressure, and corrosive liquids in tanks and pipelines. The probe is connected to a cable, so the dial can be mounted away from your system or in a control panel.
Available Temperature Ranges | ||
|---|---|---|
| Temperature Range | Graduation Marks | Accuracy |
| 0° to 300° F | 5° F | ±1% |
Probe | Mtg. Holes | Material | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Pipe Size | Thread Type | Gender | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | Housing | Probe | Each | |
Back Flange Mount | |||||||||||||||
| 4 1/2" | 10 | 2 1/2" | 5/8" | 3/4 | NPT | Male | 5 13/16" | 5 3/8" | 3 | 7/32" | No | Aluminum | Stainless Steel | 00000000 | 0000000 |
Noncontact Infrared Thermocouple Probes for Surfaces

Monitor the temperature of hazardous, sensitive, and hard-to-reach surfaces without touching them. Enclosure meets NEMA 4 for use in washdown environments and IP65 for protection from dust and splashing water.
Use a power adapter (not included) to convert AC voltage to DC voltage. Use the included nuts to install these probes through a mounting bracket (not included) for continuous, hands-free temperature monitoring.
Probe | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temperature Range, ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | For Panel Cutout Dia. | Cable Material | Max. Cable Temperature, ° F | Max. Working Distance, ft. | DC Voltage | Environmental Rating | Each | |
Type J | ||||||||||||||
| 32° to 660° | 3 1/2" | 3/4" | ±2% | 0.35 | 3.25 | Wire Leads | 3/4" | PVC Plastic | 220° | 4 | 12, 24 | IP65, NEMA 4 | 00000000 | 0000000 |
| 85° to 930° | 3 1/2" | 3/4" | ±2% | 0.35 | 3.25 | Wire Leads | 3/4" | PVC Plastic | 220° | 4 | 12, 24 | IP65, NEMA 4 | 00000000 | 000000 |
Thermocouple Signal Converters
Convert thermocouple probe signals to a 4-20 mA signal for use with switches and controllers.

For Panel Cutout | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temp. Range, °F | DIN Trade Size | Ht. | Wd. | Ht. | Wd. | Dp. | AC Voltage (Phase) | Frequency, Hz | Housing Material | Display | Resolution | For Max. Wire Gauge | Each | |
For Probe Type J | ||||||||||||||
| -238° to 1400° | 1/8 | 1 3/4" | 3 5/8" | 1 7/8" | 3 7/8" | 6 1/16" | 120, 240 (Single) | 60 | Aluminum | LCD | 1 | 26 | 00000000 | 0000000 |
For Probe Type K | ||||||||||||||
| -58° to 1999° | 1/8 | 1 3/4" | 3 5/8" | 1 7/8" | 3 7/8" | 6 1/16" | 120, 240 (Single) | 60 | Aluminum | LCD | 1 | 26 | 00000000 | 000000 |
RTD Transmitters
Send temperature readings from RTD probes in containers, tanks, and pipes to switches and programmable logic controllers (PLCs).

For Panel Cutout | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For RTD Probe Type | Temperature Range, °C | DIN Trade Size | Ht. | Wd. | Ht. | Wd. | Dp. | AC Voltage (Phase) | Output Current | Housing Material | Display | Resolution | For Max. Wire Gauge | Each | |
Screw Terminal Connection Type | |||||||||||||||
| 100 ohms | -50° to 850° | 1/8 | 1 3/4" | 3 5/8" | 1 7/8" | 3 7/8" | 6 1/16" | 120, 240 (Single) | 4-20mA | Aluminum | LCD | 1 | 26 | 00000000 | 0000000 |