McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    293 Products

    Elbow Air Flow Control Valves

    Mount these valves directly to cylinder ports, eliminating additional tubing or piping between the cylinder and valve for better control and consistency than inline valves. Flow control valves control the speed of air-powered equipment by adjusting the volume of airflow. They control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    NPT Male Inlet × NPT Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, NPT Male Inlet × NPT Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves, Meter Out.

    Meter Out

    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 87
    psi, scfm
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Brass Body
    1/8
    1/8
    0.2604.141500 to 200NutExiting Cylinder (Meter Out)45045K51000000
    1/4
    1/4
    0.75039.861500 to 200NutExiting Cylinder (Meter Out)45045K5200000
    3/8
    3/8
    0.84043.971500 to 200NutExiting Cylinder (Meter Out)45045K5300000
    1/2
    1/2
    2.1201001500 to 200NutExiting Cylinder (Meter Out)45045K5400000
     
    NPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, NPT Male Inlet × Push-to-Connect Female Outlet, Brass Body.
    Image of Product. Front orientation. Air Flow Control Valves. Elbow Air Flow Control Valves, NPT Male Inlet × Push-to-Connect Female Outlet, Nylon Body.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, NPT Male Inlet × Push-to-Connect Female Outlet, Polybutylene Body.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves, Meter Out.

    Brass Body

    Nylon Body

    Polybutylene Body

    Meter Out

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 73
    psi, scfm
    Flow Rate @ 87
    psi, scfm
    Flow Rate @ 100
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Min.
    Max.
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Brass Body
    1/8
    1/4"0.28043.971500 to 200NutExiting Cylinder (Meter Out)45045K56000000
    1/4
    1/4"0.51039.861500 to 200NutExiting Cylinder (Meter Out)45045K5700000
    1/4
    3/8"0.6204.141500 to 200NutExiting Cylinder (Meter Out)45045K5800000
    3/8
    3/8"0.78043.971500 to 200NutExiting Cylinder (Meter Out)45045K5900000
     
    Nylon Body
    1/8
    1/8"0.200.114535 to 155DialExiting Cylinder (Meter Out)45045K2800000
    1/8
    5/32"0.207.514535 to 155DialExiting Cylinder (Meter Out)45045K300000
    1/8
    1/4"Not Rated07.514535 to 155DialExiting Cylinder (Meter Out)45045K3200000
    1/4
    1/4"Not Rated013.914535 to 155DialExiting Cylinder (Meter Out)45045K3300000
     
    Polybutylene Body
    1/8
    1/8"0.1203.514532 to 140DialExiting Cylinder (Meter Out)62005K22100000
    1/8
    5/32"0.1504.81500 to 175DialExiting Cylinder (Meter Out)62005K22200000
    1/8
    1/4"0.1906.11500 to 175DialExiting Cylinder (Meter Out)62005K22400000
    1/8
    5/16"0.1906.11500 to 175DialExiting Cylinder (Meter Out)62005K22500000
    1/4
    5/32"0.22071500 to 175DialExiting Cylinder (Meter Out)62005K23100000
    1/4
    1/4"0.39012.51500 to 175DialExiting Cylinder (Meter Out)62005K23300000
    1/4
    5/16"0.39012.51500 to 175DialExiting Cylinder (Meter Out)62005K23400000
    1/4
    3/8"0.39012.51500 to 175DialExiting Cylinder (Meter Out)62005K23500000
    3/8
    1/4"0.56017.91500 to 175DialExiting Cylinder (Meter Out)62005K25100000
    3/8
    5/16"0.67021.41500 to 175DialExiting Cylinder (Meter Out)62005K25200000
    3/8
    3/8"0.67024.91500 to 175DialExiting Cylinder (Meter Out)62005K25300000
    3/8
    1/2"Not Rated03514532 to 140DialExiting Cylinder (Meter Out)62005K71100000
    1/2
    5/16"Not Rated052.514532 to 140DialExiting Cylinder (Meter Out)62005K71200000
    1/2
    3/8"1.33042.51500 to 175DialExiting Cylinder (Meter Out)62005K26100000
    1/2
    1/2"1.44042.314532 to 140DialExiting Cylinder (Meter Out)62005K26200000
     
    UNF Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, UNF Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves, Meter Out.

    Meter Out

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 100
    psi, scfm
    Inlet Thread
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Nylon Body
    10-32
    1/8"0.0914535 to 155DialExiting Cylinder (Meter Out)45045K27000000
    10-32
    5/32"0.0902.714535 to 155DialExiting Cylinder (Meter Out)45045K2900000
    10-32
    1/4"0.2503.014535 to 155DialExiting Cylinder (Meter Out)45045K3100000
     
    Polybutylene Body
    10-32
    1/8"0.0802.61500 to 175DialExiting Cylinder (Meter Out)62005K21100000
    10-32
    5/32"0.0802.61500 to 175DialExiting Cylinder (Meter Out)62005K21200000
     
    BSPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, BSPT Male Inlet × Push-to-Connect Female Outlet, Polybutylene Body.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, BSPT Male Inlet × Push-to-Connect Female Outlet, Polybutylene Body with Pressure-Release Button.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves, Meter Out.

    Polybutylene Body

    Polybutylene

    Body with

    Pressure-Release

    Button

    Meter Out

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Pressure-Release Button—Valves with a pressure-release button allow you to exhaust any trapped air pressure from the system after shut down.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 73
    psi, scfm
    Flow Rate @ 100
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    1/8
    40.1504.81500 to 175DialExiting Cylinder (Meter Out)62005K521000000
    1/8
    60.1906.11500 to 175DialExiting Cylinder (Meter Out)62005K52200000
    1/8
    80.1906.11500 to 175DialExiting Cylinder (Meter Out)62005K52300000
    1/4
    40.22071500 to 175DialExiting Cylinder (Meter Out)62005K53100000
    1/4
    60.33010.51500 to 175DialExiting Cylinder (Meter Out)62005K53200000
    1/4
    80.39012.51500 to 175DialExiting Cylinder (Meter Out)62005K53300000
    3/8
    60.56017.91500 to 175DialExiting Cylinder (Meter Out)62005K55100000
    3/8
    80.67021.41500 to 175DialExiting Cylinder (Meter Out)62005K55200000
    1/2
    101.33042.51500 to 175DialExiting Cylinder (Meter Out)62005K5600000
     
    Polybutylene Body with Pressure-Release Button
    1/8
    60.209.2814525 to 140DialExiting Cylinder (Meter Out)62005K17100000
    1/8
    80.209.2814525 to 140DialExiting Cylinder (Meter Out)62005K17200000
    1/4
    60.209.2814525 to 140DialExiting Cylinder (Meter Out)62005K17300000
    1/4
    80.209.2814525 to 140DialExiting Cylinder (Meter Out)62005K17400000
     
    BSPP Male Inlet × BSPP Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, BSPP Male Inlet × BSPP Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves, Meter Out.

