    Compact Pressure Switches

    With a round body that’s at least one-third thinner than traditional pressure switches, these fit in tight, cramped spaces. They’re often built into pumps and hydraulic systems with limited space in order to turn equipment on and off, activate automated controls, or signal alarms when they reach a set pressure. These switches are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They also meet at least one American, Canadian, or European safety standard.
    Quick-Disconnect-Terminal Wire Connection
    Image of Product. Top orientation. Pressure Switches. Compact Pressure Switches, Quick-Disconnect-Terminal Wire Connection.
    External Adjustment—Switches with an external setpoint adjustment have an external ring, so you can set the pressure quickly by hand.
    Internal Adjustment—Switches with an internal setpoint adjustment have a sliding cover to prevent accidental setting changes.
    NEMA 1 Enclosure Rating—NEMA 1 rated switches protect against corrosion.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
     
    External Adjustment
    1.6 to 2813075±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N110000000
    3 to 481.55075±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N12000000
    4.5 to 962100150±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N13000000
    9.7 to 2405250375±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N14000000
    20 to 48510500750±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N15000000
    100 to 800605,0006,000±5%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 255316 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N22000000
    500 to 3,0001353,0004,000±6%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 255316 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    CE Marked
    7799N24000000
    600 to 5,0002905,0006,000±6%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 255316 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    CE Marked
    7799N26000000
     
    Internal Adjustment
    4 to 503.51,0003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K81000000
    10 to 15061,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K1000000
    30 to 600342,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K2000000
     
    1/4 Threaded NPT Male Pipe
     
    Internal Adjustment
    100 to 1,5001208,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K82000000
    180 to 3,0002258,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K3000000
    400 to 4,7003508,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K83000000
    4,000 to 7,50067510,00012,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K84000000
     
    Wire Lead Connection
    Image of Product. Front orientation. Pressure Switches. Compact Pressure Switches, Wire Lead Connection.
    External Adjustment—Switches with an external setpoint adjustment have an external ring, so you can set the pressure quickly by hand.
    Internal Adjustment—Switches with an internal setpoint adjustment have a sliding cover to prevent accidental setting changes.
    IP67 Enclosure Rating and NEMA 6 Enclosure Rating—IP67 and NEMA 6 rated switches seal out dust and water from washdowns and temporary submersion.
    NEMA 1 Enclosure Rating—NEMA 1 rated switches protect against corrosion.
    NEMA 4 Enclosure Rating—NEMA 4 rated switches stand up to dusty and washdown areas as well as the outdoor elements.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
     
    External Adjustment
    1.6 to 2813075±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N160000000
    3 to 481.55075±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N17000000
    4.5 to 962100150±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N18000000
    9.7 to 2405250375±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N19000000
    20 to 48510500750±2%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 225303 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N21000000
    100 to 800605,0006,000±5%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 255316 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    7799N23000000
    500 to 3,0001353,0004,000±6%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 255316 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    CE Marked
    7799N25000000
    600 to 5,0002905,0006,000±6%3 amp @ 28V DC
    5 amp @ 250V AC
    -65 to 255316 Stainless SteelAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterNEMA 1
    CE Marked
    7799N27000000
     
    Internal Adjustment
    4 to 503.51,0003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K85000000
    10 to 15061,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K4000000
    30 to 600342,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K5000000
     
    1/4 Threaded NPT Male Pipe
     
    External Adjustment
    3 to 12.81.5151,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -20 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 4
    CSA Certified, UL Listed
    46995K98000000
    6 to 313351,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -20 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 4
    CSA Certified, UL Listed
    46995K14000000
    10 to 444501,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -20 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 4
    CSA Certified, UL Listed
    46995K16000000
    25 to 11281251,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -20 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 4
    CSA Certified, UL Listed
    46995K18000000
    80 to 220222501,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -20 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 4
    CSA Certified, UL Listed
    46995K22000000
    130 to 440425001,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -20 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 4
    CSA Certified, UL Listed
    46995K24000000
    250 to 450906007,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 1
    CSA Certified, UL Recognized Component
    46995K41000000
    430 to 1,4502201,7007,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 1
    CSA Certified, UL Recognized Component
    46995K42000000
    1,650 to 3,9004254,4007,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 1
    CSA Certified, UL Recognized Component
    46995K43000000
    4,000 to 6,7006007,50012,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 1
    CSA Certified, UL Recognized Component
    46995K44000000
     
    Internal Adjustment
    100 to 1,5001208,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K86000000
    180 to 3,0002258,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K6000000
    400 to 4,7003508,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K87000000
    500 to 5,00041510,00015,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked, CSA Certified, UL Listed
    6303N111000000
    4,000 to 7,50067510,00012,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K88000000
     
    7/16"-20 Threaded UN/UNF (SAE Straight) Male Pipe
     
    Internal Adjustment
    100 to 1,000905,0008,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked, CSA Certified, UL Listed
    6303N125000000
    200 to 2,0001655,0008,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked, CSA Certified, UL Listed
    6303N126000000
     
    DIN C Connection
    Image of Product. Front orientation. Pressure Switches. Compact Pressure Switches, DIN C Connection.
    External Adjustment—Switches with an external setpoint adjustment have an external ring, so you can set the pressure quickly by hand.
    Internal Adjustment—Switches with an internal setpoint adjustment have a sliding cover to prevent accidental setting changes.
    IP67 Enclosure Rating and NEMA 6 Enclosure Rating—IP67 and NEMA 6 rated switches seal out dust and water from washdowns and temporary submersion.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/4 Threaded NPT Male Pipe
     
    External Adjustment
    6 to 3038001,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N1310000000
    8 to 6068001,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N132000000
    10 to 10098001,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N133000000
    20 to 200168001,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N134000000
    50 to 500605,0008,000±2%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N135000000
    100 to 1,000855,0008,000±2%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N136000000
    200 to 2,0001655,0008,000±2%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N137000000
     
    Internal Adjustment
    500 to 5,00041510,00015,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N115000000
    750 to 7,50060510,00015,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N116000000
    1,500 to 15,0001,65015,00020,000±5%3 amp @ 125V AC
    2 amp @ 30V DC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N118000000
     
    7/16"-20 Threaded UN/UNF (SAE Straight) Male Pipe
     
    Internal Adjustment
    100 to 1,000905,0008,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N119000000
    200 to 2,0001655,0008,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Oil, WaterIP67, NEMA 6
    CE Marked
    6303N12000000
     

    Pressure Switches

    Image of Product. Style A. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style A.
    Image of Product. Style B. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style B.
    Image of Product. Style C. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style C.
    Image of Product. Style D. Top orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style D.

    Style A

    Style B

    Style C

    Style D

    Image of Product. Style E. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style E.
    Image of Product. Style F. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style F.
    Image of Product. Style G. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style G.
    Image of Product. Style H. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style H.

    Style E

    Style F

    Style G

    Style H

    Image of Product. Style J. Front orientation. Pressure Switches. Pressure Switches, Wire Lead Connection, Style J.
    Image of Product. Style K. Front orientation. Pressure Switches. Pressure Switches, Wire Lead Connection, Style K.
    Image of Product. Style L. Front orientation. Pressure Switches. Pressure Switches, Wire Lead Connection, Style L.

    Style J

    Style K

    Style L

    The traditional pressure switch. These power equipment, activate controls or alarms, or kick-off other actions when they reach a set pressure. Larger than compact pressure switches, they're easier to wire. These switches are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Pressure Switches
    Image of Product. Style A. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style A.
    Image of Product. Style B. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style B.

