McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    71 Products

    Wall-Mount Enclosure-Cooling Air Conditioners

    Image of Product. Front orientation. Air Conditioners. Wall-Mount Enclosure-Cooling Air Conditioners.
    Image of Product. Front orientation. Air Conditioners. Wall-Mount Enclosure-Cooling Air Conditioners.
    Protect equipment in enclosures and cabinets from overheating with chilled air. All of these air conditioners are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping. The internal circuits of these air conditioners are rated IP54. The external circuits of these air conditioners are rated IP34.
    3,600 BTU/hr Cooling Capacity and 5,100 BTU/hr Cooling Capacity—Air conditioners with 3,600 and 5,100 BTU/hr. cooling capacity require two openings for installation.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Features
    Includes
    Enclosure Rating
    Certification
    Each
    With Adjustable Thermostat Control (68° F to 131° F)
     
    120V AC, Single Phase, 60 Hz—Quick-Disconnect Terminal Connection
    1,0002003.321 5/8"11"5 1/2"21 5/8"11"YesCondensate Drain TubeMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    00000000000000000
    2,0001605.721 5/8"11"7 7/8"21 5/8"11"YesCondensate Drain Tube, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
    3,6003501037 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
    5,10047012.537 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
     
    230V AC, Single Phase, 50 Hz/60 Hz—Quick-Disconnect Terminal Connection
    1,0002001.721 5/8"11"5 1/2"21 5/8"11"YesCondensate Drain TubeMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
    2,0001552.621 5/8"11"7 7/8"21 5/8"11"YesCondensate Drain Tube, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
    3,6003504.437 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
    5,100470637 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
    8,0005758.562 3/16"15 3/4"11 3/8"62 1/8"15 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
     
    460V AC, Three Phase, 50 Hz/60 Hz—Quick-Disconnect Terminal Connection
    5,1004702.637 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
    8,000525362 3/16"15 3/4"11 3/8"62 1/8"15 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
     
    Accessories for Air Conditioners

    Top-Mount Enclosure-Cooling Air Conditioners

    Image of Product. Front orientation. Air Conditioners. Top-Mount Enclosure-Cooling Air Conditioners.
    Protect equipment in enclosures and cabinets from overheating with chilled air. All of these air conditioners are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Features
    Includes
    Enclosure Rating
    Certification
    Each
    With Adjustable Thermostat Control (68° F to 131° F)
     
    120V AC, Single Phase, 60 Hz—Quick-Disconnect Terminal Connection
    3,6002858.716 5/16"23 1/2"18 3/4"15 3/8"19 5/16"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    00000000000000000
    5,10028514.116 5/16"23 1/2"18 3/4"15 3/8"19 5/16"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
    7,20027514.216 5/16"23 1/2"18 3/4"15 3/8"19 5/16"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
     

    Remote Control Wall-Mount Enclosure-Cooling Air Conditioners

    Image of Product. Shown with Controller and Adapter. Front orientation. Air Conditioners. Remote Control Wall-Mount Enclosure-Cooling Air Conditioners.

    Shown with Controller and Adapter

    Keep your equipment cool in hard-to-reach enclosures. These air conditioners include an adapter and temperature controller, so you can monitor temperatures and manage settings and alarms remotely. You can integrate them into your facility's network or a programmable logic controller (PLC). If you'd rather control them from your laptop, use their RJ45 connection (cord not included). Use a bracket to mount the adapter and controller to a DIN rail on a nearby panel.
    3,600 BTU/hr Cooling Capacity and 5,100 BTU/hr Cooling Capacity—Air conditioners with 3,600 and 5,100 BTU/hr. cooling capacity require two openings for installation.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Features
    Includes
    Certification
    Each
    With Adjustable Thermostat Control (68° F to 131° F)
     
    120V AC, Single Phase, 60 Hz—Quick-Disconnect Terminal Connection
    1,0002003.321 5/8"11"5 1/2"21 5/8"11"YesCondensate Drain TubeAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
    2,0001605.721 5/8"11"7 7/8"21 5/8"11"YesCondensate Drain Tube, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
    3,6003501037 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
    5,10047012.537 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
     