    Meter Out

    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @
    100 psi
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.,
    scfm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Zinc Alloy Body
    1/8
    1/8
    0.34Not Rated12.614515 to 140DialExiting Cylinder (Meter Out)6857K25000000
    1/4
    1/4
    0.61Not Rated22.614515 to 140DialExiting Cylinder (Meter Out)6857K2600000
     
    Metric Male Inlet × Metric Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, Metric Male Inlet × Metric Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves, Meter Out.

    Meter Out

    Meter Out—Meter out valves control flow as it exits the cylinder.
    Inlet
    Outlet
    Flow Rate @
    100 psi
    Thread
    Size
    Thread
    Pitch, mm
    Thread
    Size
    Thread
    Pitch, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.,
    scfm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Zinc Alloy Body
    M5
    0.8M5
    0.80.1Not Rated3.514515 to 140DialExiting Cylinder (Meter Out)6857K24000000
     
    Metric Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, Metric Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves, Meter Out.

    Meter Out

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Inlet
    Flow Rate @ 100
    psi, scfm
    Thread
    Size
    Thread
    Pitch, mm
    For Outlet
    Tube OD, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    M5
    0.840.0802.61500 to 175DialExiting Cylinder (Meter Out)62005K511000000
    M5
    0.860.0802.61500 to 175DialExiting Cylinder (Meter Out)62005K51200000
     
    NPT Female Inlet × NPT Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, NPT Female Inlet × NPT Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Elbow Air Flow Control Valves, Meter In.

    Meter In

    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Zinc Alloy Body
    1/8
    1/8
    0.3909.214532 to 140DialEntering Cylinder (Meter In)8346K15000000
     
    UNF Female Inlet × UNF Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, UNF Female Inlet × UNF Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Elbow Air Flow Control Valves, Meter In.

    Meter In

    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 73
    psi, scfm
    Inlet Thread
    Size
    Outlet Thread
    Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Zinc Alloy Body
    10-32
    10-32
    0.0204.214532 to 140DialEntering Cylinder (Meter In)8346K14000000
     
    Push-to-Connect Female Inlet × NPT Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, Push-to-Connect Female Inlet × NPT Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Elbow Air Flow Control Valves, Meter In.

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 73
    psi, scfm
    Flow Rate @ 100
    psi, scfm
    For Inlet
    Tube OD
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Nylon Body
    5/32"1/8
    Not Rated07.514535 to 155DialEntering Cylinder (Meter In)45045K36000000
    1/4"1/8
    0.2607.414535 to 155DialEntering Cylinder (Meter In)45045K3800000
    Elbow Air Flow Control Valve, Nylon Body, 1/4" Push-Connect Inlet x 1/8 NPT Outlet
    EachIn stock
    1/4"1/4
    Not Rated013.914535 to 155DialEntering Cylinder (Meter In)45045K3900000
     
    Polybutylene Body
    1/8"1/8
    0.1207.214532 to 140DialEntering Cylinder (Meter In)62005K12100000
    5/32"1/8
    0.1504.81500 to 175DialEntering Cylinder (Meter In)62005K12200000
    5/32"1/4
    0.22071500 to 175DialEntering Cylinder (Meter In)62005K13100000
    1/4"1/8
    0.1906.11500 to 175DialEntering Cylinder (Meter In)62005K12400000
    1/4"1/4
    0.39012.51500 to 175DialEntering Cylinder (Meter In)62005K13300000
    1/4"3/8
    0.56017.91500 to 175DialEntering Cylinder (Meter In)62005K15100000
    5/16"1/8
    0.1906.11500 to 175DialEntering Cylinder (Meter In)62005K12500000
    5/16"1/4
    0.39012.51500 to 175DialEntering Cylinder (Meter In)62005K13400000
    5/16"3/8
    0.7308.614532 to 140DialEntering Cylinder (Meter In)62005K15200000
    3/8"1/4
    0.39012.51500 to 175DialEntering Cylinder (Meter In)62005K13500000
    3/8"3/8
    0.78024.91500 to 175DialEntering Cylinder (Meter In)62005K15300000
    3/8"1/2
    1.33042.51500 to 175DialEntering Cylinder (Meter In)62005K16100000
    1/2"1/2
    1.44042.314532 to 140DialEntering Cylinder (Meter In)62005K16200000
     
    Push-to-Connect Female Inlet × UNF Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, Push-to-Connect Female Inlet × UNF Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Elbow Air Flow Control Valves, Meter In.

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 87
    psi, scfm
    Flow Rate @ 100
    psi, scfm
    For Inlet
    Tube OD
    Outlet Thread
    Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Nylon Body
    1/8"10-32
    0.90314535 to 155DialEntering Cylinder (Meter In)45045K34000000
    5/32"10-32
    Not Rated0314535 to 155DialEntering Cylinder (Meter In)45045K3500000
    1/4"10-32
    Not Rated02.814535 to 155DialEntering Cylinder (Meter In)45045K3700000
     
    Polybutylene Body
    1/8"10-32
    0.0802.61500 to 175DialEntering Cylinder (Meter In)62005K11100000
    5/32"10-32
    0.0802.61500 to 175DialEntering Cylinder (Meter In)62005K11200000
     
    Push-to-Connect Female Inlet × BSPT Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, Push-to-Connect Female Inlet × BSPT Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Elbow Air Flow Control Valves, Meter In.

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 100
    psi, scfm
    For Inlet
    Tube OD, mm
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    41/8
    0.1504.81500 to 175DialEntering Cylinder (Meter In)62005K421000000
    41/4
    0.22071500 to 175DialEntering Cylinder (Meter In)62005K43100000
    61/8
    0.1906.11500 to 175DialEntering Cylinder (Meter In)62005K42200000
    61/4
    0.33010.51500 to 175DialEntering Cylinder (Meter In)62005K43200000
    63/8
    0.56017.91500 to 175DialEntering Cylinder (Meter In)62005K45100000
    81/8
    0.1906.11500 to 175DialEntering Cylinder (Meter In)62005K42300000
    81/4
    0.39012.51500 to 175DialEntering Cylinder (Meter In)62005K43300000
    83/8
    0.67021.41500 to 175DialEntering Cylinder (Meter In)62005K45200000
    101/2
    1.33042.51500 to 175DialEntering Cylinder (Meter In)62005K4600000
     
    Push-to-Connect Female Inlet × Metric Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, Push-to-Connect Female Inlet × Metric Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Elbow Air Flow Control Valves, Meter In.

