Plug these adapter cords into a standard outlet and they change AC voltage to DC voltage, so you can power many electronic devices.
When selecting a cord, make sure the DC voltage and amps for the barrel output connection can handle the requirements of your device. Choosing a DC voltage and amps that are much higher than you need will not improve performance.
Next, the polarity of the adapter cord and your device must be the same. Look for the polarity illustration on your device or the adapter cord you’re replacing and pick a cord to match.
All of these cords use switching regulation, which means they produce the stated voltage despite fluctuations in your outlet’s power and the power being drawn by your device. It also means they won’t get too hot.
With an LPS low-voltage output, if something fails inside these cords, they’ll limit the risk of electrical shocks. Class II shock protection means they have two levels of insulation, which also prevents electrical shocks. All have passed strict U.S. and Canadian safety standards.
These cords meet U.S. DOE (Department of Energy) Level VI standards for energy efficiency when they're in-use, as well as when they're plugged in but not in use.
Barrel Output Connection | Straight-Blade Input Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | End ID, mm | End OD, mm | End Shape | Voltage | Current, A | NEMA Style | End Shape | Lg., ft. | Protections Provided | Color | Each | |
Negative Polarity | |||||||||||||
24V DC | 0.5 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.4 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 00000000 | 000000 |
24V DC | 0.5 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.4 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 0.75 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 0.75 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 1 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 1 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 1.5 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 1.5 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 1 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
Positive Polarity | |||||||||||||
24V DC | 0.5 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.4 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 0.5 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.4 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 0.75 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 0.75 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 1 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 1 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 1.5 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
24V DC | 1.5 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 1 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | Black | 000000000 | 00000 |
Pair these adapters with power cords that have the plug style and cord length you need to run DC-powered devices from your outlet. Unlike adapters with bodies that plug directly into an outlet, the body of these adapters rests on a desk or the floor, so it won’t block multiple outlets.
When selecting an adapter, make sure the DC voltage and amps for the barrel or pin output connection can handle the requirements of your device. Choosing a DC voltage and amps that are much higher than you need will not improve performance. For adapters with a barrel output connection, the polarity of your power cord and your device must be the same. Look for the polarity illustration on your device or the adapter you’re replacing and make sure your power cord matches it.
Adapters with an IEC C8 input connection require power cords with a C7 socket. Those with an IEC C14 input connection require power cords with a C13 socket.
These adapters use switching regulation, which means they produce the stated voltage despite fluctuations in your outlet’s power and the power being drawn by your device. It also means they won’t get too hot.
If something fails inside the adapters, the LPS low-voltage output on most adapters will limit the risk of electrical shocks. Adapters with Class II shock protection have two levels of insulation that also prevent electrical shocks. Those with Class I shock protection prevent electrical shocks with a combination of insulation and a protective ground. All have passed strict U.S., Canadian, and European Union safety standards.
All of these adapters meet U.S. DOE (Department of Energy) Level VI standards for energy efficiency when they're in-use, as well as when they're plugged in but not in use. Many also meet EU CoC (European Union Code of Conduct) Tier 2 energy efficiency standards for the same uses.
Barrel/Pin Output Connection | Straight-Blade Input Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Polarity | End ID, mm | End OD, mm | End Shape | Voltage | Current, A | End Shape | Lg., ft. | Shock Protection Class | Protections Provided | Color | Each | |
IEC C8 Input × Barrel Output | ||||||||||||||
24V DC | 0.8 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | Straight | 5 | II | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
24V DC | 1.5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | II | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 2.7 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | II | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
IEC C14 Input × Barrel Output | ||||||||||||||
24V DC | 0.8 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.5 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 1.5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 2.7 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 3.8 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
IEC C14 Input × 4-Pin Output | ||||||||||||||
24V DC | 6.6 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 8.3 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.8 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
IEC C14 Input × 6-Pin Output | ||||||||||||||
24V DC | 10.4 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.3 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
24V DC | 12.5 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.9 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
To run DC-powered lab and medical equipment from your outlet, add a power cord with the plug style and length you need. These adapters meet strict IEC and ANSI/AAMI (Association for the Advancement of Medical Instrumentation) standards for use with medical devices. They also have a Means of Protection rating of 2xMOPP, which is the highest level of shock protection available for medical-grade power supplies, so in addition to using them with lab and medical equipment, you can use them with devices that come into contact with patients.
