Voltage Voltage | Show |
---|
|
Voltage Voltage | Hide |
---|
Current Current |
---|
|
Wire Type Wire Type |
---|
![]() | |
Outer Insulation Color Outer Insulation Color |
---|
![]() | Black |
Shielding Shielding |
---|
![]() | Unshielded |
![]() | Double Shielded |
Use For Use For |
---|
|
System of Measurement System of Measurement |
---|
|
Wire Finish Wire Finish |
---|
|
Flexibility Flexibility |
---|
![]() | Flexible |
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Wire Material Wire Material |
---|
|
Specifications Met Specifications Met |
---|
|
Outer Insulation Material Outer Insulation Material |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
About Wire and Cable
More
Motor Cable
This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
Cable with power and signal wires has an individually shielded pair of wires that connect to a brake or temperature sensor, reducing the number of cables used in areas with limited space.

- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Insulation: Polyethylene Plastic
Power Wire | Signal Wire | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | No. of | Ga. | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Specifications Met | 5 ft. | 10 ft. | 20 ft. | 30 ft. | 50 ft. | |
Double Shielded—1,000V AC/1,000V DC | |||||||||||||||||
4 | 16 | 16/4 | 2 | 18 | 18/2 | 18 A @ 86° F | 0.57" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 00000000 | |||||
4 | 14 | 14/4 | 2 | 14 | 14/2 | 25 A @ 86° F | 0.63" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 14 | 14/4 | 2 | 18 | 18/2 | 25 A @ 86° F | 0.62" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 12 | 12/4 | 2 | 14 | 14/2 | 30 A @ 86° F | 0.67" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 12 | 12/4 | 2 | 18 | 18/2 | 30 A @ 86° F | 0.65" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 10 | 10/4 | 2 | 14 | 14/2 | 40 A @ 86° F | 0.74" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 8 | 8/4 | 2 | 18 | 18/2 | 55 A @ 86° F | 0.96" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | |||||
4 | 6 | 6/4 | 2 | 14 | 14/2 | 75 A @ 86° F | 1.03" | Black | Black, Green/Yellow | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 |
Building Wire
- Use for buildings
- Stranded Wire: Flexible
Solid Wire: Bend and Stay - Temperature Range:
Wire with Nylon Outer Insulation: -10° to 190° F
Wire with Polyethylene Outer Insulation: -40° to 190° F
Install this wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire.
Stranded wire is flexible, so it’s pliable enough to be pulled around corners. Wire with a polyethylene outer insulation resists abrasion and chemicals. It’s more flexible than nylon insulated wire.
XHHW-2 wire is for dry and wet locations where wire may be exposed to dripping or splashing liquid. Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.