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter In—Meter in valves control flow as it enters the cylinder.
    Outlet
    Flow Rate @ 100
    psi, scfm
    For Inlet
    Tube OD, mm
    Thread
    Size
    Thread
    Pitch, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    4M5
    0.80.0802.61500 to 175DialEntering Cylinder (Meter In)62005K411000000
    6M5
    0.80.0802.61500 to 175DialEntering Cylinder (Meter In)62005K41200000
     
    Quick-Disconnect Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves, Quick-Disconnect Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves, Meter Out.

    Meter Out

    Valves with quick disconnect ports can be installed in push-to-connect ports.
    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Pressure-Release Button—Valves with a pressure-release button allow you to exhaust any trapped air pressure from the system after shut down.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 87
    psi, scfm
    For Inlet
    Tube ID
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Nylon Body with Pressure-Release Button
    1/8"1/8"Not Rated02.114535 to 155DialExiting Cylinder (Meter Out)62005K654000000
    1/4"1/4"Not Rated04.814535 to 155DialExiting Cylinder (Meter Out)62005K65600000
    4 mm4 mmNot Rated0314535 to 155DialExiting Cylinder (Meter Out)62005K65500000
     

    Inline Air Flow Control Valves

    Designed to be mounted inline, these valves can be installed in an easy-to-reach location along your line. Flow control valves control the speed of air-powered equipment by adjusting the volume of airflow. They control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. Typically, valves are installed to control flow as it exits the cylinder (meter out), but they may also be installed to control flow as it enters the cylinder (meter in). For the best control, mount them as close to the cylinder as possible to minimize the length of tubing or piping between the cylinder and the valve.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    NPT Female Inlet × NPT Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves, NPT Female Inlet × NPT Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    Flow Rate @
    100 psi
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.,
    scfm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Nylon Body
    1/8
    1/8
    0.118Not Rated9.114535 to 155DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K613000000
    1/4
    1/4
    0.22Not Rated13.514535 to 155DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K62300000
    3/8
    3/8
    0.352Not Rated2014535 to 155DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K64300000
    1/2
    1/2
    0.523Not Rated30.214535 to 155DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K65300000
     
    NPT Male Inlet × Barbed Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves, NPT Male Inlet × Barbed Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    Valves with barbed ports are for use with soft plastic or rubber tubing; insert the barbed port into the tubing.
    Flow Rate @ 100
    psi, scfm
    Inlet Pipe
    Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Brass Body
    1/8
    0.117250-40 to 250DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)6692K19000000
     
    NPTF Female Inlet × NPTF Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves, NPTF Female Inlet × NPTF Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    NPTF (Dryseal) threads are compatible with NPT threads.
    Flow Rate @ 100
    psi, scfm
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Aluminum Body
    1/8
    1/8
    0.8147250-40 to 250DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)6692K16000000
    1/4
    1/4
    1.2166250-40 to 250DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)6692K1100000
    3/8
    3/8
    2.61149250-40 to 250DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)6692K1200000
    1/2
    1/2
    3.11173250-40 to 250DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)6692K13000000
     
    UNF Male Inlet × Barbed Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves, UNF Male Inlet × Barbed Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    Valves with barbed ports are for use with soft plastic or rubber tubing; insert the barbed port into the tubing.
    Flow Rate @ 100
    psi, scfm
    Inlet Thread
    Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Brass Body
    10-32
    0.117250-40 to 250DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)6692K15000000
     
    UNF Male Inlet × UNF Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves, UNF Male Inlet × UNF Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    Flow Rate @ 100
    psi, scfm
    Inlet Thread
    Size
    Outlet Thread
    Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Brass Body
    1/4"-28
    1/4"-28
    0.118250-40 to 250DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)6692K17000000
     
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves, Push-to-Connect Female Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Flow Rate @ 73
    psi, scfm
    Flow Rate @ 100
    psi, scfm
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Polybutylene Body
    1/8"1/8"0.10414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K35000000
    5/32"5/32"0.1305.214525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K31100000
    3/16"3/16"0.1906.114532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K31200000
    1/4"1/4"0.1909.214525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K31300000
    1/4"1/4"0.42015.614525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K33100000
    1/4"1/4"0.47018.414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K32200000
    5/16"5/16"0.47018.414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K32300000
    5/16"5/16"0.67026.414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K33200000
    3/8"3/8"0.9303714525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K33300000
    3/8"3/8"1.0603714525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K34100000
    1/2"1/2"1.41055.614525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K34200000
    4 mm4 mm0.1305.214525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K61100000
    6 mm6 mm0.2309.214525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K61200000
    6 mm6 mm0.29011.614525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K62100000
    6 mm6 mm0.42016.814525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K63100000
    8 mm8 mm0.47018.414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K62200000
    8 mm8 mm0.67026.414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K63200000
    10 mm10 mm0.93036.814525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K63300000
    12 mm12 mm0.9303714525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)62005K3600000
     
    Barbed Male Inlet × Barbed Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves, Barbed Male Inlet × Barbed Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    Valves with barbed ports are for use with soft plastic or rubber tubing; insert the barbed port into the tubing.
    Flow Rate @ 100
    psi, scfm
    For Inlet
    Tube ID
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Brass Body
    3/16"0.117250-40 to 250DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)6692K18000000
     

    Inline Air Flow Control Valves with Flow Indicator

    A flow indicator on these valves provides a relative measure of the air flowing through the valve, from off to full volume, similar to the volume dial on a speaker. The indicator’s numeric increments make it easy to set the valve to the same flow rate with each use. They adjust the volume of airflow to control the speed of air-powered equipment. Valves control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. Typically, valves are installed to control flow as it exits the cylinder (meter out), but they may also be installed to control flow as it enters the cylinder (meter in). Designed to be mounted inline, they can be installed in an easy-to-reach location along your line. For the best control, mount them as close to the cylinder as possible to minimize the length of tubing or piping between the cylinder and the valve.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
    NPT Female Inlet × NPT Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves with Flow Indicator, NPT Female Inlet × NPT Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves with Flow Indicator, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves with Flow Indicator, Meter In.

    Meter Out

    Meter In

    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Aluminum Body with Flow Indicator
    1/4
    1/4
    0.82034.4514525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N118000000
    3/8
    3/8
    0.82034.4514525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N11900000
     
    NPTF Female Inlet × NPTF Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves with Flow Indicator, NPTF Female Inlet × NPTF Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves with Flow Indicator, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves with Flow Indicator, Meter In.

    Meter Out

    Meter In

    NPTF (Dryseal) threads are compatible with NPT threads.
    Flow Rate @ 100
    psi, scfm
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Brass Body with Flow Indicator
    1/8
    1/8
    1.415322500 to 180DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N12000000
    1/4
    1/4
    1.2228752500 to 180DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N13700000
    3/8
    3/8
    2.58591392500 to 180DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N138000000
    1/2
    1/2
    5.511261832500 to 180DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N139000000
    3/4
    3/4
    6.121403272500 to 180DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N141000000
     
    BSPP Female Inlet × BSPP Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves with Flow Indicator, BSPP Female Inlet × BSPP Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves with Flow Indicator, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves with Flow Indicator, Meter In.

