For Use With For Use With |
---|
|
Flow Pattern Flow Pattern |
---|
![]() |
3/2 |
![]() |
5/2 |
![]() |
5/3 (Exhaust Center) |
Body Material Body Material |
---|
|
For Air Cylinder Type For Air Cylinder Type |
---|
|
Valve Function Valve Function |
---|
|
Connection Style Connection Style |
---|
![]() | ![]() |
Threaded | Yor-Lok |
![]() | |
Quick Clamp |
Maximum Pressure Maximum Pressure |
---|
|
Overall Length Overall Length |
---|
|
|
|
Overall Height Overall Height |
---|
|
|
|
Exhaust Connection Type Exhaust Connection Type |
---|
|
Vacuum Rating Vacuum Rating |
---|
|
|
More
More
More
More
Manually control these valves by pushing or turning the actuator. Also known as 3-way or 3/2 valves, they create one action, such as extending a cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated.
Normally closed valves block airflow until actuated. Valves that are both normally closed and normally open can be installed to block airflow, or allow air to flow until actuated.
Valves with hand return actuation stay actuated and go back to their starting position only when you move the actuator again. Valves with spring return actuation go back to their starting position as soon as you release the actuator.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
Overall | For Panel Cutout | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Actuator Color | Lg. | Wd. | Ht. | Dia. | Wd. | Lg. | Mounting Fasteners Included | Each | ||
Normally Closed Flow Positions | ||||||||||||||||||
Hand Return Actuation | ||||||||||||||||||
D | 3 | 10-32 UNF | 10-32 UNF | Threaded | 16.2 | 0.25 | 0-125 | 26 | __ | 5/8" | 5/8" | 2 1/8" | 1/2" | __ | __ | Yes | 0000000 | 000000 |
E | 3 | 1/8 NPT | 1/8 NPT | Threaded | 25 | 0.442 | 0-300 | Not Rated | __ | 7/8" | 5/8" | 3" | 1/2" | __ | __ | Yes | 00000000 | 00000 |
H | 3 | 10-32 UNF | 10-32 UNF | None (To Atmosphere) | 14.4 | 0.24 | 0-125 | Not Rated | Black | 5/8" | 5/8" | 2 1/4" | 1/2" | __ | __ | Yes | 00000000 | 00000 |
J | 3 | 1/8 NPT | 1/8 NPT | None (To Atmosphere) | 17.8 | 0.29 | 0-125 | Not Rated | Black | 1 1/4" | 5/8" | 2 1/2" | 1/2" | __ | __ | Yes | 00000000 | 00000 |
Spring Return Actuation | ||||||||||||||||||
D | 3 | 10-32 UNF | 10-32 UNF | Threaded | 16.2 | 0.25 | 0-125 | 26 | __ | 5/8" | 5/8" | 2 1/8" | 1/2" | __ | __ | Yes | 0000000 | 00000 |
J | 3 | 1/8 NPT | 1/8 NPT | None (To Atmosphere) | 17.8 | 0.29 | 0-125 | Not Rated | Black | 1 1/4" | 5/8" | 2 1/2" | 1/2" | __ | __ | Yes | 00000000 | 00000 |
Normally Open/Normally Closed Flow Positions | ||||||||||||||||||
Hand Return Actuation | ||||||||||||||||||
L | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 23 | __ | 1 3/4" | 3/4" | 2 1/2" | 1/2" | 3/4" | 1 3/4" | Yes | 0000000 | 00000 |
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Lg. | Wd. | Ht. | For Panel Cutout Dia. | Mounting Fasteners Included | Each | ||
Normally Closed Flow Positions | |||||||||||||||
Hand Return Actuation | |||||||||||||||
H | 3 | 1/8 NPT | 10-32 UNF | None (To Atmosphere) | 14.4 | 0.24 | 0-125 | Not Rated | 5/8" | 5/8" | 2 1/4" | 1/2" | Yes | 00000000 | 000000 |
J | 3 | 1/8 NPT | 1/8 NPT | None (To Atmosphere) | 17.8 | 0.29 | 0-125 | Not Rated | 1 1/4" | 5/8" | 2 3/8" | 1/2" | Yes | 00000000 | 00000 |
Spring Return Actuation | |||||||||||||||
H | 3 | 1/8 NPT | 10-32 UNF | None (To Atmosphere) | 14.4 | 0.24 | 0-125 | Not Rated | 5/8" | 5/8" | 2 1/4" | 1/2" | Yes | 00000000 | 00000 |
