System of Measurement System of Measurement |
---|
|
Pipe Size Pipe Size | Show |
---|
Material Material |
---|
|
Connection Style Connection Style |
---|
![]() |
Threaded |
![]() |
Socket Connect |
![]() |
Butt Weld |
![]() |
Flanged |
![]() |
Clamp On |
![]() |
Slip-On Weld |
![]() |
Stub End |
For Pipe Material For Pipe Material |
---|
|
For Use With For Use With |
---|
Specifications Met Specifications Met |
---|
|
Length Length |
---|
|
|
|
Connection Type Connection Type |
---|
![]() | Pipe |
Maximum Pressure Maximum Pressure |
---|
|
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
For information about selecting pipe size, see Selecting and Measuring Pipe & Fittings.
More
Bolt two flat-surface flanges or two raised-surface flanges of the same size together with a gasket (sold separately) to create an access point in a pipe line.
304 stainless steel flanges offer very good corrosion resistance, and 316 stainless steel flanges have excellent corrosion resistance.
Forged flanges have better strength than cast flanges.
Butt-weld flanges are also known as weld-neck flanges; the flange neck has a beveled end that, when flush to pipe, creates a trough for a strong weld. Slip-on weld flanges have no internal stop; slide a pipe through the flange and weld on both sides.
Stub-end flanges are also known as lap-joint flanges; use them with a stub-end straight adapter (not included). The stub-end straight adapter slides into the flange and welds to pipe (not the flange). Since the flange isn’t welded to the pipe, it can be disconnected easily for frequent cleaning and inspecting. Cap flanges are also known as blind flanges.
For technical drawings and 3-D models, click on a part number.
Also known as Schedule 10 fittings, these are thin and lightweight. They have beveled ends that, when flush to pipe, create a trough for a strong weld that permits maximum flow.
304 stainless steel fittings have very good corrosion resistance. 316 stainless steel fittings have excellent corrosion resistance.
Stub-end straight adapters are used with flanges. Slide a flange onto the stub end and weld the stub end to pipe (not the flange). Since the flange isn’t welded to the pipe, it can be disconnected easily, which creates an access point for frequent cleaning and inspecting.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Wall Thick. | |||||
---|---|---|---|---|---|---|
(A) | (B) | (A) | (B) | Construction | Each | |
304/304L Stainless Steel | ||||||
12 | 6 | 0.18" | 0.134" | Welded | 000000000 | 0000000 |
12 | 8 | 0.18" | 0.148" | Welded | 000000000 | 000000 |
12 | 10 | 0.18" | 0.165" | Welded | 000000000 | 000000 |
316/316L Stainless Steel | ||||||
12 | 6 | 0.18" | 0.134" | Welded | 000000000 | 000000 |
12 | 8 | 0.18" | 0.148" | Welded | 000000000 | 000000 |
12 | 10 | 0.18" | 0.165" | Welded | 000000000 | 000000 |
Also known as Schedule 10, this pipe is thin and lightweight. Weld it to fittings and additional lengths of pipe. Welded connections are stronger than threaded connections and less likely to leak. Pipe has a welded construction, so there is a weld bead on the inside.
304 stainless steel pipe has very good corrosion resistance. 316 stainless steel pipe has excellent corrosion resistance.
For technical drawings and 3-D models, click on a part number.
Use these flanges for low-pressure applications in noncorrosive environments. Bolt two flanges of the same size together with a gasket (sold separately) to create an access point within a line.
For technical drawings and 3-D models, click on a part number.
Bolt Hole | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Max. Pressure | Max. Steam Pressure | Material | Each | |
NPT | ||||||||||
12 | 19" | 7/8" | 1" | 12 | 17" | 285 psi @ 72° F | 230 psi @ 300° F | Steel | 000000000 | 0000000 |
Bolt two flat-surface flanges or two raised-surface flanges of the same size together with a gasket (sold separately) to create an access point in a pipe line. Flanges are for use with low-pressure applications in noncorrosive environments.
Butt-weld flanges are also known as weld-neck flanges; the flange neck has a beveled end that, when flush to pipe, creates a trough for a strong weld.
Slip-on weld flanges have no internal stop; slide a pipe through the flange and weld on both sides.
Socket-connect flanges have an internal stop that supports the pipe when welding and prevents the pipe from sliding all the way through.