    Style A

    Style B

    Styles A and B—Styles A-C, E-J, and L meet at least one safety standard.
    NEMA 1 Enclosure Rating—NEMA 1 rated switches should only be used indoors.
    Style
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection
     
    1/4 Threaded NPT Male Pipe
    A3 to 300.9550230±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, Water3899N110000000
    A10 to 1001.5200300±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, Water3899N12000000
    A30 to 3002.5400500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, Water3899N13000000
    A50 to 5003.5600700±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, Water3899N14000000
     
    1/2 Threaded NPT Male Pipe
    B0.6 to 14.20.65151,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -20 to 165BrassAir, Hydraulic Fluid, Nitrogen, Oil, WaterNEMA 1
    40925K92000000
    B3.5 to 824901,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -20 to 165BrassAir, Hydraulic Fluid, Nitrogen, Oil, WaterNEMA 1
    40925K93000000
    B11 to 230102501,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -20 to 165BrassAir, Hydraulic Fluid, Nitrogen, Oil, WaterNEMA 1
    40925K94000000
    B29 to 472165001,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -20 to 165AluminumAir, Hydraulic Fluid, Nitrogen, Oil, WaterNEMA 1
    40925K13000000
     
    Pressure Switches with Cover
    Image of Product. Style C. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style C.
    Image of Product. Style D. Top orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style D.
    Image of Product. Style E. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style E.

    Style C

    Style D

    Style E

    Image of Product. Style F. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style F.
    Image of Product. Style G. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style G.
    Image of Product. Style H. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style H.

    Style F

    Style G

    Style H

    Image of Product. Style J. Front orientation. Pressure Switches. Pressure Switches, Wire Lead Connection, Style J.
    Image of Product. Style K. Front orientation. Pressure Switches. Pressure Switches, Wire Lead Connection, Style K.
    Image of Product. Style L. Front orientation. Pressure Switches. Pressure Switches, Wire Lead Connection, Style L.

    Style J

    Style K

    Style L

    Switches with a cover protect against impact and keep dust off the switch.
    Styles C, E, F, G, and J—Styles A-C, E-J, and L meet at least one safety standard.
    Styles H and L—Styles H and L have internal and external threads, so you can attach these switches to a male or female pipe connection. Styles A-C, E-J, and L meet at least one safety standard.
    IP65 Enclosure Rating—IP65 rated switches can be lightly rinsed.
    IP66 Enclosure Rating—IP66 switches withstand washdowns.
    NEMA 1 Enclosure Rating—NEMA 1 rated switches should only be used indoors.
    NEMA 4 Enclosure Rating and NEMA 4X Enclosure Rating—NEMA 4 and NEMA 4X rated switches can be used in dirty and wet areas exposed to washdowns and the weather. NEMA 4X also has increased protection against corrosion, similar to 304 stainless steel.
    NEMA 13 Enclosure Rating—NEMA 13 rated switches can be used in dirty, damp, and oily areas.
    Style
    Pressure Set Point Range
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection Material
    For Use With
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection
     
    1/4 Threaded NPT Female Pipe
    C2.25 psi to 15 psi1 psi15 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    46025K550000000
    C4.5 in. H₂O to 30 in. H₂O2.5 in. H₂O30 in. H₂O20±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    46025K51000000
    C4.5 psi to 30 psi1 psi30 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    46025K56000000
    C9 psi to 60 psi3 psi60 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    46025K57000000
    C15 psi to 100 psi4.5 psi100 psi1,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    46025K58000000
    C30 psi to 200 psi12 psi200 psi1,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    46025K59000000
    C60 psi to 400 psi20 psi400 psi2,400±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    46025K81000000
    D40 psi to 235 psi25 psi250 psi4,500±2%10 amp @ 125V AC
    10 amp @ 250V AC
    10 amp @ 480V AC
    2 amp @ 600V AC
    50 mA @ 125V DC
    30 mA @ 250V DC
    -40 to 165416 Stainless SteelAir, Hydraulic Fluid, WaterNEMA 13
    4735K51000000
    D60 psi to 460 psi40 psi500 psi6,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    10 amp @ 480V AC
    2 amp @ 600V AC
    50 mA @ 125V DC
    30 mA @ 250V DC
    -40 to 165416 Stainless SteelAir, Hydraulic Fluid, WaterNEMA 13
    4735K52000000
    D115 psi to 1,425 psi95 psi1,500 psi7,500±2%10 amp @ 125V AC
    10 amp @ 250V AC
    10 amp @ 480V AC
    2 amp @ 600V AC
    50 mA @ 125V DC
    30 mA @ 250V DC
    -40 to 165416 Stainless SteelAir, Hydraulic Fluid, WaterNEMA 13
    4735K53000000
    D240 psi to 2,825 psi210 psi3,000 psi10,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    10 amp @ 480V AC
    2 amp @ 600V AC
    50 mA @ 125V DC
    30 mA @ 250V DC
    -40 to 165416 Stainless SteelAir, Hydraulic Fluid, WaterNEMA 13
    4735K54000000
    D395 psi to 4,650 psi305 psi5,000 psi10,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    10 amp @ 480V AC
    2 amp @ 600V AC
    50 mA @ 125V DC
    30 mA @ 250V DC
    -40 to 165416 Stainless SteelAir, Hydraulic Fluid, WaterNEMA 13
    4735K55000000
    D815 psi to 9,450 psi435 psi10,000 psi15,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    10 amp @ 480V AC
    2 amp @ 600V AC
    50 mA @ 125V DC
    30 mA @ 250V DC
    -40 to 165416 Stainless SteelAir, Hydraulic Fluid, WaterNEMA 13
    4735K56000000
     
    1/4 Threaded NPT Male Pipe
    E3 psi to 30 psi0.85 psi50 psi230±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, WaterNEMA 1
    4779K22000000
    E10 psi to 100 psi1.5 psi200 psi300±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, WaterNEMA 1
    4779K23000000
    E30 psi to 300 psi2.5 psi400 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, WaterNEMA 1
    4779K24000000
     
    1/2 Threaded NPT Female Pipe
    F1 psi to 20 psi0.55 psi500 psi1,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316L Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    3899N15000000
    F5 psi to 30 psi2 psi1,500 psi2,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K71000000
    F10 psi to 100 psi4.5 psi1,500 psi2,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K72000000
    F15 psi to 300 psi10 psi1,500 psi2,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K73000000
    F20 psi to 500 psi17 psi1,500 psi2,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K74000000
    F80 psi to 1,700 psi62 psi2,000 psi2,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K75000000
     
    1/2 Threaded NPT Male Pipe
    G0.6 psi to 14.2 psi0.65 psi15 psi1,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -20 to 165BrassAir, Hydraulic Fluid, Nitrogen, Oil, WaterIP65, NEMA 4
    40925K11000000
    G3.5 psi to 82 psi4 psi90 psi1,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -20 to 165BrassAir, Hydraulic Fluid, Nitrogen, Oil, WaterIP65, NEMA 4
    40925K12000000
    G11 psi to 230 psi10 psi250 psi1,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -20 to 165BrassAir, Hydraulic Fluid, Nitrogen, Oil, WaterIP65, NEMA 4
    3899N25000000
    G29 psi to 472 psi16 psi500 psi1,000±2%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -20 to 165AluminumAir, Hydraulic Fluid, Nitrogen, Oil, WaterIP65, NEMA 4
    3899N26000000
     
    1/4 Threaded NPT Female Pipe and 1/2 Threaded NPT Male Pipe
    H150 psi to 1,000 psi98 psi1,000 psi12,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    46025K83000000
    H450 psi to 3,000 psi220 psi3,000 psi12,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    3899N16000000
     