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | For Inlet Tube OD | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Lg. | Wd. | Ht. | For Panel Cutout Dia. | Mounting Fasteners Included | Each | ||
Normally Open/Normally Closed Flow Positions | |||||||||||||||
Hand Return Actuation | |||||||||||||||
K | 3 | 5/32" | 1/8 NPT | None (To Atmosphere) | 2.63 | 0.006 | 0-145 | Not Rated | 1 1/8" | 5/8" | 2 1/8" | 1/2" | No | 00000000 | 000000 |
K | 3 | 1/4" | 1/4 NPT | None (To Atmosphere) | 9.12 | 0.115 | 0-145 | Not Rated | 1 1/4" | 3/4" | 2 1/2" | 1/2" | No | 00000000 | 00000 |
K | 3 | 1/4" | 1/8 NPT | None (To Atmosphere) | 6.72 | 0.048 | 0-145 | Not Rated | 1 1/8" | 5/8" | 2 1/8" | 1/2" | No | 00000000 | 00000 |
K | 3 | 3/8" | 1/4 NPT | None (To Atmosphere) | 10.9 | 0.139 | 0-145 | Not Rated | 1 1/2" | 3/4" | 2 1/2" | 1/2" | No | 00000000 | 00000 |
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | For Inlet Tube OD | For Outlet Tube OD | Exhaust Connection Type | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Lg. | Wd. | Ht. | For Panel Cutout Dia. | Mounting Fasteners Included | Max. Flow Rate, scfm @ 100 psi | Each | ||
Normally Closed Flow Positions | |||||||||||||||
Hand Return Actuation | |||||||||||||||
J | 3 | 1/4" | 1/4" | None (To Atmosphere) | 0.29 | 0-125 | Not Rated | 1 1/4" | 5/8" | 2 5/8" | 1/2" | Yes | 17.8 | 00000000 | 000000 |
Spring Return Actuation | |||||||||||||||
J | 3 | 1/4" | 1/4" | None (To Atmosphere) | 0.29 | 0-125 | Not Rated | 1 1/4" | 5/8" | 2 5/8" | 1/2" | Yes | 17.8 | 00000000 | 00000 |
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | For Inlet Tube ID | For Outlet Tube ID | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | For Panel Cutout Dia. | Mounting Fasteners Included | Each | ||
Normally Closed Flow Positions | |||||||||||||||
Hand Return Actuation | |||||||||||||||
F | 3 | 1/16" | 1/16" | None (To Atmosphere) | 1.4 | 0.025 | 0-100 | Not Rated | 3/8" | 3/8" | 1 1/2" | 1/4" | Yes | 00000000 | 000000 |
G | 3 | 1/16" | 1/16" | Barbed | 2.2 | 0.04 | 0-125 | 20 | 5/8" | 3/8" | 1 5/8" | 3/8" | Yes | 00000000 | 00000 |
Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way and 5/2 valves.
Valves with spring return actuation return to their original position as soon as you release the actuator.
Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
O'all | For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Dia. | Mounting Fasteners Included | Each | ||
Threaded Female Inlet × Threaded Female Outlet | |||||||||||||||
Spring Return Actuation | |||||||||||||||
H | 5 | 10-32 UNF | 10-32 UNF | Threaded | 15.3 | 0.23 | 0-125 | Not Rated | 3/4" | 11/16" | 2 7/8" | 1/2" | Yes | 00000000 | 000000 |
Hand Return Actuation | |||||||||||||||
F | 5 | 1/8 NPT | 1/8 NPT | None (To Atmosphere) | 10.5 | 0.186 | 0-150 | 28 | 1 1/4" | 5/8" | 2 3/4" | 1/2" | Yes | 00000000 | 00000 |
F | 5 | 10-32 UNF | 10-32 UNF | None (To Atmosphere) | 10 | 0.177 | 0-150 | 28 | 7/8" | 5/8" | 2 3/4" | 1/2" | Yes | 00000000 | 00000 |
G | 5 | 1/8 NPT | 1/8 NPT | Threaded | 14 | 0.24 | 25-125 | Not Rated | 1 1/4" | 3/4" | 3 3/4" | 1/2" | No | 00000000 | 000000 |
H | 5 | 10-32 UNF | 10-32 UNF | Threaded | 15.3 | 0.23 | 0-125 | Not Rated | 3/4" | 11/16" | 2 7/8" | 1/2" | Yes | 00000000 | 00000 |
J | 5 | 1/8 NPT | 1/8 NPT | Threaded | 16 | 0.37 | 0-125 | Not Rated | 1 1/4" | 5/8" | 2 7/8" | 1/2" | Yes | 00000000 | 00000 |
In the off position, these valves exhaust all air pressure, allowing the equipment to return to the neutral position. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way and 5/3 exhaust center valves.
