McMaster-Carr logo
    Filter by
    Electrical Phase
    Frequency
    Power Source
    NEMA Type
    Industrial Info Compare
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    114 Products

    Wall-Mount Enclosure-Cooling Air Conditioners

    Image of Product. Front orientation. Air Conditioners. Wall-Mount Enclosure-Cooling Air Conditioners.
    Image of Product. Front orientation. Air Conditioners. Wall-Mount Enclosure-Cooling Air Conditioners.
    Protect equipment in enclosures and cabinets from overheating with chilled air. All of these air conditioners are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping. The internal circuits of these air conditioners are rated IP54. The external circuits of these air conditioners are rated IP34.
    3,600 BTU/hr Cooling Capacity and 5,100 BTU/hr Cooling Capacity—Air conditioners with 3,600 and 5,100 BTU/hr. cooling capacity require two openings for installation.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Features
    Includes
    Enclosure Rating
    Certification
    Each
    With Adjustable Thermostat Control (68° F to 131° F)
     
    120V AC, Single Phase, 60 Hz—Quick-Disconnect Terminal Connection
    1,0002003.321 5/8"11"5 1/2"21 5/8"11"YesCondensate Drain TubeMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K19000000000
    2,0001605.721 5/8"11"7 7/8"21 5/8"11"YesCondensate Drain Tube, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K2100000000
    3,6003501037 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K2200000000
    5,10047012.537 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K2300000000
     
    230V AC, Single Phase, 50 Hz/60 Hz—Quick-Disconnect Terminal Connection
    1,0002001.721 5/8"11"5 1/2"21 5/8"11"YesCondensate Drain TubeMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K2500000000
    2,0001552.621 5/8"11"7 7/8"21 5/8"11"YesCondensate Drain Tube, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K2600000000
    3,6003504.437 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K2700000000
    5,100470637 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K3100000000
    8,0005758.562 3/16"15 3/4"11 3/8"62 1/8"15 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K3300000000
     
    460V AC, Three Phase, 50 Hz/60 Hz—Quick-Disconnect Terminal Connection
    5,1004702.637 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K3200000000
    8,000525362 3/16"15 3/4"11 3/8"62 1/8"15 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K3400000000
     
    Accessories for Air Conditioners

    Window Air Conditioners

    Image of Product. Front orientation. Air Conditioners. Window Air Conditioners.
    Image of Specification. Front orientation. NEMA 6-15.

    NEMA

    6-15

    Mount these air conditioners in a window. Adjust the louvers to direct airflow. The higher the combined energy efficiency ratio, the more energy efficient the unit. Your operating costs will depend on your utility rates and use. The estimated yearly energy cost is based on electricity cost of $0.12 per kWh. For more information, visit www.ftc.gov/energy.
    Cannot Be Sold To—Air conditioners cannot be sold to the listed areas due to chemical regulations.
    Overall
    Cooling Cap.,
    BTU/hr
    Combined Energy
    Efficiency Ratio
    Est. Yearly
    Energy Cost
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Features
    For Window
    Wd.
    Certification
    NEMA
    Type
    Cannot Be Sold To
    Each
    With Adjustable Thermostat Control (60° F to 90° F)
     
    208V AC to 230V AC, Single Phase—Three-Blade Plug
    21,50010.3$202.004259.317 15/16"25 15/16"29"Adjustable Louvers27 3/8" to 42"C-UL Listed, UL Listed
    6-15
    California, Canada, Washington1843K51000000000
     

    Through-the-Wall Air Conditioners

    Image of Product. Front orientation. Air Conditioners. Through-the-Wall Air Conditioners.
    Image of Specification. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Install these air conditioners in an opening in an exterior wall. Adjust the louvers to direct airflow. The higher the combined energy efficiency ratio, the more energy efficient the unit. Your operating costs will depend on your utility rates and use. The estimated yearly energy cost is based on electricity cost of $0.13 per kWh. For more information, visit www.ftc.gov/energy.
    Cannot Be Sold To—Air conditioners cannot be sold to the listed areas due to chemical regulations.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Combined Energy
    Efficiency Ratio
    Est. Yearly
    Energy Cost
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Features
    Certification
    NEMA
    Type
    Cannot Be Sold To
    Each
    With Adjustable Thermostat Control (60° F to 90° F)
     
    120V AC, Single Phase—Three-Blade Plug
    11,60010.5$107.0029510.516 3/4"27"24 1/4"16 3/4"27"Adjustable LouversC-UL Listed, UL Listed
    5-15
    California, Canada, Washington1843K92000000000
     
    Air Conditioner Mounts

    Mobile Evaporative Air Coolers

    Image of Product. Front orientation. Evaporative Air Coolers. Mobile Evaporative Air Coolers.
    Image of Specification. Front orientation. NEMA 5-15. Mobile Evaporative Air Coolers.

