System of Measurement System of Measurement |
---|
|
Voltage Voltage | Show |
---|
|
Voltage Voltage | Hide |
---|
Outer Insulation Color Outer Insulation Color |
---|
![]() | Black |
![]() | Yellow |
![]() | Orange |
![]() | Gray |
![]() | White |
![]() | Red |
![]() | Brown |
![]() | Green |
![]() | Blue |
![]() | Green/Yellow |
![]() | Beige |
Flexibility Flexibility |
---|
![]() | ![]() |
Ultra Flexible | Flexible |
![]() | |
Bend and Stay |
Wire Material Wire Material |
---|
|
Current Current |
---|
|
Shielding Shielding |
---|
![]() | Unshielded |
Outer Insulation Material Outer Insulation Material |
---|
|
Wire Finish Wire Finish |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
OD OD |
---|
Specifications Met Specifications Met |
---|
|
Inner Insulation Material Inner Insulation Material |
---|
|
Connection Type Connection Type |
---|
![]() | Pin |
More
The insulation on these cords resists abrasion, oil, and welding slag. They're rated NEMA 6P and IP67 to resist corrosion, and withstand washdowns and temporary submersion. Often used with 18 mm and 30 mm proximity sensors and limit switches, they carry higher currents than nano or micro cords.
Use adapters (sold separately) to join connections that both have internal thread.
Caps (sold separately) protect connections when not in use.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Poles | No. of Keyways | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Max. Temp., °F | Specifications Met | Color | Each | |
Plug (Internal Thread) × Socket (Internal Thread) | ||||||||||||||
2 | 1 | 0.55" | 6 | 13 | 600V AC/600V DC | 7/8"-16 | 16 | 0.37" | Rubber | 190° | UL Recognized, C-UL Recognized | Yellow | 0000000 | 000000 |
3 | 1 | 0.55" | 6 | 13 | 600V AC/600V DC | 7/8"-16 | 16 | 0.39" | Rubber | 190° | UL Recognized, C-UL Recognized | Yellow | 0000000 | 00000 |
4 | 1 | 0.55" | 6 | 10 | 600V AC/600V DC | 7/8"-16 | 16 | 0.42" | Rubber | 190° | UL Recognized, C-UL Recognized | Yellow | 0000000 | 00000 |
5 | 1 | 0.55" | 6 | 8 | 600V AC/600V DC | 7/8"-16 | 16 | 0.5" | Rubber | 190° | UL Recognized, C-UL Recognized | Yellow | 0000000 | 00000 |
6 | 1 | 0.55" | 6 | 8 | 600V AC/600V DC | 7/8"-16 | 16 | 0.53" | Rubber | 190° | UL Recognized, C-UL Recognized | Yellow | 0000000 | 000000 |
7 | 1 | 0.7" | 6 | 8 | 600V AC/600V DC | 1"-16 | 16 | 0.54" | Rubber | 190° | UL Recognized, C-UL Recognized | Yellow | 0000000 | 000000 |
8 | 1 | 0.7" | 6 | 7 | 600V AC/600V DC | 1"-16 | 16 | 0.6" | Rubber | 190° | UL Recognized, C-UL Recognized | Yellow | 0000000 | 000000 |
12 | 1 | 0.8" | 6 | 5 | 600V AC/600V DC | 1 1/8"-16 | 16 | 0.67" | Rubber | 190° | UL Recognized, C-UL Recognized | Yellow | 0000000 | 000000 |
More flexible than standard wire, this wire is often used for internal appliance wiring. Also known as MTW wire, it’s rated UL 1063 for machine tool wiring.
Metric wire is also known as Harmonized European Wire and meets HAR H07V-K for size (mm²), material, and voltage. It can also be used on North American electrical panels and machines.
Wire Ga. | Metric Wire Size, mm² | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 500 ft. | |
Metric Stranded Wire | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC/600V DC | ||||||||||||
16 | 1.5 | 24 A @ 86° F | 0.12" | MTW | UL Recognized, CSA Certified, CE Marked, HAR H07V-K, UL 1063 | 000000 | ||||||
14 | 2.5 | 35 A @ 86° F | 0.15" | MTW | UL Recognized, CSA Certified, CE Marked, HAR H07V-K, UL 1063 | 000000 | ||||||
12 | 4 | 40 A @ 86° F | 0.17" | MTW | UL Recognized, CSA Certified, CE Marked, HAR H07V-K, UL 1063 | 000000 | ||||||
10 | 6 | 55 A @ 86° F | 0.19" | MTW | UL Recognized, CSA Certified, CE Marked, HAR H07V-K, UL 1063 | 000000 |
Protected by heat-resistant insulation, this wire is often used in ovens, furnaces, and other electrical heating equipment.
Wire with a fiberglass outer and mica inner insulation is also known as MG wire. It’s often used to wire equipment in steel mills, iron mills, and glass manufacturing.
Per Ft. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Current | OD | Outer Insulation Color | Industry Designation | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with Fiberglass Fabric Outer and Mica Inner Insulation | |||||||||
600V AC/600V DC | |||||||||
8 | 87 A @ 600° F, 159 A @ 86° F | 0.27" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | |
6 | 133 A @ 600° F, 242 A @ 86° F | 0.31" | Beige | MG | UL Listed, CSA Certified | 0000000 | 0000 | 0000 | |
4 | 167 A @ 600° F, 304 A @ 86° F | 0.37" | Beige | MG | UL Listed, CSA Certified | 0000000 | 00000 | 0000 |
Connect batteries in vehicles and generators.