    Meter Out

    Meter In

    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Aluminum Body with Flow Indicator
    1/4
    1/4
    0.82032.414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N121000000
    3/8
    3/8
    0.82032.414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N12200000
     
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Air Flow Control Valves with Flow Indicator, Push-to-Connect Female Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Air Flow Control Valves with Flow Indicator, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Air Flow Control Valves with Flow Indicator, Meter In.

    Meter Out

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Flow Rate @ 73
    psi, scfm
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Polybutylene Body with Flow Indicator
    1/8"1/8"0.0602.5214525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N111000000
    5/32"5/32"0.0803.3614525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N11200000
    1/4"1/4"0.0805.1814525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N12500000
    1/4"1/4"0.2208.6414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N12800000
    1/4"1/4"0.29012.1814525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N11300000
    5/16"5/16"0.29013.8214525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N13200000
    3/8"3/8"0.53020.7414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N13500000
    3/8"3/8"0.6025.2114525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N11400000
    1/2"1/2"0.77030.2414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N13600000
    4 mm4 mm0.0803.3614525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N11500000
    6 mm6 mm0.0805.1814525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N12400000
    6 mm6 mm0.2208.6414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N12600000
    6 mm6 mm0.29012.1814525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N11600000
    8 mm8 mm0.26010.3714525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N12700000
    8 mm8 mm0.42017.6514525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N11700000
    10 mm10 mm0.2901914525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N12900000
    10 mm10 mm0.53020.7414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N13300000
    12 mm12 mm0.77030.2414525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)3019N13400000
     

    Elbow Corrosion-Resistant Air Flow Control Valves

    Mount these valves directly to cylinder ports, eliminating additional tubing or piping between the cylinder and valve for better control than inline valves. Made of stainless steel and plastic parts, they’re more corrosion resistant than valves made of brass, aluminum, or zinc alloy. Use them to control the speed of air-powered equipment by adjusting the volume of airflow. They control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    NPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Corrosion-Resistant Air Flow Control Valves, NPT Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Corrosion-Resistant Air Flow Control Valves, Meter Out.

    Meter Out

    Pressure-Release Button—Valves with a pressure-release button allow you to exhaust any trapped air pressure from the system after shut down.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    1/8
    1/8"0.1507.214532 to 140DialExiting Cylinder (Meter Out)9066K11000000
    1/8
    1/4"0.1909.214532 to 140DialExiting Cylinder (Meter Out)9066K1200000
    1/4
    1/4"0.39018.414532 to 140DialExiting Cylinder (Meter Out)9066K1300000
    1/4
    3/8"0.39018.414532 to 140DialExiting Cylinder (Meter Out)9066K1400000
    1/2
    3/8"0.67063.214532 to 140DialExiting Cylinder (Meter Out)9066K1600000
    1/2
    1/2"1.44068.414532 to 140DialExiting Cylinder (Meter Out)9066K1700000
     
    Polybutylene Body with Pressure-Release Button
    1/8
    5/32"0.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K4300000
    1/8
    5/16"0.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K4400000
    1/4
    5/32"0.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K4500000
    1/4
    5/16"0.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K4600000
    3/8
    1/4"0.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K4700000
    3/8
    5/16"0.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K4800000
    3/8
    3/8"0.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K4900000
     
    UNF Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Corrosion-Resistant Air Flow Control Valves, UNF Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Corrosion-Resistant Air Flow Control Valves, Meter Out.

    Meter Out

    Pressure-Release Button—Valves with a pressure-release button allow you to exhaust any trapped air pressure from the system after shut down.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 73
    psi, scfm
    Inlet Thread
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    10-32
    1/8"0.10414532 to 140DialExiting Cylinder (Meter Out)9066K34000000
     
    Polybutylene Body with Pressure-Release Button
    10-32
    5/32"0.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K4100000
    10-32
    1/4"0.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K4200000
     
    BSPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Corrosion-Resistant Air Flow Control Valves, BSPT Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Corrosion-Resistant Air Flow Control Valves, Meter Out.

    Meter Out

    Pressure-Release Button—Valves with a pressure-release button allow you to exhaust any trapped air pressure from the system after shut down.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body with Pressure-Release Button
    1/8
    60.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K52000000
    1/8
    80.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K5300000
    1/4
    80.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K5400000
     
    Metric Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Corrosion-Resistant Air Flow Control Valves, Metric Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Corrosion-Resistant Air Flow Control Valves, Meter Out.

    Meter Out

    Pressure-Release Button—Valves with a pressure-release button allow you to exhaust any trapped air pressure from the system after shut down.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 73
    psi, scfm
    Inlet Thread
    Size
    For Outlet
    Tube OD, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body with Pressure-Release Button
    M5
    60.0702.614525 to 140DialExiting Cylinder (Meter Out)9066K51000000
     
    Push-to-Connect Female Inlet × NPT Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Corrosion-Resistant Air Flow Control Valves, Push-to-Connect Female Inlet × NPT Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Elbow Corrosion-Resistant Air Flow Control Valves, Meter In.

    Meter In

    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 73
    psi, scfm
    For Inlet
    Tube OD
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    1/4"1/8
    0.1909.214532 to 140DialEntering Cylinder (Meter In)9066K18000000
    1/4"1/4
    0.39018.414532 to 140DialEntering Cylinder (Meter In)9066K1900000
    3/8"1/4
    0.39018.414532 to 140DialEntering Cylinder (Meter In)9066K2100000
     
    Push-to-Connect Female Inlet × UNF Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Corrosion-Resistant Air Flow Control Valves, Push-to-Connect Female Inlet × UNF Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Elbow Corrosion-Resistant Air Flow Control Valves, Meter In.

    Meter In

    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 73
    psi, scfm
    For Inlet
    Tube OD
    Outlet Thread
    Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    1/8"10-32
    0.10414532 to 140DialEntering Cylinder (Meter In)9066K35000000
     

    Precision-Adjust Air Flow Control Valves

    A fine-adjustment dial allows tighter control of airflow and cylinder speed than with other flow control valves. These valves control the speed of air-powered equipment by adjusting the volume of airflow. They control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. The elbow shape allows you to mount them directly to cylinder ports, eliminating additional tubing or piping between the cylinder and valve for better control and consistency than inline valves.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    NPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Precision-Adjust Air Flow Control Valves, NPT Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Precision-Adjust Air Flow Control Valves, Meter Out.