    Wire Lead Connection
     
    1/4 Threaded NPT Female Pipe
    J4.5 psi to 30 psi1 psi30 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    3899N17000000
    J9 psi to 60 psi3 psi60 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    3899N18000000
    J15 psi to 100 psi4.5 psi100 psi1,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    3899N19000000
    J30 psi to 200 psi12 psi200 psi1,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    3899N21000000
    J60 psi to 400 psi20 psi400 psi2,400±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    3899N22000000
    K0.068 psi to 1.6 psi0.04 psi1.7 psi3±0.5%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -65 to 165304 Stainless SteelAir, Hydraulic Fluid, Nitrogen, Oil, WaterNEMA 4
    5004K51000000
    K0.18 psi to 2.8 psi0.11 psi3 psi10±0.5%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -65 to 165304 Stainless SteelAir, Hydraulic Fluid, Nitrogen, Oil, WaterNEMA 4
    5004K52000000
    K0.66 psi to 17 psi0.19 psi18 psi60±0.5%10 amp @ 125V AC
    10 amp @ 250V AC
    3 amp @ 480V AC
    -65 to 165304 Stainless SteelAir, Hydraulic Fluid, Nitrogen, Oil, WaterNEMA 4
    5004K53000000
     
    1/4 Threaded NPT Female Pipe and 1/2 Threaded NPT Male Pipe
    L150 psi to 1,000 psi98 psi1,000 psi12,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    3899N23000000
    L450 psi to 3,000 psi220 psi3,000 psi12,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Oil, WaterIP66, NEMA 4X
    3899N24000000
     

    Fixed Setpoint Pressure Switches

    Image of Product. Top orientation. Contains Annotated. Pressure Switches. Fixed Setpoint Pressure Switches, Screw-Terminal Wire Connection.
    Image of Product. Front orientation. Contains Annotated. Pressure Switches. Fixed Setpoint Pressure Switches, Wire Lead Connection.

    Screw-Terminal

    Wire Connection

    Wire Lead

    Connection

    Prevent changes to the set pressure that activates equipment—these switches come ready to use at your preferred setpoint. Often used to turn equipment on and off when a set pressure is reached, they can also be used to activate automated controls or signal alarms. They’re single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed).
    NEMA 4 and 13 rated, they seal out dirt, oil, and water from washdowns. These switches are also UL and C-UL recognized components and are CE marked, so they meet American, Canadian, and European safety standards.
    Pressure Set
    Point, psi
    Approx. Reset
    Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection
     
    1/8 NPT Male Pipe
    108.22,0006,000±1%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11000000
    15132,0006,000±1.5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K1200000
    20172,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K1300000
    25212,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K1400000
    30252,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K1500000
    35292,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K1600000
    40332,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K1700000
    45372,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K1800000
    50412,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K1900000
    55462,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K2100000
    60502,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K2200000
    65542,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K2300000
    70582,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K2400000
    75622,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K2500000
    80662,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K2600000
    85702,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K2700000
    90742,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K2800000
    95782,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K2900000
    100822,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K3100000
    105872,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K3200000
    110912,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K3300000
    115952,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K3400000
    120992,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K3500000
    1251052,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K3600000
    1301102,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K3700000
    1351152,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K3800000
    1401152,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K3900000
    1451202,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K4100000
    1501252,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K4200000
    1751452,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K4700000
    2001652,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K5300000
    2502052,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K6400000
    3002502,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K7500000
     
    1/4 NPT Male Pipe
    1082,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K8100000
    15122,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K8200000
    20172,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K8300000
    25212,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K8400000
    30352,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K8500000
    35302,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K8600000
    40322,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K8700000
    45382,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K8800000
    50422,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K8900000
    60512,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K9100000
    70592,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K9200000
    75632,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K9300000
    80682,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K9400000
    85722,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K9500000
    90762,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K9600000
    100852,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K9700000
    1201022,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K9800000
    1501272,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K9900000
    2001702,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11100000
    2502122,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11200000
    3002552,0006,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11300000
     
    Wire Lead Connection
     
    1/4 NPT Male Pipe
    5004255,00015,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11400000
    1,0008505,00015,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11500000
    Fixed Setpoint Pressure Switch with Wire Leads, 1/4 NPT Male Connection, 1000 PSI Setpoint
    EachIn stock
    1,5001,2505,00015,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11600000
    2,0001,7005,00015,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11700000
    2,5002,1255,00015,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11800000
    3,0002,5505,00015,000±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    3454K11900000
     

    Pressure Switches for Air Compressors

    Maintain the air pressure needed for air-powered devices. These switches turn your electric air compressor off when it reaches the set pressure and on when it reaches the reset pressure. All are NEMA rated to protect their parts from dirt and stand up to some corrosion, but they shouldn’t be used outdoors. UL listed and CSA certified, all meet American and Canadian safety standards. Those that are CE marked meet European safety standards.
    Pressure Switches
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Air Compressors.
    Polycarbonate Housing and Polypropylene Housing—Switches with plastic housing stand up to corrosion.
    Steel Housing—Switches with steel housing are impact resistant.
    Reset
    Point, psi
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Min.
    Max.
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    Process Temp.
    Range, ° F
    Connection
    Material
    AC (Single Phase)
    AC (Three Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Polycarbonate Housing—1/4 NPT Female Pipe
    80 to 1006011020110±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K612000000
    95 to 1255014529145±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K61600000
     
    Polypropylene Housing—1/4 NPSF Female Pipe
    20 to 805602280±3%-20 to 255Zinc-Plated Steel2 hp @ 115V AC
    3 hp @ 230V AC
    3 hp @ 115V AC
    5 hp @ 230V AC
    1 hp @ 115V DC
    1 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K1100000
    40 to 100208020100±3%-20 to 255Zinc-Plated Steel1 1/2 hp @ 115V AC
    2 hp @ 230V AC
    2 hp @ 115V AC
    3 hp @ 230V AC
    Screw TerminalNEMA 1
    4154K1500000
    60 to 2004017030200±3%-20 to 255Zinc-Plated Steel2 hp @ 115V AC
    3 hp @ 230V AC
    3 hp @ 115V AC
    5 hp @ 230V AC
    1 hp @ 115V DC
    1 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K1300000
    100 to 2006016040200±3%-20 to 255Zinc-Plated Steel1 1/2 hp @ 115V AC
    2 hp @ 230V AC
    2 hp @ 115V AC
    3 hp @ 230V AC
    Screw TerminalNEMA 1
    4154K1700000
     
    Steel Housing—3/8 NPT Female Pipe
    30 to 125810527125±5%-30 to 210Steel2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    5 hp @ 480V AC
    Screw TerminalNEMA 1
    4154K825000000
    70 to 2504021547250±5%-30 to 210Steel2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    5 hp @ 480V AC
    Screw TerminalNEMA 1
    4154K811000000
     
    Pressure Switches with Air Exhaust Valve
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Air Compressors, Pressure Switches with Air Exhaust Valve.
    Switches with an air exhaust valve release the air between the cylinder and check valve when the compressor shuts off, reducing stress on the compressor’s motor. This extends the life of the motor and makes for an easier startup each time.
    Polycarbonate Housing and Polypropylene Housing—Switches with plastic housing stand up to corrosion.
    Steel Housing—Switches with steel housing are impact resistant.
    Reset
    Point, psi
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Min.
    Max.
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    Process Temp.
    Range, ° F
    Connection
    Material
    AC (Single Phase)
    AC (Three Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Polycarbonate Housing—1/4 NPT Female Pipe
    80 to 1006011020110±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K622000000
    95 to 1255014529145±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K62600000
     
    Polypropylene Housing—1/4 NPSF Female Pipe
    20 to 805602280±3%-20 to 255Zinc-Plated Steel2 hp @ 115V AC
    3 hp @ 230V AC
    3 hp @ 115V AC
    5 hp @ 230V AC
    1 hp @ 115V DC
    1 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K12000000
    40 to 100208020100±3%-20 to 255Zinc-Plated Steel1 1/2 hp @ 115V AC
    2 hp @ 230V AC
    2 hp @ 115V AC
    3 hp @ 230V AC
    Screw TerminalNEMA 1
    4154K1600000
    60 to 2004017030200±3%-20 to 255Zinc-Plated Steel2 hp @ 115V AC
    3 hp @ 230V AC
    3 hp @ 115V AC
    5 hp @ 230V AC
    1 hp @ 115V DC
    1 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K14000000
    100 to 2006016040200±3%-20 to 255Zinc-Plated Steel1 1/2 hp @ 115V AC
    2 hp @ 230V AC
    2 hp @ 115V AC
    3 hp @ 230V AC
    Screw TerminalNEMA 1
    4154K1800000
     
