Cooling Capacity Cooling Capacity |
---|
|
For Use With For Use With |
---|
|
For System Type For System Type |
---|
|
Maximum Flow Rate Maximum Flow Rate |
---|
|
Pump Capacity Pump Capacity |
---|
|
Pump Type Pump Type |
---|
|
Tank Material Tank Material |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Mobility Mobility |
---|
|
About Liquid Chillers
More
High-Flow Liquid Chillers



For more cooling capacity than other liquid chillers, these have a heavy duty pump that can handle higher flow rates and pressures. They provide constant, uniform cooling to water or glycol solutions used in temperature-sensitive equipment, such as spot-welding systems, molds, lasers, and X-ray diffraction equipment. All have an internal tank to ensure liquid flows in a continuous loop. They are used to cool liquid in process equipment. Adjust the set temperature with the keypad.
Chillers rated for 4,300 and 11,300 Btu/hr. have a cooling capacity based on a 65° F liquid temperature and a 95° F room temperature.
Chillers rated for 24,000 to 60,000 Btu/hr. have a cooling capacity based on a 65° F liquid temperature and a 90° F room temperature.
Chillers with a bypass valve recirculate liquid in the chiller if the outlet is obstructed.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Voltage (Electrical Phase) | Current | Hp | Max. Flow Rate | Max. Pressure, psi | Temp. Control Range, °F | Ht. | Wd. | Dp. | Tank Cap., gal. | Refrigerant Number | Features | Each | |
For Closed Loop Systems | ||||||||||||||
4,300 | 120V AC (Single) | 15.5A | 1/2 | 4 gpm @ 50 psi | 50 | 50° to 80° | 28 5/8" | 22" | 21 1/8" | 5 | R-134A | Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 |
11,300 | 240V AC (Single) | 17A | 1 | 4 gpm @ 50 psi | 50 | 50° to 80° | 33 3/8" | 31 1/8" | 25 1/8" | 10 | R-134A | Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 00000000 |
24,000 | 240V AC (Three) | 22A | 2 | 10 gpm @ 35 psi | 35 | 50° to 80° | 35 11/16" | 33 1/2" | 31 5/8" | 10 | R-134A | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 00000000 |
36,000 | 460V AC (Three) | 11A | 3 | 10 gpm @ 45 psi | 45 | 50° to 80° | 65" | 37" | 34 1/2" | 36 | R-407C | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 |
60,000 | 460V AC (Three) | 16A | 5 | 15 gpm @ 45 psi | 45 | 50° to 80° | 65" | 37" | 34 1/2" | 36 | R-407C | Bypass Valve, Cleanable Air-Intake Filter, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 |
Precision Liquid Chillers

These liquid chillers maintain a stable temperature within 0.18° F for the most precise temperature control. They provide constant, uniform cooling to water or glycol solutions used in temperature-sensitive equipment, such as spot-welding systems, molds, lasers, and X-ray diffraction equipment. All have an internal tank to ensure liquid flows in a continuous loop. Use them to cool liquid in process equipment. Adjust the set temperature with the keypad.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Voltage (Electrical Phase) | Current | Hp | Max. Flow Rate | Max. Pressure, psi | Temp. Control Range, °F | Ht. | Wd. | Dp. | Tank Cap., gal. | Refrigerant Number | Each | |
For Closed-Loop/Open-Loop Systems | |||||||||||||
2,900 | 120V AC (Single) | 13.7A | 1/4 | 3.5 gpm @ 0 psi | 90 | 15° to 155° | 21 7/8" | 15" | 26" | 1.1 | R-134A | 0000000 | 000000000 |
5,940 | 120V AC (Single) | 17.4A | 1/2 | 3.5 gpm @ 0 psi | 90 | 15° to 155° | 21 7/8" | 15" | 26" | 1.1 | R-134A | 0000000 | 00000000 |
9,900 | 230V AC (Single) | 13.5A | 1 | 3.5 gpm @ 0 psi | 90 | 15° to 155° | 21 7/8" | 15" | 26" | 1.1 | R-134A | 0000000 | 00000000 |