Wire Connection Type Wire Connection Type |
|---|
![]() | |
| Screw Terminals | Wire Leads |
| Solder |
Voltage Voltage | Show |
|---|
|
Voltage Voltage | Hide |
|---|
Environment Environment |
|---|
|
|
Housing Connection Type Housing Connection Type |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
Stainless Steel Armored Micro M12 Cords
Step on or roll carts and platform trucks over these M12 cords without crushing them. A protective layer of stainless steel makes these the most crush- and abrasion-resistant M12 cords we offer. It also prevents damage from pests that chew through cords. The stainless steel and PVC outer layer keep moisture from corroding the cord, so they can be used outdoors and near chemicals as well. Despite the stainless steel covering, these cords are still flexible enough to route around equipment. Threaded ends create a tight connection that seals out contaminants and won’t shake loose from the vibration of automated machines.
These cords have a standardized code layout to reduce the chances of accidentally mis-mating them. All are A-coded to send signal and power to AC and DC devices. A-coded cords are often used with sensors, actuators, and motors in automated systems. They also connect devices to IO Link controllers and within fieldbus systems, such as Profibus and DeviceNet.
When mated or capped, these cords meet IP ratings. IP67 cords withstand temporary submersion.
Add caps to protect connectors and maintain their IP ratings when not in use.
Note: Sockets may have extra holes on the face that are not used.
For technical drawings and 3-D models, click on a part number.


| No. of Poles | No. of Keyways | Coding | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | Cord OD | Cord Insulation Material | Cord Outer Insulation Material | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 8 | 1 | A | 0.3" | 6 1/2 | 2 | 60V AC/ 60V DC | M12 | 24 | 0.25" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP67 | UL Listed, C-UL Listed, CE Marked | 0000000 | 0000000 |
| 8 | 1 | A | 0.3" | 16 | 2 | 60V AC/ 60V DC | M12 | 24 | 0.25" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP67 | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
Nano M8 Cords





Also known as pico cords, these cords are often used with low-current 8 mm proximity and photoelectric switches.
Cords with 90° elbow plugs and sockets fit flush against equipment, so they fit in tight spaces.
All are rated IP67 for protection from dust and temporary submersion.
Cord | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Poles | Coding | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | OD | Insulation Material | Color | Shielding | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
| 3 | A | 0.2" | 3 | 4 | 60V AC/75V DC | M8 | 24 | 0.17" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
| 3 | A | 0.2" | 6 1/2 | 4 | 60V AC/75V DC | M8 | 24 | 0.17" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
| 3 | A | 0.2" | 13 | 4 | 60V AC/75V DC | M8 | 24 | 0.17" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
| 4 | A | 0.2" | 3 | 4 | 60V AC/75V DC | M8 | 24 | 0.18" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
| 4 | A | 0.2" | 6 1/2 | 4 | 60V AC/75V DC | M8 | 24 | 0.18" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
| 4 | A | 0.2" | 13 | 4 | 60V AC/75V DC | M8 | 24 | 0.18" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
| 5 | B | 0.2" | 3 | 3 | 60V AC/75V DC | M8 | 24 | 0.2" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
| 5 | B | 0.2" | 6 1/2 | 3 | 60V AC/75V DC | M8 | 24 | 0.2" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
90° Elbow Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
| 3 | A | 0.2" | 13 | 4 | 60V AC/75V DC | M8 | 24 | 0.17" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
| 4 | A | 0.2" | 13 | 4 | 60V AC/75V DC | M8 | 24 | 0.18" | PVC Plastic | Yellow | Unshielded | 0° to 220° | IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
Nano M8 Connectors
Also known as pico connectors, these are for low-current devices such as 8 mm and smaller proximity switches and photoelectric switches.
To view wiring diagrams, select a part number and click Product Detail.
Connectors with screw terminals hold wire by tightening a screw, so you don’t need to use soldering irons or crimpers. Connectors with a solder wire connection prevent strands of wire from fraying while creating a secure connection.
IP67 rated connectors protect against dust and temporary submersion. IP68 rated connectors protect against dust and submersion. Note: Sockets and female receptacles may have extra holes on the face that are not used.
For technical drawings and 3-D models, click on a part number.

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
6 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.17" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 000000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.18" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 00000 |
| 5 | B | 0.2" | 60V AC/75V DC | 3 | 24 | 0.2" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 000000 | 00000 |
13 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.17" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 00000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.18" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 00000 |
| 5 | B | 0.2" | 60V AC/75V DC | 3 | 24 | 0.2" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 00000 |

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | For Wire Gauge | For Cable OD | Color | Housing Material | Size | Pitch, mm | Max. Temp., °F | Environmental Rating | Each | |
| 3 | A | 0.2" | 60V AC/60V DC | 4 | 26-20 | 0.14"-0.2" | Black | Nylon Plastic | M8 | 1 | 175° | IP67 | 0000000 | 000000 |

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | For Wire Gauge | For Cable OD | Color | Housing Material | Size | Pitch, mm | Max. Temp., °F | Environmental Rating | Each | |
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24-20 | 0.14"-0.2" | Black | Nylon Plastic | M8 | 1 | 175° | IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24-20 | 0.14"-0.2" | Black | Nylon Plastic | M8 | 1 | 175° | IP67 | 0000000 | 00000 |

