About Air Preparation
More
About Safety Ratings for Electrical Testing
More
Caps for Outlets and Plugs
Cover unused electrical outlets or plug prongs to protect them from dust, dirt, liquids, and other contaminants.
For NEMA Style | Material | Color | Pkg. Qty. | Pkg. | |
For Three Prongs | |||||
---|---|---|---|---|---|
5-15 | Plastic | Clear | 10 | 0000000 | 00000 |
Power Consumption Meters
Measure the amount of power your devices draw and calculate energy costs with these consumption meters. Plug them directly into an outlet, and plug your tool or appliance into the front of the meter. To track your power costs, enter the local price per kilowatt-hour (kWh) into the meter, and they’ll display the total amount you’re spending. They also help you monitor the quality of electricity coming from your outlet.
These meters meet U.S. and international safety standards. Rated CAT II, 150V, they can be safely used with most single-phase AC appliances and tools.
Max. Power, W | Max. AC Voltage | AC Voltage Accuracy | Max. AC Current, A | Current Accuracy | Max. Frequency, Hz | Max. Power Consumption, kWh | Max. Electrical Cost | Ht. | Wd. | Dp. | Specifications Met | Plug Type | Features | Each | |
1,800 | 150V AC | 1% | 15 | 1% | 65 | 9,999 | $9,999 | 5.1" | 2.6" | 1 1/2" | UL Listed, CSA Certified, CE Marked, ETL Listed | Three Prong | Backup Battery | 0000000 | 000000 |
USB Charging Stations
Charge multiple devices at once. These stations have removable dividers to fit thicker devices.
Stations with a keyed lock secure devices while charging. They come with two keys. Stations that have a cable and combination lock can be secured to a desk, cart, or other flat surface.
Stations with a USB B port connect to computers with a USB cord (not included). This is useful when pushing software updates, backing up data, or restoring default settings for multiple devices.
Stations cannot be sold to the listed areas due to energy efficiency regulations.
For technical drawings and 3-D models, click on a part number.
USB A Connection | Compartments | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Current, A | No. of | Wd. | Dp. | Cord Length, ft. | Input Voltage | Material | Height | Width | Depth | Features | Each | |
10 | 2.4 | 13 | 1/2" | 3 3/4" | 6 | 120V AC, 230V AC | Plastic | 3 1/4" | 9 3/8" | 4 3/4" | Removable Dividers | 0000000 | 0000000 |
USB A Connection | Compartments | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Current, A | No. of | Wd. | Dp. | Cord Length, ft. | Input Voltage | Material | Height | Width | Depth | Features | Includes | Cannot Be Sold To | Each | |
10 | 2.4 | 10 | 1 1/4" | 7 1/2" | 6 | 120V AC | Plastic | 13 1/2" | 16 1/2" | 8 15/16" | Removable Dividers, Removable Cover | 6 ft. Long Cable with Combination Lock | CA, VT | 0000000 | 0000000 |
No. of Connections | Compartments | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
USB A | USB B | USB A Current, A | No. of | Wd. | Dp. | Cord Length, ft. | Input Voltage | Material | Height | Width | Depth | Features | Cannot Be Sold To | Each | |
16 | 1 | 2.4 | 16 | 3/4" | 8" | 10 | 120V AC, 230V AC | Steel | 17 3/4" | 23 5/8" | 14 1/2" | Removable Dividers | CA, VT | 0000000 | 0000000 |
Timer-Operated Compressed Air Drain Valves
Set the electronic timer on these drain valves to open automatically at your specified time interval. They’re excellent for compressed air systems with high oil content because they resist clogging when water, oil, and sediment combine to form sludge. Install drain valves after separators, dryers, filters, and aftercoolers to collect and remove water from your air line.
Drain valves that meet NEMA 4 are rated for protection from dirt and washdowns. Drain valves that meet NEMA 4X are rated for protection from dirt, washdowns, and corrosion.
