Number of Poles Number of Poles | Show |
---|
|
Type Type |
---|
![]() | ![]() |
Plug | Socket |
![]() | |
Receptacle |
Housing Connection Type Housing Connection Type |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | ![]() |
Solder | Screw Terminals |
![]() | |
Wire Leads |
Shape Shape |
---|
![]() | Straight |
Specifications Met Specifications Met |
---|
|
Trade Number Trade Number |
---|
|
System of Measurement System of Measurement |
---|
|
Housing Thread Size Housing Thread Size |
---|
|
Connector Shell Size Connector Shell Size |
---|
|
Housing Finish Housing Finish |
---|
|
Housing Thread Type Housing Thread Type |
---|
|
Rated to MIL-DTL-5015 specifications, these connectors are compatible with other products that meet the same standard. They can withstand high-vibration applications and frequent connection and disconnection. All come assembled with pins and sockets in place. When mating connectors, both the gender and housing thread location must be opposite.
Receptacles with wire markers identify the corresponding pole for each wire.
Caps (sold separately) protect connectors when not in use.
For technical drawings and 3-D models, click on a part number.
Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | For Cable OD | Lg. | Wd. | Ht. | Housing Material | Size | Type | Temp. Range, °F | Connector Shell Size | Trade Number | Each | |
2 | 500V AC/700V DC | 13A | 20-16 | 0.14"-0.3" | 2.3" | 0.6" | 1.1" | Cadmium-Plated Aluminum | 5/8"-24 | UNEF | -65° to 255° | 10SL | MS3101F10SL-4P | 0000000 | 000000 |
Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | For Cable OD | OD | Lg. | Housing Material | Size | Type | Temp. Range, °F | Connector Shell Size | Trade Number | Each | |
2 | 500V AC/700V DC | 13A | 20-16 | 0.14"-0.3" | 1" | 2.3" | Cadmium-Plated Aluminum | 5/8"-24 | UNEF | -65° to 255° | 10SL | MS3106F10SL-4P | 0000000 | 000000 |
Housing Thread | 30 ft. Lg. Cable Leads | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Shielding | OD | Lg. | Housing Material | Size | Type | Temp. Range, °F | Connector Shell Size | Trade Number | Each | |
2 | 300V AC/300V DC | 13A | 16 | 0.28" | Shielded | 1" | 2.3" | Cadmium-Plated Aluminum | 5/8"-24 | UNEF | -65° to 255° | 10SL | MS3106F10SL-4P | 00000000 | 0000000 |
Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | For Cable OD | Lg. | Wd. | Ht. | Housing Material | Size | Type | Temp. Range, °F | Connector Shell Size | Trade Number | Each | |
2 | 500V AC/700V DC | 13A | 20-16 | 0.14"-0.3" | 2.3" | 0.6" | 1.1" | Cadmium-Plated Aluminum | 5/8"-24 | UNEF | -65° to 255° | 10SL | MS3101F10SL-4S | 0000000 | 000000 |
Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | For Cable OD | OD | Lg. | Housing Material | Size | Type | Temp. Range, °F | Connector Shell Size | Trade Number | Each | |
2 | 500V AC/700V DC | 13A | 20-16 | 0.14"-0.3" | 1" | 2.3" | Cadmium-Plated Aluminum | 5/8"-24 | UNEF | -65° to 255° | 10SL | MS3106F10SL-4S | 0000000 | 000000 |
Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | Lg. | Wd. | Ht. | Housing Material | Size | Type | For Panel Cutout Dia. | Temp. Range, °F | Connector Shell Size | Trade Number | Each | |
2 | 500V AC/700V DC | 13A | 20-16 | 1" | 1" | 1" | Cadmium-Plated Aluminum | 5/8"-24 | UNEF | 0.625" | -65° to 255° | 10SL | MS3102R10SL-4P | 0000000 | 000000 |
Housing Thread | 3 ft. Wire Lead Lg. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Wire Lead Gauge | Lg. | Wd. | Ht. | Housing Material | Size | Type | For Panel Cutout Dia. | Temp. Range, °F | Connector Shell Size | Trade Number | Each | |
