Number of Poles Number of Poles | Show |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | ![]() |
Screw Terminals | Spring-Clamp Terminals |
Housing Material Housing Material |
---|
|
System of Measurement System of Measurement |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Current Current |
---|
|
Pin Finish Pin Finish |
---|
|
Pin Material Pin Material |
---|
|
Component Component |
---|
|
Sleeve Finish Sleeve Finish |
---|
|
Sleeve Material Sleeve Material |
---|
|
Protect connections while maintaining access. The base and hood latch together securely, yet can be quickly detached for equipment repair or replacement. They’re rated NEMA 12 for protection from dirt and oil/coolant dripping and IP65 for protection against water projected from a nozzle.
Aluminum connectors are rated NEMA 4X for protection against corrosion.
For technical drawings and 3-D models, click on a part number.
Conduit | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Trade Size | Thread Type | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Base Cover Style | Max. Temp., °F | Each | |
Side Conduit Connection—1 Latching Lever | |||||||||||||
Powder-Coated Aluminum | |||||||||||||
48 | 600V AC/600V DC | 16A | 1 1/4 | NPT | Screw Terminals | 18-14 | 6.5" | 3.8" | 5.4" | Attached | 255° | 0000000 | 0000000 |
Top Conduit Connection—1 Latching Lever | |||||||||||||
Powder-Coated Aluminum | |||||||||||||
48 | 600V AC/600V DC | 16A | 1 1/4 | NPT | Screw Terminals | 18-14 | 6.5" | 3.8" | 5.4" | Attached | 255° | 0000000 | 000000 |
Rated NEMA 4X, 12, and IP65, connectors protect against corrosion, washdowns, oil/coolant dripping, and water projected from a nozzle. They have a rubber seal and stainless steel hardware for excellent chemical resistance. Use them to protect connections while maintaining access. The base and hood latch together securely, yet can be quickly detached for equipment repair or replacement.
For technical drawings and 3-D models, click on a part number.
Conduit | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Trade Size | Thread Type | Connection Gender | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Base Cover Style | Max. Temp., °F | Each | |
Side Conduit Connection—1 Latching Lever | ||||||||||||||
Powder-Coated Aluminum | ||||||||||||||
48 | 600V AC/600V DC | 16A | 1 1/4 | NPT | Female | Screw Terminals | 18-14 | 6.5" | 3.8" | 5.4" | Attached | 255° | 0000000 | 0000000 |
Configure a connector for your application—combine male and female inserts with a base and a hood. Select components based on the number of poles needed. To protect connections while maintaining access, the base and hood latch together securely, yet can be quickly detached for equipment repair or replacement. Once assembled, these connectors are rated NEMA 4X, 12, and IP65 for protection against corrosion, washdowns, dirt, oil/coolant dripping, and water projected from a nozzle.
For technical drawings and 3-D models, click on a part number.
Inserts | Hoods with Side Conduit Connection | Hoods with Top Conduit Connection | Bases | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | Each | Conduit NPT Trade Size | Each | Conduit NPT Trade Size | Each | Each | ||||
Male | |||||||||||||
Spring-Clamp Terminals | |||||||||||||
48 | 600V AC/600V DC | 16A | 26-14 | 0000000 | 000000 | 1 | 0000000 | 000000 | 1 | 0000000 | 000000 | 0000000 | 000000 |
Screw Terminals | |||||||||||||
48 | 600V AC/600V DC | 16A | 18-14 | 0000000 | 00000 | 1 | 0000000 | 00000 | 1 | 0000000 | 00000 | 0000000 | 00000 |
Female | |||||||||||||
Spring-Clamp Terminals | |||||||||||||
48 | 600V AC/600V DC | 16A | 26-14 | 0000000 | 00000 | 1 | 0000000 | 00000 | 1 | 0000000 | 00000 | 0000000 | 00000 |
Screw Terminals | |||||||||||||
48 | 600V AC/600V DC | 16A | 18-14 | 0000000 | 00000 | 1 | 0000000 | 00000 | 1 | 0000000 | 00000 | 0000000 | 00000 |