McMaster-Carr logo
    Filter by
    Pipe Material
    Shape
    System of Measurement
    Fitting Type
    Industrial Info Compare
    Pipe Schedule
    Industrial Info Snippet
    Fitting Connection
    Color
    For Flange Schedule
    Industrial Info Snippet
    Flange Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Minimum Temperature
    Maximum Temperature
    Connects To
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Maximum Air Back Pressure
    Maximum Pressure @ Temperature
    Industrial Info Snippet
    Pressure Rating
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    27 Products
    About Pipe and Fittings
    industrial info icon

    Measure your pipe and fittings to identify their pipe size, thread size, schedule, and thread type. Then, find compatible components.

    Drain, Waste, and Vent ABS Pipe Fittings for Chemicals

    These Schedule 40 fittings are an economical option for gravity-flow chemical waste systems. They are ABS plastic, which has excellent strength and impact resistance and good chemical resistance. Fittings meet ASTM D2661, ASTM D3311, ASTM D3965, and ASTM F1498 specifications and testing requirements for material quality and product dimensions.
    To prevent leaks in threaded connections, apply a sealant to the male threads. Threaded connections can be taken apart as needed for maintenance and repair. For metal threads, use PTFE tape. For plastic threads, apply a non-hardening, plastic-compatible sealant. Tape or sealants with PTFE are not recommended for plastic-to-plastic connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
    Warning: Never use plastic pipe fittings, flanges, and pipe with compressed air or gas.
    Tee Connectors
    Image of Product. Front orientation. Pipe and Fittings. Drain, Waste, and Vent ABS Pipe Fittings for Chemicals, Tee Connectors, Cement Socket Female.

    Cement Socket Female

    Cement-Socket Fitting Connection—Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with ABS cement (also known as solvent weld).
    Pipe
    Size
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Each
    Cement Socket Female
    1 1/2
    40
    ABSBlackNot Rated1608T154000000
    2
    40
    ABSBlackNot Rated1608T15500000
    3
    40
    ABSBlackNot Rated1608T15600000
    4
    40
    ABSBlackNot Rated1608T21500000
     
    Pipe Cement
    Short Offset Tee Connectors
    Image of Product. Front orientation. Pipe and Fittings. Drain, Waste, and Vent ABS Pipe Fittings for Chemicals, Short Offset Tee Connectors, Cement Socket Female.

    Cement Socket Female

    Offset tees are also known as sanitary tees and eccentric tees. They have an offset branch so the line can drain. Use them for applications that require frequent cleaning and inspecting.
    Cement-Socket Fitting Connection—Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with ABS cement (also known as solvent weld).
    Pipe
    Size
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Each
    Cement Socket Female
    1 1/4
    40
    ABSBlackNot Rated1608T14800000
    1 1/2
    40
    ABSBlackNot Rated1608T1490000
    2
    40
    ABSBlackNot Rated1608T1510000
    3
    40
    ABSBlackNot Rated1608T15200000
    4
    40
    ABSBlackNot Rated1608T15300000
     
    Pipe Cement
    Long Offset Tee Connectors
    Image of Product. Front orientation. Pipe and Fittings. Drain, Waste, and Vent ABS Pipe Fittings for Chemicals, Long Offset Tee Connectors, Cement Socket Female.

    Cement Socket Female

    Long offset tees are also known as long radius wyes. Offset tees are also known as sanitary tees and eccentric tees. They have an offset branch so the line can drain. Use them for applications that require frequent cleaning and inspecting.
    Cement-Socket Fitting Connection—Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with ABS cement (also known as solvent weld).
    Pipe
    Size
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Each
    Cement Socket Female
    1 1/2
    40
    ABSBlackNot Rated1608T162000000
    2
    40
    ABSBlackNot Rated1608T16300000
    3
    40
    ABSBlackNot Rated1608T16400000
    4
    40
    ABSBlackNot Rated1608T16500000
     
    Pipe Cement
    Inline Offset Tee Reducers
    Image of Product. Front orientation. Pipe and Fittings. Drain, Waste, and Vent ABS Pipe Fittings for Chemicals, Inline Offset Tee Reducers, Cement Socket Female × Cement Socket Female × Cement Socket Female.