    Steel Housing—3/8 NPT Female Pipe
    30 to 125810527125±5%-30 to 210Steel2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    5 hp @ 480V AC
    Screw TerminalNEMA 1
    4154K265000000
    70 to 2504021547250±5%-30 to 210Steel2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC
    5 hp @ 480V AC
    Screw TerminalNEMA 1
    4154K261000000
     
    Pressure Switches with Air Exhaust Valve and Manual On/Off
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Air Compressors, Pressure Switches with Air Exhaust Valve and Manual On/Off.
    Switches with a manual on/off lever let you override your system, so you can keep it off for maintenance or if it will be out of use for an extended period. When you flip the lever back to on, the switch will have the setpoint and reset point it had at its last use.
    Switches with an air exhaust valve release the air between the cylinder and check valve when the compressor shuts off, reducing stress on the compressor’s motor. This extends the life of the motor and makes for an easier startup each time.
    Polycarbonate Housing—Switches with plastic housing stand up to corrosion.
    Reset
    Point, psi
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Min.
    Max.
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    Process Temp.
    Range, ° F
    Connection
    Material
    AC (Single Phase)
    AC (Three
    Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Polycarbonate Housing—1/4 NPT Female Pipe
    80 to 1006011020110±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K242000000
    95 to 1255014529145±5%-30 to 210Steel1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    4154K24600000
     

    Pressure Switches for Water Pumps

    Image of Product. Pressure Switches. Front orientation. Pressure Switches. Pressure Switches for Water Pumps.
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Water Pumps, Pressure Switches with Manual On/Off Lever.

    Pressure Switches

    Pressure Switches with

    Manual On/Off Lever

    Activate or deactivate your electric water pump based on water pressure. These switches turn your pump off when pressure increases to the set pressure and on when pressure drops to the reset pressure. All are NEMA rated to stand up to some corrosion, but they shouldn’t be used outdoors. UL listed and CSA certified, switches meet American and Canadian safety standards.
    Low-Pressure Cutoff—Switches with low-pressure cutoff turn your pump off if water pressure dips 10 psi lower than the reset pressure. This stops the system from pumping when there’s an issue in your line, such as a leak or break, to avoid flooding or other damage. These switches will also resume pump control with their previous setpoints when turned back on.
    Pressure Switches with Manual On/Off Lever—Use switches with a manual on/off lever to turn off your system for maintenance or for long periods of time. When you turn them back on, they’ll resume pump control and remember their pressure setpoints.
    Pressure Switches with Pressure Surge Protection—Switches with pressure surge protection won’t activate during brief periods of high pressure. They’re often used in systems that have frequent pressure spikes.
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Reset Point,
    psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    AC (Single Phase)
    AC (Three Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Pressure Switches
     
    1/4 NPT Female Pipe
    1 to 123 to 7412±5%2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC1/2 hp @ 32V DC
    1/2 hp @ 230V DC
    Screw TerminalNEMA 1
    41535K980000000
    3 to 355 to 101035±5%2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC1/2 hp @ 32V DC
    1/2 hp @ 230V DC
    Screw TerminalNEMA 1
    41535K96000000
    5 to 6530 to 502265±5%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC1/4 hp @ 32V DC
    1/4 hp @ 230V DC
    Screw TerminalNEMA 1
    41535K93000000
    5 to 8030 to 502280±5%2 hp @ 120V AC
    3 hp @ 240V AC
    5 hp @ 240V AC1/2 hp @ 32V DC
    1/2 hp @ 230V DC
    Screw TerminalNEMA 1
    41535K94000000
     
    Pressure Switches with Manual On/Off Lever
     
    1/4 NPSF Female Pipe
    20 to 655 to 452065±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    Screw TerminalNEMA 1
    41535K1100000
    25 to 805 to 602080±3%2 hp @ 120V AC
    3 hp @ 240V AC
    3 hp @ 120V AC
    5 hp @ 240V AC
    1/2 hp @ 120V DC
    1/2 hp @ 240V DC
    Screw TerminalNEMA 1
    41535K1200000
     
    Pressure Switches with Manual On/Off Lever and Low-Pressure Cutoff
     
    1/4 NPSF Female Pipe
    20 to 655 to 452065±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 240V AC
    1/4 hp @ 120V DC
    Screw TerminalNEMA 1
    41535K1400000
     
    Pressure Switches with Pressure Surge Protection
     
    1/4 NPSF Female Pipe
    20 to 655 to 452065±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    Screw TerminalNEMA 1
    41535K1300000
     

    Dual-Setpoint Electronic Pressure Switches with Digital Display

    Image of Product. Front orientation. Contains Inset. Pressure Switches. Dual-Setpoint Electronic Pressure Switches with Digital Display.
    Image of Specification. 4-Pole M12 Plug. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches with Digital Display.

    4-Pole

    M12

    Plug

    When these switches reach either of their two set pressures—both of which can be controlled from the display—they send digital signals to your programmable logic controller (PLC) to activate automated controls. This means you could turn on a pump at one setpoint if pressure drops too low and open a valve at another if pressure rises too high. These switches could also be used to signal an alarm before switching off a pump. For remote control and monitoring from your PLC or PC, connect an IO Link controller (not included). You’ll also need to set one of the outputs to use IO Link instead of a PNP or NPN signal.
    Change your setpoint, reset point, scaling, and other settings using the display’s buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point. The head rotates, so you can view the display from the best angle. To reduce stress on pipes in your pressure system, secure these switches against a wall or other structure with a mounting bracket (sold separately). Use these switches with an M12 cable (sold separately) to quickly connect and disconnect them.
    All are rated IP65 and IP67, so they seal out dust and water from washdowns and brief submersion. UL and C-UL listed, all meet U.S. and Canadian safety standards.
    Configurable
    Digital Output
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Signal
    Output
    Communication
    Protocol
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection Material
    Measurement Unit
    For Use With
    Each
    M12 Connection with 4 Poles
     
    1/4 NPT Male Pipe
    0 to 14Adjustable145PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Inches of Mercury, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water3167K310000000
    0 to 36Adjustable290PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water3167K32000000
    0 to 360Adjustable1,015PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N11000000
    0 to 1,450Adjustable1,810PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N12000000
    0 to 3,600Adjustable7,250PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N13000000
    0 to 5,800Adjustable11,580PNP, NPNIO-Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N14000000
     
    Accessories for Pressure Switches

    Economy Pressure Switches

    Use these switches for applications that need reliable switching but don’t require high accuracy. When a set pressure is reached, they turn equipment on and off, signal automatic controls, or trigger alarms. These are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed). All meet safety standards.
    Quick-Disconnect-Terminal Wire Connection
    Image of Product. Front orientation. Contains Annotated. Style A. Economy Pressure Switches.
    Style
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Certification
    Each
    1/4 Threaded NPT Male Pipe
     
    External Adjustment
    A1 1/2 to 3 1/21.1600750±8%15 amp @ 250V AC-30 to 185BrassAir, Diesel Fuel, Hydraulic Fluid, WaterC-UL Listed, CE Marked, UL Listed
    8207N11000000
    A3 to 403.5600750±3%25 amp @ 250V AC-30 to 185BrassAir, Diesel Fuel, Hydraulic Fluid, WaterC-UL Listed, CE Marked, UL Listed
    8207N1300000
    A30 to 15017.5600750±425 amp @ 250V AC-30 to 185BrassAir, Diesel Fuel, Hydraulic Fluid, WaterC-UL Listed, CE Marked, UL Listed
    8207N1500000
    A100 to 50075600750±5%25 amp @ 250V AC-30 to 185BrassAir, Diesel Fuel, Hydraulic Fluid, WaterC-UL Listed, CE Marked, UL Listed
    8207N1700000
     
