About Brightness
More
About Light Appearance
More
Lenses for Ceiling Lights

Lenses disperse light to reduce glare and protect bulbs from damage. Cut to size using a band saw or shears.
Solid lenses keep bulbs hidden and distribute light evenly. Lenses with a prismatic or cracked ice pattern distribute light better than smooth lenses. Acrylic lenses won't turn yellow over time. Polycarbonate lenses are more impact-resistant than acrylic lenses, but they may yellow over time.
For technical drawings and 3-D models, click on a part number.
For Light Technology | Material | Clarity | Lg., ft. | Wd., ft. | Thick. | Pkg. Qty. | Pkg. | |
Small Pack | ||||||||
---|---|---|---|---|---|---|---|---|
Solid with Prismatic Pattern | ||||||||
LED, Fluorescent | Acrylic Plastic | Clear | 4 | 2 | 7/64" | 2 | 0000000 | 000000 |
LED, Fluorescent | Polycarbonate Plastic | Clear | 4 | 2 | 1/8" | 2 | 000000 | 000000 |
Large Pack | ||||||||
Solid with Prismatic Pattern | ||||||||
LED, Fluorescent | Acrylic Plastic | Clear | 4 | 2 | 7/64" | 10 | 0000000 | 000000 |
Wraparound-Lens Ceiling Lights

These fixtures disperse light from the sides as well as the bottom to produce ambient lighting ideal for indoor spaces such as offices and storage rooms. Rated for use in damp locations, these lights withstand humidity and moisture. All have a lens that disperses light evenly. Lights can be hardwired to operate on any of the voltages listed.
Those with a neutral light appearance emit a neutral white light often found in workspaces.
Add suspension hardware (sold separately) to hang lights from the ceiling. Suspension hardware for style A includes two wire rope slings with hooks and two wire rope clamps. No tools required—adjust the length and tighten clamps to secure.
For technical drawings and 3-D models, click on a part number.


Lights | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Lenses | |||||||||||||
Lg. | Wd. | Ht. | Equiv. Fluorescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Mounting Hardware Included | Mounting Hole Diameter (No. of) | Each | Each | |||
A | 24" | 10" | 2 3/4" | 2 bulbs × 17W | 120V AC, 208V AC, 240V AC, 277V AC | 2,000 | Neutral (4,000K) | 17W | No | 7/8" (3), 11/16" (2) | 0000000 | 0000000 | 000000 | 00 |
A | 48" | 10" | 2 3/4" | 2 bulbs × 32W | 120V AC, 208V AC, 240V AC, 277V AC | 4,200 | Neutral (4,000K) | 32W | No | 7/8" (3), 11/16" (2) | 0000000 | 000000 | 000000 | 00 |
A | 48" | 8 5/8" | 2 3/4" | 2 bulbs × 32W | 120V AC, 277V AC | 5,000 | Neutral (4,000K) | 53W | No | 9/32" (2) | 0000000 | 000000 | 0000000 | 000000 |
A | 96" | 8 5/8" | 2 3/4" | 4 bulbs × 32W | 120V AC, 277V AC | 10,000 | Neutral (4,000K) | 106W | No | 9/32" (4) | 0000000 | 000000 | 0000000 | 00000 |
Recessed Ceiling Lights


Also known as troffers, these lights fit most standard drop-ceiling grids, so they’re often used in indoor spaces such as offices and storage rooms. They can be hardwired to operate on any of the voltages listed. Solid lens are frosted and smooth or prismatic to disperse light evenly. With built-in LEDs, these lights last longer, are more efficient, and generate less heat than fluorescent lights. They emit a neutral white light often found in workspaces.
Overall | Lens | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Wd. | Ht. | Equiv. Fluorescent Bulb Wattage | Voltage | Brightness, lumens | Wattage | Material | Clarity | Pattern | Each | |
Built-In LED Bulbs— Solid Lens | |||||||||||
24" | 24" | 3 1/4" | 2 bulbs × 32W | 120V AC, 208V AC, 240V AC, 277V AC | 3,800 | 27.61W | Acrylic Plastic | Frosted | Prismatic | 00000000 | 0000000 |
48" | 24" | 3 1/4" | 4 bulbs × 32W | 120V AC, 208V AC, 240V AC, 277V AC | 5,000 | 41W | Acrylic Plastic | Frosted | Prismatic | 00000000 | 000000 |
Battery-Operated Motion-Sensing Ceiling Lights