    Cement Socket Female

    × Cement Socket

    Female × Cement

    Socket Female

    Inline tees are also known as branch tees. Offset tees are also known as sanitary tees and eccentric tees. They have an offset branch so the line can drain. Use them for applications that require frequent cleaning and inspecting.
    Cement-Socket Fitting Connection—Attach socket-connect ends to unthreaded pipe or another socket-connect fitting with ABS cement (also known as solvent weld).
    Pipe
    Size
    (A)
    (B)
    (C)
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Each
    Cement Socket Female × Cement Socket Female × Cement Socket Female
    2
    1 1/2
    2
    40
    ABSBlackNot Rated1608T15800000
    3
    1 1/2
    3
    40
    ABSBlackNot Rated1608T15900000
    4
    2
    4
    40
    ABSBlackNot Rated1608T16100000
     
    Pipe Cement
    180° Bend Connectors
    Image of Product. Front orientation. Pipe Traps. Drain, Waste, and Vent ABS Pipe Fittings for Chemicals, 180° Bend.

    180° Bend

    180° Bend Connectors—180° bend connectors are also known as U-bends.
    Pipe
    Size
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Shape
    Each
    Cement Socket Female
    1 1/2
    40
    ABSBlackNot Rated180° Bend1608T207000000
     
    Union 270° Bend Connectors
    Image of Product. Front orientation. Pipe Traps. Drain, Waste, and Vent ABS Pipe Fittings for Chemicals, Union 270° Bend.

    Union 270° Bend

    Union 270° Bend Connectors—270° bend fittings are also known as P-traps. They separate into three pieces, so you can access your line.
    Pipe
    Size
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Fitting Type
    Each
    Cement Socket Female
    1 1/4
    40
    ABSBlackNot RatedUnion 270° Bend1608T177000000
    1 1/2
    40
    ABSBlackNot RatedUnion 270° Bend1608T17800000
    2
    40
    ABSBlackNot RatedUnion 270° Bend1608T17900000
     
    Union 270° Bend Adapters
    Image of Product. Front orientation. Pipe Traps. Drain, Waste, and Vent ABS Pipe Fittings for Chemicals, Union 270° Bend Adapter.

    Union 270° Bend Adapter

    Union 270° Bend Adapters—270° bend fittings are also known as P-traps. They separate into three pieces, so you can access your line.
    Pipe
    Size
    Pipe
    Schedule
    Material
    Color
    Max. Pressure
    @ Temp.
    Fitting Type
    Each
    Cement Socket Female × Clamp-On Female
    1 1/2
    40
    ABSBlackNot RatedUnion 270° Bend Adapter1608T176000000
     

    Expansion Plugs for Cleanout Tees

    Image of ProductInUse. Side1 orientation. Contains Inset. Expansion Plugs. Expansion Plugs for Cleanout Tees.
    Seal cleanout tees when testing your drain, waste, and vent systems for pressure and leaks—no need to inflate these plugs with an air compressor or hand pump. To install, insert the plug end into your pipe so the curved foot is on the bottom threads of the cleanout tee, then push down the handle to lock it into the foot. The foot has a two-stage release latch: lift the handle one notch to release the plug and allow liquid to drain slowly, then lift the handle again until the foot fully disengages to take out the plug.
    Maximum Air Back Pressure—Maximum air back pressure is the amount of pressure a plug can withstand without moving.
    Maximum Water Back Pressure—Maximum water back pressure refers to the pressure resulting from the height of the water above the plug.
    For
    Pipe
    Max. Back
    Pressure
    Steel Handle
    Size
    ID
    Air,
    psi
    Water, ft.
    of head
    Overall
    Ht.
    Temp. Range,
    ° F
    Seal Material
    For Use With
    Each
    2
    2.067"651509 1/2"32 to 120Natural Rubber
    ABS Pipe, Cast Iron Pipe, PVC Pipe6568N111000000
    3
    3.068"6515011 3/4"32 to 120Natural Rubber
    ABS Pipe, Cast Iron Pipe, PVC Pipe6568N11200000
    4
    4.026"6515013 1/2"32 to 120Natural Rubber
    ABS Pipe, Cast Iron Pipe, PVC Pipe6568N11300000
    6
    6.065"358018"32 to 120Natural Rubber
    ABS Pipe, Cast Iron Pipe, PVC Pipe6568N201000000
    8
    7.981"204019"32 to 120Natural Rubber
    ABS Pipe, Cast Iron Pipe, PVC Pipe6568N202000000
     
    back to top