    Screw-Terminal Wire Connection
    Image of Product. Front orientation. Contains Annotated. Style A. Economy Pressure Switches.
    Style
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Certification
    Each
    1/4 Threaded NPT Male Pipe
     
    External Adjustment
    A1 1/2 to 3 1/21.1600750±8%15 amp @ 250V AC-30 to 185BrassAir, Diesel Fuel, Hydraulic Fluid, WaterC-UL Listed, CE Marked, UL Listed
    8207N12000000
     
    Spade-Terminal Wire Connection
    Image of Product. Front orientation. Contains Annotated. Style B. Economy Pressure Switches.
    Style
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Certification
    Each
    1/8 Threaded NPT Male Pipe
     
    External Adjustment
    B2 to 100.9250750±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterUL Recognized Component
    3460K21000000
    B6 to 302.5250750±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterUL Recognized Component
    3460K4100000
    B20 to 12010250750±5%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterUL Recognized Component
    3460K6100000
     

    Electronic Pressure Switches

    When these switches reach a set pressure, they send electronic signals to your programmable logic controller (PLC) to activate automated controls or alarms. Easily adjust the setpoint by twisting the external ring. An indicating pointer and incremental markings make sure adjustments are precise. When you have your setpoint, tighten the locking ring to prevent unintentional changes. Pair these switches with an M12 socket to quickly connect and disconnect them.
    Rated IP67, these switches seal out dust and water from temporary submersion. All are UL and C-UL listed as well as CE marked, which means they meet U.S., Canadian, and European safety standards.
    1 Circuit Controlled—1 Off (Normally Open)
    Image of Product. Front orientation. Pressure Switches. Electronic Pressure Switches, 1 Circuit Controlled.
    Image of Attribute. Front orientation. Electronic Pressure Switches.

    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Signal
    Output
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    M12 Connection with 4 Pins
     
    1/4 BSPP Male Pipe
    7.5 to 1452.9360360PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N190000000
    11 to 3637.2870870PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N23000000
    44 to 1,450292,9002,900PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N22000000
    109 to 3,625725,8005,800PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N21000000
    175 to 5,8001168,7008,700PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N24000000
     
    BSPP to NPT Thread Adapter
    2 Circuits Controlled—1 Off (Normally Open) and 1 On (Normally Closed)
    Image of Product. Front orientation. Pressure Switches. Electronic Pressure Switches, 2 Circuits Controlled.
    Image of Attribute. Front orientation. Electronic Pressure Switches.

    Switches for two circuits function like single pole, double throw (SPDT) switches. When the switches reach the setpoint, they turn one circuit from off to on (normally open) and another from on to off (normally closed). They have an adjustable reset, which means you can control the amount of pressure change before the switch resets. This pressure difference is commonly referred to as deadband and differential. Use the second external ring to change the reset point anywhere along the setpoint range.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Signal
    Output
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    M12 Connection with 4 Pins
     
    1/4 NPT Male Pipe
    7.5 to 145Adjustable360360PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N110000000
    75 to 1,450Adjustable2,9002,900PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N12000000
    290 to 5,800Adjustable8,7008,700PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N13000000
     
    1/4 BSPP Male Pipe
    7.5 to 145Adjustable360360PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N14000000
    18 to 363Adjustable870870PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N18000000
    75 to 1,450Adjustable2,9002,900PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N16000000
    181 to 3,625Adjustable5,8005,800PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N15000000
    290 to 5,800Adjustable8,7008,700PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N17000000
     
    BSPP to NPT Thread Adapter

    Electronic Pressure Switches for Compressed Air

    Image of Product. Front orientation. Pressure Switches. Electronic Pressure Switches for Compressed Air.
    With a set pressure range that works for most air systems, these switches send signals when your air system reaches a set pressure to your programmable logic controller (PLC) to activate automated controls and alarms. All meet at least one American, Canadian, or European safety standard.
    Monitor your pressure on the display and change your setpoint, reset point, scaling, and other settings using the buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point.
    1 Configurable Output—Switches with a configurable output give you the flexibility to choose between PNP, NPN, or IO Link. IO Link lets you remotely control and monitor switches from your PLC or PC when you connect an IO Link controller (not included).
    IP65 Enclosure Rating—IP65 rated switches protect from dust and light rinsing.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    Wire
    Connection
    For Use With
    Enclosure
    Rating
    Each
    PNP Signal Output
     
    1/8 NPT Male Threaded Pipe
    0 to 145Adjustable145±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP40
    3167K18000000
     
    1/4" Female Push to Connect Tube
    0 to 145Adjustable145±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP40
    3167K2100000
     
    NPN Signal Output
     
    1/8 NPT Male Threaded Pipe
    0 to 145Adjustable145±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP40
    3167K1700000
     
    1/4" Female Push to Connect Tube
    0 to 145Adjustable145±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP40
    3167K1900000
     
    1 Configurable Output—PNP, NPN, IO-Link
     
    1/8 NPT Male Threaded Pipe
    0 to 145Adjustable145±0.2%35 mA @ 30V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP65
    3167K41000000
     
    1/8 BSPT Male Threaded Pipe
    0 to 145Adjustable145±0.2%35 mA @ 30V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP65
    3167K42000000
     
    M5 x 0.8 mm Female Pipe
    0 to 145Adjustable145±0.2%35 mA @ 30V DC25 to 120Nickel-Plated BrassWire LeadsAir, Argon, NitrogenIP65
    3167K44000000
     
    Square Panel-Mount Brackets

    Hazardous Location Pressure Switches

    Image of Product. Style A. Front orientation. Pressure Switches. Hazardous Location Pressure Switches, Wire Lead Connection, Style A.
    Image of Product. Style B. Front orientation. Pressure Switches. Hazardous Location Pressure Switches, Wire Lead Connection, Style B.

    Style

    A

    Style B

    Built with an explosion-proof enclosure to meet NEMA 7 and 9 standards for hazardous locations, these switches were tested and verified by UL and CSA for use where explosive liquids, dust, and gas are present. When they reach the set pressure, they power equipment, signal controls, or trigger alarms. They’re single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed). In addition to being UL listed and CSA certified, these switches are CE marked, so they also meet European safety standards.
    All switches are IP and NEMA rated for use outdoors and protection from some corrosion, dust, and spraying water.
    Wire Lead Connection
    Image of Product. Style A. Front orientation. Pressure Switches. Hazardous Location Pressure Switches, Wire Lead Connection, Style A.
    Image of Product. Style B. Front orientation. Pressure Switches. Hazardous Location Pressure Switches, Wire Lead Connection, Style B.