    NEMA

    5-15

    Also known as swamp coolers, use these air coolers wherever air conditioning is impractical. They take in water, which soaks into pads. When air is blown through the wet pads, the evaporation produces cool air. These air coolers have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. All have a NEMA 5-15 plug, which is a standard three-prong plug.
    Air Coolers
    Replacement Pads
    Replacement
    Pumps
    Overall
    Inlet
    Hose
    Pads
    Airflow,
    ft³/min
    Reservoir
    Cap., gal.
    No. of
    Speeds
    Power,
    hp
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Size
    Thread
    Type
    Housing
    Material
    No.
    Required
    No.
    Included
    Each
    Pkg.
    Qty.
    Pkg.
    Each
    120V AC, Single Phase—NEMA 5-15, 3-Blade Plug In
    3,10010.3Variable1/52.438"24"16"3/4GHT
    Plastic332073K68000000032073K6810000002073K682000000
    5,30014 3/5Variable1/34.346"28"17"3/4GHT
    Plastic442073K6900000042073K691000002073K69200000
     

    Washdown Enclosure-Cooling Air Conditioners

    Image of Product. Front orientation. Air Conditioners. Washdown Enclosure-Cooling Air Conditioners.
    Suitable for washdown applications, these air conditioners are rated NEMA 4X to resist dirt, washdowns, and corrosion. Use them to protect equipment in enclosures and cabinets from overheating with chilled air. The internal circuits of these air conditioners are rated IP55. The external circuits of these air conditioners are rated IP34.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Features
    Includes
    Enclosure Rating
    Certification
    Each
    With Adjustable Thermostat Control (68° F to 131° F)
     
    120V AC, Single Phase, 60 Hz—Quick-Disconnect Terminal Connection
    1,7001605.724 3/8"11 3/16"11 11/16"21 5/8"11"YesYesCondensate Drain Tube, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP55, NEMA 4X
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K41000000000
    3,6003501040 3/16"15 7/8"14 1/8"10", 13 3/4"13 3/4", 13 3/4"YesYesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP55, NEMA 4X
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K4300000000
     

    High-Output Mobile Evaporative Air Coolers

    Image of Product. Front orientation. Evaporative Air Coolers. High-Output Mobile Evaporative Air Coolers, 6,700 ft³/min Airflow.
    Image of Product. Front orientation. Evaporative Air Coolers. High-Output Mobile Evaporative Air Coolers, 13,250 ft³/min Airflow.
    Image of Product. Front orientation. Evaporative Air Coolers. High-Output Mobile Evaporative Air Coolers, 22,000 ft³/min Airflow.
    Image of Specification. Front orientation. NEMA 5-15. High-Output Mobile Evaporative Air Coolers.

    6,700 ft³/min Airflow

    13,250 ft³/min Airflow

    22,000 ft³/min Airflow

    NEMA

    5-15

    Produce twice as much cool air as standard mobile evaporative air coolers. Also known as swamp coolers, use these air coolers wherever air conditioning is impractical. They take in water, which soaks into pads. When air is blown through the wet pads, the evaporation produces cool air.
    Replacement Pads—Replacement pads are sold separately.
    Air Coolers
    Replacement Pads
    Overall
    Inlet
    Hose
    Pads
    Blade
    Dia.
    Airflow,
    ft³/min
    Reservoir
    Cap., gal.
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Size
    Thread
    Type
    Housing
    Material
    No.
    Required
    No.
    Included
    Each
    Pkg.
    Qty.
    Pkg.
    120V AC, Single Phase—NEMA 5-15, 3-Blade Plug In
    24"6,700451,200Variable1/2868"54"30"3/4GHT
    Plastic442073K9100000000042073K9110000000
    36"13,25055810Variable3/4977"63"33"3/4GHT
    Plastic552073K920000000052073K921000000
    48"22,000661,900Variable114.790"78"39"3/4GHT
    Plastic662073K930000000062073K931000000
     