Mount these fixtures where you need light but don't have an electrical connection. They turn on when movement is detected and off when an area is unoccupied, so they work well in hallways and small storage areas. Long-lasting and energy efficient, these lights have built-in LEDs. They emit a neutral white light often found in workspaces. A prismatic, frosted lens disperses light evenly.
Overall | Batteries | Mounting Holes | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dia. | Ht. | Equiv. Incandescent Bulb Wattage | Brightness, lumens | Light Appearance | Wattage | Max. Sensing Distance, ft. | No. Required | Included | Size | Mounting Hardware Included | No. of | Dia. | Environment | Environmental Rating | Each | |
Built-In LED Bulbs | ||||||||||||||||
8" | 2 1/4" | 30W | 300 | Neutral (4,000K) | 3W | 15 | 4 | No | D | Yes | 4 | 3/16" | Wet Location | IP04 | 0000000 | 000000 |
Hazardous Location Ceiling and Wall Lights with Guard



Also known as jelly jar lights. These fixtures have a heat-resistant lens and a guard that protects the lens from breaking. They are CSA certified for hazardous locations where flammable/combustible gases, vapors, and liquids may be present. They are rated NEMA 4X for protection against corrosion and washdowns. Lights are sealed to keep moisture out. They can be hardwired to operate on any of the voltages listed. Some work with LED or incandescent bulbs (sold separately).
Styles 4 and 7 can be used in environments where ignitable concentrations of hazardous material are present under normal operating conditions, and/or during frequent equipment maintenance or failure. Rated for Class I, Divisions 1 and 2, Groups C and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2, these lights withstand ethylene, propane, conductive or metal dusts, carbonaceous dusts, nonconductive dusts, and combustible/ignitable fibers or flyings.
O'all | Mounting Holes | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Dia. | Ht. | Dp. | Voltage | Bulbs Included | No. of Bulbs Required | Screw-In Base Size | Max. Wattage per Bulb | Housing Material | For Conduit Trade Size | Thread Type | Mounting Hardware Included | No. of | Dia. | Specifications Met | Each | |
For Incandescent Bulbs | |||||||||||||||||
Ceiling Fastener Mount | |||||||||||||||||
4 | 7 1/2" | 14 3/8" | __ | 120V AC, 208V AC, 240V AC | No | 1 | Medium (Standard Household) | 150W | Aluminum | 3/4 | NPT | No | 4 | 5/16" | CSA Certified, MS16555-650, MS9321-9 | 0000000 | 0000000 |
Wall Fastener Mount | |||||||||||||||||
7 | 7 1/2" | 15 7/8" | 14 1/2" | 120V AC, 208V AC, 240V AC | No | 1 | Medium (Standard Household) | 150W | Aluminum | 3/4 | NPT | No | 2 | 1/4" | CSA Certified, MS16555-650, MS9321-9 | 0000000 | 00000000 |
Dusk-to-Dawn Wall Lights

Also known as wall packs, these lights mount to exterior walls to illuminate building perimeters, entryways, loading docks, and other outdoor areas. No need for timers—a sensor automatically turns the light on at dusk and off at dawn. With built-in LEDs, these lights last longer, are more efficient, and generate less heat than other technologies. They produce a neutral white light appearance. The lens is prismatic to disperse light evenly, and made of durable, impact-resistant polycarbonate.
Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Equiv. Metal Halide Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Wd. | Ht. | Dp. | Environment | Mounting Hardware Included | Each | |
Built-In LED Bulbs | |||||||||||
100W | 120V AC | 1,600 | Neutral (3000K, 4000K, 5000K) | 18.5W | 5 3/8" | 10 1/2" | 3" | Wet Location | Yes | 00000000 | 000000 |
Security Lights