Stub-end flanges are also known as lap-joint flanges; use them with a stub-end straight adapter (not included). The stub-end straight adapter slides into the flange and welds to pipe (not the flange). Since the flange isn’t welded to the pipe, it can be disconnected easily for frequent cleaning and inspecting.
Cap flanges are also known as blind flanges.
For technical drawings and 3-D models, click on a part number.
Bolt Hole | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Wall Thick. | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Class | Construction | Max. Pressure | Max. Steam Pressure | Certification | Specifications Met | Each | |
12 | 0.406" | 19" | 7/8" | 1" | 12 | 17" | 150 | Seamless | 285 psi @ 72° F | 150 psi @ 300° F | Material Certificate with Traceable Lot Number and Test Report | ANSI/ASME B16.5, ASTM A105, MSS SP-25 | 00000000 | 0000000 |
Bolt Hole | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Class | Max. Pressure | Max. Steam Pressure | Certification | Specifications Met | Each | |
12 | 19" | 7/8" | 1" | 12 | 17" | 150 | 285 psi @ 72° F | 150 psi @ 300° F | Material Certificate with Traceable Lot Number and Test Report | ANSI/ASME B16.5, ASTM A105, MSS SP-25 | 00000000 | 0000000 |
Bolt Hole | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Max. Pressure | Max. Steam Pressure | Specifications Met | Each | |
12 | 19" | 7/8" | 1" | 12 | 17" | 285 psi @ 72° F | Not Rated | ASTM A105 | 00000000 | 0000000 |
Bolt Hole | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Max. Pressure | Max. Steam Pressure | Each | |
12 | 19" | 7/8" | 1" | 12 | 17" | 285 psi @ 72° F | 150 psi @ 300° F | 00000000 | 0000000 |
Bolt Hole | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Class | Max. Pressure | Max. Steam Pressure | Specifications Met | Each | |
12 | 19" | 7/8" | 1" | 12 | 17" | 150 | 285 psi @ 72° F | 150 psi @ 300° F | ANSI/ASME B16.5, ASTM A105, MSS SP-25 | 00000000 | 0000000 |
Forged for extra strength, these heavy duty flanges can withstand high-pressure applications. Bolt two flat-surface flanges or two raised-surface flanges of the same size together with a gasket (sold separately) to create an access point in a pipe line.
Butt-weld flanges are also known as weld-neck flanges; the flange neck has a beveled end that, when flush to pipe, creates a trough for a strong weld.
Slip-on weld flanges have no internal stop; slide a pipe through the flange and weld on both sides.
Socket-connect flanges have an internal stop that supports the pipe when welding and prevents the pipe from sliding all the way through.
Stub-end flanges are also known as lap-joint flanges; use them with a stub-end straight adapter (not included). The stub-end straight adapter slides into the flange and welds to pipe (not the flange). Since the flange isn’t welded to the pipe, it can be disconnected easily for frequent cleaning and inspecting.
Cap flanges are also known as blind flanges.
For technical drawings and 3-D models, click on a part number.
Bolt Hole | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Wall Thick. | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Max. Pressure | Max. Steam Pressure | Material | Each | |
300 Class | |||||||||||
12 | 0.688" | 20 1/2" | 1 1/4" | 1 1/4" | 16 | 17 3/4" | 600 psi @ 72° F | 300 psi @ 300° F | Black-Coated Steel | 00000000 | 0000000 |
Bolt Hole | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Max. Pressure | Max. Steam Pressure | Material | Each | |
300 Class | ||||||||||
12 | 20 1/2" | 1 1/4" | 1 1/4" | 16 | 17 3/4" | 600 psi @ 72° F | 300 psi @ 300° F | Black-Coated Steel | 00000000 | 0000000 |
Bolt Hole | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Max. Pressure | Max. Steam Pressure | Material | Specifications Met | Each | |
300 Class | |||||||||||
12 | 20 1/2" | 1 1/4" | 1 1/4" | 16 | 17 3/4" | Not Rated | Not Rated | Black-Coated Steel | ASTM A105 | 00000000 | 0000000 |
Bolt Hole | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Max. Pressure | Max. Steam Pressure | Material | Each | |
300 Class | ||||||||||
12 | 20 1/2" | 1 1/4" | 1 1/4" | 16 | 17 3/4" | 600 psi @ 72° F | 300 psi @ 300° F | Black-Coated Steel | 00000000 | 0000000 |
Bolt Hole | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. of | Bolt Circle Dia. | Max. Pressure | Max. Steam Pressure | Material | Each | |
300 Class | ||||||||||
12 | 20 1/2" | 1 1/4" | 1 1/4" | 16 | 17 3/4" | 600 psi @ 72° F | 300 psi @ 300° F | Black-Coated Steel | 00000000 | 0000000 |
Connect these fittings to Schedule 80 pipe–they have thicker, stronger walls than standard-wall fittings so they can handle heavy duty industrial plumbing and water supply applications, such as water processing, waste water treatment, and irrigation. Fittings are plastic for good corrosion resistance. They meet ASTM D1784 specifications and testing requirements for material quality.
