Minimum Input Voltage Minimum Input Voltage | Show |
---|
|
Minimum Input Voltage Minimum Input Voltage | Hide |
---|
Mounting Location Mounting Location |
---|
![]() | DIN Rail |
Electrical Phase Electrical Phase |
---|
|
Input Wire Connection Type Input Wire Connection Type |
---|
|
Housing Color Housing Color |
---|
![]() | Gray |
Housing Material Housing Material |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Input Current Input Current |
---|
|
Output Wire Connection Type Output WireConnection Type |
---|
|
Specifications Met Specifications Met |
---|
|
Protections Provided Protections Provided |
---|
|
Mount these DC converters to DIN rails on fixtures such as industrial cabinets and electrical panels. By converting voltages, they let you connect power supplies to equipment that requires a different input voltage. They’re often used to power sensors or other components that require a lower voltage than surrounding equipment. Since they send a stable, consistent voltage to equipment, they can also be used to correct power supplies that send uneven voltages. All meet U.S. and Canadian, or European Union, safety standards.
If you exceed current limits, these converters will shut down to protect your equipment. Some converters have overvoltage or overload protection, as well.
The lower a converter’s maximum output noise, also known as ripple noise, the less electronic interference it creates. These converters will work in most applications.
For technical drawings and 3-D models, click on a part number.
Output | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Voltage (Adjustment Range) | Current, A | Power, W | Max. Output Noise, mVpp | Ht. | Wd. | Dp. | Mounting Fasteners Included | Specifications Met | Protections Provided | Each | |
Single Phase—12V DC-24V DC Input Voltage | |||||||||||
5V DC (4.75V DC-5.25V DC) | 0.6 | 3 | 100 | 3" | 1.5" | 2.6" | Yes | UL Recognized, CSA Certified | Overcurrent, Overload | 0000000 | 0000000 |
5V DC (4.75V DC-5.25V DC) | 1.5 | 7.5 | 100 | 3" | 1.5" | 2.6" | Yes | UL Recognized, CSA Certified | Overcurrent, Overload | 0000000 | 000000 |
12V DC (11.4V DC-12.6V DC) | 0.25 | 3 | 240 | 3" | 1.5" | 2.6" | Yes | UL Recognized, CSA Certified | Overcurrent, Overload | 0000000 | 000000 |
12V DC (11.4V DC-12.6V DC) | 0.6 | 7.5 | 240 | 3" | 1.5" | 2.6" | Yes | UL Recognized, CSA Certified | Overcurrent, Overload | 0000000 | 000000 |
15V DC (14.25V DC-15.75V DC) | 0.5 | 7.5 | 300 | 3" | 1.5" | 2.6" | Yes | UL Recognized, CSA Certified | Overcurrent, Overload | 0000000 | 000000 |
24V DC (22.8V DC-25.2V DC) | 0.3 | 7.5 | 480 | 3" | 1.5" | 2.6" | Yes | UL Recognized, CSA Certified | Overcurrent, Overload | 0000000 | 000000 |
Output | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Power, W | Max. Output Noise, mVpp | Ht. | Wd. | Dp. | Mounting Fasteners Included | Specifications Met | Protections Provided | Each | |
Single Phase—12V DC-24V DC Input Voltage | |||||||||||
-15V DC, 15V DC | 0.2 | 7.5 | 300 | 3" | 1.5" | 2.6" | Yes | UL Recognized, CSA Certified | Overcurrent, Overload | 0000000 | 0000000 |
These transformers produce AC output that most closely resembles clean, stable AC-generated power. Also known as inverters and converters, they prevent damage from overloads, short circuits, and overheating.
Voltage | Output | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Input | Output | Power, W | Current, A | Input Plug Type | Output Socket Type (NEMA Style) | Ht. | Wd. | Dp. | Each | |
Step Up Voltage | |||||||||||
1 | 12V DC | 120V AC | 125 | 1.1 | Vehicle | Three Slot (5-15) | 2.2" | 4.9" | 7.9" | 00000000 | 0000000 |
Use DC voltage to power devices that run on AC voltage. Also known as inverters and converters, they prevent damage from overloads.
Voltage | Output | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Input | Output | Power, W | Current, A | Output Socket Type (NEMA Style) | Ht. | Wd. | Dp. | Each | |
Single Phase—Screw Terminals Input and Socket Output | ||||||||||
Step Up Voltage | ||||||||||
3 | 12V DC | 120V AC | 700 | 5.8 | Three Slot (5-15) | 2.8" | 5" | 8.2" | 0000000 | 0000000 |
4 | 12V DC | 120V AC | 1,000 | 8.3 | Three Slot (5-15) | 4.3" | 6" | 13" | 0000000 | 000000 |
4 | 12V DC | 120V AC | 1,800 | 15 | Three Slot (5-15) | 4" | 6" | 15" | 0000000 | 000000 |
Provide AC power to devices that temporarily draw high output, such as motors. These transformers are designed to withstand starting surges up to twice the power output rating. Also known as inverters and converters, they prevent damage from overloads.
Voltage | Output | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of Outlets | Input | Output | Power, W | Current, A | Output Socket Type (NEMA Style) | Ht. | Wd. | Dp. | Each | |
Step Up Voltage | ||||||||||
2 | 12V DC | 120V AC | 1,250 | 10.4 | Three Slot (5-15) | 7" | 8.8" | 9" | 0000000 | 0000000 |