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
6 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.17" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.18" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |
| 5 | B | 0.2" | 60V AC/75V DC | 3 | 24 | 0.2" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |
13 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.17" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.18" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |
| 5 | B | 0.2" | 60V AC/75V DC | 3 | 24 | 0.2" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | For Wire Gauge | For Cable OD | Color | Housing Material | Size | Pitch, mm | Max. Temp., °F | Environmental Rating | Each | |
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24-20 | 0.14"-0.2" | Black | Nylon Plastic | M8 | 1 | 175° | IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24-20 | 0.14"-0.2" | Black | Nylon Plastic | M8 | 1 | 175° | IP67 | 0000000 | 00000 |

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
6 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.17" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 000000 | 000000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.18" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 00000 |
| 5 | B | 0.2" | 60V AC/75V DC | 3 | 24 | 0.2" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 00000 |
13 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.17" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 00000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.18" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 00000 |
| 5 | B | 0.2" | 60V AC/75V DC | 3 | 24 | 0.2" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP68 | 0000000 | 00000 |

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
6 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.17" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 000000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.18" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |
| 5 | B | 0.2" | 60V AC/75V DC | 3 | 24 | 0.2" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |
13 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.17" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |
| 4 | A | 0.2" | 60V AC/75V DC | 4 | 24 | 0.18" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |
| 5 | B | 0.2" | 60V AC/75V DC | 3 | 24 | 0.2" | PVC Plastic | Yellow | Polyester Plastic | M8 | 1 | 0° to 220° | IP67 | 0000000 | 00000 |
M5 Connectors
One of the smallest signal/power connectors we offer. They have an A-coded face and are often used to send signal and power to automated systems and Profibus systems. All are rated IP67.
Sockets and female receptacles may have extra holes on the face that are not used.
For technical drawings and 3-D models, click on a part number.

Housing Thread | 4 1/2 ft. Cable Lead Lg. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Number of Keyways | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
| 3 | 1 | A | 0.12" | 60V AC/60V DC | 1A | 26 | 0.13" | Black | Polyurethane Rubber | M5 | 0.5 | 0° to 175° | IP67 | 0000000 | 000000 |
| 4 | 1 | A | 0.12" | 60V AC/60V DC | 1A | 26 | 0.14" | Black | Polyurethane Rubber | M5 | 0.5 | 0° to 175° | IP67 | 0000000 | 00000 |

Housing Thread | 4 1/2 ft. Cable Lead Lg. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Number of Keyways | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
| 3 | 1 | A | 0.12" | 60V AC/60V DC | 1A | 26 | 0.13" | Black | Polyurethane Rubber | M5 | 0.5 | 0° to 175° | IP67 | 0000000 | 000000 |
| 4 | 1 | A | 0.12" | 60V AC/60V DC | 1A | 26 | 0.14" | Black | Polyurethane Rubber | M5 | 0.5 | 0° to 175° | IP67 | 0000000 | 00000 |

Housing Thread | 4 1/2 ft. Cable Lead Lg. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Number of Keyways | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
| 3 | 1 | A | 0.12" | 60V AC/60V DC | 1A | 26 | 0.13" | Black | Polyurethane Rubber | M5 | 0.5 | 0° to 175° | IP67 | 0000000 | 000000 |
| 4 | 1 | A | 0.12" | 60V AC/60V DC | 1A | 26 | 0.14" | Black | Polyurethane Rubber | M5 | 0.5 | 0° to 175° | IP67 | 0000000 | 00000 |

Housing Thread | 4 1/2 ft. Cable Lead Lg. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Number of Keyways | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Color | Housing Material | Size | Pitch, mm | Temp. Range, °F | Environmental Rating | Each | |
| 3 | 1 | A | 0.12" | 60V AC/60V DC | 1A | 26 | 0.13" | Black | Polyurethane Rubber | M5 | 0.5 | 0° to 175° | IP67 | 0000000 | 000000 |
| 4 | 1 | A | 0.12" | 60V AC/60V DC | 1A | 26 | 0.14" | Black | Polyurethane Rubber | M5 | 0.5 | 0° to 175° | IP67 | 0000000 | 00000 |
Nano M8/Micro M12 Splitters



Join two devices with M8 connectors to a single cord, distribution block, or I/O module with M12 connectors to save space and reduce the number of cords in industrial automation setups. Often used with sensors and switches, these splitters send or receive two signals through one connection. Rated IP65 and IP67, they’ll stand up to dust, low-pressure washdowns, and brief submersion.
Note: M12 plugs have an extra pin on the face that is not used.
For technical drawings and 3-D models, click on a part number.
Plug | Sockets | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Housing Thread Size | No. of Poles | No. of Keyways | Face Dia. | Housing Thread Size | No. of Poles | No. of Keyways | Face Dia. | Coding | Voltage | Current, A | Housing Material | Color | Temp. Range, °F | Specifications Met | Each | |
Screw-Together Male Plug (Metric External Threads) × Screw-Together Female Sockets (Metric Internal Threads) | ||||||||||||||||
| M12 × 1mm | 4 | 0 | 0.3" | M8 × 1mm | 3 | 0 | 0.2" | A | 60V AC/60V DC | 4 | Polyurethane Rubber | Black | -10° to 185° | C-UL Listed, UL-Listed | 0000000 | 000000 |