Strand count is the number of strands followed by the size of the individual strand.
Wire with an EPDM rubber insulation is ultra-flexible for use in applications that require tight turns. The insulation resists abrasion and oil.
Per Ft. | ||||||||
---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Choose an Outer Insulation Color | Length, ft. | 1-99 | 100-Up | |
Stranded Wire with PVC Plastic Insulation | ||||||||
600V AC/600V DC | ||||||||
250 MCM | 2,451/30 | 255 A @ 86° F | 0.84" | Black | 00000000 | 000000 | 000000 | |
350 MCM | 3,458/30 | 310 A @ 86° F | 1.05" | Black | 00000000 | 00000 | 00000 | |
500 MCM | 5,054/30 | 380 A @ 86° F | 1.13" | Black | 00000000 | 00000 | 00000 | |
Stranded Wire with EPDM Rubber Insulation | ||||||||
600V AC/600V DC | ||||||||
6 | 259/30 | 105 A @ 86° F | 0.31" | 0000000 | 0000 | 0000 | ||
4 | 385/30 | 140 A @ 86° F | 0.34" | 0000000 | 0000 | 0000 | ||
2 | 651/30 | 190 A @ 86° F | 0.42" | 0000000 | 0000 | 0000 | ||
1 | 798/30 | 220 A @ 86° F | 0.49" | 0000000 | 0000 | 0000 | ||
1/0 | 1,026/30 | 260 A @ 86° F | 0.54" | 0000000 | 0000 | 0000 | ||
2/0 | 1,254/30 | 300 A @ 86° F | 0.59" | 0000000 | 0000 | 0000 | ||
3/0 | 1,615/30 | 350 A @ 86° F | 0.64" | 0000000 | 0000 | 0000 | ||
4/0 | 2,052/30 | 405 A @ 86° F | 0.72" | 0000000 | 00000 | 0000 |
Install this wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire.
Stranded wire is flexible, so it’s pliable enough to be pulled around corners. Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
Wire with a nylon outer insulation resists oil and water. Wire with a polyethylene outer insulation resists abrasion and chemicals. It’s more flexible than nylon insulated wire.
TFFN wire is also known as fixture wire. It’s for use in dry locations. XHHW-2 wire is for dry and wet locations where wire may be exposed to dripping or splashing liquid. THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement. THWN and THWN-2 wire can be used in both wet and dry environments.
Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
600V AC/600V DC | ||||||||
---|---|---|---|---|---|---|---|---|
18 | 6 A @ 86° F | 0.09" | TFFN | UL Listed | 0000000 | 00000 | ||
16 | 8 A @ 86° F | 0.1" | TFFN | UL Listed | 0000000 | 000 | ||
14 | 15 A @ 86° F | 0.11" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
12 | 20 A @ 86° F | 0.13" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
10 | 30 A @ 86° F | 0.16" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
8 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
6 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
4 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
3 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
2 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 0000 | ||
1/0 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 0000 | ||
2/0 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 0000 |
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Each | |
600V AC/600V DC | |||||||
---|---|---|---|---|---|---|---|
18 | 6 A @ 86° F | 0.09" | TFFN | UL Listed | 0000000 | 000000 | |
16 | 8 A @ 86° F | 0.1" | TFFN | UL Listed | 0000000 | 00000 | |
14 | 15 A @ 86° F | 0.11" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | |
12 | 20 A @ 86° F | 0.13" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | |
10 | 30 A @ 86° F | 0.16" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
8 | 55 A @ 86° F | 0.21" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
6 | 75 A @ 86° F | 0.25" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
4 | 95 A @ 86° F | 0.32" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
3 | 110 A @ 86° F | 0.35" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
2 | 130 A @ 86° F | 0.38" | THHN, THWN-2 | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
1/0 | 170 A @ 86° F | 0.47" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 | |
2/0 | 195 A @ 86° F | 0.52" | THHN, THWN-2 | UL Listed | 0000000 | 00000000 |
Wire Ga. | Current | OD | Outer Insulation Color | Industry Designation | Specifications Met | 25 ft. | 50 ft. | 100 ft. | 250 ft. | 500 ft. | |
600V AC/600V DC | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
14 | 15 A @ 86° F | 0.14" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
12 | 20 A @ 86° F | 0.16" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
10 | 30 A @ 86° F | 0.18" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 | |||||
8 | 55 A @ 86° F | 0.24" | Black | XHHW-2 | UL Listed, CSA Certified | 000000 |
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Per Ft. | |
600V AC/600V DC | ||||||||
---|---|---|---|---|---|---|---|---|
14 | 15 A @ 86° F | 0.1" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | ||
12 | 20 A @ 86° F | 0.12" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 | ||
10 | 30 A @ 86° F | 0.15" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000 |
Wire Ga. | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Each | |
600V AC/600V DC | |||||||
---|---|---|---|---|---|---|---|
14 | 15 A @ 86° F | 0.1" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 | |
12 | 20 A @ 86° F | 0.12" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 00000 | |
10 | 30 A @ 86° F | 0.15" | THHN, THWN | UL Listed, C-UL Listed, Flame Rated VW-1 | 0000000 | 000000 |