Valves with hand return actuation stay actuated and go back to their original position only when you move the actuator again.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | For Panel Cutout Dia. | Mounting Fasteners Included | Each | ||
Threaded Female Inlet × Threaded Female Outlet | |||||||||||||||
Hand Return Actuation | |||||||||||||||
A | 5 | 1/8 NPT | 1/8 NPT | None (To Atmosphere) | 7.5 | 0.133 | 0-150 | Not Rated | 7/8" | 5/8" | 2 1/2" | 5/8" | Yes | 00000000 | 000000 |
A | 5 | 10-32 UNF | 10-32 UNF | None (To Atmosphere) | 7.5 | 0.133 | 0-150 | Not Rated | 7/8" | 5/8" | 2 1/2" | 5/8" | Yes | 00000000 | 00000 |
Open and close these valves with the flip of the toggle switch. Commonly used for equipment testing and gas sampling, they have threads and a hex nut below the handle for installation in instrument panels.
316 stainless steel valves are more corrosion resistant than brass valves.
Manual-return valves remain open or closed when the toggle is moved into position.
Spring-return valves automatically close when the toggle is released.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Toggle Switch Type | End-to-End Lg. | Panel Cutout Dia. | Each | |
Brass Body—Fluoroelastomer Rubber Seal | ||||||||
---|---|---|---|---|---|---|---|---|
NPTF Female × NPTF Female | ||||||||
1/8 | 0.3 | 200 psi @ 70° F | -15° to 250° | Manual Return | 1 7/16" | 9/16" | 0000000 | 000000 |
1/4 | 1.2 | 125 psi @ 70° F | -15° to 250° | Manual Return | 1 7/8" | 9/16" | 0000000 | 00000 |
Brass Body—PTFE Plastic Seal | ||||||||
NPT Male × NPT Male | ||||||||
1/8 | 0.1 | 300 psi @ 200° F | -20° to 200° | Manual Return | 1 15/16" | 17/32" | 0000000 | 00000 |
1/4 | 0.2 | 300 psi @ 200° F | -20° to 200° | Manual Return | 2 1/4" | 17/32" | 0000000 | 00000 |
316 Stainless Steel Body—PTFE Plastic Seal | ||||||||
NPT Male × NPT Male | ||||||||
1/8 | 0.1 | 300 psi @ 200° F | -20° to 200° | Manual Return | 1 15/16" | 17/32" | 0000000 | 00000 |
1/4 | 0.2 | 300 psi @ 200° F | -20° to 200° | Manual Return | 2 1/4" | 17/32" | 0000000 | 00000 |
Pipe Size | Thread Size | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Toggle Switch Type | Port-to-Port Lg. | Panel Cutout Dia. | Each | |
Brass Body—Buna-N Rubber Seal | |||||||||
---|---|---|---|---|---|---|---|---|---|
NPT Male × UNF Female | |||||||||
1/8 | 10-32 | 7.3 | 150 psi @ 70° F | 35° to 230° | Manual Return | 5/16" | 15/32" | 0000000 | 000000 |
1/8 | 10-32 | 8 | 150 psi @ 70° F | 35° to 230° | Manual Return | 5/16" | 15/32" | 0000000 | 00000 |
1/8 | 10-32 | 8 | 150 psi @ 70° F | 35° to 230° | Spring Return | 5/16" | 15/32" | 0000000 | 00000 |
UNF Female × UNF Female | |||||||||
__ | 10-32 | 6.8 | 150 psi @ 70° F | 35° to 230° | Spring Return | 5/16" | 15/32" | 0000000 | 00000 |
__ | 10-32 | 7.3 | 150 psi @ 70° F | 35° to 230° | Manual Return | 5/16" | 15/32" | 0000000 | 00000 |
Brass Body—Fluoroelastomer Rubber Seal | |||||||||
NPTF Female × NPTF Female | |||||||||
1/8 | __ | 0.3 | 200 psi @ 70° F | -15° to 250° | Manual Return | 3/4" | 9/16" | 0000000 | 00000 |
1/4 | __ | 1.2 | 125 psi @ 70° F | -15° to 250° | Manual Return | 3/4" | 9/16" | 0000000 | 00000 |
Brass Body—PTFE Plastic Seal | |||||||||
NPT Male × NPT Male | |||||||||
1/4 | __ | 0.2 | 300 psi @ 200° F | -20° to 200° | Manual Return | 1" | 17/32" | 0000000 | 00000 |
316 Stainless Steel Body—PTFE Plastic Seal | |||||||||
NPT Male × NPT Male | |||||||||
1/4 | __ | 0.2 | 300 psi @ 200° F | -20° to 200° | Manual Return | 1" | 17/32" | 0000000 | 00000 |
Flip the toggle to quickly turn these valves on and off. All have threads and a hex nut below the handle for installation in instrument panels. For extra gripping power and a strong seal, they have Yor-Lok fittings with two sleeves that bite into tubing as you tighten the nut. All are compatible with Swagelok®, Let-Lok, and Parker A-Lok fittings.
