Often used in mining equipment, submersible pumps, and drilling rigs, this cable withstands 2,000 volts AC/DC. It meets Mine Safety and Health Administration (MSHA) standards for material quality. The EPDM insulation resists abrasion, so it can be pulled over rough surfaces without damaging the wires inside.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | |
Stranded Wire | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
2,000V AC/2,000V DC | ||||||||||||
8 | 2 | 8/2 | 74 A @ 86° F | 0.78" | Black | Black, White | UL Listed, CSA Certified, MSHA Approved | 000000 | ||||
8 | 3 | 8/3 | 74 A @ 86° F | 0.92" | Black | Black, Green, White | UL Listed, CSA Certified, MSHA Approved | 000000 | ||||
6 | 2 | 6/2 | 99 A @ 86° F | 0.91" | Black | Black, White | UL Listed, CSA Certified, MSHA Approved | 000000 | ||||
6 | 3 | 6/3 | 99 A @ 86° F | 0.99" | Black | Black, Green, White | UL Listed, CSA Certified, MSHA Approved | 000000 | ||||
4 | 3 | 4/3 | 130 A @ 86° F | 1.13" | Black | Black, Green, White | UL Listed, CSA Certified, MSHA Approved | 000000 | ||||
2 | 2 | 2/2 | 174 A @ 86° F | 1.22" | Black | Black, White | UL Listed, CSA Certified, MSHA Approved | 000000 | ||||
2 | 3 | 2/3 | 174 A @ 86° F | 1.28" | Black | Black, Green, White | UL Listed, CSA Certified, MSHA Approved | 000000 |
Also known as photovoltaic (PV) wire, this wire is often used in solar panels and withstands 2,000 volts AC/DC. The industry designation is RHW-2, so it can be used underground and in wet locations. Made of polyethylene, the insulation resists abrasion and chemicals.
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | 10 ft. | 25 ft. | 50 ft. | 100 ft. | |
Stranded Wire | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
2,000V AC/DC | ||||||||||
12 | 40 A @ 86° F | 0.24" | PV, RHW-2 | UL Listed, C-UL Listed | 000000 | |||||
10 | 40 A @ 86° F | 0.26" | PV, RHW-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 000000 | |||||