    Top-Mount Enclosure-Cooling Air Conditioners

    Image of Product. Front orientation. Air Conditioners. Top-Mount Enclosure-Cooling Air Conditioners.
    Protect equipment in enclosures and cabinets from overheating with chilled air. All of these air conditioners are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Features
    Includes
    Enclosure Rating
    Certification
    Each
    With Adjustable Thermostat Control (68° F to 131° F)
     
    120V AC, Single Phase, 60 Hz—Quick-Disconnect Terminal Connection
    3,6002858.716 5/16"23 1/2"18 3/4"15 3/8"19 5/16"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K12000000000
    5,10028514.116 5/16"23 1/2"18 3/4"15 3/8"19 5/16"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K1300000000
    7,20027514.216 5/16"23 1/2"18 3/4"15 3/8"19 5/16"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayMounting Bracket, Mounting TemplateIP34, IP54, NEMA 12
    C-UL Recognized Component, CSA Certified, UL Recognized Component
    17495K2900000000
     

    Remote Control Wall-Mount Enclosure-Cooling Air Conditioners

    Image of Product. Shown with Controller and Adapter. Front orientation. Air Conditioners. Remote Control Wall-Mount Enclosure-Cooling Air Conditioners.

    Shown with Controller and Adapter

    Keep your equipment cool in hard-to-reach enclosures. These air conditioners include an adapter and temperature controller, so you can monitor temperatures and manage settings and alarms remotely. You can integrate them into your facility's network or a programmable logic controller (PLC). If you'd rather control them from your laptop, use their RJ45 connection (cord not included). Use a bracket to mount the adapter and controller to a DIN rail on a nearby panel.
    3,600 BTU/hr Cooling Capacity and 5,100 BTU/hr Cooling Capacity—Air conditioners with 3,600 and 5,100 BTU/hr. cooling capacity require two openings for installation.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Features
    Includes
    Certification
    Each
    With Adjustable Thermostat Control (68° F to 131° F)
     
    120V AC, Single Phase, 60 Hz—Quick-Disconnect Terminal Connection
    1,0002003.321 5/8"11"5 1/2"21 5/8"11"YesCondensate Drain TubeAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N11000000000
    2,0001605.721 5/8"11"7 7/8"21 5/8"11"YesCondensate Drain Tube, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N1200000000
    3,6003501037 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N1300000000
    5,10047012.537 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N1400000000
     
    230V AC, Single Phase, 50 Hz/60 Hz—Quick-Disconnect Terminal Connection
    1,0002001.721 5/8"11"5 1/2"21 5/8"11"YesCondensate Drain TubeAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N1500000000
    2,0001552.621 5/8"11"7 7/8"21 5/8"11"YesCondensate Drain Tube, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N1600000000
    3,6003504.437 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N1700000000
    5,100470637 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N1800000000
    8,0005758.562 3/16"15 3/4"11 3/8"62 1/8"15 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N1900000000
     
    460V AC, Three Phase, 50 Hz/60 Hz—Quick-Disconnect Terminal Connection
    5,1004702.637 3/8"15 3/4"10 3/16"10", 13 3/4"13 3/4", 13 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N2100000000
    8,000525362 3/16"15 3/4"11 3/8"62 1/8"15 3/4"YesIntegrated Condensate Evaporator, Programmable Alarm, Temperature DisplayAdapter, Mounting Bracket, Mounting Template, RJ12 Adapter Cord, Temperature Controller, USB Controller CordC-UL Recognized Component, CSA Certified, UL Recognized Component
    5601N2200000000
     
