IEC Style IEC Style | Show |
---|
![]() | C14 |
Number of Blades Number of Blades |
---|
![]() | 3 |
Current Current |
---|
Connection Type Connection Type |
---|
|
|
End Shape End Shape |
---|
![]() | Straight |
Specifications Met Specifications Met |
---|
|
Number of Slots Number of Slots |
---|
![]() | 3 |
Color Color |
---|
![]() | Black |
Application Application |
---|
|
Shielding Shielding |
---|
![]() | Unshielded |
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Flexibility Flexibility |
---|
![]() | ![]() |
Ultra Flexible | Flexible |
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Industry Designation for Cable Insulation
More
Electronic Equipment Power Cords



Use these cords with computers, lab equipment, and office machines that have IEC connections.
Use SJT cords in dry or damp environments.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
IEC C14 Plug × IEC C13 Socket | |||||||||||
18 | 10 | 125V AC | 1 1/2 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 00000 |
18 | 10 | 125V AC | 3 | 0.31" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 0000 |
17 | 10 | 250V AC | 6 1/2 | 0.28" | PVC Plastic | __ | 35° to 165° | IEC 60320 | Black | 00000000 | 00000 |
Locking Electronic Equipment Power Cords



Create a vibration-resistant connection—the socket on these cords securely locks onto any male receptacle and will not detach until manually unlocked. Use them with computers, lab equipment, and office machines that have IEC connections.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
IEC C14 Plug × IEC C13 Socket | |||||||||||
18 | 10 | 250V AC | 6 | 0.11" | PVC Plastic | SJT | -40° to 140° | UL Listed, C-UL Listed, IEC 60320 | Black | 000000 | 000000 |
Electronic Equipment Cord Splitters
Power multiple devices from one power source. Use these splitters with computers, lab equipment, and office machines that have IEC connections.
Use SJT cords in dry or damp locations.
SVT cords are ultra-flexible and as pliable as vacuum cleaner cords. They withstand repeated winding.



Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
18 | 10 | 250V AC | 6 | 0.11" | PVC Plastic | SJT | -40° to 220° | UL Recognized Component, C-UL Recognized Component, IEC 60320 | Black | 000000 | 000000 |
18 | 10 | 250V AC | 6 | 0.11" | PVC Plastic | SVT | -40° to 220° | UL Recognized Component, C-UL Recognized Component, IEC 60320 | Black | 000000 | 00000 |
Light Duty Power Cords


Designed for indoor applications, these cords are often used to power appliances.
Use SJT cords in dry or damp locations.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Gauge | Current, A | Voltage | Lg., ft. | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Color | Each | |
IEC C14 Plug × Wire Leads | |||||||||||
18 | 10 | 250V AC | 6 1/2 | 0.33" | PVC Plastic | SJT | 0° to 140° | UL Listed, CSA Certified, IEC 60320 | Black | 00000000 | 000000 |
Detachable-Cord AC to DC Adapters








Couple these adapters with a cord that matches your outlet and length requirements to run DC-powered electronics. Instead of plugging directly into an outlet, the body of these adapters sits on the floor or other surface, so it remains out of the way and won’t block multiple outlets. These adapters use switching regulation—they produce the stated voltage even when your outlet’s power or the power drawn by your device fluctuates. Most have an LPS low-voltage output, so if something fails inside these adapters, they’ll limit the risk of electrical shocks. They meet U.S., Canadian, and European safety standards. Many also meet U.S. and European standards for energy efficiency.
When choosing an adapter, match the output voltage and polarity of your device. Look for the polarity illustration on your device or the adapter you're replacing. The current you choose should, at a minimum, match your device. You can choose a higher current, but it will not improve performance.
Adapters with an IEC C14 input require power cords with a C13 socket. They have Class I shock protection and prevent electrical shocks with a combination of insulation and a protective ground.
Barrel/Pin Output Connection | Straight-Blade Input Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Polarity | End ID, mm | End OD, mm | End Shape | Voltage | Current, A | End Shape | Lg., ft. | Shock Protection Class | Protections Provided | Color | Each | |
IEC C14 Input × Barrel Output | ||||||||||||||
5V DC | 3 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
5V DC | 5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
9V DC | 2.2 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
9V DC | 3.3 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
12V DC | 1.6 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
12V DC | 3 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
12V DC | 5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
12V DC | 7 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
15V DC | 1.3 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
18V DC | 1.1 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
18V DC | 2 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
18V DC | 3.6 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
18V DC | 5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 0.8 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 1.5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 2.7 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 3.8 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
48V DC | 0.5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.6 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
48V DC | 0.8 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 0000000 | 00000 |
48V DC | 1.4 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 0000000 | 00000 |
48V DC | 1.9 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 0000000 | 00000 |
56V DC | 1.2 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
56V DC | 1.6 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
IEC C14 Input × 4-Pin Circular DIN Output | ||||||||||||||
12V DC | 12.5 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
12V DC | 16 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.8 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
24V DC | 6.6 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 8.3 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.8 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
48V DC | 3.3 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
48V DC | 4.2 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.8 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
IEC C14 Input × 6-Pin Molex Mini-Fit Output | ||||||||||||||
12V DC | 20 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.3 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
12V DC | 24 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.9 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
24V DC | 10.4 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.3 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
24V DC | 12.5 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.9 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
48V DC | 5.2 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.3 | Straight | 4 | I | Overcurrent, Overvoltage, Short Circuit | Black | 0000000 | 000000 |
48V DC | 6.3 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.9 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
Medical-Grade AC to DC Adapters