    Meter Out

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 87
    psi, scfm
    Flow Rate @ 100
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Nylon Body
    1/8
    1/8"0.200.114535 to 155DialExiting Cylinder (Meter Out)4076K37000000
    1/8
    5/32"0.1801314535 to 155DialExiting Cylinder (Meter Out)4076K2700000
    1/8
    5/32"0.207.514535 to 155DialExiting Cylinder (Meter Out)4076K3300000
    1/8
    1/4"0.1801314535 to 155DialExiting Cylinder (Meter Out)4076K2200000
    1/4
    5/32"0.1801314535 to 155DialExiting Cylinder (Meter Out)4076K2800000
    1/4
    1/4"0.1801314535 to 155DialExiting Cylinder (Meter Out)4076K2300000
    1/4
    3/8"0.27018.514535 to 155DialExiting Cylinder (Meter Out)4076K2500000
    3/8
    3/8"Not Rated06514535 to 155DialExiting Cylinder (Meter Out)4076K2600000
     
    UNF Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Precision-Adjust Air Flow Control Valves, UNF Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Precision-Adjust Air Flow Control Valves, Meter Out.

    Meter Out

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 100
    psi, scfm
    Inlet Thread
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Nylon Body
    10-32
    1/8"0.0902.514535 to 155DialExiting Cylinder (Meter Out)4076K29000000
    10-32
    5/32"0.0902.714535 to 155DialExiting Cylinder (Meter Out)4076K3200000
    10-32
    1/4"0.250314535 to 155DialExiting Cylinder (Meter Out)4076K2100000
     
    BSPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Precision-Adjust Air Flow Control Valves, BSPT Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Precision-Adjust Air Flow Control Valves, Meter Out.

    Meter Out

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    1/8
    40.1507.214532 to 140DialExiting Cylinder (Meter Out)4057T11000000
    1/8
    60.1909.214532 to 140DialExiting Cylinder (Meter Out)4057T1200000
    1/8
    80.1909.214532 to 140DialExiting Cylinder (Meter Out)4057T1300000
    1/4
    40.22011.214532 to 140DialExiting Cylinder (Meter Out)4057T1400000
    1/4
    60.33015.614532 to 140DialExiting Cylinder (Meter Out)4057T1500000
    1/4
    80.39018.414532 to 140DialExiting Cylinder (Meter Out)4057T1600000
    1/4
    100.39018.414532 to 140DialExiting Cylinder (Meter Out)4057T1700000
     
    Push-to-Connect Female Inlet × NPT Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Precision-Adjust Air Flow Control Valves, Push-to-Connect Female Inlet × NPT Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Precision-Adjust Air Flow Control Valves, Meter In.

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 73
    psi, scfm
    Flow Rate @ 100
    psi, scfm
    For Inlet
    Tube OD
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Nylon Body
    1/4"1/8
    0.2607.414535 to 155DialEntering Cylinder (Meter In)4076K38000000
     
    Polybutylene Body
    1/4"1/4
    0.6018.414532 to 140DialEntering Cylinder (Meter In)4076K3400000
    3/8"1/4
    0.6018.414532 to 140DialEntering Cylinder (Meter In)4076K3500000
     
    Push-to-Connect Female Inlet × UNF Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Precision-Adjust Air Flow Control Valves, Push-to-Connect Female Inlet × UNF Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Precision-Adjust Air Flow Control Valves, Meter In.

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @
    100 psi
    For Inlet
    Tube OD
    Outlet Thread
    Size
    Flow Coefficient
    (Cv)
    Min.
    Max.,
    scfm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Nylon Body
    1/8"10-32
    0.9Not Rated0.114535 to 155DialEntering Cylinder (Meter In)4076K39000000
     
    Push-to-Connect Female Inlet × BSPT Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Precision-Adjust Air Flow Control Valves, Push-to-Connect Female Inlet × BSPT Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Precision-Adjust Air Flow Control Valves, Meter In.

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 73
    psi, scfm
    For Inlet
    Tube OD, mm
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    41/8
    0.1507.214532 to 140DialEntering Cylinder (Meter In)4057T18000000
    41/4
    0.22011.214532 to 140DialEntering Cylinder (Meter In)4057T2200000
    61/8
    0.1909.214532 to 140DialEntering Cylinder (Meter In)4057T1900000
    61/4
    0.33015.614532 to 140DialEntering Cylinder (Meter In)4057T2300000
    81/8
    0.1909.214532 to 140DialEntering Cylinder (Meter In)4057T2100000
    81/4
    0.39018.414532 to 140DialEntering Cylinder (Meter In)4057T2400000
    101/4
    0.39018.414532 to 140DialEntering Cylinder (Meter In)4057T2500000
     

    Elbow Air Flow Control Valves with Flow Indicator

    A flow indicator on these valves provides a relative measure of the air flowing through the valve, from off to full volume, similar to the volume dial on a speaker. The indicator’s numeric increments make it easy to set the valve to the same flow rate with each use. These valves adjust the volume of air exiting an air cylinder (meter out) to control the speed of air-powered equipment. They control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. The elbow shape allows you to mount them directly to cylinder ports, eliminating additional tubing between the cylinder and valve for better control and consistency than inline valves. Insert plastic or soft metal tubing into the push-to-connect outlet ports.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    NPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves with Flow Indicator, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves with Flow Indicator.

    Meter Out

    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body with Flow Indicator
    1/8
    1/8"0.1105.214525 to 140DialExiting Cylinder (Meter Out)2768N14000000
    1/8
    5/32"0.1705.214525 to 140DialExiting Cylinder (Meter Out)2768N1500000
    1/8
    1/4"0.1705.214525 to 140DialExiting Cylinder (Meter Out)2768N1600000
    1/8
    5/16"0.1705.214525 to 140DialExiting Cylinder (Meter Out)2768N1700000
    1/4
    1/4"0.4205.214525 to 140DialExiting Cylinder (Meter Out)2768N1800000
    1/4
    3/8"0.4205.214525 to 140DialExiting Cylinder (Meter Out)2768N1900000
    3/8
    1/4"0.4405.214525 to 140DialExiting Cylinder (Meter Out)2768N2100000
    3/8
    3/8"0.6905.214525 to 140DialExiting Cylinder (Meter Out)2768N2200000
     
    UNF Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves with Flow Indicator, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves with Flow Indicator.

    Meter Out

    Flow Rate @ 73
    psi, scfm
    Inlet Thread
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body with Flow Indicator
    10-32
    1/8"0.0802.614525 to 140DialExiting Cylinder (Meter Out)2768N11000000
    10-32
    5/32"0.0802.614525 to 140DialExiting Cylinder (Meter Out)2768N1200000
    10-32
    1/4"0.0802.614525 to 140DialExiting Cylinder (Meter Out)2768N1300000
     
    BSPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves with Flow Indicator, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves with Flow Indicator.

    Meter Out

    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body with Flow Indicator
    1/8
    60.1705.214525 to 140DialExiting Cylinder (Meter Out)2768N25000000
    1/4
    80.1705.214525 to 140DialExiting Cylinder (Meter Out)2768N2600000
     
    Metric Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Elbow Air Flow Control Valves with Flow Indicator, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Elbow Air Flow Control Valves with Flow Indicator.