    230V AC, Single Phase, 50 Hz/60 Hz—Quick-Disconnect Terminal Connection
    1,0002001.721 5/8"11"5 1/2"21 5/8"11"YesCondensate Drain TubeAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
    2,0001552.621 5/8"11"7 7/8"21 5/8"11"YesCondensate Drain Tube, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
    3,6003504.437 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
    5,100470637 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
    8,0005758.562 3/16"15 3/4"11 3/8"62 1/8"15 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
     
    460V AC, Three Phase, 50 Hz/60 Hz—Quick-Disconnect Terminal Connection
    5,1004702.637 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
    8,000525362 3/16"15 3/4"11 3/8"62 1/8"15 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    000000000000000
     
    Air Filters

    Washdown Enclosure-Cooling Air Conditioners

    Image of Product. Front orientation. Air Conditioners. Washdown Enclosure-Cooling Air Conditioners.
    Suitable for washdown applications, these air conditioners are rated NEMA 4X to resist dirt, washdowns, and corrosion. Use them to protect equipment in enclosures and cabinets from overheating with chilled air. The internal circuits of these air conditioners are rated IP55. The external circuits of these air conditioners are rated IP34.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Features
    Includes
    Enclosure Rating
    Certification
    Each
    With Adjustable Thermostat Control (68° F to 131° F)
     
    120V AC, Single Phase, 60 Hz—Quick-Disconnect Terminal Connection
    1,7001605.724 3/8"11 3/16"11 11/16"21 5/8"11"YesYesCondensate Drain Tube, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP55, NEMA 4X
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    00000000000000000
    3,6003501040 3/16"15 7/8"14 1/8"10", 13 3/4"13 3/4", 13 3/4"YesYesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP55, NEMA 4X
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    0000000000000000
     

    Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats

    Image of System. Vortex Tube and Included Parts Shown Installed. Front orientation. Vortex Tubes. Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats.

    Vortex Tube and Included Parts Shown

    Installed

    Cool electronics inside enclosures to your desired temperature while keeping out rain, snow, splashing water, and dirt. After you set the thermostat on these vortex tubes, it works with a solenoid valve to regulate temperature. Cooling turns on and off automatically to cut down on energy use. These vortex tubes use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
    With Adjustable Thermostat Control (-50° F to 200° F)
    Image of Product. Vortex Tube with Adjustable Thermometer. Front orientation. Vortex Tubes. Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats, Adjustable Thermostat Control.
    Image of Product. Replacement Filter. Front orientation. Vortex Tube Filters. Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats.

    Vortex Tube with Adjustable

    Thermometer

    Replacement

    Filter

    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Voltage,
    V AC
    Electrical
    Connection
    Freq.,
    Hz
    Dia.
    Ht.
    For Opening
    Dia.
    Enclosure
    Rating
    Includes
    Each
    Each
    304 Stainless Steel—IP24, NEMA 3R
    20041/8
    NPT
    Male80 to 10064120Wire Leads601 1/8"6 1/2"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    0000000000000000000000000000
    50081/8
    NPT
    Male80 to 10066120Wire Leads601 1/8"6 1/2"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    00000000000000000000000000
    1,100151/4
    NPT
    Male80 to 10072120Wire Leads601 1/2"10"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    00000000000000000000000000
    1,800251/4
    NPT
    Male80 to 10073120Wire Leads601 1/2"10"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    0000000000000000000000000000
    2,100301/4
    NPT
    Male80 to 10074120Wire Leads601 1/2"10"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    0000000000000000000000000000
    2,900401/4
    NPT
    Male80 to 10076120Wire Leads601 1/2"10"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    0000000000000000000000000000
     

    Enclosure Thermostats

    Image of ProductInUse. Adjustable Thermostat (12.6° F Temperature Difference). Front orientation. Thermostats. Enclosure Thermostats, Adjustable Actuation Point, 12.6° F Temperature Difference.

    Adjustable Thermostat

    (12.6° F Temperature

    Difference)

    Image of ProductInUse. Fixed Thermostat. Front orientation. Thermostats. Enclosure Thermostats, Fixed Actuation Point.