Also known as wall packs, these lights mount to exterior walls and ceilings. With built-in LEDs, they last longer, are more efficient, and generate less heat than other technologies. They can be hardwired to operate on any of the voltages listed. All have a prismatic lens that disperses light evenly.
Lights with a cool light appearance highlight white/blue tones creating good visibility at night.
Style A and D lights can be set to cool, neutral, or warm color appearances.
Ceiling-mount lights are also known as canopy lights.
Lights with a polycarbonate lens are more impact resistant than lights with a glass lens.
Lights with a photocell switch on/off automatically when they detect the presence or absence of light.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Mounting Location | Equiv. Metal Halide Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Wd. | Ht. | Dp. | Environment | Mounting Hardware Included | No. of | Dia. | Features | Each | |
Built-In LED Bulbs | ||||||||||||||||
Glass Lens—Prismatic | ||||||||||||||||
A | Wall | __ | 120V AC, 208V AC, 240V AC, 277V AC | __ | Cool (5000K) Neutral (4000K) Warm (3000K) | __ | 18" | 9" | 6 1/4" | Wet Location | No | 3 | 5/16" | Photocell | 00000000 | 0000000 |
A | Wall | 175W | 120V AC, 208V AC, 240V AC, 277V AC | __ | Cool (5000K) Neutral (4000K) Warm (3000K) | __ | 14 3/8" | 9 5/16" | 6 5/16" | Wet Location | No | 10 | 1/4" | Photocell | 00000000 | 000000 |
Polycarbonate Plastic Lens—Prismatic | ||||||||||||||||
B | Wall | 50W | 120V AC, 208V AC, 240V AC, 277V AC | 1,400 | Neutral (4000K) | 12W | 6" | 9" | 4" | Wet Location | Yes | 4 | 1/4" | __ | 0000000 | 000000 |
C | Ceiling | 50W | 120V AC, 208V AC, 240V AC, 277V AC | 2,300 | Neutral (4000K) | 20W | 12" | 12" | 5" | Wet Location | Yes | 4 | 1/4" | __ | 0000000 | 000000 |
Acrylic Plastic Lens—Prismatic | ||||||||||||||||
F | Wall | 70W | 120V AC, 208V AC, 240V AC, 277V AC | 3,000 | Neutral (4000K) | 11W | 11" | 5" | 6 1/2" | Wet Location | Yes | 4 | 1/4" | __ | 000000000 | 000000 |
Polyester Plastic Lens—Prismatic | ||||||||||||||||
D | Ceiling | 150W | 120V AC, 208V AC, 240V AC, 277V AC | __ | Cool (5000K) Neutral (4000K) Warm (3000K) | __ | 10" | 10" | 3" | Wet Location | Yes | 4 | 1/2" | __ | 000000000 | 000000 |
Emergency Backup Lights

When the power goes out, these lights go on. These backup lights have built-in LEDs so they last longer, are more efficient, and generate less heat than other technologies. Rated for use in damp locations, these lights withstand exposure to humidity and moisture. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed.
Lights with a plastic housing resist corrosion better than lights with a steel housing.
Overall | Mounting Holes | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Housing Material | Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Each | |
Built-In LED Bulbs | |||||||||||||||
Plastic | 9 3/4" | 4 3/4" | 3 1/8" | 10W | 120V AC, 277V AC | 220 | Cool (5000K) | 2.4W | Yes | 1.5 | No | 4 | 3/16" | 0000000 | 000000 |
Wet-Location Emergency Backup Lights

Lights that cannot be sold to California or Oregon are restricted due to energy efficiency requirements.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Equiv. Incandescent Bulb Wattage | Voltage | Brightness, lumens | Light Appearance | Wattage | Batteries Included | Run Time, hrs. | Mounting Hardware Included | Cannot Be Sold To | Each | |
Built-In LED Bulbs | |||||||||||||
8" | 12 1/4" | 3 1/2" | 5W | 120V AC, 277V AC | 100 | Cool (5000K) | 3.75W | Yes | 1.5 | Yes | CA, OR | 0000000 | 0000000 |
Hazardous Location Emergency Backup Lights

These lights are UL listed for Class I, Division 2, Groups A, B, C, and D for use in environments where ignitable concentrations of hazardous material occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. They withstand acetylene, hydrogen, ethylene, and propane. Lights can be hardwired to operate on any of the voltages listed. They have a low-voltage disconnect so they won’t drain the backup battery. Use the test switch to check that the heads and battery are working properly. Heads adjust to any angle to direct light where needed. They cannot be sold to the listed areas due to energy efficiency requirements.
Overall | Mounting Holes | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Voltage | Bulbs Included | Brightness, lumens | Light Appearance | Max. Wattage per Bulb | Batteries Included | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Specifications Met | Cannot Be Sold To | Each | |
For LED Bulbs | ||||||||||||||||
10 5/16" | 16 1/2" | 5 1/2" | 120V AC, 277V AC | Yes | 800 | Cool (5000K) | 5W | Yes | 1.5 | No | 4 | 5/16" | UL Listed | CA, OR, VT | 00000000 | 000000000 |