Static-Eliminating Blowguns
Eliminate static charges and guard against ESD (electrostatic discharge) in electronics assembly and clean room applications. This blowgun requires a clean, dry air supply. A filter at the nozzle tip ensures that the air is clean. Gun conforms to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure. Volume (dBA) is measured 3 ft. from the blowgun at 100 psi.
Air Inlet | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume, dBA | Static Neutralizing Distance | Removes Particle Size Down To, microns | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Environmental Rating | Specifications Met | Each | |
Straight | ||||||||||||||
7 7/8" | 7.4 cfm @ 100 psi | 97 | 4"-10" | 0.01 | 100 | 1/4 | NPT | Female | Nickel Alloy | 120V AC | Fed. Std. Class 1,000; ISO Class 6 | OSHA Compliant 29 CFR 1910.242 | 00000000 | 000000000 |
Hands-Free Static-Eliminating Blowguns
Bend the stand's flexible arm to position the blowgun and it will stay in place. Step on the included foot pedal to activate airflow and static elimination. Good for electronics assembly and clean room applications, this blowgun requires a clean, dry air supply. It conforms to OSHA Compliant 29 CFR 1910.242 requirements for maximum air outlet pressure.
Air Inlet | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Static Neutralizing Distance | Arm Lg. | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Specifications Met | Each | |
Straight | |||||||||||||
7 7/8" | 7.4 cfm @ 100 psi | Not Rated | 1"-36" | 18" | 100 | 1/4 | NPT | Female | Nickel Alloy | 120V AC | C-UL Listed, UL Listed, OSHA Compliant 29 CFR 1910.242 | 0000000 | 000000000 |
Replacement Steel Foot Pedals | 0000000 | Each | 0000000 |
High-Airflow Static-Eliminating Blowguns
This blowgun provides more than three times the airflow of a standard blowgun. Good for electronics assembly and clean room applications, it eliminates static charges and guards against ESD (electrostatic discharge). Gun requires a clean, dry air supply. Blowguns and replacements conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure and OSHA 29 CFR 1910.95 requirements for noise. Volume (dBA) is measured 3 ft. from the blowgun at 100 psi.
Air Inlet | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume, dBA | Static Neutralizing Distance | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Specifications Met | Each | |
Straight | ||||||||||||
3 7/16" | 24 cfm @ 100 psi | 85 | 2"-10 ft. | 250 | 1/4 | NPT | Female | 303 Stainless Steel | 120V AC | C-UL Recognized Component, UL Recognized Component, OSHA Compliant 29 CFR 1910.242, OSHA Compliant 29 CFR 1910.95 | 0000000 | 000000000 |
Replacement Blowguns with Cable | 0000000 | Each | 0000000 |