    Air Filters

    Quiet Enclosure-Cooling Vortex Tubes with Thermostats

    Often used in quiet environments such as labs and clean rooms, these are quieter than standard enclosure-cooling vortex tubes. Set the thermostat and the tubes switch on only when needed. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure. All are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
    With Fixed Thermostat Control (80° F to 90° F)
    Image of Product. Front orientation. Vortex Tubes. Quiet Enclosure-Cooling Vortex Tubes with Thermostats.
    Dual Air Outlets—Vortex tubes with dual air outlets have a higher cooling capacity than other vortex tubes. Use them to cool large enclosures and electronics that generate significant heat. Direct the two air streams independently for targeted cooling. With two air mufflers and two ducting lines, these vortex tubes take up slightly more space in your enclosure than vortex tubes with one air outlet.
    Replacement Filters—Replacement filters are sold separately.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Ht.
    Wd.
    Dp.
    Includes
    Each
    Each
    Plastic—NEMA 12
    900153/8
    NPT
    Female90 to 100608"4 3/4"3 9/16"Ducting Kit
    Inline Compressed Air Filter
    1754K4300000001754K520000000
    1,500253/8
    NPT
    Female90 to 100668"4 3/4"3 9/16"Ducting Kit
    Inline Compressed Air Filter
    1754K440000001754K52000000
    2,500353/8
    NPT
    Female90 to 100728"4 3/4"3 9/16"Ducting Kit
    Inline Compressed Air Filter
    1754K450000001754K52000000
    5,000703/8
    NPT
    Female90 to 100758"4 3/4"3 9/16"Dual Air Outlets
    Ducting Kit
    Inline Compressed Air Filter
    1754K61000000001754K56000000
     

    Enclosure-Cooling Vortex Tubes

    Image of Product. Front orientation. Vortex Tubes. Enclosure-Cooling Vortex Tubes.
    Vortex tubes convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure. All are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
    Replacement Filters—Replacement filters are sold separately.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Dia.
    Ht.
    For Opening
    Dia.
    Includes
    Each
    Each
    Aluminum—NEMA 12
    40051/8
    NPT
    Male80 to 100537/8"7 1/16"1 1/8"Ducting Kit
    Inline Compressed Air Filter
    1754K2900000001754K520000000
    900151/4
    NPT
    Female80 to 100751 3/4"10 3/4"1 1/8"Ducting Kit
    Inline Compressed Air Filter
    1754K270000001754K52000000
    1,500251/4
    NPT
    Female80 to 100751 3/4"10 3/4"1 1/8"Ducting Kit
    Inline Compressed Air Filter
    1754K320000001754K52000000
    2,500351/4
    NPT
    Female80 to 100851 3/4"10 3/4"1 1/8"Ducting Kit
    Inline Compressed Air Filter
    1754K250000001754K52000000
     

    Enclosure-Cooling Vortex Tubes with Thermostats

    Set the thermostat and these vortex tubes switch on only when needed. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure. All are rated NEMA 12 to resist dirt, light water splashes, and oil/coolant dripping.
    With Adjustable Thermostat Control (50° F to 140° F)
    Image of Product. Front orientation. Vortex Tubes. Enclosure-Cooling Vortex Tubes with Thermostats.
    Replacement Filters—Replacement filters are sold separately.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Voltage,
    V AC
    Electrical
    Connection
    Freq.,
    Hz
    Dia.
    Ht.
    For Opening
    Dia.
    Includes
    Each
    Each
    Aluminum—NEMA 12
    40051/8
    NPT
    Male80 to 10053120Wire Leads607/8"7 1/16"1 1/8"Ducting Kit
    Inline Compressed Air Filter
    1754K280000000001754K520000000
    900151/4
    NPT
    Female80 to 10075120Wire Leads601 3/4"10 3/4"1 1/8"Ducting Kit
    Inline Compressed Air Filter
    1754K26000000001754K52000000
    1,500251/4
    NPT
    Female80 to 10075120Wire Leads601 3/4"10 3/4"1 1/8"Ducting Kit
    Inline Compressed Air Filter
    1754K33000000001754K52000000
    2,500351/4
    NPT
    Female80 to 10085120Wire Leads601 3/4"10 3/4"1 1/8"Ducting Kit
    Inline Compressed Air Filter
    1754K24000000001754K52000000
     

    Quiet Washdown Enclosure-Cooling Vortex Tubes with Thermostats

    In addition to being quieter than standard enclosure-cooling vortex tubes, these stand up to washdowns and weather. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. Set the thermostat and the tubes switch on only when needed. All include a ducting kit to distribute cool air throughout the enclosure and air mufflers to reduce noise. They also have an inline compressed air filter, which prevents moisture from building up inside the enclosure to further safeguard electronics.
    With Mechanical Fixed Thermostat Control (70° F to 100° F)
    Image of Product. Front orientation. Vortex Tubes. Quiet Washdown Enclosure-Cooling Vortex Tubes with Thermostats, Fixed Thermostat Control, Mechanical.
    Image of Product. Front orientation. Vortex Tubes. Quiet Washdown Enclosure-Cooling Vortex Tubes with Thermostats, Fixed Thermostat Control, Mechanical, Dual Air Outlets.