    Fixed Thermostat

    Control a single heating or cooling device in your enclosure to keep electronics at a safe operating temperature. Clip them on to a DIN rail and connect them to your heater, fan, or air conditioner. All these thermostats meet American, Canadian, or European safety standards.
    Cooling—Cooling thermostats are normally open, so they’ll switch your fan or air conditioner on when the air in your enclosure reaches the temperature setting.
    Adjustable Actuation Point—Adjustable thermostats let you set the temperature you need.
    Fixed Actuation Point—Fixed thermostats have a fixed temperature setting to prevent tampering or accidental changes.
    IP20 Enclosure Rating—They have an IP20 rating—to prevent shocks, fingers won’t fit inside.
    UL 94 V-0—They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
    Temperature Setting—These thermostats keep the air in your enclosure within a set range. Temperature setting is the high end of the range for both heating and cooling thermostats.
    Temperature Difference—Temperature difference is the difference between the temperature when the thermostat turns your device on and when it turns off. For a heater thermostat with a temperature setting of 50° and an 18° temperature difference, the thermostat will switch your heater on when the temperature goes below 32° and off once the temperature reaches 50°. Thermostats with a lower temperature difference maintain a narrower range of temperatures, but they use more power because they switch on and off more frequently.
    Temp.
    Overall
    Setting
    Difference
    Tolerance
    Voltage
    Current,
    amp
    For DIN
    Rail Ht., mm
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Flammability
    Rating
    Certification
    Each
    Cooling
     
    Adjustable Actuation Point
    14° F to 122° F12.6° F-7° F to 7° F120V AC, 240V AC16352.4"1.3"1.6"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    0000000000000
    32° F to 140° F12.6° F-7° F to 7° F120V AC, 240V AC16352.4"1.3"1.6"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    0000000000000
     
    Fixed Actuation Point
    95° F, 35° C18° F, 10° C-11° F to 11° F/-6° C to 6° C120V AC, 240V AC, 24V DC to 75V DC16351 7/8"1 5/16"1 5/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, UL Recognized Component, VDE Certified
    000000000000
    122° F, 50° C18° F, 10° C-11° F to 11° F/-6° C to 6° C120V AC, 240V AC, 24V DC to 75V DC16351 7/8"1 5/16"1 5/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, UL Recognized Component, VDE Certified
    000000000000
    140° F, 60° C18° F, 10° C-12.6° F to 12.6° F/-7° C to 7° C120V AC, 240V AC, 24V DC to 75V DC16351 7/8"1 5/16"1 5/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, UL Recognized Component, VDE Certified
    000000000000
     

    Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes

    Image of System. Vortex Tube and Included Parts Shown Installed. Front orientation. Vortex Tubes. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes.
    Image of Product. Vortex Tube. Front orientation. Vortex Tubes. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes.
    Image of Product. Replacement Filter. Front orientation. Vortex Tube Filters. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes.

    Vortex Tube and Included Parts Shown

    Installed

    Vortex

    Tube

    Replacement

    Filter

    Quietly cool electronics inside enclosures while keeping out rain, snow, splashing water, and dirt. These vortex tubes have mufflers on both the hot and cold air outlets to reduce noise. They use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Dia.
    Ht.
    For Opening
    Dia.
    Enclosure
    Rating
    Includes
    Each
    Each
    304 Stainless Steel—IP24, NEMA 3R
    20041/8
    NPT
    Male80 to 100582 1/4"12 1/2"2 1/4"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    0000000000000000000000000000
    50081/8
    NPT
    Male80 to 100602 1/4"12 1/2"2 1/4"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    00000000000000000000000000
    1,100151/4
    NPT
    Male80 to 100672 13/16"16"2 13/16"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    00000000000000000000000000
    1,800251/4
    NPT
    Male80 to 100682 13/16"16"2 13/16"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    00000000000000000000000000
    2,100301/4
    NPT
    Male80 to 100682 13/16"16"2 13/16"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    00000000000000000000000000
    2,900401/4
    NPT
    Male80 to 100672 13/16"16"2 13/16"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    00000000000000000000000000
     

    Weather-Resistant Enclosure-Cooling Vortex Tubes

    Image of System. Vortex Tube and Included Parts Shown Installed. Front orientation. Vortex Tubes. Weather-Resistant Enclosure-Cooling Vortex Tubes.
    Image of Product. Vortex Tube. Front orientation. Vortex Tubes. Weather-Resistant Enclosure-Cooling Vortex Tubes.
    Image of Product. Replacement Filter. Front orientation. Vortex Tube Filters. Weather-Resistant Enclosure-Cooling Vortex Tubes.

