Clear All
Wire Application Wire Application |
|---|
|
Current Current |
|---|
|
|
Voltage Voltage | Show |
|---|
|
Voltage Voltage | Hide |
|---|
System of Measurement System of Measurement |
|---|
|
Shielding Shielding |
|---|
| Double Shielded | |
Use For Use For |
|---|
|
Inner Insulation Material Inner Insulation Material |
|---|
|
Outer Insulation Color Outer Insulation Color |
|---|
| Black | |
Wire Type Wire Type |
|---|
Outer Insulation Material Outer Insulation Material |
|---|
|
Inner Insulation Marking Inner Insulation Marking |
|---|
|
Maximum Temperature Maximum Temperature |
|---|
|
Inner Insulation Color Inner Insulation Color |
|---|
| Black | |
| Green/Yellow |
Specifications Met Specifications Met |
|---|
|
Flexibility Flexibility |
|---|
![]() | Flexible |
Wire Material Wire Material |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
About Wire and Cable
More
Motor Cable
This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
Cable with power wires sends electricity to run a motor.
MSHA approved cable meets Mine Safety and Health Administration (MSHA) standards for material quality.
Power Wire—Stranded
Power
- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Insulation:
Outer: PVC Plastic
Inner: Nylon Plastic/PVC Plastic
Power Wire | Per Ft. | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of | Ga. | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double Shielded—1,000V AC/1,500V DC | |||||||||||||
| 4 | 18 | 18/4 | 7 A @ 86° F | 0.39" | Black | Black, Green/Yellow | __ | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
| 4 | 16 | 16/4 | 10 A @ 86° F | 0.46" | Black | Black, Green/Yellow | Uninsulated Ground Wire | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
| 4 | 14 | 14/4 | 15 A @ 86° F | 0.52" | Black | Black, Green/Yellow | __ | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
| 4 | 12 | 12/4 | 20 A @ 86° F | 0.58" | Black | Black, Green/Yellow | __ | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
| 4 | 10 | 10/4 | 30 A @ 86° F | 0.7" | Black | Black, Green/Yellow | __ | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 0000 | 0000 | |
| 4 | 8 | 8/4 | 40 A @ 86° F | 0.84" | Black | Black, Green/Yellow | __ | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 00000 | 00000 | |
| 4 | 6 | 6/4 | 55 A @ 86° F | 1" | Black | Black, Green/Yellow | __ | WTTC | UL Listed, C-UL Listed, Flame Rated FT4 | 0000000 | 00000 | 00000 | |