About Pipe Size
More
About Pressure Gauges
More
About Pressure Transmitters
More
Absolute Pressure Gauges
Unlike other gauges that measure the difference between your system and the atmosphere, these give measurements relative to zero pressure. They’re often used in laboratory applications, and they are barometrically independent.
Gauges with a Torr scale are also known as Torr gauges.
Stainless steel gauges have excellent corrosion resistance, so they can be used with more corrosive liquids and gasses than gauges with a brass connection and aluminum case.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air
- Accuracy: ±2% Full Scale (Not Graded)
Available Pressure Ranges | |||||
---|---|---|---|---|---|
Numeric Increments | Graduation Marks | ||||
Pressure Range, mbar | Pressure Range, Torr | mbar | Torr | mbar | Torr |
0 to 25 | 0 to 20 | 5 | 2 | 0.5 | 0.2 |
0 to 50 | 0 to 40 | 10 | 10 | 1 | 1 |
0 to 130 | 0 to 100 | 20 | 20 | 2 | 2 |
0 to 1,000 | 0 to 760 | 200 | 100 | 20 | 10 |
Bottom Connection | ||||||
---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Lens Material | Each | |
NPT Male | ||||||
4" | 1/4 | 5° to 120° | 0° to 145° | Glass | 000000 | 0000000 |
- For Use With: Air, Carbon Dioxide, Diesel Fuel, Ethyl Alcohol, Gasoline, Hydraulic Fluid, Natural Gas, Water
- Accuracy: ±1% Full Scale (Not Graded)
Available Pressure Ranges | ||
---|---|---|
Pressure Range, mbar | Numeric Increments, mbar | Graduation Marks, mbar |
0 to 25 | 5 | 0.5 |
0 to 60 | 10 | 1 |
0 to 160 | 50 | 5 |
0 to 600 | 100 | 10 |
0 to 1,000 | 200 | 20 |
Bottom Connection | ||||||
---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Lens Material | Each | |
BSPP Male | ||||||
4" | 1/2 | 5° to 120° | 0° to 200° | Glass | 000000 | 000000000 |
Hand-Held High-Vacuum Gauges
Check the vacuum levels in high-vacuum pumps, valves, and chambers with this compact gauge. Use a ring and clamp (both sold separately) to connect them to another quick-clamp high-vacuum fitting, also known as KF, QF, and NW fittings. The digital display shows measurements in torr, mbar (millibar) and hPa (hectopascal).
- For Use With: Air
- Accuracy: ±10% @ 7.5 to 7.5 × 10 -3 torr, ±30% @ 75 to 7.5 torr
Vacuum Range | ||
---|---|---|
Torr | mbar | hPa |
750 to 7.5 × 10 -5 | 1000 to 5 × 10 -4 | 1000 to 5 × 10 -4 |
Gauges with Center Back Connection | Clamps | Rings | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
High-Vacuum Flange Size | Wd. | Ht. | Dp. | Environment Temp. Range, °F | Process Temp. Range, °F | For Tube OD | Flange OD | Number of Batteries Included | Each | Each | Each | |||
Quick Clamp Tube Connection | ||||||||||||||
16 | 2 3/8" | 4 3/4" | 1" | 40° to 100° | 0° to 140° F | 3/4" | 1.18" | 1 | 000000 | 000000000 | 00000000 | 00000 | 00000000 | 00000 |
Absolute Pressure Transmitters
Monitor and control pressure in portable HVAC systems, hydraulics, and oil and gas equipment. Unlike other pressure transmitters that measure the difference between your system and the atmosphere, these transmitters give measurements relative to zero pressure—regardless of altitude or temperature. Also known as transducers, they convert pressure into an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers (PLCs), and motor speed controls. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range.
All transmitters are rated IP67 for protection from dust and temporary submersion during washdowns. Those that are rated NEMA 4X also protect against weather and corrosion.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
For technical drawings and 3-D models, click on a part number.
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1.5%
- Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material: 316L Stainless Steel
- Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-15 | 30 | 30 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 0000000 |
0-30 | 60 | 60 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-50 | 100 | 100 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-100 | 200 | 200 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-200 | 400 | 400 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-300 | 600 | 600 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
0-500 | 1,000 | 1,000 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1.2%
- Pipe Connection: NPT Female
- Housing Material: Glass-Reinforced Polyester
- Connection Material: Brass
- Temperature Range: -40° to 275° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-75 | 360 | 1,595 | 4.5-5.5V DC | 1/4 | 1 15/16" | 13/16" | IP67 | 0000000 | 000000 |
0-150 | 435 | 1,595 | 4.5-5.5V DC | 1/4 | 1 15/16" | 13/16" | IP67 | 0000000 | 00000 |
0-200 | 550 | 1,595 | 4.5-5.5V DC | 1/4 | 1 15/16" | 13/16" | IP67 | 0000000 | 00000 |
0-265 | 780 | 1,595 | 4.5-5.5V DC | 1/4 | 1 15/16" | 13/16" | IP67 | 0000000 | 00000 |
0-315 | 900 | 1,595 | 4.5-5.5V DC | 1/4 | 1 15/16" | 13/16" | IP67 | 0000000 | 00000 |
0-665 | 1,320 | 2,490 | 4.5-5.5V DC | 1/4 | 1 15/16" | 13/16" | IP67 | 0000000 | 00000 |
Absolute Pressure Transmitters for Development Boards
- For Use With: Air, Argon, Nitrogen, Water
- Accuracy: ±0.25%
- Tube Connection: Unthreaded Male
- Housing Material: Stainless Steel
- Connection Material: Stainless Steel
- Temperature Range: 30° to 120° F
Measure your equipment’s pressure and send the data directly to a development board or single-board computer. Also known as transducers, these transmitters convert pressure into an electrical I2C signal and transmit it to your board by connecting a cord (not included) with a Qwiic connection. Transmitters connect directly to your machinery via tubing (not included), letting you monitor activity such as gas tank pressurization and liquid fill level.
Unlike other pressure transmitters that measure the difference between your system and the atmosphere, these transmitters give measurements relative to zero pressure—regardless of altitude or temperature. They will only provide accurate readings within the rated pressure range.
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | For Tube ID | I2C Address | No. of Qwiic Connections | Ht. | Wd. | Each | |
I2C Communication Protocol—Qwiic Connection | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1-25 | 60 | 60 | 1.8-3.6V DC | 0.1" | 0x18 | 2 | 1" | 1" | 0000000 | 000000 |