Wall-Mount Timer Switches
Use these switches in place of standard wall switches to automatically turn electrical equipment on or off after a set interval of time. They’re often used with lights.
Switches with override can bypass the automatic shut-off.
Set switches with beep and light signals to alert when the timer is almost done; the signals can also be turned off.
Switches with set time recall retain the last setting; hold the button down to restart the timer with that setting.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Choose a Knob Color | Each | |
Without Override | ||||||||
---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 40 sec.-5 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 000000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
With Override | ||||||||
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 | |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 0000000 | 00000 |
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Knob Color | Each | |
Without Override | ||||||||
---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-5 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 000000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 4 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 0000000 | 00000 |
With Override | ||||||||
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 min.-5 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 4 min.-30 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 10 min.-60 min. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 1 hrs.-6 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
1 | 1 Off (Normally Open) | 20 A @ 125 V AC, 10 A @ 250 V AC | 2 hrs.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | Ivory | 000000 | 00000 |
Replacement Knob | 0000000 | Each | 00000 |
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Color | CSA File Number | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 15 A @ 120 V AC | 2 hrs., 4 hrs., 8 hrs., 12 hrs. | 1 Device (1 Gang) | Wire Leads | White | __ | 00000000 | 000000 |
1 | 1 Off (Normally Open) | 15 A @ 120 V AC | 5 min., 10 min., 15 min., 30 min. | 1 Device (1 Gang) | Wire Leads | White | 003413_0_000 | 00000000 | 00000 |
Countdown LCD
and Set Time Recall
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Choose a Color | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 41 mA @ 24 V AC, 12 mA @ 24 V DC | __ | 5 min.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 000000 | 000000 | |
1 | 1 Off (Normally Open) | 6.6 A @ 120 V AC, 4.3 A @ 277 V AC | 1/6 hp @ 125 V AC | 5 min.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 000000 | 00000 |
High-Current Wall-Mount Timer Switches
Control equipment with high currents such as air conditioners, heaters, and ventilating equipment. They automatically turn electrical equipment on or off after a set interval of time.
Switches with override can bypass the automatic shut-off.
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time | For Outlet Box Type | Includes | Wire Connection Type | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 0000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
Without Override | |||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 1 min.-1 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
2 | 1 Off (Normally Open) | 28 A @ 120 V AC/240 V AC | 1 hp @ 120 V AC, 1 hp @ 240 V AC | 15 min.-12 hrs. | 2 Device (2 Gang) | Steel Wall Plate | Screw Terminals | 0000000 | 000000 |
Replacement Knob | 0000000 | Each | 000000 |
Time-Delay Wall-Mount Timer Switches
Control two devices and delay the shut off of one device by up to one hour. These switches are often used with lights and fans for ventilation. All have an override that bypasses the automatic shut-off.
Color | No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time, min. | For Outlet Box Type | Wire Connection Type | Each | |
Ivory | 2 | 1 Off (Normally Open) | 4.1 A @ 120 V AC | 1/3 hp @ 120 V AC | 1-60 | 1 Device (1 Gang) | Wire Leads | 0000000 | 000000 |
White | 2 | 1 Off (Normally Open) | 4.1 A @ 120 V AC | 1/3 hp @ 120 V AC | 1-60 | 1 Device (1 Gang) | Wire Leads | 0000000 | 00000 |
Time and Day Activated Switches
Program these switches to turn a device on and off at a set time and day. They have a three-prong outlet to plug devices directly into the switch. Use with lamps and other small electrical loads. All have an override to bypass the programmed on/off settings.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week.
Switches with trippers are programmed by setting on and off times by positioning trippers around the clock dial.
Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | No. of Trippers | Switching Current @ Voltage | No. of Outlets | Features | Ht. | Wd. | Dp. | Plug Type | Each | |
24-Hour Timing Cycle | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3 per Day | 30 min. | Trippers | Removable | 6 | 15 A @ 120 V AC | 1 | __ | 3 1/4" | 3 1/4" | 3 1/4" | Three Prong | 0000000 | 000000 |
7-Day Timing Cycle | |||||||||||||
14 per Day | 1 min. | Push Button | __ | __ | 15 A @ 120 V AC | 2 | Astronomical Timing, Random On/Off Option | 3" | 3 1/2" | 3 1/2" | Three Prong | 0000000 | 00000 |
Outdoor Time and Day Activated Switches
Designed to work with landscape lighting and filter pumps, these switches turn equipment on and off at a set time and day. They control two devices at once, and have three-prong outlets to plug devices directly into the switch. All have an override to bypass the programmed on/off settings.
24-hour switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
Seven-day switches can perform a different program each day of the week. They have astronomical timing that can be set to turn lights on and off based on sunrise and sunset.
Switches with light sensor control allow one device to be controlled by the presence or absence of light.
NEMA 3R rated switches are protected against falling liquids and light splashing.
Mounting | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | No. of Trippers | Switching Current @ Voltage | No. of Outlets | Features | Ht. | Wd. | Dp. | Plug Type | Cord Lg., ft. | Fasteners Included | No. of Holes | Hole Dia. | Min. Ht., ft. | Each | |
24-Hour Timing Cycle—NEMA 3R | ||||||||||||||||||
12 per Day | 30 min. | Trippers | Removable | 4 | 15 A @ 120 V AC | 2 | Light Sensor Control | 9 3/8" | 5 1/2" | 3 3/8" | Three Prong | 2 | No | 4 | 1/4" | __ | 0000000 | 0000000 |
7-Day Timing Cycle | ||||||||||||||||||
7 per Day | 1 min. | Push Button | __ | __ | 15 A @ 120 V AC | 2 | Astronomical Timing, Random On/Off Option | 5 1/8" | 5 1/4" | 1 7/8" | Three Prong | 2 | No | 2 | 0.31" | 4.5 | 0000000 | 00000 |
Additional Trippers (Pkg. of 2 Pairs) | 0000000 | Pkg. | 00000 |