Fittings for drinking water meet NSF/ANSI Standard 61.
Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Socket Depth | Material | Color | Each | |
12 | 6" | PVC Plastic | Dark Gray | 00000000 | 0000000 |
Pipe Size | Socket Depth | Material | Color | Each | |
12 | 6 1/16" | PVC Plastic | Dark Gray | 00000000 | 000000000 |
Pipe Size | Socket Depth | Material | Color | Each | |
12 | 6" | PVC Plastic | Dark Gray | 00000000 | 000000000 |
Pipe Size | Socket Depth | Material | Color | Each | |
12 | 6" | PVC Plastic | Dark Gray | 00000000 | 0000000 |
Type | Each | |
Cement Adhesive for 12" Maximum Pipe Dia. | 00000000 | 00000 |
With thicker, stronger walls than standard-wall pipe, this Schedule 80 pipe can handle heavy duty industrial plumbing and water supply applications, such as water processing, waste water treatment, and irrigation. It’s made of PVC, which has good corrosion resistance. Pipe meets ASTM D1784 and ASTM D1785 specifications and testing requirements for material quality.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
Pipe for drinking water meets NSF/ANSI Standard 61.
Connect unthreaded pipe to unthreaded female socket-connect fittings using a PVC primer and cement (also known as solvent weld).
Also known as Class 150 flanges, these flanges have thick, strong walls to handle heavy duty industrial plumbing and water supply applications, such as water processing, waste water treatment, and irrigation. They meet NSF/ANSI Standard 61 for drinking water. Bolt two same-size flanges together with a gasket (sold separately) to create an access point within a line. Flanges are PVC, which has good corrosion resistance. They meet ASTM D1784 specifications and testing requirements for material quality.
Warning: Never use plastic pipe flanges and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
Rotating flanges are also known as Van Stone flanges; they swivel for easy bolt hole alignment.
Cap flanges are also known as blind flanges.
Bolt Hole | ||||||||
---|---|---|---|---|---|---|---|---|
Pipe Size | Flange OD | For Bolt Dia. | Dia. | No. | Bolt Circle Dia. | Color | Each | |
12 | 19" | 7/8" | 1" | 12 | 17" | Dark Gray | 00000000 | 0000000 |
Connect these fittings to Schedule 40 plastic pipe–they are the industry standard for residential and commercial low-pressure plumbing and water supply applications. They are plastic for good corrosion resistance.
Fittings for drinking water meet NSF/ANSI Standard 61.
Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with a PVC primer and cement (also known as solvent weld).
Fittings that meet ASTM D1784, ASTM D1785, and ASTM D4066 adhere to specifications and testing requirements for material quality.
Note: For fittings that are not rated for pressure, you can use the pressure rating of the plastic pipe as a reference. Threaded fittings are limited to 50% of the rated pressure of the pipe.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
Connect this pipe to standard-wall plastic pipe fittings for a variety of residential and commercial low-pressure plumbing and water supply applications. It’s made of PVC, which has good corrosion resistance. Connect to unthreaded female socket-connect fittings using a PVC primer and cement (also known as solvent weld).
Pipe for drinking water meets NSF/ANSI Standard 61.
Pipe that meets ASTM D1784 and ASTM D1785 adheres to specifications and testing requirements for material quality.
Bend radius is the point to which you can bend pipe or tubing without damaging it. The smaller the measurement, the better the bend.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.
Clear pipe allows you to see what’s flowing through the line.
These joints reduce stress, vibration, and noise in piping systems by providing a point of flexibility to absorb movement. The flanged ends rotate for easy bolt hole alignment during installation. They mate with a same-size flat-surface Class 150 flange without the need for a gasket. Joints have a flexible body that is reinforced with nylon for added strength.