    Style

    A

    Style B

    IP67 Enclosure Rating and NEMA 4X Enclosure Rating—IP67 and NEMA 4X rated switches seal out water from temporary submersion and have increased protection against corrosion, similar to 304 stainless steel.
    Style
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure Rating
    Hazardous Location Rating
    Certification
    Each
    1/4 Threaded NPT Male Pipe
     
    Internal Adjustment
    A8 to 605601,000±5%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K710000000
    A10 to 10091001,000±5%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K72000000
    A20 to 200162001,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K73000000
    A50 to 500605005,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K74000000
    A100 to 1,000871,0005,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K75000000
    A200 to 2,0001652,0005,000±2%5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 190316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP67, NEMA 4X, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K76000000
     
    1/2 Threaded NPT Female Pipe
     
    Internal Adjustment
    B6 to 302301,000±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K61000000
    B12 to 602601,000±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K62000000
    B20 to 1003.51001,000±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K63000000
    B40 to 2006.52001,000±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K64000000
    B80 to 400114001,600±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, WaterIP66, NEMA 4, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    CE Marked, CSA Certified, UL Listed
    46985K65000000
     

    Adjustable-Reset Pressure Switches

    Choose when these switches reset to control the pressure range between when they activate and deactivate, commonly referred to as deadband and differential. You can adjust their reset point anywhere along the setpoint range. When they reach the set pressure, these switches power equipment, signal controls, or trigger alarms. They’re single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). UL listed and CSA certified, all meet American and Canadian safety standards. Those that are CE marked meet European safety standards. All protect against some corrosion.
    Pressure Switches
    Image of Product. Front orientation. Pressure Switches. Adjustable-Reset Pressure Switches.
    IP66 Enclosure Rating and NEMA 4X Enclosure Rating—NEMA 4X and IP66 rated switches can be used in dirty and wet areas exposed to washdowns. NEMA 4X switches also stand up to weather and have increased protection against corrosion, similar to 304 stainless steel.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    Screw-Terminal Wire Connection
     
    1/4 NPT Female Pipe
    2 1/2 to 13Adjustable15500±1%10 amp @ 125V AC
    10 amp @ 250V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Argon, Diesel Fuel, Gasoline, Inert Gas, Natural Gas, Nitrogen, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, FM Approved, UL Listed
    6440N110000000
    3 to 27Adjustable30500±1%10 amp @ 125V AC
    10 amp @ 250V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Argon, Diesel Fuel, Gasoline, Inert Gas, Natural Gas, Nitrogen, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, FM Approved, UL Listed
    6440N12000000
    5 to 54Adjustable60500±1%10 amp @ 125V AC
    10 amp @ 250V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Argon, Diesel Fuel, Gasoline, Inert Gas, Natural Gas, Nitrogen, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, FM Approved, UL Listed
    6440N13000000
    10 to 90Adjustable1001,000±1%10 amp @ 125V AC
    10 amp @ 250V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Argon, Diesel Fuel, Gasoline, Inert Gas, Natural Gas, Nitrogen, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, FM Approved, UL Listed
    6440N14000000
    18 to 180Adjustable2001,000±1%10 amp @ 125V AC
    10 amp @ 250V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Argon, Diesel Fuel, Gasoline, Inert Gas, Natural Gas, Nitrogen, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, FM Approved, UL Listed
    6440N15000000
    45 to 360Adjustable4002,400±1%10 amp @ 125V AC
    10 amp @ 250V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Argon, Diesel Fuel, Gasoline, Inert Gas, Natural Gas, Nitrogen, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, FM Approved, UL Listed
    6440N16000000
    75 to 540Adjustable6002,400±1%10 amp @ 125V AC
    10 amp @ 250V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Argon, Diesel Fuel, Gasoline, Inert Gas, Natural Gas, Nitrogen, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, FM Approved, UL Listed
    6440N17000000
     
    On/Off Indicator Pressure Switches
    Image of Product. Front orientation. Pressure Switches. Adjustable-Reset Pressure Switches, On/Off Indicator Pressure Switches.
    Switches with an on/off indicator tell you the status of your equipment, letting you monitor your equipment even when it’s out of sight.
    NEMA 1 Enclosure Rating—NEMA 1 rated switches should only be used indoors.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    Screw-Terminal Wire Connection
     
    1/4 NPT Male Pipe
    1/8 to 15Adjustable1515±1%10 amp @ 120V AC
    10 amp @ 240V AC
    35 to 180BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 1
    CSA Certified, UL Listed
    4941K52000000000
    2 to 60Adjustable6060±1%10 amp @ 120V AC
    10 amp @ 240V AC
    35 to 180BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 1
    CSA Certified, UL Listed
    4941K5300000000
    5 to 100Adjustable100100±1%10 amp @ 120V AC
    10 amp @ 240V AC
    35 to 180BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 1
    CSA Certified, UL Listed
    4941K5400000000
    5 to 150Adjustable150150±1%10 amp @ 120V AC
    10 amp @ 240V AC
    35 to 180BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 1
    CSA Certified, UL Listed
    4941K5500000000
    10 to 200Adjustable200200±1%10 amp @ 120V AC
    10 amp @ 240V AC
    35 to 180BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 1
    CSA Certified, UL Listed
    4941K5600000000
    10 to 300Adjustable300300±1%10 amp @ 120V AC
    10 amp @ 240V AC
    35 to 180BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 1
    CSA Certified, UL Listed
    4941K5700000000
     

    Adjustable-Reset Pressure Switches with Digital Display

    Image of Product. Front orientation. Contains Annotated. Pressure Switches. Adjustable-Reset Pressure Switches with Digital Display.
    Kick off automated controls, signal alarms, or activate equipment based on pressure changes while checking the pressure, setpoint, and reset point on the display. The adjustable reset point lets you control the amount of pressure change, also known as deadband and differential, before the switch resets. Adjust it anywhere within the setpoint range. Turn the external adjustment knob by hand to set pressure quickly. These are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    To power the display, these switches need a separate electrical input from the one used for switching.
    These switches are IP and NEMA rated, so they’re dust tight and protected against water from washdowns and weather, as well as sprays of oil and coolant.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Wire
    Connection
    Connection
    Material
    For Use With
    Enclosure Rating
    Each
    110V AC Input Voltage
     
    1/4 NPT Male Pipe
    3 to 60Adjustable60120±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T210000000
    5 to 100Adjustable100200±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T22000000
    10 to 200Adjustable200400±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T23000000
    150 to 3,000Adjustable3,0004,500±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T24000000
     
    24V DC Input Voltage
     
    1/4 NPT Male Pipe
    10 to 200Adjustable200400±0.5%10 amp @ 250V AC
    30 amp @ 30V DC
    -20 to 160Screw Terminal316 Stainless SteelAir, Hydraulic Fluid, WaterIP66, NEMA 4X, NEMA 13
    7564T25000000
     

    Multiport Pressure Switches for Air Compressors

    Image of Product. Front orientation. Pressure Switches. Multiport Pressure Switches for Air Compressors, Pressure Switches with Air Exhaust Valve.
    Image of Product. Front orientation. Pressure Switches. Multiport Pressure Switches for Air Compressors, Pressure Switches with Air Exhaust Valve and Manual On/Off.

    Pressure Switches with

    Air Exhaust Valve

    Pressure Switches with

    Air Exhaust Valve and

    Manual On/Off

    With multiple ports, these switches maintain the air pressure of your electric air compressor, while also including ports for up to three air-powered devices, reducing the complexity of your air system setup. These switches turn off the compressor when it reaches the set pressure and on when the pressure drops to the reset point. They have an air exhaust valve, so when they shut off, they automatically release air between the compressor’s cylinder and check valve. This reduces stress on the motor to extend its life and makes for easier startups. All are NEMA rated to protect from dirt and stand up to some corrosion, but they shouldn’t be used outdoors. UL listed, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
    Manual On/Off Lever—Switches with a manual on/off lever let you turn off your system for maintenance or extended periods of time. When you flip the lever back on, the switch will automatically have the setpoint and reset point from its last use.
    Max. Horsepower
    Pressure Set
    Point Range, psi
    Reset Point,
    psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Accuracy
    AC (Single Phase)
    AC (Three Phase)
    DC
    Wire
    Connection
    Enclosure
    Rating
    Each
    Pressure Switches with Air Exhaust Valve
     
    1/4 NPSC Pipe
    70 to 15040 to 12030150±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 120V DC
    1/4 hp @ 240V DC
    Screw TerminalNEMA 1
    6530N13000000
    100 to 20060 to 16040200±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 120V DC
    1/4 hp @ 240V DC
    Screw TerminalNEMA 1
    6530N1100000
     