Install optional strainers before drain valves to prevent damage from debris in your pipeline.
For technical drawings and 3-D models, click on a part number.
Drain Valves | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Overall | Optional Strainers | ||||||||||||||
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Discharge Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | Cycle Interval | Drain Time | Max. Temp., °F | Each | Each | ||
Brass Housing—IP65, NEMA 4 Enclosure | |||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 4.8 | 230 | 4 1/4" | 1 3/4" | 3 1/2" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 0000000 | 0000000 | 000000 |
1/4 | NPT | Female | 1/4 | NPT | Female | 15 | 300 | 4 5/8" | 2 1/2" | 3 5/8" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 000000 | 0000000 | 00000 |
3/8 | NPT | Female | 3/8 | NPT | Female | 7 | 230 | 4 1/4" | 1 3/4" | 3 1/2" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 000000 | 0000000 | 00000 |
3/8 | NPT | Female | 3/8 | NPT | Female | 19 | 300 | 4 5/8" | 2 1/2" | 3 5/8" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 000000 | 0000000 | 00000 |
1/2 | NPT | Female | 1/2 | NPT | Female | 7 | 230 | 4 1/4" | 1 3/4" | 3 1/2" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 000000 | 0000000 | 00000 |
1/2 | NPT | Female | 1/2 | NPT | Female | 15 | 300 | 4 5/8" | 2 1/2" | 3 5/8" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 000000 | 0000000 | 00000 |
Brass Housing—NEMA 1 Enclosure | |||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 1.2 | 200 | 3 1/4" | 4" | 4 1/4" | 1-60 min. | 1-30 sec. | 120° | 0000000 | 000000 | 0000000 | 00000 |
Brass Housing—NEMA 4X Enclosure | |||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 2.9 | 200 | 4 1/8" | 6" | 3 3/4" | 0-50 min. | 1-15 sec. | 180° | 0000000 | 000000 | 0000000 | 00000 |
1/2 | NPT | Female | 1/2 | NPT | Female | 6 | 300 | 4" | 6" | 3 3/4" | 0-50 min. | 1-15 sec. | 180° | 00000000 | 000000 | 0000000 | 00000 |
Replacement Filter Screens for Optional Strainers | 0000000 | Each | 00000 |
High-Pressure Timer-Operated Compressed Air Drain Valves
These withstand at least double the pressure of our other timer-operated drain valves. Set the electronic timer to open automatically at your specified time interval. These drain valves are excellent for compressed air systems with high oil content because they resist clogging when water, oil, and sediment combine to form sludge. Install drain valves after separators, dryers, filters, and aftercoolers to collect and remove water from your air line.
Drain valves that meet NEMA 4 are rated for protection from dirt and washdowns. Drain valves that meet NEMA 4X are rated for protection from dirt, washdowns, and corrosion.
Install optional strainers before drain valves to prevent damage from debris in your pipeline.
For technical drawings and 3-D models, click on a part number.