2 | 300V AC/300V DC | 13A | 16 | 1" | 1" | 1" | Cadmium-Plated Aluminum | 5/8"-24 | UNEF | 0.625" | -65° to 255° | 10SL | MS3102E10SL-4P | 00000000 | 000000 |
Housing Thread | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | Lg. | Wd. | Ht. | Housing Material | Size | Type | For Panel Cutout Dia. | Temp. Range, °F | Connector Shell Size | Trade Number | Each | |
2 | 500V AC/700V DC | 13A | 20-16 | 1" | 1" | 1" | Cadmium-Plated Aluminum | 5/8"-24 | UNEF | 0.625" | -65° to 255° | 10SL | MS3102R10SL-4S | 0000000 | 000000 |
Housing Thread | 3 ft. Wire Lead Lg. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Wire Lead Gauge | Lg. | Wd. | Ht. | Housing Material | Size | Type | For Panel Cutout Dia. | Temp. Range, °F | Connector Shell Size | Trade Number | Each | |
2 | 300V AC/300V DC | 13A | 16 | 1" | 1" | 1" | Cadmium-Plated Aluminum | 5/8"-24 | UNEF | 0.625" | -65° to 255° | 10SL | MS3102E10SL-4S | 00000000 | 000000 |
Combine power, USB, computer, and compressed air inserts to build a connector that sends signal, power, and data. A complete connector requires a hood, a base, two frames, and a male and female insert for each slot in the frame. The frames fit into the hood and base, and the inserts snap into the frame. Select components based on the number of slots needed. Once assembled, connectors are rated NEMA 4 and 12 for protection against dirt, washdowns, and oil/coolant dripping.
For technical drawings and 3-D models, click on a part number.
Number of Poles | Voltage | Current | For Wire Gauge | For Number of Frame Slots | Max. Temp., °F | Specifications Met | Each | |
Plug | ||||||||
---|---|---|---|---|---|---|---|---|
Screw Terminals | ||||||||
2 | 600V AC/600V DC | 40A | 14-9 | 1 | 255° | UL 94V0, DNV-GL Type Approved | 0000000 | 000000 |
2 | 600V AC/600V DC | 40A | 10-8 | 1 | 255° | UL 94V0, DNV-GL Type Approved | 00000000 | 00000 |
2 | 600V AC/600V DC | 70A | 8-6 | 1 | 255° | UL 94V0 | 0000000 | 00000 |
2 | 600V AC/600V DC | 70A | 4-2 | 1 | 255° | UL 94V0, DNV-GL Type Approved | 00000000 | 00000 |
2 | 600V AC/600V DC | 100A | 7-3 | 2 | 255° | UL 94V0, DNV-GL Type Approved | 00000000 | 00000 |
2 | 600V AC/600V DC | 100A | 6-2 | 2 | 255° | UL 94V0 | 0000000 | 00000 |
2 | 600V AC/600V DC | 100A | 2 | 2 | 255° | UL 94V0, DNV-GL Type Approved | 00000000 | 00000 |
Socket | ||||||||
Screw Terminals | ||||||||
2 | 600V AC/600V DC | 40A | 14-9 | 1 | 255° | UL 94V0, DNV-GL Type Approved | 0000000 | 00000 |
2 | 600V AC/600V DC | 40A | 10-8 | 1 | 255° | UL 94V0, DNV-GL Type Approved | 00000000 | 00000 |
2 | 600V AC/600V DC | 70A | 8-6 | 1 | 255° | UL 94V0 | 0000000 | 00000 |
2 | 600V AC/600V DC | 70A | 4-2 | 1 | 255° | UL 94V0, DNV-GL Type Approved | 00000000 | 00000 |
2 | 600V AC/600V DC | 100A | 7-3 | 2 | 255° | UL 94V0, DNV-GL Type Approved | 00000000 | 00000 |
2 | 600V AC/600V DC | 100A | 6-2 | 2 | 255° | UL 94V0 | 0000000 | 00000 |
2 | 600V AC/600V DC | 100A | 2 | 2 | 255° | UL 94V0, DNV-GL Type Approved | 00000000 | 00000 |
With a PVC housing, connectors withstand exposure to chemicals, oil, fuel, and salt water. Each set includes one plug and one socket. They’re often used in construction vehicles and machine tool applications. All come assembled with wire leads already installed so they can be quickly added to existing wiring systems. When mated, connectors meet IP67 for protection against washdowns.
For technical drawings and 3-D models, click on a part number.