    Dual Air Outlets

    Dual Air Outlets—Vortex tubes with dual air outlets have a higher cooling capacity than other vortex tubes. Use them to cool large enclosures and electronics that generate significant heat. Direct the two air streams independently for targeted cooling. With two air mufflers and two ducting lines, these vortex tubes take up slightly more space in your enclosure than vortex tubes with one air outlet.
    Replacement Filters—Replacement filters are sold separately.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Ht.
    Wd.
    Dp.
    For Opening
    Dia.
    Features
    Each
    Each
    Plastic—NEMA 4
    900153/8
    NPT
    Female90 to 100608"4 3/4"5 3/8"1 15/16"7814N110000000001754K520000000
    1,500253/8
    NPT
    Female90 to 100668"4 3/4"5 3/8"1 15/16"7814N12000000001754K52000000
    2,500353/8
    NPT
    Female90 to 100728"4 3/4"5 3/8"1 15/16"7814N13000000001754K52000000
    5,000703/8
    NPT
    Female90 to 100756 3/8"9 1/2"5 1/2"1 15/16"Dual Air Outlets7814N14000000001754K56000000
     
    With Electric Adjustable Thermostat Control (35° F to 140° F)
    Image of Product. Front orientation. Vortex Tubes. Quiet Washdown Enclosure-Cooling Vortex Tubes with Thermostats, Adjustable Thermostat Control, Electric.
    Vortex tubes with an electric thermostat require a 120V AC outlet.
    For Internal Outlets—Those with an internal outlet are best for areas where external outlets are not available or where it would be unsafe to have an external electrical connection.
    For External Outlets—Choose those with an external outlet if you need separate electrical connections for the thermostat and the electronics within an enclosure.
    Replacement Filters—Replacement filters are sold separately.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    For
    Internal Outlets
    For
    External Outlets
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Voltage,
    V AC
    Electrical
    Connection
    Ht.
    Wd.
    Dp.
    For Opening
    Dia.
    Each
    Each
    Each
    Plastic—NEMA 4X
    900153/8
    NPT
    Female40 to 15062, 68120Straight Blade6 7/16"9 7/16"5 9/16"1 15/16"7814N180000000007814N150000000001754K520000000
    1,500253/8
    NPT
    Female40 to 15062120Straight Blade6 7/16"9 7/16"5 9/16"1 15/16"7814N19000000007814N16000000001754K52000000
    2,500353/8
    NPT
    Female40 to 15062120Straight Blade6 7/16"9 7/16"5 9/16"1 15/16"7814N21000000007814N17000000001754K52000000
     

    Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats

    Image of System. Vortex Tube and Included Parts Shown Installed. Front orientation. Vortex Tubes. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats.

    Vortex Tube and Included Parts Shown

    Installed

    Quietly cool electronics inside enclosures to your desired temperature while keeping out rain, snow, splashing water, and dirt. After you set the thermostat on these vortex tubes, it works with a solenoid valve to regulate temperature. Cooling turns on and off automatically to cut down on energy use. These vortex tubes have mufflers on both the hot and cold air outlets to reduce noise. Using compressed air, they’re a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
    With Adjustable Thermostat Control (-50° F to 200° F)
    Image of Product. Vortex Tube with Adjustable Thermometer. Front orientation. Vortex Tubes. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats, Adjustable Thermostat Control.
    Image of Product. Replacement Filter. Front orientation. Vortex Tube Filters. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats.