Unlike adapters with bodies that plug directly into an outlet, the body of these adapters rests on a desk or the floor, so it won’t block multiple outlets. Adapters with an IEC C8 input connection require power cords with a C7 socket. Those with an IEC C14 input connection require power cords with a C13 socket.
When selecting an adapter, make sure the DC voltage and amps for the barrel or pin output connection can handle the requirements of your device. Choosing a DC voltage and amps that are much higher than you need will not improve performance. For adapters with a barrel output connection, the polarity of your power cord and your device must be the same. Look for the polarity illustration on your device or the adapter you’re replacing and make sure your power cord matches it.
These adapters use switching regulation, which means they produce the stated voltage despite fluctuations in your outlet’s power and the power being drawn by your device. It also means they won’t get too hot.
If you exceed the maximum voltage or load, these adapters shut down to protect both the adapters and the connected equipment.
In addition to meeting UL and C-UL safety standards, these adapters also are TUV certified, a European safety standard. Adapters with Class II shock protection have two levels of insulation to prevent electrical shocks. Those with Class I shock protection prevent electrical shocks with a combination of insulation and a protective ground.
All of these adapters meet U.S. DOE (Department of Energy) Level VI standards for energy efficiency when they're in-use, as well as when they're plugged in but not in use. They also meet ErP (European Union) Stage 2 standards for energy efficiency when you are using them.
Barrel/Pin Output Connection | Straight-Blade Input Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Polarity | End ID, mm | End OD, mm | End Shape | Voltage | Current, A | End Shape | Lg., ft. | Shock Protection Class | Protections Provided | Color | Each | |
IEC C8 Input × Barrel Output | ||||||||||||||
24V DC | 1.5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | II | Overload, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
24V DC | 5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | II | Overload, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
IEC C8 Input × 4-Pin Output | ||||||||||||||
24V DC | 2.7 | __ | __ | __ | Straight | 120V AC, 240V AC | 1.6 | Straight | 5 | II | Overload, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
IEC C14 Input × Barrel Output | ||||||||||||||
24V DC | 1.5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | I | Overload, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 3.8 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.2 | Straight | 5 | I | Overload, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | I | Overload, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
IEC C14 Input × 4-Pin Output | ||||||||||||||
24V DC | 2.7 | __ | __ | __ | Straight | 120V AC, 240V AC | 1.6 | Straight | 5 | I | Overload, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 8.3 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.5 | Straight | 5 | I | Overload, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
IEC C14 Input × 6-Pin Output | ||||||||||||||
24V DC | 12.5 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.4 | Straight | 5 | I | Overload, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
There’s no need for multiple adapter cords or converters, simply swap out the input plugs on these cords to match the outlets of the region you’re in. Use these adapter cords to run DC-powered devices from an outlet in a variety of different countries.
When selecting a cord, make sure the DC voltage and amps for the barrel output connection can handle the requirements of your device. Choosing a DC voltage and amps that are much higher than you need will not improve performance.
Next, the polarity of the adapter cord and your device must be the same. Look for the polarity illustration on your device or the adapter cord you’re replacing and pick a cord to match.
All of these cords use switching regulation, which means they produce the stated voltage despite fluctuations in your outlet’s power and the power being drawn by your device. It also means they won’t get too hot.
With an LPS low-voltage output, if something fails inside these cords, they’ll limit the risk of electrical shocks. Class II shock protection means they have two levels of insulation, which also prevents electrical shocks. All have passed strict U.S., Canadian, European Union, Chinese, Australian, and New Zealand safety standards.
These cords meet U.S. DOE (Department of Energy) Level VI standards for energy efficiency when they're in-use, as well as when they're plugged in but not in use.