For technical drawings and 3-D models, click on a part number.
Distance | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flange OD | Pipe Size | Lg. | No. of Bolt Holes | Compression | Expansion | Offset | Expansion Joint Type | Flange Material | Bolt Hole Thread Size | Each | |
19" | 12 | 8" | 12 | 1" | 5/8" | 3/4" | Single Bulb | Zinc-Plated Steel | 7/8"-9 | 0000000 | 0000000 |
Distance | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flange OD | Pipe Size | Lg. | No. of Bolt Holes | Compression | Expansion | Offset | Expansion Joint Type | Flange Material | For Bolt Dia. | Each | |
19" | 12 | 8" | 12 | 1" | 5/8" | 3/4" | Single Bulb | Zinc-Plated Steel | 1" | 0000000 | 0000000 |
Distance | Unthreaded Bolt Holes | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flange OD | Pipe Size | Lg. | No. of Bolt Holes | Compression | Expansion | Offset | Expansion Joint Type | Flange Material | For Bolt Dia. | Each | |
19" | 12 | 8" | 12 | 1" | 5/8" | 3/4" | Single Bulb | Zinc-Plated Steel | 1" | 0000000 | 0000000 |
These all-metal expansion joints can handle higher temperatures than rubber expansion joints. They reduce stress, vibration, and noise in piping systems by providing a point of flexibility to absorb movement. Joints are made of 304 stainless steel for very good corrosion resistance. The flanged ends rotate for easy bolt hole alignment during installation. Flanges mate with a same-size flat-surface Class 150 flange with a gasket (sold separately).
Liners (sold separately) slide into the expansion joint to provide a smooth interior for unrestricted flow.
For technical drawings and 3-D models, click on a part number.
These expansion joints have a double-bulb design for extra movement and vibration absorption. The flanged ends rotate for easy bolt hole alignment during installation. They mate with a same-size flat-surface Class 150 flange without the need for a gasket. Joints have a flexible body that is reinforced with nylon for added strength.
For technical drawings and 3-D models, click on a part number.
Distance | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flange OD | Pipe Size | Lg. | No. of Bolt Holes | Compression | Expansion | Offset | Expansion Joint Type | Flange Material | Bolt Hole Thread Size | Each | |
19" | 12 | 13" | 12 | 2 3/8" | 1 3/8" | 1 3/8" | Double Bulb | Zinc-Plated Steel | 7/8"-9 | 0000000 | 0000000 |
Distance | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flange OD | Pipe Size | Lg. | No. of Bolt Holes | Compression | Expansion | Offset | Expansion Joint Type | Flange Material | Bolt Hole Size | Each | |
19" | 12 | 13" | 12 | 2 3/8" | 1 3/8" | 1 3/8" | Double Bulb | Zinc-Plated Steel | 1" | 0000000 | 0000000 |
Distance | Unthreaded Bolt Holes | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flange OD | Pipe Size | Lg. | No. of Bolt Holes | Compression | Expansion | Offset | Expansion Joint Type | Flange Material | Bolt Hole Size | Each | |
19" | 12 | 13" | 12 | 2 3/8" | 1 3/8" | 1 3/8" | Double Bulb | Zinc-Plated Steel | 1" | 0000000 | 0000000 |
Slip these joints over your pipe ends and tighten the band clamps for a secure hold. Joints have a triple-bulb design that provides excellent vibration absorption to reduce stress on your piping system. They also have reinforcing rings for extra support during pressure surges and in vacuum applications.
Neoprene rubber joints are more abrasion resistant than silicone rubber joints.
For technical drawings and 3-D models, click on a part number.
Distance | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Pipe OD | Pipe Size | Lg. | Compression | Expansion | Offset | Expansion Joint Type | Reinforcement Material | Band Clamp Material | Each | |
Neoprene Rubber | ||||||||||
12 3/4" | 12 | 7" | 1" | 1/2" | 1 1/8" | Triple Bulb | Nylon Plastic | 300 Series Stainless Steel | 0000000 | 0000000 |
Silicone Rubber | ||||||||||
12 3/4" | 12 | 7" | 1" | 1/2" | 1 1/8" | Triple Bulb | Fiberglass | 300 Series Stainless Steel | 00000000 | 000000 |