    Vortex Tube with Adjustable

    Thermometer

    Replacement

    Filter

    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Voltage,
    V AC
    Electrical
    Connection
    Freq.,
    Hz
    Dia.
    Ht.
    For Opening
    Dia.
    Includes
    Each
    Each
    304 Stainless Steel—IP24, NEMA 3R
    20041/8
    NPT
    Male80 to 10058120Wire Leads602 1/4"12 1/2"2 1/4"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    7276N110000000007273N990000000
    50081/8
    NPT
    Male80 to 10060120Wire Leads602 1/4"12 1/2"2 1/4"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    7276N12000000007273N99000000
    1,100151/4
    NPT
    Male80 to 10067120Wire Leads602 13/16"16"2 13/16"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    7276N13000000007273N99000000
    1,800251/4
    NPT
    Male80 to 10068120Wire Leads602 13/16"16"2 13/16"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    7276N14000000007273N99000000
    2,100301/4
    NPT
    Male80 to 10068120Wire Leads602 13/16"16"2 13/16"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    7276N15000000007273N99000000
    2,900401/4
    NPT
    Male80 to 10069120Wire Leads602 13/16"16"2 13/16"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    Solenoid Valve
    7276N16000000007273N99000000
     

    Washdown Enclosure-Cooling Vortex Tubes with Thermostats

    Set the thermostat and these vortex tubes switch on only when needed. Suitable for washdown applications, they are NEMA rated to resist washdowns. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure.
    With Fixed Thermostat Control (80° F to 90° F)
    Image of Product. Front orientation. Vortex Tubes. Washdown Enclosure-Cooling Vortex Tubes with Thermostats.
    NEMA 4 Enclosure Rating—NEMA 4 rated vortex tubes resist dirt and washdowns.
    Replacement Filters—Replacement filters are sold separately.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume
    Dia.
    Ht.
    For Opening
    Dia.
    Includes
    Each
    Each
    Aluminum—NEMA 4
    900151/4
    NPT
    Female80 to 10060 dBA to 79 dBA2 1/8"6 3/4"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K340000000001754K520000000
    1,500251/4
    NPT
    Female80 to 10060 dBA to 79 dBA2 1/8"6 3/4"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K31000000001754K52000000
    2,500351/4
    NPT
    Female80 to 10060 dBA to 79 dBA2 1/8"6 3/4"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K35000000001754K52000000
     
    With Adjustable Thermostat Control (50° F to 140° F)
    Image of Product. Front orientation. Vortex Tubes. Washdown Enclosure-Cooling Vortex Tubes with Thermostats.
    NEMA 4 Enclosure Rating—NEMA 4 rated vortex tubes resist dirt and washdowns.
    NEMA 4X Enclosure Rating—NEMA 4X rated vortex tubes resist dirt, washdowns, and corrosion.
    Replacement Filters—Replacement filters are sold separately.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Voltage,
    V AC
    Electrical
    Connection
    Freq.,
    Hz
    Dia.
    Ht.
    For Opening
    Dia.
    Includes
    Each
    Each
    Aluminum—NEMA 4
    900151/4
    NPT
    Female80 to 10071120Wire Leads602"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    8040N130000000001754K520000000
    1,700251/4
    NPT
    Female80 to 10084120Wire Leads602"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    8040N14000000001754K52000000
    2,500351/4
    NPT
    Female80 to 10088120Wire Leads602"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K37000000001754K52000000
     
    304 Stainless Steel—NEMA 4X
    900151/4
    NPT
    Female80 to 10071120Wire Leads602"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    8040N11000000001754K52000000
    1,700251/4
    NPT
    Female80 to 10084120Wire Leads602"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K23000000001754K52000000
    2,500351/4
    NPT
    Female80 to 10088120Wire Leads602"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    8040N12000000001754K52000000
     

    Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats

    Image of System. Vortex Tube and Included Parts Shown Installed. Front orientation. Vortex Tubes. Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats.

    Vortex Tube and Included Parts Shown

    Installed

    Cool electronics inside enclosures to your desired temperature while keeping out rain, snow, splashing water, and dirt. After you set the thermostat on these vortex tubes, it works with a solenoid valve to regulate temperature. Cooling turns on and off automatically to cut down on energy use. These vortex tubes use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
    With Adjustable Thermostat Control (-50° F to 200° F)
    Image of Product. Vortex Tube with Adjustable Thermometer. Front orientation. Vortex Tubes. Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats, Adjustable Thermostat Control.
    Image of Product. Replacement Filter. Front orientation. Vortex Tube Filters. Weather-Resistant Enclosure-Cooling Vortex Tubes with Thermostats.