Barrel Output Connection | Straight-Blade Input Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | End ID, mm | End OD, mm | End Shape | Voltage | Current, A | End Shape | Lg., ft. | Protections Provided | Color | Each | |
Negative Polarity | ||||||||||||
AS 3112, BS 1363, CEE 7/16, × NEMA 1-15 Plugs | ||||||||||||
24V DC | 1 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 90° Elbow | 5 | Overvoltage, Short Circuit | Black | 0000000 | 000000 |
24V DC | 1 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 90° Elbow | 5 | Overvoltage, Short Circuit | Black | 0000000 | 00000 |
Positive Polarity | ||||||||||||
AS 3112, BS 1363, CEE 7/16, × NEMA 1-15 Plugs | ||||||||||||
24V DC | 1 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 90° Elbow | 5 | Overvoltage, Short Circuit | Black | 0000000 | 00000 |
24V DC | 1 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 90° Elbow | 5 | Overvoltage, Short Circuit | Black | 0000000 | 00000 |
Use these cords with hydraulic and air-powered valves, motors, pumps, and pressure switches. They have a solenoid valve socket on one end and an M12 threaded plug on the other. The ground connection is not included in the number of poles. A power-indicating light on the socket illuminates when the cord has power. All are IP-rated for protection from washdowns and temporary submersion.
Socket | Plug | Cord | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Solenoid Connection Type | Contact Distance | Housing Thread Size | Coding | No. of Poles | No. of Ground Connections | Lg., ft. | Wire Gauge | Current, A | Voltage | OD | Insulation Material | Specifications Met | Each | |
90° Elbow Socket × Plug (External Thread) | ||||||||||||||
NEMA Industrial Standard BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | CSA Certified, CSA-US Certified | 0000000 | 000000 |
NEMA Industrial Standard BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | CSA Certified, CSA-US Certified | 0000000 | 00000 |
NEMA Industrial Standard CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | CSA Certified, CSA-US Certified | 0000000 | 00000 |
NEMA Industrial Standard CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | CSA Certified, CSA-US Certified | 0000000 | 00000 |
DIN Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | CSA Certified, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
DIN Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | CSA Certified, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
DIN Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | CSA Certified, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
DIN Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | CSA Certified, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Connect multiple devices to these distribution blocks to create a network between equipment. They’re rated IP67 for protection from washdowns and temporary submersion.
Socket | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal Output Type | Housing Thread Size | No. of Outlets | No. of Poles | No. of Keyways | Coding | Face Dia. | Cord Lg., ft. | Current, A | Voltage | Wire Gauge | Cord OD | Specifications Met | Temp. Range, °F | Color | Each | |
Socket (Internal Thread) with Wire Leads | ||||||||||||||||
PNP | M8 | 4 | 3 | 0 | __ | 0.2" | 16 | 2 | 24V DC | 22 | 0.27" | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M8 | 4 | 3 | 0 | __ | 0.2" | 32 | 2 | 24V DC | 22 | 0.27" | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M8 | 8 | 3 | 0 | __ | 0.2" | 16 | 2 | 24V DC | 22 | 0.34" | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M8 | 8 | 3 | 0 | __ | 0.2" | 32 | 2 | 24V DC | 22 | 0.34" | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M12 | 4 | 4 | 1 | A | 0.3" | 16 | 4 | 24V DC | 22 | 0.33" | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 00000 |
PNP | M12 | 4 | 4 | 1 | A | 0.3" | 32 | 4 | 24V DC | 22 | 0.33" | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 8 | 4 | 1 | A | 0.3" | 16 | 4 | 24V DC | 22 | 0.36" | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 8 | 4 | 1 | A | 0.3" | 32 | 4 | 24V DC | 22 | 0.36" | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
Change the M8 8-pin connection on your Schunk gripper to wire leads for hardwiring robots that don’t have an M8 8-pin connection.
For technical drawings and 3-D models, click on a part number.
Housing | |||||||||
---|---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Keyways | Number of Wire Leads | Voltage | Color | Cable Lead Lg., m | Thread Size | Thread Type | Each | |
Sockets with Wire Leads—Internal Thread | |||||||||
8 | 0 | 3 | 24V DC | Black | 5 | M8 × 1 mm | Metric | 00000000 | 0000000 |