At least five times as accurate as standard pressure transmitters, these transmitters sense pressure at an accuracy of ±0.1% and come with a calibration certificate traceable to NIST. They are commonly used in laboratories and testing applications. Also known as transducers, pressure transmitters convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range. Maximum pressure is the maximum spike in pressure a transmitter can withstand without damage. All transmitters are rated IP65 and NEMA 4X for use in washdown and corrosive environments.
These transmitters connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with Calibration Certificate Traceable to NIST | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, psi | Max. Pressure, psi | Input Voltage | Pipe Size | For No. of Wires | No. of Wire Leads | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Current Output—Wire Leads | ||||||||||
0-50 | 8,000 | 9-30V DC | 1/4 | 2 | 4 | 3 5/16" | 1 15/16" | IP65, NEMA 4X | 0000000 | 0000000 |
0-100 | 10,000 | 9-30V DC | 1/4 | 2 | 4 | 3 5/16" | 1 15/16" | IP65, NEMA 4X | 0000000 | 000000 |
0-150 | 10,000 | 9-30V DC | 1/4 | 2 | 4 | 3 5/16" | 1 15/16" | IP65, NEMA 4X | 0000000 | 000000 |
0-300 | 10,000 | 9-30V DC | 1/4 | 2 | 4 | 3 5/16" | 1 15/16" | IP65, NEMA 4X | 0000000 | 000000 |
0-750 | 10,000 | 9-30V DC | 1/4 | 2 | 4 | 3 5/16" | 1 15/16" | IP65, NEMA 4X | 0000000 | 000000 |
Remotely monitor pressure in general purpose applications such as pumping and compressing systems. These transmitters, also known as transducers, convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Maximum pressure is the maximum spike in pressure a transmitter can withstand without damage.
To view transmitter wiring diagrams, select a part number and click Product Detail.
4-20mA current output transmitters connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
DC voltage output transmitters connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Transmitters with calibration certificate traceable to NIST include documentation that states they've passed a test for accuracy.
Transmitters with Calibration Certificate Traceable to NIST | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pressure Range, psi | Max. Pressure, psi | Input Voltage | Pipe Size | For No. of Wires | Electrical Connection Thread Size | Ht. | Wd. | Each | |
0-15 | 30 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 0000000 |
0-30 | 60 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-50 | 100 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-60 | 120 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-100 | 200 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-200 | 400 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-300 | 600 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-500 | 1,000 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-1,000 | 2,000 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-1,500 | 3,000 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-3,000 | 6,000 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-5,000 | 7,500 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 00000000 | 000000 |
0-10,000 | 12,000 | 9-36V DC | 1/4 | 2 | PG-9 | 2 5/8" | 1 3/8" | 00000000 | 000000 |
Transmitters with Calibration Certificate Traceable to NIST | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pressure Range, psi | Max. Pressure, psi | Input Voltage | Pipe Size | For No. of Wires | Electrical Connection Thread Size | Ht. | Wd. | Each | |
0-15 | 30 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 0000000 |
0-30 | 60 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-50 | 100 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-60 | 120 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-100 | 200 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-200 | 400 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-300 | 600 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-500 | 1,000 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-1,000 | 2,000 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 0000000 | 000000 |
0-1,500 | 3,000 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 00000000 | 000000 |
0-3,000 | 6,000 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 00000000 | 000000 |
0-5,000 | 7,500 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 00000000 | 000000 |
0-10,000 | 12,000 | 14-36V DC | 1/4 | 3 | PG-9 | 2 5/8" | 1 3/8" | 00000000 | 000000 |
These transmitters are commonly used to monitor airflow and to indicate when filters in HVAC systems become clogged. They convert the difference in pressure between two points in a low-pressure system into an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. Transmitters will only provide accurate readings within the rated pressure range. They come with a calibration certificate traceable to NIST. Maximum pressure is the maximum spike in pressure a transmitter can withstand without damage. All transmitters are rated IP67 for protection in washdown environments.
These transmitters connect using three wires—two wires into the power supply and a separate wire that sends a voltage signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Mounting Holes | Transmitters with Calibration Certificate Traceable to NIST | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, in. of H2O | Max. Pressure, psi | Input Voltage | For Tube ID | For No. of Wires | For DIN Rail Ht., mm | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Each | |
0-10V DC Voltage Output—Screw Terminals | ||||||||||||
Surface Mount | ||||||||||||
-0.5 to 0.5, -1 to 1, -2.5 to 2.5, -5 to 5 | 10 | 13-30V DC | 3/16" | 3 | __ | No | 3/16" | 2 | 5 7/16" | 3 3/16" | 0000000 | 0000000 |
DIN Rail or Surface Mount | ||||||||||||
-0.5 to 0.5, -1 to 1, -2.5 to 2.5, -5 to 5 | 10 | 13-30V DC | 3/16" | 3 | 35 | No | 3/16" | 2 | 5 7/16" | 3 3/16" | 0000000 | 000000 |