To run DC-powered lab and medical equipment from your outlet, add a power cord with the plug style and length you need. These adapters meet strict IEC, UL, or ANSI/AAMI standards for use with medical devices. They also have a Means of Protection rating of 2xMOPP, which is the highest level of shock protection available for medical-grade power supplies, so in addition to using them with lab and medical equipment, you can use them with devices that come into contact with patients.
Unlike adapters with bodies that plug directly into an outlet, the body of these adapters rests on a desk or the floor, so it won’t block multiple outlets. Those with an IEC C14 input connection require power cords with a C13 socket.
When selecting an adapter, make sure the DC voltage and amps for the pin output connection can handle the requirements of your device. Choosing a DC voltage and amps that are much higher than you need will not improve performance.
These adapters use switching regulation, which means they produce the stated voltage despite fluctuations in your outlet’s power and the power being drawn by your device. It also means they won’t get too hot.
If you exceed the maximum voltage or load, these adapters shut down to protect both the adapters and the connected equipment.
All of these adapters meet European safety standards. Those with Class I shock protection prevent electrical shocks with a combination of insulation and a protective ground.
Barrel/Pin Output Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Polarity | End Shape | Voltage | Current, A | End Shape | Lg., ft. | Shock Protection Class | Protections Provided | Specifications Met | Color | Each | |
Nondetachable-Cord | |||||||||||||
IEC C14 Input × 4-Pin Output | |||||||||||||
12V DC | 13.3 | Positive | Straight | 120V AC, 240V AC | 2.5 | Straight | 3.44 | I | Overvoltage, Short Circuit | CE Marked, UL60601-1, EN60601-1, IEC60601-1 | Black | 0000000 | 0000000 |
24V DC | 2.7 | Positive | Straight | 120V AC, 240V AC | 2 | Straight | 3.4 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, ANSI/AAMI ES60601-1, UL/CSA/IEC/EN 60601-1 | Black | 0000000 | 00000 |
24V DC | 6.9 | Positive | Straight | 120V AC, 240V AC | 2.5 | Straight | 3.44 | I | Overvoltage, Short Circuit | CE Marked, UL60601-1, EN60601-1, IEC60601-1 | Black | 0000000 | 000000 |
48V DC | 3.4 | Positive | Straight | 120V AC, 240V AC | 2.5 | Straight | 3.44 | I | Overvoltage, Short Circuit | CE Marked, UL60601-1, EN60601-1, IEC60601-1 | Black | 0000000 | 000000 |
IEC C14 Input × 6-Pin Output | |||||||||||||
12V DC | 20.8 | Positive | Straight | 120V AC, 240V AC | 1.3 | Straight | 2.62 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, 60950-1, IEC/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1 | Black | 0000000 | 000000 |
24V DC | 10.4 | Positive | Straight | 120V AC, 240V AC | 1.3 | Straight | 2.62 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, 60950-1, IEC/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1 | Black | 0000000 | 000000 |
48V DC | 5.2 | Positive | Straight | 120V AC, 240V AC | 1.3 | Straight | 2.62 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, 60950-1, IEC/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1 | Black | 0000000 | 000000 |
IEC C14 Input × 10-Pin Output | |||||||||||||
12V DC | 25 | Positive | Straight | 120V AC, 240V AC | 3 | Straight | 2.62 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, 60950-1, IEC/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1, IEC60601-1-11 | Black | 0000000 | 000000 |
24V DC | 12.5 | Positive | Straight | 120V AC, 240V AC | 3 | Straight | 2.62 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, 60950-1, IEC/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1, IEC60601-1-11 | Black | 0000000 | 000000 |
48V DC | 3.3 | Positive | Straight | 120V AC, 240V AC | 3 | Straight | 2.62 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, 60950-1, IEC/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1, IEC60601-1-11 | Black | 0000000 | 000000 |