About Air Compressors
More
Electric Air Compressors

From lifting heavy objects to mixing large vats, these compressors power the equipment that keeps your production line going. They use pistons to compress air in two stages to generate higher pressures and flow rates than single-stage compressors. This two-step process—compressing air, cooling it, and compressing it again—prevents heat and reduces wear, so you can run them continuously.
When choosing a tank size, keep in mind a larger tank capacity means you won't have to run them continuously, which extends their life. These compressors turn on when tank pressure drops to the actuation point and shut off when it reaches maximum pressure.
If you plan to run them continuously, use SAE 20 synthetic oil (sold separately) to maintain performance and efficiency.
Air Compressors | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Outlet (Female) | Overall | Oil | Replacement Filter Elements | |||||||||||||||
Max. | Actuation | Max. Flow Rate @ psi | Mounting Orientation | Tank Cap., gal. | hp | Full Load Current, A | Volume, dBA | Pipe Size | Thread Type | Lg. | Wd. | Ht. | Each | Container Size | Each | Each | |||
Single Phase, 230V AC | |||||||||||||||||||
175 | 135 | 14.3 cfm @ 90 | Vertical | 60 | 5 | 22.5 | 85 | 1/2 | NPT | 33" | 24" | 69" | 000000000 | 000000000 | 0.5 L | 0000000 | 000000 | 0000000 | 000000 |
Three Phase, 230V AC | |||||||||||||||||||
175 | 135 | 14.3 cfm @ 90 | Vertical | 60 | 5 | 15.2 | 85 | 1/2 | NPT | 33" | 24" | 69" | 000000000 | 00000000 | 0.5 L | 0000000 | 00000 | 0000000 | 00000 |
Three Phase, 460V AC | |||||||||||||||||||
175 | 135 | 14.3 cfm @ 90 | Vertical | 60 | 5 | 7.6 | 85 | 1/2 | NPT | 33" | 24" | 69" | 000000000 | 00000000 | 0.5 L | 0000000 | 00000 | 0000000 | 00000 |
Light Duty Electric Air Compressors

Pressurize air to power drills, wrenches, and grinders. Because they’re single-stage, these compressors are best for infrequent use. They turn on when tank pressure drops to the actuation point and shut off when it reaches maximum pressure. Hardwire them to your power source. Choose a compressor with a tank size that matches your application. The larger the tank, the more tools it can power. A greater reserve of air means the compressor can run less often, which keeps it cool and improves energy efficiency for a longer life.
Compressors for intermittent duty require a cooling period between uses so they don’t overheat.
Compressors for continuous duty can run without a cooling period. They’re designed for applications that require a constant supply of compressed air.
Note: Pair air compressors with the listed oil (sold separately) to extend their service life.
Air Compressors | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Outlet (Female) | Overall | Oil | Replacement Filter Elements | ||||||||||||||||
Max. | Actuation | Max. Flow Rate @ psi | Tank Cap., gal. | hp | Full Load Current, A | Volume, dBA | Pipe Size | Thread Type | Lg. | Wd. | Ht. | Mounting Orientation | Specifications Met | Each | Container Size | Each | Each | |||
Intermittent Duty Cycle (4.5 Minutes On, 5.5 Minutes Off) | ||||||||||||||||||||
Single Phase, 115V AC | ||||||||||||||||||||
125 | 90 | 9.8 cfm @ 125 | 60 | 1 1/2 | 15 | 77 | 1/2 | NPT | 25" | 20" | 66" | Vertical | UL Listed, ASME BPVC.VIII, CSA Certified | 0000000 | 000000000 | 1 qt. | 00000000 | 000000 | 00000000 | 000000 |
125 | 90 | 13.1 cfm @ 125 | 60 | 2 | 20.4 | 77 | 1/2 | NPT | 25" | 20" | 66" | Vertical | UL Listed, ASME BPVC.VIII, CSA Certified | 0000000 | 00000000 | 1 qt. | 00000000 | 00000 | 00000000 | 00000 |
Continuous Duty Cycle | ||||||||||||||||||||
Single Phase, 230V AC | ||||||||||||||||||||
135 | 105 | 11.3 cfm @ 90 | 60 | 3 | 14.7 | 85 | 1/2 | NPT | 25" | 24" | 67" | Vertical | CSA Certified | 0000000 | 00000000 | 0.5 L | 0000000 | 00000 | 0000000 | 00000 |
135 | 105 | 18.1 cfm @ 90 | 60 | 5 | 21.5 | 85 | 1/2 | NPT | 30" | 24" | 73" | Vertical | CSA Certified | 0000000 | 00000000 | 0.5 L | 0000000 | 00000 | 0000000 | 00000 |
Low-Noise Electric Air Compressors