    Pressure Switches with Air Exhaust Valve and Manual On/Off
     
    1/4 NPSC Pipe
    70 to 15040 to 12030150±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 120V DC
    1/4 hp @ 240V DC
    Screw TerminalNEMA 1
    6530N1400000
    100 to 20060 to 16040200±3%1 1/2 hp @ 120V AC
    2 hp @ 240V AC
    2 hp @ 120V AC
    3 hp @ 240V AC
    1/4 hp @ 120V DC
    1/4 hp @ 240V DC
    Screw TerminalNEMA 1
    6530N1200000
     
    Plugs

    Dual-Setpoint Electronic Pressure Switches for Compressed Air

    Compatible with most air systems, these switches send digital signals to a programmable logic controller (PLC) to trigger separate processes when they reach either of their two set pressures. For example, they’ll activate a compressor if the pressure is too low or a relief valve if the pressure is too high. Or use them to signal an alarm before switching off a compressor. Some of these switches also work with liquids and gases, so they can be built into hydraulic systems and wet or humid environments, such as cleaning lines.
    Monitor your pressure on the display and change your setpoints, reset points, scaling, and other settings using the buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point. Add a panel-mount bracket (sold separately) to mount these switches to a control panel for easy viewing and adjusting.
    Rated IP65, they seal out dust and water from washdowns. Switches are UL and C-UL recognized components and CE marked to meet American, Canadian, and European safety standards.
    Wire Lead Connection
    Image of Product. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches for Compressed Air.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Signal
    Output
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
     
    External Adjustment
    15 to 150Adjustable150215PNP±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Inert Gas, NitrogenIP65
    C-UL Recognized Component, CE Marked, UL Recognized Component
    9330N110000000
     
    1/4 Threaded NPT Male Pipe
     
    External Adjustment
    15 to 150Adjustable150290PNP±0.2%35 mA @ 24V DC25 to 120304 Stainless SteelAir, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, WaterIP65
    C-UL Recognized Component, CE Marked, UL Recognized Component
    9330N12000000
    15 to 300Adjustable300580PNP±0.2%35 mA @ 24V DC25 to 120304 Stainless SteelAir, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, WaterIP65
    C-UL Recognized Component, CE Marked, UL Recognized Component
    9330N13000000
     
    Square Panel-Mount Brackets

    Dual-Setpoint Electronic Pressure Switches

    Send two digital signals to your programmable logic controller (PLC) to trigger different processes—these switches activate at two set pressures. For example, you can turn on one pump to empty a tank when the pressure rises too high and another to fill the tank when the pressure drops too low. They could also be used to signal an alarm before switching off a pump. Twist the external rings to adjust each setpoint. Indicator markings and pointer make precise adjustments in the field easy. Avoid accidental changes to the setpoints by tightening the setpoint locking ring. Pair these switches with an M12 socket to quickly connect and disconnect them.
    All switches are rated IP67, so they’re protected from dust and temporary submersion. UL and C-UL listed as well as CE marked, all meet U.S., Canadian, and European safety standards.
    M12 Connection with 4 Poles
    Image of Product. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches.
    Image of Attribute. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Signal
    Output
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/4 Threaded BSPP Male Pipe
     
    External Adjustment
    4 1/2 to 1452.9360360PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    C-UL Listed, CE Marked, UL Listed
    4064N260000000
    45 to 1,450292,9002,900PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    C-UL Listed, CE Marked, UL Listed
    4064N27000000
    109 to 3,625725,8005,800PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    C-UL Listed, CE Marked, UL Listed
    4064N25000000
    174 to 5,8001168,7008,700PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    C-UL Listed, CE Marked, UL Listed
    4064N28000000
     
    BSPP to NPT Thread Adapter

    Dual-Setpoint Pressure Switches

    Trigger two different automated processes, each with their own set pressure. These switches could, for example, turn one pump on to empty a tank when the pressure gets too high and another to fill the tank when the pressure drops too low. Or use them to trigger an alarm before turning off a pump. These have two single pole, double throw (SPDT) switches and can switch each circuit from off to on (normally open) or on to off (normally closed).
    NEMA 4X and IP66 rated, these switches seal out dust and water from washdowns and weather, and they resist corrosion. They are UL listed, CSA certified, and CE marked to meet American, Canadian, and European safety standards.
    Screw-Terminal Wire Connection
    Image of Product. Front orientation. Pressure Switches. Dual-Setpoint Pressure Switches.
    Pressure Set Point Range
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/4 Threaded NPT Female Pipe
     
    Internal Adjustment
    4.5 in. H₂O to 30 in. H₂O4.5 in. H₂O30 in. H₂O20±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, UL Listed
    46025K620000000
    3 psi to 13 psi1.5 psi15 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, UL Listed
    4436N11000000
    5 psi to 27 psi3 psi30 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, UL Listed
    4436N12000000
    9 psi to 54 psi5 psi60 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, UL Listed
    4436N13000000
    15 psi to 90 psi9.5 psi100 psi1,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, UL Listed
    4436N14000000
    30 psi to 180 psi16 psi200 psi1,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, UL Listed
    4436N15000000
    60 psi to 360 psi32 psi400 psi2,400±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, UL Listed
    4436N16000000
    90 psi to 540 psi46 psi600 psi2,400±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    500 mA @ 125V DC
    250 mA @ 250V DC
    0 to 150316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    CE Marked, CSA Certified, UL Listed
    4436N17000000
     

    Manual-Reset Pressure Switches

    Used as a safety control, these switches must be manually reset each time they hit the set pressure, so you can inspect equipment before it restarts. When pressure rises too high, they activate alarms or stop processes. Push the button on the top to reset. Switches are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    NEMA 4X and IP66 rated, these switches resist corrosion and seal out dust and water from washdowns and weather. All meet at least one American, Canadian, or European safety standard.
    Screw-Terminal Wire Connection
    Image of Product. Front orientation. Pressure Switches. Manual-Reset Pressure Switches.
    Pressure Set
    Point Range, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/4 Threaded NPT Female Pipe
     
    Internal Adjustment
    2 1/4 to 1515500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    C-UL Listed, CE Marked, CSA Certified, CSA-US Certified, UL Listed
    9250N110000000
    4 1/2 to 3030500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    C-UL Listed, CE Marked, CSA Certified, CSA-US Certified, UL Listed
    9250N12000000
    9 to 6060500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    C-UL Listed, CE Marked, CSA Certified, CSA-US Certified, UL Listed
    9250N13000000
    15 to 1001001,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    C-UL Listed, CE Marked, CSA Certified, CSA-US Certified, UL Listed
    9250N14000000
    30 to 2002001,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    C-UL Listed, CE Marked, CSA Certified, CSA-US Certified, UL Listed
    9250N15000000
    60 to 4004002,400±1%15 amp @ 125V AC
    15 amp @ 250V AC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    C-UL Listed, CE Marked, CSA Certified, CSA-US Certified, UL Listed
    9250N16000000
    90 to 6006002,400±1%15 amp @ 125V AC
    15 amp @ 250V AC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    C-UL Listed, CE Marked, CSA Certified, CSA-US Certified, UL Listed
    9250N17000000
    150 to 1,0001,00012,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    C-UL Listed, CE Marked, CSA Certified, CSA-US Certified, UL Listed
    9250N18000000
    450 to 3,0003,00012,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    C-UL Listed, CE Marked, CSA Certified, CSA-US Certified, UL Listed
    9250N19000000
     

    Pressure Switches for Oxygen

    Cleaned to ASTM G93 requirements and then bagged, these switches meet the strict cleaning standards required for oxygen service lines. Removing all contaminants extends the life of the switch and helps maintain a safe environment.
    When a set pressure is reached, these switches can turn equipment on and off, activate automated controls, or signal alarms. They have an internal setpoint adjustment with a sliding cover to prevent accidental setting changes. They’re single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed).
    NEMA rated, they seal out dust and water from washdowns and the weather. These switches also meet UL 508, are CE marked, and are UL and C-UL recognized components, so they meet American, Canadian, and European safety standards.
    Wire Lead Connection
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Oxygen.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
    4 to 503.51,0003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K120000000
    10 to 15061,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K14000000
    30 to 600342,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K16000000
     