    Meter Out

    Inlet
    Flow Rate @ 73
    psi, scfm
    Thread
    Size
    Thread
    Pitch, mm
    For Outlet
    Tube OD, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body with Flow Indicator
    M5
    0.840.0805.214525 to 140DialExiting Cylinder (Meter Out)2768N23000000
    M5
    0.860.0805.214525 to 140DialExiting Cylinder (Meter Out)2768N2400000
     

    Dual-Control Two-Direction Air Flow Control Valves

    Two knobs independently control airflow in each direction. These valves control flow in two directions as air moves from the inlet to the outlet and from the outlet to the inlet. They’re often used to control both the extension speed as flow enters a cylinder (meter in), and the retraction speed as flow exits a cylinder (meter out). For the best control, mount them as close to the cylinder as possible to minimize the length of piping between the cylinder and the valve.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
    BSPP Female Inlet × BSPP Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Dual-Control Two-Direction Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Dual-Control Two-Direction Air Flow Control Valves, Meter In.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Dual-Control Two-Direction Air Flow Control Valves.

    Meter Out

    Meter In

    Flow Rate @
    100 psi
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.,
    scfm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Aluminum Body
    1/8
    1/8
    0.18Not Rated6.81450 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)8897K12000000
     

    Inline Corrosion-Resistant Air Flow Control Valves

    Made of stainless steel and plastic parts, these valves are more corrosion resistant than valves made of brass, aluminum, or zinc alloy. They control the speed of air-powered equipment by adjusting the volume of airflow. Use them to control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. Typically, valves are installed to control flow as it exits the cylinder (meter out), but they may also be installed to control flow as it enters the cylinder (meter in). They’re designed to be mounted inline, allowing you to install them in an easy-to-reach location along your line. For the best control, mount them as close to the cylinder as possible to minimize the length of tubing between the cylinder and the valve. Insert plastic or soft metal tubing into the push-to-connect ports.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Inline Corrosion-Resistant Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Inline Corrosion-Resistant Air Flow Control Valves, Meter In.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Inline Corrosion-Resistant Air Flow Control Valves.

    Meter Out

    Meter In

    Flow Rate @ 73
    psi, scfm
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Polybutylene Body
    1/8"1/8"0.10414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K36000000
    5/32"5/32"0.1Not Rated414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K5600000
    5/32"5/32"0.13Not Rated5.214532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K6200000
    3/16"3/16"0.1Not Rated414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K5800000
    3/16"3/16"0.29Not Rated11.614532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K6500000
    1/4"1/4"0.1Not Rated414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K6100000
    1/4"1/4"0.1909.214532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K3100000
    1/4"1/4"0.42Not Rated16.814532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K7200000
    1/4"1/4"0.46Not Rated18.414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K6700000
    5/16"5/16"0.46Not Rated18.414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K6900000
    5/16"5/16"0.66Not Rated26.414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K7400000
    3/8"3/8"0.78036.814532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K3200000
    3/8"3/8"1.05Not Rated4214532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K7800000
    1/2"1/2"1.17055.614532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K3300000
    3.2 mm3.2 mm0.1Not Rated414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K5500000
    4 mm4 mm0.1Not Rated414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K5700000
    4 mm4 mm0.13Not Rated5.214532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K6300000
    6 mm6 mm0.1Not Rated414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K5900000
    6 mm6 mm0.23Not Rated9.214532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K6400000
    6 mm6 mm0.29Not Rated11.614532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K6600000
    6 mm6 mm0.42Not Rated16.814532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K7100000
    8 mm8 mm0.46Not Rated18.414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K6800000
    8 mm8 mm0.66Not Rated26.414532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K7300000
    10 mm10 mm0.92Not Rated36.814532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K7500000
    10 mm10 mm1.05Not Rated4214532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K7700000
    12 mm12 mm0.92Not Rated36.814532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K7600000
    12 mm12 mm1.39Not Rated55.614532 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)9066K7900000
     

    High-Pressure Air Flow Control Valves

    These valves handle pressure up to 265 psi. They adjust the volume of air exiting an air cylinder (meter out) to control the speed of air-powered equipment. Use them to control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. The inlet has a universal thread for connecting to NPT, NPTF (Dryseal), BSPP, and BSPT threads. Insert plastic or soft metal tubing into the push-to-connect outlet ports. The elbow shape allows you to mount them directly to cylinder ports, eliminating additional piping between the cylinder and valve for better control and consistency than inline valves.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    BSPP, BSPT, NPT, NPTF Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Dial Flow Adjustment. Front orientation. Contains Annotated. Flow-Adjustment Dial. High-Pressure Air Flow Control Valves.
    Image of Product. Slotted Screw Flow Adjustment. Front orientation. Contains Annotated. Flow-Adjustment Slotted Screw. High-Pressure Air Flow Control Valves.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. High-Pressure Air Flow Control Valves, Meter Out.

    Dial Flow

    Adjustment

    Slotted Screw

    Flow Adjustment

    Meter Out

    NPTF (Dryseal) threads are compatible with NPT threads.
    Flow Rate @ 100
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Brass Body
    1/8
    1/8"0.0905265-20 to 175DialExiting Cylinder (Meter Out)2273K31000000
    1/8
    5/32"0.1407.8265-20 to 175Slotted ScrewExiting Cylinder (Meter Out)1045K1200000
    1/8
    1/4"0.22012.3265-20 to 175DialExiting Cylinder (Meter Out)2273K3300000
    1/8
    1/4"0.22012.3265-20 to 175Slotted ScrewExiting Cylinder (Meter Out)1045K1300000
    1/4
    1/4"0.27015.1265-20 to 175DialExiting Cylinder (Meter Out)2273K3400000
    1/4
    1/4"0.27015.1265-20 to 175Slotted ScrewExiting Cylinder (Meter Out)1045K1400000
    1/4
    3/8"0.41023265-20 to 175DialExiting Cylinder (Meter Out)2273K3700000
    1/4
    3/8"0.41023265-20 to 175Slotted ScrewExiting Cylinder (Meter Out)1045K1700000
    3/8
    3/8"0.42023.5265-20 to 175DialExiting Cylinder (Meter Out)2273K3800000
    3/8
    3/8"0.42023.5265-20 to 175Slotted ScrewExiting Cylinder (Meter Out)1045K1800000
     

