For Use With For Use With |
---|
|
Housing Material Housing Material |
---|
|
Discharge Pipe Connection Type Discharge PipeConnection Type |
---|
|
Specifications Met Specifications Met |
---|
|
Pump Type Pump Type |
---|
|
More
Hang these switches in a sump pit to detect rising water levels. Use them to replace an existing switch, or pair them with a plug-in activated pump to control when the pump activates.
Since these switches activate on increasing pressure caused by rising water levels, they have no floats to catch on sump pit walls. Use them to replace an existing switch, or pair them with a plug-in activated pump to control when the pump activates.
Switch with wire leads can be connected to a three-pronged plug or wired directly to a power source.
If the primary float fails, the backup float kicks in and an alarm sounds to indicate float malfunction. The floats are enclosed in a mounting cage to minimize false switch activation. Use the switch to replace an existing switch, or pair it with a plug-in activated pump that operates on 15 amps or less to control when the pump activates.
Voltage | Current, A | Max. Temp., °F | Plug Type | Cord Lg., ft. | Features | Includes | Each | |
120V AC | 12 | 100° | Three Prong | 4 | Mounting Cage | Stainless Steel Clamp | 0000000 | 000000 |
Activate your pump in dirty water that contains sludge and sewage. This switch has no moving parts for a longer life than float switches. Use it to replace an existing switch, or pair it with a plug-in activated pump to control when the pump activates.
Voltage | Current, A | Temperature Range, °F | Plug Type | Cord Lg., ft. | Each | |
120V AC | 12 | 35° to 120° | Three Prong | 15 | 0000000 | 0000000 |
To prevent contamination, these switches won’t activate if they sense oil in your sump pit. They have a probe to detect the liquid level—it activates when it senses water and deactivates when it senses oil. Use these switches to replace an existing switch, or pair them with a plug-in activated pump to control when the pump activates.
Voltage | Current, A | Temperature Range, °F | Plug Type | Cord Lg., ft. | Specifications Met | Each | |
120V AC | 16 | 35° to 170° | Three Prong | 20 | CE Marked, UL Listed | 0000000 | 0000000 |
Kits include tubing, a backflow-prevention valve, an adapter, and a clamp.
Includes | Each | |
24 ft. of Polyethylene Tubing (1 1/4 NPT Female) ABS Backflow-Prevention Valve (NPT Male) Polypropylene Male Adapter (1 1/4 NPT Male) Stainless Steel Clamp | 0000000 | 000000 |
24 ft. of Polyethylene Tubing (1 1/2 NPT Female) ABS Backflow-Prevention Valve (NPT Male) Polypropylene Male Adapter (1 1/2 NPT Male) Stainless Steel Clamp | 0000000 | 00000 |
This unthreaded rubber strainer fits onto 3/4 NPT male connections.
Each | ||
0000000 | 000000 |
Place your pump inside this basin for ground-level applications and below-ground use without a sump pit. Basin has a vent on top.
Discharge | Pressure Port | Overall | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Temp., °F | Dia. | Dp. | Each | |
2 | NPT | Female | 2 | NPT | Female | 130° | 18" | 30" | 0000000 | 0000000 |
An alarm and a red light alert you when water levels rise too high. A float detects water level and activates the alarm. Alarm has a plastic housing that meets NEMA 3R for protection from dirt, falling liquids, and light splashing.
Voltage | Plug Type | Cord Lg., ft. | Each | |
120V AC | Three Prong | 20 | 0000000 | 0000000 |
Don’t let a power outage cause flooding. Powered by water flow in your supply line, this pump works as a backup to your primary sump pump. Use with debris-free water. Intake has a foot valve to prevent debris from entering your line. The water inlet has 3/4 NPT female threads and comes with a push-to-connect fitting for 3/4" ID tubing, so you can make either connection. The float switch is wired to the pump.
Max. Flow Rate, gpm | Water Inlet | Discharge | Min. Sump Pit | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 4 Ft. of Head | @ 8 Ft. of Head | @ 15 Ft. of Head | Water Pressure, psi | Max. Temp., °F | Pipe Size | Thread Type | Gender | Pipe Connection Type | Pipe Size | Gender | For Pipe Schedule | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
15.4 | 12.5 | 7.2 | 30-100 | 130° | 3/4 | NPT | Female | Socket Connect | 1 1/2 | Female | 40 | 18" | 22" | 22" | 15" | 22" | 0000000 | 0000000 |