As quiet as an idling forklift, these rotary screw compressors make less noise than traditional piston compressors but deliver the same power. They turn on when tank pressure drops to the actuation point and off when it reaches the maximum. Use them for manufacturing, processing, and packaging jobs where steady output matters—you can run them continuously. If you plan to run them continuously, use SAE 20 synthetic oil (sold separately) to maintain performance and efficiency.
Air Compressors | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Outlet (Female) | Overall | Oil | Replacement Filter Elements | |||||||||||||||
Max. | Actuation | Max. Flow Rate @ psi | hp | Full Load Current | Tank Cap., gal. | Volume, dBA | Pipe Size | Thread Type | Lg. | Wd. | Ht. | Mounting Orientation | Each | Container Size, gal. | Each | Each | |||
Single Phase, 230V AC | |||||||||||||||||||
138 | 115 | 16.7 cfm @ 138 | 5 | 30 A @ 230 V AC | 60 | 62 | 1/2 | NPT | 58" | 26" | 50" | Horizontal | 0000000 | 000000000 | 1 | 0000000 | 0000000 | 0000000 | 000000 |
138 | 115 | 25.2 cfm @ 138 | 7 1/2 | 35 A @ 230 V AC | 60 | 64 | 1/2 | NPT | 58" | 26" | 50" | Horizontal | 0000000 | 00000000 | 1 | 0000000 | 000000 | 0000000 | 00000 |
Three Phase, 208/230/460V AC | |||||||||||||||||||
138 | 115 | 16.8 cfm @ 138 | 5 | 19 A @ 208 V AC 17 A @ 230 V AC 8.5 A @ 460 V AC | 60 | 62 | 1/2 | NPT | 58" | 26" | 50" | Horizontal | 0000000 | 00000000 | 1 | 0000000 | 000000 | 0000000 | 00000 |
138 | 115 | 25.2 cfm @ 138 | 7 1/2 | 26 A @ 208 V AC 23.5 A @ 230 V AC 12 A @ 460 V AC | 60 | 64 | 1/2 | NPT | 58" | 26" | 50" | Horizontal | 0000000 | 00000000 | 1 | 0000000 | 000000 | 0000000 | 00000 |
Economy Electric Air Compressors
Designed with occasional use in mind. These two-stage compressors deliver the same high pressures and flow rates as standard models, but their undersized motor must work twice as hard. They run hotter, louder, and are less durable than more expensive two-stage compressors.
These air compressors turn on when tank pressure drops to the activation point and shut off when it reaches maximum pressure. They can run continuously without needing a cooling period. Use SAE 30 synthetic oil (sold separately) to maintain performance and efficiency.

Air Compressors | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pressure, psi | Outlet (Female) | Overall | Oil | Replacement Filter Elements | |||||||||||||||||
Max. | Actuation | Max. Flow Rate @ psi | hp | Full Load Current, A | Tank Cap., gal. | Volume, dB | Pipe Size | Thread Type | Lg. | Wd. | Ht. | Mounting Orientation | Includes | Specifications Met | Each | Container Size, qt. | Each | Each | |||
Single Phase, 230V AC | |||||||||||||||||||||
175 | 145 | 15.4 cfm @ 100 | 5 | 24 | 60 | 80 | 1/2 | NPT | 31" | 23" | 70" | Vertical | Lubricant, Tank Pressure Gauge | ASME BPVC.VIII, C-UL Listed, UL Listed | 0000000 | 000000000 | 1 | 0000000 | 000000 | 0000000 | 000000 |