    Single-Control Two-Direction Air Flow Control Valves

    A single dial adjusts the speed of airflow equally in both directions. These valves control flow in two directions as air moves from the inlet to the outlet and from the outlet to the inlet. They’re often used to control the extension speed as flow enters a cylinder (meter in), and the retraction speed as flow exits a cylinder (meter out) at the same time. For the best control, mount them as close to the cylinder as possible to minimize the length of tubing between the cylinder and the valve.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
    BSPP Female Inlet × BSPP Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Single-Control Two-Direction Air Flow Control Valves, BSPP Female Inlet × BSPP Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Single-Control Two-Direction Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Single-Control Two-Direction Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    Flow Rate @
    100 psi
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.,
    scfm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Aluminum Body
    1/8
    1/8
    0.19Not Rated7.17145-4 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)8642K120000000
    1/4
    1/4
    0.35Not Rated12.95145-4 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)8642K13000000
     
    Metric Female Inlet × Metric Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Single-Control Two-Direction Air Flow Control Valves, Metric Female Inlet × Metric Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Single-Control Two-Direction Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Single-Control Two-Direction Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    Inlet
    Outlet
    Flow Rate @
    100 psi
    Thread
    Size
    Thread
    Pitch, mm
    Thread
    Size
    Thread
    Pitch, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.,
    scfm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Aluminum Body
    M5
    0.8M5
    0.80.09Not Rated3.33145-4 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)8642K110000000
     
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Single-Control Two-Direction Air Flow Control Valves, Push-to-Connect Female Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Single-Control Two-Direction Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Single-Control Two-Direction Air Flow Control Valves, Meter In.

    Meter Out

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Flow Rate @
    100 psi
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.,
    scfm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Nylon Body
    1/4"1/4"0.037Not Rated6.5314535 to 155DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)8642K14000000
     

    Corrosion-Resistant Single-Control Two-Direction Air Flow Control Valves

    Made of polybutylene, these plastic valves are more corrosion resistant than valves made of aluminum or nylon. A single dial regulates the speed of airflow in two directions as it enters (meter in) and exits (meter out) equipment, and are often used to control the extension and retraction speed of an air cylinder at the same time. Insert plastic or soft metal tubing into the push-to-connect outlet ports; the outlet ports swivel 360° so you can make a connection from any direction. The elbow shape allows you to mount these valves directly to cylinder ports, eliminating additional tubing between the cylinder and valve for better control and consistency than inline valves.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
    NPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Corrosion-Resistant Single-Control Two-Direction Air Flow Control Valves , Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Corrosion-Resistant Single-Control Two-Direction Air Flow Control Valves , Meter In.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Corrosion-Resistant Single-Control Two-Direction Air Flow Control Valves .

    Meter Out

    Meter In

    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Polybutylene Body with Swiveling Outlet Connection
    1/8
    1/4"0.180714525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)2814N22000000
    1/4
    1/4"0.180714525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)2814N2300000
    1/4
    3/8"0.180714525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)2814N2400000
     
    UNF Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Corrosion-Resistant Single-Control Two-Direction Air Flow Control Valves , Meter Out.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Corrosion-Resistant Single-Control Two-Direction Air Flow Control Valves , Meter In.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Corrosion-Resistant Single-Control Two-Direction Air Flow Control Valves .

    Meter Out

    Meter In

    Flow Rate @ 73
    psi, scfm
    Inlet Thread
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Each
    Polybutylene Body with Swiveling Outlet Connection
    10-32
    1/8"0.070314525 to 140DialExiting Cylinder (Meter Out), Entering Cylinder (Meter In)2814N21000000
     

    Tamper-Resistant Air Flow Control Valves

    Prevent accidental airflow changes with these valves, which require an adjustment tool (sold separately) to alter their flow rate. Use them to control the speed of air-powered equipment by adjusting the volume of airflow. They control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. The elbow shape allows you to mount them directly to cylinder ports, eliminating additional tubing or piping between the cylinder and valve for better control and consistency than inline valves.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    NPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Tamper-Resistant Air Flow Control Valves, NPT Male Inlet × Push-to-Connect Female Outlet.
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Tamper-Resistant Air Flow Control Valves, Meter Out.

    Meter Out

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter Out—Meter out valves control flow as it exits the cylinder.
    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    1/8
    1/8"0.1507.214532 to 140Tamper-Resistant ScrewExiting Cylinder (Meter Out)8940K11000000
    1/8
    1/4"0.1909.214532 to 140Tamper-Resistant ScrewExiting Cylinder (Meter Out)8940K1300000
    1/4
    1/4"0.39018.414532 to 140Tamper-Resistant ScrewExiting Cylinder (Meter Out)8940K1500000
    1/4
    3/8"0.39018.414532 to 140Tamper-Resistant ScrewExiting Cylinder (Meter Out)8940K1600000
    3/8
    1/4"0.56027.214532 to 140Tamper-Resistant ScrewExiting Cylinder (Meter Out)8940K1700000
    3/8
    3/8"0.78036.814532 to 140Tamper-Resistant ScrewExiting Cylinder (Meter Out)8940K1800000
    1/2
    3/8"1.33063.214532 to 140Tamper-Resistant ScrewExiting Cylinder (Meter Out)8940K1900000
    1/2
    1/2"1.44068.414532 to 140Tamper-Resistant ScrewExiting Cylinder (Meter Out)8940K2100000
     
    Flow-Regulating Valve Adjustment Tools
    Push-to-Connect Female Inlet × NPT Male Outlet
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Tamper-Resistant Air Flow Control Valves, Push-to-Connect Female Inlet × NPT Male Outlet.
    Image of Product. Front orientation. Contains Annotated. Entering Cylinder. Tamper-Resistant Air Flow Control Valves, Meter In.

    Meter In

    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    Meter In—Meter in valves control flow as it enters the cylinder.
    Flow Rate @ 73
    psi, scfm
    For Inlet
    Tube OD
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Polybutylene Body
    1/8"1/8
    0.1507.214532 to 140Tamper-Resistant ScrewEntering Cylinder (Meter In)8940K22000000
    1/4"1/8
    0.1909.214532 to 140Tamper-Resistant ScrewEntering Cylinder (Meter In)8940K2400000
    1/4"1/4
    0.39018.414532 to 140Tamper-Resistant ScrewEntering Cylinder (Meter In)8940K2600000
    1/4"3/8
    0.56027.214532 to 140Tamper-Resistant ScrewEntering Cylinder (Meter In)8940K2800000
    3/8"1/4
    0.39018.414532 to 140Tamper-Resistant ScrewEntering Cylinder (Meter In)8940K2700000
    3/8"3/8
    0.78036.814532 to 140Tamper-Resistant ScrewEntering Cylinder (Meter In)8940K2900000
    3/8"1/2
    1.33063.214532 to 140Tamper-Resistant ScrewEntering Cylinder (Meter In)8940K3100000
    1/2"1/2
    1.44068.414532 to 140Tamper-Resistant ScrewEntering Cylinder (Meter In)8940K3200000
     
    Flow-Regulating Valve Adjustment Tools

    Flexible-Mount Air Flow Control Valves

    A swiveling outlet port allows you to make a connection from any direction. These valves adjust the volume of air exiting an air cylinder (meter out) to control the speed of air-powered equipment. They control flow in one direction as air moves from the inlet to the outlet. Air flows freely in the opposite direction. The valve body has an elbow shape, which allows you to mount them directly to cylinder ports, eliminating additional tubing between the cylinder and valve for better control and consistency than inline valves. Insert plastic or soft metal tubing into the push-to-connect outlet ports.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    NPT Male Inlet × Push-to-Connect Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Flexible-Mount Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Flexible-Mount Air Flow Control Valves.