    Vortex Tube with Adjustable

    Thermometer

    Replacement

    Filter

    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Voltage,
    V AC
    Electrical
    Connection
    Freq.,
    Hz
    Dia.
    Ht.
    For Opening
    Dia.
    Includes
    Each
    Each
    304 Stainless Steel—IP24, NEMA 3R
    20041/8
    NPT
    Male80 to 10064120Wire Leads601 1/8"6 1/2"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    7275N1100000007273N990000000
    50081/8
    NPT
    Male80 to 10066120Wire Leads601 1/8"6 1/2"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    7275N120000007273N99000000
    1,100151/4
    NPT
    Male80 to 10072120Wire Leads601 1/2"10"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    7275N130000007273N99000000
    1,800251/4
    NPT
    Male80 to 10073120Wire Leads601 1/2"10"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    7275N14000000007273N99000000
    2,100301/4
    NPT
    Male80 to 10074120Wire Leads601 1/2"10"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    7275N15000000007273N99000000
    2,900401/4
    NPT
    Male80 to 10076120Wire Leads601 1/2"10"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    Solenoid Valve
    7275N16000000007273N99000000
     

    Washdown Enclosure-Cooling Vortex Tubes

    Image of Product. Front orientation. Vortex Tubes. Washdown Enclosure-Cooling Vortex Tubes.
    Suitable for washdown applications, these vortex tubes are NEMA rated to resist washdowns. They convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. These vortex tubes chill compressed air by 50° F or more. They include a ducting kit to distribute cool air throughout the enclosure.
    NEMA 4 Enclosure Rating—NEMA 4 rated vortex tubes resist dirt and washdowns.
    NEMA 4X Enclosure Rating—NEMA 4X rated vortex tubes resist dirt, washdowns, and corrosion.
    Replacement Filters—Replacement filters are sold separately.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Dia.
    Ht.
    For Opening
    Dia.
    Includes
    Each
    Each
    Aluminum—NEMA 4
    900153/8
    NPT
    Female80 to 100712"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K4600000001754K520000000
    1,500253/8
    NPT
    Female80 to 100842"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K470000001754K52000000
    2,500351/4
    NPT
    Female80 to 100882"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K360000001754K52000000
     
    304 Stainless Steel—NEMA 4X
    900151/4
    NPT
    Female80 to 100712"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K38000000001754K52000000
    1,700251/4
    NPT
    Female80 to 100842"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K22000000001754K52000000
    2,500351/4
    NPT
    Female80 to 100882"9 15/16"1 15/16"Ducting Kit
    Inline Compressed Air Filter
    1754K13000000001754K52000000
     

    Hazardous Location Enclosure-Cooling Vortex Tubes

    Image of Product. Front orientation. Vortex Tubes. Hazardous Location Enclosure-Cooling Vortex Tubes.
    UL classified for hazardous locations, these vortex tubes convert compressed air into a stream of cold air to keep electronics within enclosures from overheating while also keeping dust and other contaminants out. They chill compressed air by 50° F or more. These vortex tubes have a check valve that seals the air outlet when the unit is not in use, allowing the enclosure to be pressurized. All include a ducting kit to distribute cool air throughout the enclosure.
    5,000 BTU/hr Cooling Capacity—Vortex tubes with a cooling capacity of 5,000 Btu/hr. have dual air outlets that release two cold air streams. They’re good for cooling down large enclosures and electronics that generate a lot of heat. You can direct the air streams separately to target specific electronics. These vortex tubes take up more space inside of enclosures than those with a lower cooling capacity.
    Replacement Filters—Replacement filters are sold separately.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Max. Volume @
    Distance
    Ht.
    Wd.
    Dp.
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Each
    With Fixed Thermostat Control (80° F to 90° F)
     
    Plastic
    900153/8
    NPT
    Female80 to 10060 dBA @ 1 ft.8"4 3/4"5 3/8"NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEC Class III Division 2
    NEMA 4X
    1754K480000000001754K520000000
    2,500353/8
    NPT
    Female80 to 10072 dBA @ 1 ft.8"4 3/4"5 3/8"NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G; NEC Class III Division 2
    NEMA 4X
    1754K51000000001754K52000000
     
