Housing | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Max. Flow Rate | Max. Pressure, psi | Max. Temp., °F | Material | Clarity | Filter Element Material | Removes Particle Size Down To, microns | Each | |
1/8 | NPT | 10 cfm @ 100 psi | 300 | 300° | Brass | Opaque | Bronze | 000000000 | 00000 | |
1/4 | NPT | 23 cfm @ 100 psi | 300 | 300° | Brass | Opaque | Bronze | 000000000 | 00000 | |
3/8 | NPT | 32 cfm @ 100 psi | 300 | 300° | Brass | Opaque | Bronze | 000000000 | 00000 | |
1/2 | NPT | 59 cfm @ 100 psi | 300 | 300° | Brass | Opaque | Bronze | 000000000 | 00000 |

Housing | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Tube ID | Tube Connection Type | Max. Flow Rate | Max. Pressure | Material | Clarity | Color | Removes Particle Size Down To, microns | Each | |
1/4" | Barbed | Not Rated | 100 psi @ 73° F | Acetal Plastic | Opaque | White | 0000000 | 00000 | |
1/4" | Barbed | Not Rated | 100 psi @ 73° F | Acetal Plastic | Opaque | White | 0000000 | 0000 | |
3/8" | Barbed | Not Rated | 100 psi @ 73° F | Acetal Plastic | Opaque | White | 0000000 | 0000 |

Housing | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Tube ID | Tube Connection Type | Max. Flow Rate | Max. Pressure | Max. Temp., °F | Material | Clarity | Removes Particle Size Down To, microns | Each | |
1/8" | Barbed | Not Rated | 50 psi @ 73° F | Not Rated | Acetal Plastic | Opaque | 0000000 | 00000 | |
3/16" | Barbed | Not Rated | 50 psi @ 73° F | Not Rated | Acetal Plastic | Opaque | 0000000 | 0000 | |
1/4" | Barbed | Not Rated | 50 psi @ 73° F | Not Rated | Acetal Plastic | Opaque | 0000000 | 0000 | |
5/16" | Barbed | Not Rated | 50 psi @ 73° F | Not Rated | Acetal Plastic | Opaque | 0000000 | 0000 |

Housing | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Tube ID | Tube Connection Type | Max. Flow Rate | Max. Pressure, psi | Max. Temp., °F | Material | Clarity | Removes Particle Size in Air Down To, microns | Removes Particle Size in Liquids Down To, microns | Features | Each | |
1/4" | Tube Stem | 0.25 gpm @ 5 psi 6.6 scfm @ 125 psi | 125 | 230° | Nylon Plastic | Clear | 0.01 | 2 | __ | 000000 | 000000 |
1/4" | Tube Stem | 0.43 gpm @ 5 psi 7.3 scfm @ 125 psi | 125 | 230° | Nylon Plastic | Clear | 0.01 | 2 | __ | 0000000 | 00000 |
1/4" | Tube Stem | 0.5 gpm @ 5 psi 10 scfm @ 125 psi | 125 | 230° | Nylon Plastic | Clear | 0.01 | 25 | __ | 000000 | 00000 |
1/4" | Tube Stem | 0.75 gpm @ 5 psi 14.6 scfm @ 125 psi | 125 | 230° | Nylon Plastic | Clear | 0.01 | 25 | __ | 0000000 | 00000 |
1/4" | Tube Stem | 6.6 scfm @ 125 psi | 125 | 230° | Nylon Plastic | Clear | 0.01 | Not Rated | Filter-Change Indicator | 0000000 | 00000 |

Housing | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Tube ID | Tube Connection Type | Max. Flow Rate | Max. Pressure, psi | Max. Temp., °F | Material | Clarity | Color | Removes Particle Size in Air Down To, microns | Removes Particle Size in Liquids Down To, microns | Each | |
3/16", 1/4" | Barbed | 0.25 gpm @ 5 psi 6.6 scfm @ 125 psi | 125 | 230° | Nylon Plastic | Clear | Clear | 0.01 | 2 | 0000000 | 000000 |
3/16", 1/4" | Barbed | 0.5 gpm @ 5 psi 10 scfm @ 125 psi | 125 | 230° | Nylon Plastic | Clear | Clear | 0.01 | 25 | 0000000 | 00000 |

Housing | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Tube ID | Tube Connection Type | Max. Flow Rate | Max. Pressure, psi | Max. Temp., °F | Material | Clarity | Color | Removes Particle Size in Air Down To, microns | Removes Particle Size in Liquids Down To, microns | Each | |
1/4" | Tube Stem | 0.25 gpm @ 5 psi 6.6 scfm @ 125 psi | 125 | 275° | PVDF Plastic | Opaque | Blue | 0.01 | 2 | 000000 | 000000 |
1/4" | Tube Stem | 0.43 gpm @ 5 psi 7.3 scfm @ 125 psi | 125 | 275° | PVDF Plastic | Opaque | Blue | 0.01 | 2 | 0000000 | 00000 |
1/4" | Tube Stem | 0.5 gpm @ 5 psi 10 scfm @ 125 psi | 125 | 275° | PVDF Plastic | Opaque | Blue | 0.01 | 25 | 000000 | 00000 |
1/4" | Tube Stem | 0.75 gpm @ 5 psi 14.6 scfm @ 125 psi | 125 | 275° | PVDF Plastic | Opaque | Blue | 0.01 | 25 | 0000000 | 00000 |