    Meter Out

    Flow Rate @
    100 psi
    Inlet Pipe
    Size
    For Outlet
    Tube OD
    Flow Coefficient
    (Cv)
    Min.
    Max.,
    scfm
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Nylon Body with Swiveling Outlet Connection
    1/8
    1/4"0.44Not Rated21.714535 to 155DialExiting Cylinder (Meter Out)2959T11000000
    1/4
    1/4"0.86Not Rated25.714535 to 155DialExiting Cylinder (Meter Out)2959T1200000
    1/4
    3/8"3.56Not Rated83.214535 to 155DialExiting Cylinder (Meter Out)2959T1300000
    3/8
    3/8"4.49Not Rated104.914535 to 155DialExiting Cylinder (Meter Out)2959T1400000
     

    Air-Operated Air Flow Control Valves with Safety Shut-Off

    Image of System. Front orientation. CrossSection view. Contains Annotated. Air Flow Control Valves. Air-Operated Air Flow Control Valves with Safety Shut-Off.
    Protect air-powered equipment in emergency shut-off situations—when system pressure drops, the air signal stops and these valves automatically close to stop cylinder motion, even at a mid-stroke. They control the speed of air-powered equipment by adjusting the volume of airflow. A pressure-release button allows you to exhaust any trapped air pressure from the system after shut down. Install them in pairs on cylinder exhaust ports, and use tee connectors (not included) to direct exhaust air from the cylinder to the air of the opposite valve, and to connect valves to a directional control valve. The elbow shape allows you to mount them directly to cylinder ports, eliminating additional tubing or piping between the cylinder and valve for better control and consistency than inline valves.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
    Push-to-Connect Female Inlet × NPT Male Outlet × Female Air Pilot
    Image of Product. Bottom orientation. Contains Annotated. Air Flow Control Valves. Air-Operated Air Flow Control Valves with Safety Shut-Off, Push-to-Connect Female Inlet × NPT Male Outlet × Female Air Pilot.
    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    One Direction—One direction valves control flow as air exits the cylinder (meter out) and moves from the inlet to the outlet.
    Air Pilot
    Flow Rate @ 73
    psi, scfm
    For Inlet
    Tube OD
    Outlet
    Pipe Size
    Pipe
    Size
    Thread
    Size
    Thread
    Type
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Features
    Each
    Polybutylene Body—One Direction
    1/4"1/8
    10-32
    UNF
    0.1807.214525 to 140DialExiting Cylinder (Meter Out)Pressure-Release Button2747N111000000
    1/4"1/4
    1/8
    NPT
    0.1807.214525 to 140DialExiting Cylinder (Meter Out)Pressure-Release Button2747N11200000
    3/8"3/8
    1/8
    NPT
    0.1807.214525 to 140DialExiting Cylinder (Meter Out)Pressure-Release Button2747N11300000
     
    Push-to-Connect Female Inlet × BSPP Male Outlet × Push-to-Connect Female Air Pilot
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Air-Operated Air Flow Control Valves with Safety Shut-Off, Push-to-Connect Female Inlet × BSPP Male Outlet × Push-to-Connect Female Air Pilot.
    Valves with push-to-connect ports are for use with plastic or soft metal tubing. Insert tubing into the port.
    One Direction—One direction valves control flow as air exits the cylinder (meter out) and moves from the inlet to the outlet.
    Two Direction—Two direction valves control airflow as it enters (meter in) and exits (meter out) equipment, and are often used to control the extension and retraction speed of an air cylinder at the same time.
    Flow Rate @ 87
    psi, scfm
    Flow Rate @ 100
    psi, scfm
    For Inlet
    Tube OD, mm
    Outlet
    Pipe Size
    For Air Pilot
    Tube OD, mm
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location (ISO Designation)
    Features
    Each
    Nylon Body—One Direction
    61/4
    4Not Rated016.7714525 to 140DialExiting Cylinder (Meter Out)Pressure-Release Button2747N1140000000
    81/8
    4Not Rated08.4814525 to 140DialExiting Cylinder (Meter Out)Pressure-Release Button2747N115000000
    83/8
    4Not Rated030.914525 to 140DialExiting Cylinder (Meter Out)Pressure-Release Button2747N116000000
    103/8
    4Not Rated033.214525 to 140DialExiting Cylinder (Meter Out)Pressure-Release Button2747N117000000
     
    Polybutylene Body—Two Direction
    61/8
    60.23408.114515 to 140Slotted ScrewExiting Cylinder (Meter Out), Entering Cylinder (Meter In)Pressure-Release Button2747N118000000
    81/4
    80.549018.914515 to 140Slotted ScrewExiting Cylinder (Meter Out), Entering Cylinder (Meter In)Pressure-Release Button2747N119000000
     

    Slow-Start Air Flow Control Valves

    Prevent damage to your equipment by limiting startup airflow and then gradually raising the airflow rate to operating levels. These valves adjust the volume of air exiting an air cylinder (meter out) to control the speed of air-powered equipment. They control flow in one direction; air flows freely in the opposite direction. For the best control, mount them as close to the cylinder as possible to minimize the length of tubing between the cylinder and the valve.
    Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
    NPT Female Inlet × NPT Female Outlet
    Image of Product. Front orientation. Contains Annotated. Exiting Cylinder. Slow-Start Air Flow Control Valves, Meter Out.
    Image of Product. Front orientation. Contains Annotated. Air Flow Control Valves. Slow-Start Air Flow Control Valves.

    Meter Out

    Flow Rate @ 73
    psi, scfm
    Inlet Pipe
    Size
    Outlet
    Pipe Size
    Flow Coefficient
    (Cv)
    Min.
    Max.
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Flow Adjustment
    Mechanism
    Flow Control Location
    (ISO Designation)
    Each
    Zinc Alloy Body
    1/8
    1/8
    0.540610132 to 140DialExiting Cylinder (Meter Out)61635K11000000
    1/4
    1/4
    1.2203610132 to 140DialExiting Cylinder (Meter Out)61635K1200000
    3/8
    3/8
    1.2203610132 to 140DialExiting Cylinder (Meter Out)61635K1300000
    1/2
    1/2
    3.06014010132 to 140DialExiting Cylinder (Meter Out)61635K14000000
     