    With Fixed Thermostat Control (75° F to 100° F)
     
    Plastic
    5,000703/8
    NPT
    Female90 to 10075 dBA @ 1 ft.6 7/16"9 7/16"5 9/16"NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G
    NEMA 4X
    1754K55000000001754K56000000
     

    Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes

    Image of System. Vortex Tube and Included Parts Shown Installed. Front orientation. Vortex Tubes. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes.
    Image of Product. Vortex Tube. Front orientation. Vortex Tubes. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes.
    Image of Product. Replacement Filter. Front orientation. Vortex Tube Filters. Quiet Weather-Resistant Enclosure-Cooling Vortex Tubes.

    Vortex Tube and Included Parts Shown

    Installed

    Vortex

    Tube

    Replacement

    Filter

    Quietly cool electronics inside enclosures while keeping out rain, snow, splashing water, and dirt. These vortex tubes have mufflers on both the hot and cold air outlets to reduce noise. They use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Dia.
    Ht.
    For Opening
    Dia.
    Includes
    Each
    Each
    304 Stainless Steel—IP24, NEMA 3R
    20041/8
    NPT
    Male80 to 100582 1/4"12 1/2"2 1/4"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    7274N1100000007273N990000000
    50081/8
    NPT
    Male80 to 100602 1/4"12 1/2"2 1/4"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    7274N120000007273N99000000
    1,100151/4
    NPT
    Male80 to 100672 13/16"16"2 13/16"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    7274N130000007273N99000000
    1,800251/4
    NPT
    Male80 to 100682 13/16"16"2 13/16"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    7274N140000007273N99000000
    2,100301/4
    NPT
    Male80 to 100682 13/16"16"2 13/16"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    7274N150000007273N99000000
    2,900401/4
    NPT
    Male80 to 100672 13/16"16"2 13/16"Automatic Water Drain Filter
    Cold-Air Muffler
    Ducting Kit
    Hot-Air Muffler
    7274N160000007273N99000000
     

    Weather-Resistant Enclosure-Cooling Vortex Tubes

    Image of System. Vortex Tube and Included Parts Shown Installed. Front orientation. Vortex Tubes. Weather-Resistant Enclosure-Cooling Vortex Tubes.
    Image of Product. Vortex Tube. Front orientation. Vortex Tubes. Weather-Resistant Enclosure-Cooling Vortex Tubes.
    Image of Product. Replacement Filter. Front orientation. Vortex Tube Filters. Weather-Resistant Enclosure-Cooling Vortex Tubes.

    Vortex Tube and Included Parts Shown

    Installed

    Vortex

    Tube

    Replacement

    Filter

    Cool electronics inside enclosures while keeping out rain, snow, splashing water, and dirt. These vortex tubes use compressed air, making them a lower-maintenance choice than electric air conditioners. Adjust the ducting to spread air evenly in your enclosure or to cool specific parts. A filter captures and drains moisture from the air to protect your equipment from water damage.
    Vortex Tubes
    Replacement
    Filters
    Air Inlet
    Overall
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Pipe
    Size
    Thread
    Type
    Gender
    Req. Air Pressure,
    psi
    Volume (Sound),
    dBA
    Dia.
    Ht.
    For Opening
    Dia.
    Includes
    Each
    Each
    304 Stainless Steel—IP24, NEMA 3R
    20041/8
    NPT
    Male80 to 100641 1/8"6 1/2"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    7273N1100000007273N990000000
    50081/8
    NPT
    Male80 to 100661 1/8"6 1/2"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    7273N120000007273N99000000
    1,100151/4
    NPT
    Male80 to 100721 1/2"10"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    7273N130000007273N99000000
    1,800251/4
    NPT
    Male80 to 100731 1/2"10"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    7273N140000007273N99000000
    2,100301/4
    NPT
    Male80 to 100741 1/2"10"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    7273N150000007273N99000000
    2,900401/4
    NPT
    Male80 to 100761 1/2"10"1 1/8"Automatic Water Drain Filter
    Ducting Kit
    7273N160000007273N99000000
     
    back to top