    Vortex Tube and Included Parts Shown

    Installed

    Vortex

    Tube

    Replacement

    Filter

    Cool electronics inside enclosures while keeping out rain, snow, splashing water, and dirt. These vortex tubes use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Dia.
    Ht.
    For Opening
    Dia.
    Enclosure
    Rating
    Includes
    Each
    Each
    304 Stainless Steel—IP24, NEMA 3R
    20041/8
    NPT
    Male80 to 100641 1/8"6 1/2"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    0000000000000000000000000000
    50081/8
    NPT
    Male80 to 100661 1/8"6 1/2"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    00000000000000000000000000
    1,100151/4
    NPT
    Male80 to 100721 1/2"10"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    00000000000000000000000000
    1,800251/4
    NPT
    Male80 to 100731 1/2"10"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    00000000000000000000000000
    2,100301/4
    NPT
    Male80 to 100741 1/2"10"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    00000000000000000000000000
    2,900401/4
    NPT
    Male80 to 100761 1/2"10"1 1/8"IP24, NEMA 3R
    Automatic Water Drain Filter
    Ducting Kit
    00000000000000000000000000
     

    Enclosure Thermostats for Multiple Devices

    Keep electronics in your enclosure from getting too hot or cold with these thermostats that control two devices at once. Clip them to a DIN rail to install.
    For Heating and Cooling Thermostats with One Actuation Point
    Image of Product. Adjustable Thermostat with One Actuation Point. Front orientation. Thermostats. Enclosure Thermostats for Multiple Devices, 1 Actuation Point, Adjustable Actuation Point.

    Adjustable Thermostat

    with One Actuation Point

    Heating and cooling thermostats control heaters and fans or air conditioners.
    Thermostats with one actuation point, also known as changeover thermostats, switch between heating and cooling so one device is always running. When the temperature in your enclosure gets hotter than the temperature you set, the thermostat will turn on your fan or air conditioner. It goes back to heating once the temperature is reduced by the temperature difference. So for a thermostat with a temperature difference of 9° F, setting it at 60° F means it will heat the enclosure until it reaches 60° F, switch to cooling until it reaches 51° F, and then switch back to heating.
    Adjustable Actuation Point—Adjustable thermostats allow you to set custom temperatures.
    IP20 Enclosure Rating—All thermostats meet IP20, which means they’re designed so fingers can’t fit inside and get shocked.
    UL 94 V-0—They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
    Certification—Thermostats that are CE marked or VDE certified meet European safety standards. UL Recognized Component and C-UL Recognized Component thermostats also meet American and Canadian safety standards.
    Temp., ° F
    Overall
    Setting
    Difference
    Tolerance
    Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Flammability
    Rating
    Certification
    Each
    Adjustable Actuation Point
    40 to 1409-5.4 to 3.61202 5/8"2"1 1/2"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, UL Recognized Component
    0000000000000
    40 to 1409-5.4 to 3.62402 5/8"2"1 1/2"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, UL Recognized Component
    000000000000
     
    For Heating and Cooling Thermostats with Two Actuation Points
    Image of Product. Adjustable Thermostat with Two Actuation Points. Front orientation. Thermostats. Enclosure Thermostats for Multiple Devices, 2 Actuation Points, Adjustable Actuation Point.
    Image of Product. Fixed Thermostat. Front orientation. Thermostats. Enclosure Thermostats for Multiple Devices, 2 Actuation Points, Fixed Actuation Point.