Housing | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Tube ID | Tube Connection Type | Max. Flow Rate, gpm | Max. Pressure, psi | Max. Temp., °F | Material | Clarity | Color | Removes Particle Size Down To, microns | Pkg. Qty. | Pkg. | |
6 mm-10 mm | Barbed | 0.053 | 60 | 265° | Polypropylene Plastic | Semi-Clear | White | 0.1 | 10 | 0000000 | 0000000 |
6 mm-10 mm | Barbed | 0.238 | 60 | 265° | Polypropylene Plastic | Semi-Clear | White | 1 | 10 | 0000000 | 000000 |
High-Pressure Inline Filters
Remove small particles in lines that reach up to 5,000 psi to protect sensitive equipment, such as hydraulic controls. These inline filters act as a secondary defense to trap particles that make it past your intake filter without adding bulk to your line.
Brass filters resist some corrosion. Stainless steel filters resist corrosion better than brass filters.
Choose filters with an access port to install a new filter element without replacing the entire unit or removing it from your line. These filters take up slightly more space than those without access ports.


Pipe Size | Removes Particle Size Down To, microns | Features | Max. Pressure, psi | Max. Temp., °F | Each | |
Brass Housing | ||||||
---|---|---|---|---|---|---|
1/8 | 10 | __ | 1,000 | 300° | 0000000 | 000000 |
1/4 | 10 | __ | 1,000 | 300° | 0000000 | 00000 |
1/4 | 10 | Filter Access Port | 3,000 | 450° | 0000000 | 000000 |
316 Stainless Steel Housing | ||||||
1/8 | 10 | __ | 3,000 | 450° | 0000000 | 000000 |
1/4 | 10 | __ | 3,000 | 450° | 0000000 | 000000 |
1/4 | 10 | Filter Access Port | 5,000 | 450° | 0000000 | 000000 |

Brass Housing | 303 Stainless Steel Housing | ||||||||
---|---|---|---|---|---|---|---|---|---|
Removes Particle Size Down To, microns | Pipe Size | Max. Pressure, psi | Max. Temp., °F | Each | Max. Pressure, psi | Max. Temp., °F | Each | ||
10 | 1/8 | 2,000 | 200° | 000000 | 000000 | 4,000 | 200° | 0000000 | 000000 |
10 | 1/4 | 2,000 | 200° | 0000000 | 00000 | 4,000 | 200° | 0000000 | 00000 |
15 | 1/8 | 2,000 | 200° | 0000000 | 00000 | 4,000 | 200° | 0000000 | 00000 |
15 | 1/4 | 2,000 | 200° | 0000000 | 00000 | 4,000 | 200° | 0000000 | 00000 |
25 | 1/8 | 2,000 | 200° | 0000000 | 00000 | 4,000 | 200° | 000000 | 00000 |
25 | 1/4 | 2,000 | 200° | 0000000 | 00000 | 4,000 | 200° | 0000000 | 00000 |
100 | 1/8 | 2,000 | 200° | 0000000 | 00000 | 4,000 | 200° | 0000000 | 00000 |
100 | 1/4 | 2,000 | 200° | 0000000 | 00000 | 4,000 | 200° | 0000000 | 00000 |


For Tube OD | Removes Particle Size Down To, microns | Features | Max. Pressure, psi | Max. Temp., °F | Each | |
Brass Housing | ||||||
---|---|---|---|---|---|---|
1/8" | 10 | Filter Access Port | 3,000 | 450° | 0000000 | 0000000 |
1/4" | 10 | __ | 1,000 | 300° | 0000000 | 00000 |
1/4" | 10 | Filter Access Port | 3,000 | 450° | 0000000 | 000000 |
316 Stainless Steel Housing | ||||||
1/8" | 10 | Filter Access Port | 5,000 | 450° | 0000000 | 000000 |
1/4" | 10 | __ | 3,000 | 450° | 0000000 | 000000 |
1/4" | 10 | Filter Access Port | 5,000 | 450° | 0000000 | 000000 |

Ht. | OD | ID | Removes Particle Size Down To, microns | Material | Max. Temp., ° F | Each | |
3/4" | 1/2" | 3/8" | 10 | 316 Stainless Steel | 450° | 0000000 | 000000 |
High-Vacuum Inline Filters
Capture oil, oil vapor, and other contaminants from your pump to prevent them from spreading into your high-vacuum system with these filters. When it's time to replace the filter element, you don't need tools to access it; undo the quick-release clamp to open the filter body. Filters have a drain port to remove collected oil.
Filters with quick-clamp connections (also known as KF, NW, and QF fittings) require a quick clamp and a ring (both sold separately) for each connection.
Filters with claw-clamp connections (also known as ISO-K fittings) will connect to larger components than filters with quick-clamp connections. Use four claw clamps and a ring (all sold separately) to secure each connection. Double-claw clamps attach to the grooves on the fittings. Single-claw clamps have a clamp on one end and an exposed bolt on the other. Thread the bolt-end directly into the body of pumps, valves, or other high-vacuum components.
For technical drawings and 3-D models, click on a part number.