    1/4 Threaded NPT Male Pipe
    100 to 1,5001208,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K17000000
    180 to 3,0002258,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K18000000
    400 to 4,7003508,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K19000000
    4,000 to 7,50067510,00012,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K21000000
     

    Sanitary Pressure and Vacuum Switches

    Image of Product. Front orientation. Pressure Switches. Sanitary Pressure and Vacuum Switches.
    When these 3-A certified switches reach a set pressure or vacuum, they trigger controls and alarms in food-processing, pharmaceutical, and biotech lines. They have a sleeve to shield internal parts from water and contaminants. Their surfaces are polished and their seams are continuously welded, so cleaning is easy and there’s little room for bacteria to grow. Made of 316 stainless steel, these switches stand up to harsh cleaners and sanitizers without rusting. Rated IP67 and NEMA 6, they’re dust tight and protected from washdowns and temporary submersion.
    They connect using the same quick-clamp fittings (also known as tri-clamp fittings) that are common in sanitary lines, because they’re easy to take apart for cleaning. This end has a diaphragm that protects from corrosion and covers threads to keep them clean. The diaphragm is filled with 99.5% pure USP food-grade glycerin, reducing the risk of contamination if the diaphragm fails. The serial number is laser etched on the diaphragm to reduce crevices.
    Twist the adjustable setpoint ring to make quick changes. These switches are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    All have a material certificate with a traceable lot number and a calibration certificate traceable to NIST.
    Setpoint
    Pressure,
    psi
    Vacuum,
    in. Hg
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    Wire Lead Connection
     
    For 1 1/2" OD Quick Clamp Tube
    0 to 150 to 303151,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelArgon, Beverage, Diesel Fuel, Food, Gasoline, Hydraulic Fluid, Inert Gas, Natural Gas, Nitrogen, Oil, Oxygen, WaterIP67, NEMA 6
    UL Listed
    8834N2010000000
     
    For 2" OD Quick Clamp Tube
    0 to 150 to 303151,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelArgon, Beverage, Diesel Fuel, Food, Gasoline, Hydraulic Fluid, Inert Gas, Natural Gas, Nitrogen, Oil, Oxygen, WaterIP67, NEMA 6
    UL Listed
    8834N206000000
     

    Pressure Switches for Sump Pumps

    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Sump Pumps.
    Since these switches activate on increasing pressure caused by rising water levels, they have no floats to catch on sump pit walls. Use them to replace an existing switch, or pair them with a plug-in activated pump to control when the pump activates.
    Wire Lead Connection—Switch with wire leads can be connected to a three-pronged plug or wired directly to a power source.
    Electircal
    Voltage,
    V AC
    Current,
    amp
    Temp. Range,
    ° F
    Wire
    Connection
    Connection
    No. of
    Blades
    Cord Lg.,
    ft.
    Each
    1201035 to 120Straight Blade3189326T110000000
    2401035 to 120Wire Leads89326T1200000

    Sanitary Pressure Switches

    Image of Product. Front orientation. Contains Annotated. Pressure Switches. Sanitary Pressure Switches.
    3-A certified, these food-safe switches trigger automated controls and alarms when food-processing, pharmaceutical, and biotech lines reach a set pressure. These switches have many features that make them safe for sanitary environments because they reduce the space where bacteria could grow. A sleeve shields internal parts from water and other contaminants. Polished surfaces and smoothly welded seams make cleaning easier. Made of 316 stainless steel, they stand up to harsh cleaners and sanitizers without rusting. Rated IP67 and NEMA 6, they’re dust tight and withstand washdowns and temporary submersion.
    Connect them to your line with the same quick-clamp fittings (also known as tri-clamp fittings) that are common on sanitary lines since they’re easy to take apart for cleaning. The quick-clamp end has a diaphragm that protects the switches from corrosive material and covers threads to keep them clean. The diaphragm is filled with 99.5% pure USP food-grade glycerin, which keeps the switch clean if the diaphragm fails. It’s also laser etched with the serial number to reduce crevices.
    Twist the adjustable setpoint ring to make quick changes. These switches are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    All have a material certificate with traceable lot number and a calibration certificate traceable to NIST.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    Wd.
    For Use With
    Enclosure
    Rating
    Food Industry Std.
    Certification
    Each
    Wire Lead Connection
     
    For 1 1/2" OD Quick Clamp Tube
    6 to 303301,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N2020000000
    8 to 605601,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N203000000
    10 to 10041001,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N204000000
    20 to 200162001,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N205000000
     
    For 2" OD Quick Clamp Tube
    6 to 303301,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2 1/2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N207000000
    8 to 606601,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2 1/2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N208000000
    10 to 10041001,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2 1/2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N209000000
    20 to 200162001,000±5%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless Steel2 1/2"Beverage, FoodIP67, NEMA 6
    3-A Certified 74-07
    UL Listed
    8834N211000000
     

    Pressure Switches for SMC Modular Filter/Regulator/Lubricators (FRLs)

    Image of ProductInUse. Front orientation. Contains Annotated. Pressure Switches. Pressure Switches for SMC Modular Filter/Regulator/Lubricators (FRLs).
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for SMC Modular Filter/Regulator/Lubricators (FRLs).
    Connect these switches to your SMC filter/regulator/lubricator (FRL) to monitor air pressure and send signals to controllers or other equipment. When they reach a set pressure, they can turn machines on or off, sound alarms, or trigger automated controls. These switches are single pole, single throw (SPST) and normally open, so they’re dependable and simple to use. Choose a switch in the same series as your FRL.
    Joiner Clamps—Joiner clamps (sold separately) create compact, airtight connections that are easy to swap out. They come with mounting brackets.
    Pressure Switches
    Joiner Clamps
    Overall
    For Mfr.
    Series
    For Pipe
    Size
    Input Voltage
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Wd.
    Ht.
    Includes
    Enclosure
    Rating
    Each
    Each
    AC20-D1/4
    100V AC, 100V DC15 to 8711.6100145±8.3%20 mA @ 100V AC
    20 mA @ 100V DC
    40 mA @ 48V AC
    40 mA @ 48V DC
    50 mA @ 24V AC
    50 mA @ 24V DC
    25 to 1401 1/8"3 1/8"Mounting BracketIP40
    8713N110000008210N11100000
    AC30-D1/4
    100V AC, 100V DC15 to 8711.6100145±8.3%20 mA @ 100V AC
    20 mA @ 100V DC
    40 mA @ 48V AC
    40 mA @ 48V DC
    50 mA @ 24V AC
    50 mA @ 24V DC
    25 to 1401 1/4"3 3/8"Mounting BracketIP40
    8713N12000008210N1120000
    AC30-D3/8
    100V AC, 100V DC15 to 8711.6100145±8.3%20 mA @ 100V AC
    20 mA @ 100V DC
    40 mA @ 48V AC
    40 mA @ 48V DC
    50 mA @ 24V AC
    50 mA @ 24V DC
    25 to 1401 1/4"3 3/8"Mounting BracketIP40
    8713N13000008210N1120000
    AC40-D3/8
    100V AC, 100V DC15 to 8711.6100145±8.3%20 mA @ 100V AC
    20 mA @ 100V DC
    40 mA @ 48V AC
    40 mA @ 48V DC
    50 mA @ 24V AC
    50 mA @ 24V DC
    25 to 1401 1/2"3 11/16"Mounting BracketIP40
    8713N14000008210N1130000
    AC40-D1/2
    100V AC, 100V DC15 to 8711.6100145±8.3%20 mA @ 100V AC
    20 mA @ 100V DC
    40 mA @ 48V AC
    40 mA @ 48V DC
    50 mA @ 24V AC
    50 mA @ 24V DC
    25 to 1401 1/2"3 11/16"Mounting BracketIP40
    8713N15000008210N1130000