    Adjustable Thermostat

    with Two Actuation Points

    Fixed Thermostat

    Cooling thermostats regulate two cooling devices, such as a fan and an air conditioner, for two-stage cooling. Use only one device for cooling in mild temperatures or both for extreme heat. These thermostats switch your equipment on when the enclosure is hotter than the temperature setting. Once the temperature is reduced by the temperature difference, it will switch off. For example, a thermostat set at 77° F for a fan and 140° F for an air conditioner will power both devices when the enclosure is over 140° F. With a temperature difference of 18° F, the air conditioner will switch off when the temperature goes below 122° F. The fan will run until the temperature reaches 59° F, and switch back on if it heats up to 77° F or hotter.
    Heating and cooling thermostats control heaters and fans or air conditioners.
    Heating and cooling thermostats with two actuation points control two devices independently. When your enclosure temperature is within the set range, neither device is powered, so they’re more efficient than changeover thermostats. For each device, temperature setting is the high end of the temperature range, and temperature difference is the size of the range. For a thermostat with temperature settings of 59° and 95° F and an 18° F temperature difference, the heater will switch on when your enclosure is colder than 41° F and turn off when it reaches 59° F. The fan or other cooling device will switch on when the temperature goes above 95° F and turn off once the enclosure cools to 77° F.
    Adjustable Actuation Point—Adjustable thermostats allow you to set custom temperatures.
    Fixed Actuation Point—Fixed thermostats prevent tampering and accidental changes.
    IP20 Enclosure Rating—All thermostats meet IP20, which means they’re designed so fingers can’t fit inside and get shocked.
    UL 94 V-0—They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
    Certification—Thermostats that are CE marked or VDE certified meet European safety standards. UL Recognized Component and C-UL Recognized Component thermostats also meet American and Canadian safety standards.
    Heating Temperature
    Cooling Temperature
    Overall
    Setting
    Difference
    Tolerance
    Setting
    Difference
    Tolerance
    Voltage
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Flammability
    Rating
    Certification
    Each
    Adjustable Actuation Point
    14° F to 122° F12.6° F-7° F to 7° F68° F to 176° F12.6° F-7° F to 7° F120V AC, 240V AC2 5/8"2"1 13/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    0000000000000
    32° F to 140° F12.6° F-7° F to 7° F32° F to 140° F12.6° F-7° F to 7° F120V AC, 240V AC2 5/8"2"1 13/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    000000000000
     
    Fixed Actuation Point
    59° F, 15° C18° F, 10° C-9° F to 9° F, -5° C to 5° C95° F, 35° C18° F, 10° C-12.6° F to 12.6° F, -7° C to 7° C120V AC, 240V AC, 24V DC to 75V DC1 7/8"2 1/2"1 5/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, UL Recognized Component, VDE Certified
    000000000000
    59° F, 15° C18° F, 10° C-9° F to 9° F, -5° C to 5° C122° F, 50° C18° F, 10° C-12.6° F to 12.6° F, -7° C to 7° C120V AC, 240V AC, 24V DC to 75V DC1 7/8"2 1/2"1 5/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, UL Recognized Component, VDE Certified
    000000000000
    77° F, 25° C18° F, 10° C-9° F to 9° F, -5° C to 5° C122° F, 50° C18° F, 10° C-12.6° F to 12.6° F, -7° C to 7° C120V AC, 240V AC, 24V DC to 75V DC1 7/8"2 1/2"1 5/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, UL Recognized Component, VDE Certified
    000000000000
     
    For Cooling Thermostats with Two Actuation Points
    Image of Product. Adjustable Thermostat with Two Actuation Points. Front orientation. Thermostats. Enclosure Thermostats for Multiple Devices, 2 Actuation Points, Adjustable Actuation Point.

    Adjustable Thermostat

    with Two Actuation Points

    Image of Product. Fixed Thermostat. Front orientation. Thermostats. Enclosure Thermostats for Multiple Devices, 2 Actuation Points, Fixed Actuation Point.