Inline Filters | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
O'all | Replacement Elements | ||||||||||||
High-Vacuum Flange Size | Flange OD | For Tube OD | Max. Flow Rate | High Vacuum Connection Type | Max. Vacuum | Max. Temp., °F | Lg. | Dia. | Removes Particle Size Down To, microns | Each | Each | ||
Quick-Clamp Connection—304 Stainless Steel Housing | |||||||||||||
16 | 1.18" | 3/4" | 50 scfm @ 14.7 psi | ISO-KF | 1 × 10 -3 torr @ 72° F | 300° | 8 3/4" | 5 1/4" | 0.1 | 0000000 | 0000000 | 0000000 | 000000 |
25 | 1.57" | 1" | 50 scfm @ 14.7 psi | ISO-KF | 1 × 10 -3 torr @ 72° F | 300° | 8 3/4" | 5 1/4" | 0.1 | 0000000 | 000000 | 0000000 | 00000 |
40 | 2.16" | 1 1/2" | 100 scfm @ 14.7 psi | ISO-KF | 1 × 10 -3 torr @ 72° F | 300° | 11 1/4" | 7 3/8" | 0.1 | 0000000 | 000000 | 0000000 | 000000 |
50 | 2.95" | 2" | 200 scfm @ 14.7 psi | ISO-KF | 1 × 10 -3 torr @ 72° F | 300° | 11 1/4" | 7 3/8" | 0.1 | 0000000 | 00000000 | 0000000 | 000000 |
Claw-Clamp Connection—304 Stainless Steel Housing | |||||||||||||
63 | 3.74" | 2 1/2" | 300 scfm @ 14.7 psi | ISO-K | 1 × 10 -3 torr @ 72° F | 300° | 18 1/8" | 9" | 0.1 | 0000000 | 00000000 | 0000000 | 000000 |



For High-Vacuum Flange Size | For Flange OD | For Tube OD | High Vacuum Connection Type | Material | Max. Vacuum | Each | |
Quick-Clamp Connection—Clamp with Wing Nut | |||||||
---|---|---|---|---|---|---|---|
10; 16 | 1.18" | 1/2"; 3/4" | ISO-KF | Aluminum | 1 × 10 -7 torr @ 72° F | 00000000 | 00000 |
25 | 1.57" | 1" | ISO-KF | Aluminum | 1 × 10 -7 torr @ 72° F | 0000000 | 00000 |
40 | 2.16" | 1 1/2" | ISO-KF | Aluminum | 1 × 10 -7 torr @ 72° F | 0000000 | 00000 |
50 | 2.95" | 2" | ISO-KF | Aluminum | 1 × 10 -7 torr @ 72° F | 0000000 | 00000 |
Claw-Clamp Connection—Double-Claw Clamp with Bolt | |||||||
63; 80; 100 | 3.74", 4.33", 5.12" | 2 1/2"; 3"; 4" | ISO-K | Aluminum | 1 × 10 -9 torr @ 72° F | 0000000 | 0000 |
Claw-Clamp Connection—Single-Claw Clamp with Bolt | |||||||
63; 80; 100 | 3.74", 4.33", 5.12" | 2 1/2"; 3"; 4" | ISO-K | Aluminum | 1 × 10 -9 torr @ 72° F | 0000000 | 0000 |

Material | |||||||||
---|---|---|---|---|---|---|---|---|---|
For High-Vacuum Flange Size | For Flange OD | For Tube OD | High Vacuum Connection Type | O-Ring | Inner Ring | Max. Vacuum | Max. Temp., °F | Each | |
Quick-Clamp Connection | |||||||||
16 | 1.18" | 3/4" | ISO-KF | Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | 300° | 00000000 | 00000 |
25 | 1.57" | 1" | ISO-KF | Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | 300° | 0000000 | 00000 |
40 | 2.16" | 1 1/2" | ISO-KF | Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | 300° | 0000000 | 00000 |
50 | 2.95" | 2" | ISO-KF | Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -7 torr @ 72° F | 300° | 0000000 | 00000 |
Claw-Clamp Connection | |||||||||
63 | 3.74" | 2 1/2" | __ | Viton® Fluoroelastomer Rubber | 304 Stainless Steel | 1 × 10 -9 torr @ 72° F | 400° | 0000000 | 00000 |