316 stainless steel valves are more corrosion resistant than brass valves.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Straight | 90° Elbow | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Panel Cutout Dia. | End-to-End Lg. | Each | Port-to-Port Lg. | Each | ||
Brass Body | ||||||||||
Yor Lok × Yor Lok | ||||||||||
1/8" | 0.1 | 300 psi @ 200° F | -20° to 200° | 17/32" | 1 15/16" | 0000000 | 000000 | __ | 000000 | 00 |
1/4" | 0.2 | 300 psi @ 200° F | -20° to 200° | 17/32" | 2 1/4" | 0000000 | 00000 | 1 1/8" | 0000000 | 000000 |
316 Stainless Steel Body | ||||||||||
Yor Lok × Yor Lok | ||||||||||
1/8" | 0.1 | 300 psi @ 200° F | -20° to 200° | 17/32" | 1 15/16" | 0000000 | 00000 | __ | 000000 | 00 |
1/4" | 0.2 | 300 psi @ 200° F | -20° to 200° | 17/32" | 2 1/4" | 0000000 | 00000 | 1 1/8" | 0000000 | 00000 |
Also known as vacuum isolation valves, these block flow so you can install and remove gauges from your system. They can also be used to add or vent gases in high-vacuum systems. Valves gradually open and close with multiple turns of the wheel handle to prevent system damage from suddenly starting and stopping flow. They connect to another quick-clamp fitting with a clamp and a ring (sold separately). All have a nonrising stem that stays in the same position whether the valve is open or closed. Body is 304 stainless steel for good corrosion resistance.
For technical drawings and 3-D models, click on a part number.
O'all | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | Flange OD | Max. Vacuum | Temp. Range, °F | Ht. | Lg. | Trade Number | Sterilize With | Stem Type | Each | |
Quick Clamp | ||||||||||
304 Stainless Steel Body—316 Stainless Steel Gate | ||||||||||
1/2" | 1 3/16" | 10 -7 torr @ 72° F | 0° to 190° | 4 1/8" | 2 1/4" | 10 | Steam (Autoclaving) | Nonrising | 00000000 | 0000000 |
3/4" | 1 3/16" | 10 -7 torr @ 72° F | 0° to 190° | 4 1/8" | 2 1/4" | 16 | Steam (Autoclaving) | Nonrising | 00000000 | 000000 |
1" | 1 9/16" | 10 -7 torr @ 72° F | 0° to 190° | 5 5/8" | 3" | 25 | Steam (Autoclaving) | Nonrising | 00000000 | 000000 |
1 1/2" | 2 1/8" | 10 -7 torr @ 72° F | 0° to 190° | 6 3/8" | 3 7/8" | 40 | Steam (Autoclaving) | Nonrising | 00000000 | 000000 |
2" | 2 15/16" | 10 -7 torr @ 72° F | 0° to 190° | 8" | 4 1/2" | 50 | Steam (Autoclaving) | Nonrising | 00000000 | 000000 |
Use these rings with quick-clamp high-vacuum fittings. They consist of a stainless steel inner ring covered by a fluoroelastomer O-ring.
Rings with screen have a stainless steel screen to filter out large particles.
Pressure-rated rings have an aluminum outer ring to withstand extra pressure.
For Tube OD | For Flange OD | Trade Number | Max. Vacuum | Temp. Range, °F | Lg. | Each | |
Rings | |||||||
---|---|---|---|---|---|---|---|
1/2" | 1.18" | 10 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 00000000 | 00000 |
3/4" | 1.18" | 16 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 00000000 | 0000 |
1" | 1.57" | 25 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 0000000 | 0000 |
1 1/2" | 2.16" | 40 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 0000000 | 00000 |
2" | 2.95" | 50 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 0000000 | 00000 |
Rings with Screen | |||||||
3/4" | 1.18" | 16 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 00000000 | 00000 |
1" | 1.57" | 25 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 00000000 | 00000 |
1 1/2" | 2.16" | 40 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 00000000 | 00000 |
2" | 2.95" | 50 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 00000000 | 00000 |
Pressure-Rated Rings | |||||||
1" | 1.57" | 25 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 0000000 | 00000 |
1 1/2" | 2.16" | 40 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 0000000 | 00000 |
2" | 2.95" | 50 | 10 -7 torr @ 72° F | 0° to 300° | 5/16" | 0000000 | 00000 |