    Fixed Thermostat

    Cooling thermostats regulate two cooling devices, such as a fan and an air conditioner, for two-stage cooling. Use only one device for cooling in mild temperatures or both for extreme heat. These thermostats switch your equipment on when the enclosure is hotter than the temperature setting. Once the temperature is reduced by the temperature difference, it will switch off. For example, a thermostat set at 77° F for a fan and 140° F for an air conditioner will power both devices when the enclosure is over 140° F. With a temperature difference of 18° F, the air conditioner will switch off when the temperature goes below 122° F. The fan will run until the temperature reaches 59° F, and switch back on if it heats up to 77° F or hotter.
    Adjustable Actuation Point—Adjustable thermostats allow you to set custom temperatures.
    Fixed Actuation Point—Fixed thermostats prevent tampering and accidental changes.
    IP20 Enclosure Rating—All thermostats meet IP20, which means they’re designed so fingers can’t fit inside and get shocked.
    UL 94 V-0—They also meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping.
    Certification—Thermostats that are CE marked or VDE certified meet European safety standards. UL Recognized Component and C-UL Recognized Component thermostats also meet American and Canadian safety standards.
    Cooling Temperature
    Cooling Temperature
    Second Actuation Point
    Overall
    Setting
    Difference
    Tolerance
    Setting
    Difference
    Tolerance
    Voltage
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Flammability
    Rating
    Certification
    Each
    Adjustable Actuation Point
    32° F to 140° F12.6° F-7° F to 7° F32° F to 140° F12.6° F-7° F to 7° F120V AC, 240V AC2 5/8"2"1 13/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, CSA Certified, UL Recognized Component, VDE Certified
    0000000000000
     
    Fixed Actuation Point
    122° F, 50° C18° F, 10° C-12.6° F to 12.6° F, -7° C to 7° C140° F, 60° C18° F, 10° C-12.6° F to 12.6° F, -7° C to 7° C120V AC, 240V AC, 24V DC to 75V DC1 7/8"2 1/2"1 5/16"IP20
    UL 94 V-0
    C-UL Recognized Component, CE Marked, UL Recognized Component, VDE Certified
    000000000000
     

    Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats

    Image of System. Vortex Tube and Included Parts Shown Installed. Front orientation. Vortex Tubes. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats.

    Vortex Tube and Included Parts Shown

    Installed

    Quietly cool electronics inside enclosures to your desired temperature while keeping out rain, snow, splashing water, and dirt. After you set the thermostat on these vortex tubes, it works with a solenoid valve to regulate temperature. Cooling turns on and off automatically to cut down on energy use. These vortex tubes have mufflers on both the hot and cold air outlets to reduce noise. Using compressed air, they’re a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
    With Adjustable Thermostat Control (-50° F to 200° F)
    Image of Product. Vortex Tube with Adjustable Thermometer. Front orientation. Vortex Tubes. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats, Adjustable Thermostat Control.
    Image of Product. Replacement Filter. Front orientation. Vortex Tube Filters. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats.

    Vortex Tube with Adjustable

    Thermometer

    Replacement

    Filter

    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Voltage,
    V AC
    Electrical
    Connection
    Freq.,
    Hz
    Dia.
    Ht.
    For Opening
    Dia.
    Enclosure
    Rating
    Includes
    Each
    Each
    304 Stainless Steel—IP24, NEMA 3R
    20041/8
    NPT
    Male80 to 10058120Wire Leads602 1/4"12 1/2"2 1/4"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    000000000000000000000000000000
    50081/8
    NPT
    Male80 to 10060120Wire Leads602 1/4"12 1/2"2 1/4"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    0000000000000000000000000000
    1,100151/4
    NPT
    Male80 to 10067120Wire Leads602 13/16"16"2 13/16"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    0000000000000000000000000000
    1,800251/4
    NPT
    Male80 to 10068120Wire Leads602 13/16"16"2 13/16"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    0000000000000000000000000000
    2,100301/4
    NPT
    Male80 to 10068120Wire Leads602 13/16"16"2 13/16"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    0000000000000000000000000000
    2,900401/4
    NPT
    Male80 to 10069120Wire Leads602 13/16"16"2 13/16"IP24, NEMA 3R
    Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    0000000000000000000000000000
     
    back to top