Drain Valves | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Overall | Optional Strainers | ||||||||||||||
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Discharge Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | Cycle Interval | Drain Time | Max. Temp., °F | Each | Each | ||
Brass Housing—IP65, NEMA 4 Enclosure | |||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 3 | 1,200 | 4 1/2" | 2" | 3 3/8" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 0000000 | 000000 | 00 |
3/8 | NPT | Female | 3/8 | NPT | Female | 4 | 1,200 | 4 1/2" | 2" | 3 3/4" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 000000 | 000000 | 00 |
1/2 | NPT | Female | 1/2 | NPT | Female | 3 | 1,200 | 4 1/2" | 2" | 3 3/8" | 1-45 min. | 0.5-10 sec. | 130° | 0000000 | 000000 | 000000 | 00 |
1/2 | NPT | Female | 1/2 | NPT | Female | 18 | 600 | 6" | 6 3/8" | 3" | 1-24 hrs. | 1-15 min. | 140° | 00000000 | 000000 | 000000 | 00 |
Bronze Housing—NEMA 4X Enclosure | |||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||||
1/2 | NPT | Female | 1/2 | NPT | Female | 1.25 | 600 | 7" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 0000000 | 000000 |
3/4 | NPT | Female | 3/4 | NPT | Female | 2.5 | 600 | 7 1/2" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
1 | NPT | Female | 1 | NPT | Female | 4.3 | 600 | 7 3/4" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
316 Stainless Steel Housing—NEMA 4X Enclosure | |||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||||
1/2 | NPT | Female | 1/2 | NPT | Female | 1.25 | 2,000 | 7" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
3/4 | NPT | Female | 3/4 | NPT | Female | 2.5 | 600 | 7 1/2" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
1 | NPT | Female | 1 | NPT | Female | 4.3 | 600 | 7 3/4" | 7 5/8" | 4" | 1-50 min. | 5 sec. | 180° | 00000000 | 000000 | 000000 | 00 |
Replacement Filter Screens for Optional Strainers | 0000000 | Each | 00000 |
Timer-Operated Compressed Air Drain Valves with Digital Display
Use the digital display to set these valves to open automatically at precise intervals. They’re excellent for compressed air systems with high oil content because they resist clogging when water, oil, and sediment combine to form sludge. Install drain valves after separators, dryers, filters, and aftercoolers to collect and remove water from your air line. They meet NEMA 4 for protection from dirt and washdowns.
Install optional strainers before drain valves to prevent damage from debris in your pipeline.
For technical drawings and 3-D models, click on a part number.
Drain Valves | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Overall | Optional Strainers | |||||||||||||||
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Discharge Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | Cycle Interval | Drain Time | Display Type | Max. Temp., °F | Each | Each | ||
Brass Housing with LED Display—IP65, NEMA 4 Enclosure | ||||||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | ||||||||||||||||||
1/4 | NPT | Female | 1/4 | NPT | Female | 7 | 230 | 3 3/4" | 1 3/4" | 3 1/2" | 0-99 hrs. | 0-99 hrs. | LED | 130° | 000000 | 0000000 | 0000000 | 000000 |
3/8 | NPT | Female | 3/8 | NPT | Female | 7 | 230 | 3 3/4" | 1 3/4" | 3 1/2" | 0-99 hrs. | 0-99 hrs. | LED | 130° | 000000 | 000000 | 0000000 | 00000 |
1/2 | NPT | Female | 1/2 | NPT | Female | 7 | 230 | 3 3/4" | 1 3/4" | 3 1/2" | 0-99 hrs. | 0-99 hrs. | LED | 130° | 000000 | 000000 | 0000000 | 00000 |
Replacement Filter Screens for Optional Strainers | 0000000 | Each | 00000 |
No-Air-Loss Compressed Air Drain Valves
Save energy by minimizing the loss of compressed air. Unlike other drain valves, these only open when they're full. They close before the reservoir is completely empty, so no air escapes from the system. Install them at low points in your air line after separators, dryers, filters, and aftercoolers.
Electric-powered valves have a sensor. When condensate inside the valve rises to the level of the sensor, the valve opens to drain. Valves detect when they’re blocked—they automatically open and close to attempt to remove the blockage and sound an alarm if they’re still blocked. Drain valves with a contact for remote signaling device can be wired to activate a remote alarm if blocked.
For technical drawings and 3-D models, click on a part number.
Inlet | Outlet | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | For Tube ID | Pipe Size | Thread Type | Gender | Discharge Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | Max. Temp., °F | Features | Each | |
Aluminum Housing | |||||||||||||||
Electric Powered, 120V AC—Three-Prong Plug | |||||||||||||||
1/2 | NPT | Female | 3/8" | 1/4 | NPT | Male | 2.9 | 230 | 4 1/2" | 3 3/8" | 7" | 120° | Alarm, Contact for Remote Signaling Device | 0000000 | 0000000 |