McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    9 Products

    Flame- and Arc-Flash-Protection Base Layer Shirts

    Wear these fitted garments under clothing for an added layer of protection against intermittent exposure to flames and radiant heat. They meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 1 or 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. All base layer materials are lightweight, breathable, and moisture wicking for added comfort.
    They all comply with OSHA 29 CFR 1910.269 standards for flame and arc flash protection.
    When measuring chest size, measure around the fullest part of your chest.
    Men's Clothes
    Image of Product. Front orientation. Shirts. Flame- and Arc-Flash-Protection Base Layer Shirts, Men's Clothes, Short-Sleeve Shirt.
    Image of Product. Front orientation. Shirts. Flame- and Arc-Flash-Protection Base Layer Shirts, Men's Clothes, Long-Sleeve Shirt.

    Short-Sleeve Shirt

    Long-Sleeve Shirt

    Acrylic/Cotton Fabric—Acrylic/cotton base layers are stretchy for increased mobility and range of motion.
    Material
    Arc Rating,
    cal/cm²
    Arc-Rated
    PPE Category
    Cuff
    Style
    Specs. Met
    Flammability Rating
    Color
    Choose a Size (Chest Size)
    Each
    Short-Sleeve Shirt
    Acrylic/Cotton Fabric41
    OpenOSHA Compliant 29 CFR 1910.269
    NFPA 70E, ASTM F1506
    Dark Blue
    S (34", 36")
    ,
    M (38", 40")
    ,
    L (42", 44")
    ,
    XL (46", 48")
    ,
    2XL (50", 52")
    ,
    3XL (54", 56")
    1574N510000000
     
    Long-Sleeve Shirt
    Acrylic/Cotton Fabric41
    KnitOSHA Compliant 29 CFR 1910.269
    NFPA 70E, ASTM F1506
    Dark Blue
    S (34", 36")
    ,
    M (38", 40")
    ,
    L (42", 44")
    ,
    XL (46", 48")
    ,
    2XL (50", 52")
    ,
    3XL (54", 56")
    1574N62000000
     
    Women's Clothes
    Image of Product. Front orientation. Shirts. Flame- and Arc-Flash-Protection Base Layer Shirts, Women's Clothes.
    Material
    Arc Rating,
    cal/cm²
    Arc-Rated
    PPE Category
    Cuff
    Style
    Closure
    Method
    Specs. Met
    Flammability Rating
    Color
    Choose a Size (Chest Size)
    Each
    Long-Sleeve Shirt
    Carbon Fiber Fabric132
    OpenButtonOSHA Compliant 29 CFR 1910.269
    NFPA 70E, NFPA 2112, ASTM F1506
    Brown
    XS (30", 32")
    ,
    S (34", 36")
    ,
    M (38", 40")
    ,
    L (42", 44")
    ,
    XL (46", 48")
    ,
    2XL (50", 52")
    ,
    3XL (54", 56")
    5122N110000000
     

    Flame- and Arc-Flash-Protection Base Layers

    Wear these fitted garments under clothing for an added layer of protection against intermittent exposure to flames and radiant heat. They meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 1 or 2. Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating. Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance. All base layer materials are lightweight, breathable, and moisture wicking for added comfort.
    They all comply with OSHA 29 CFR 1910.269 standards for flame and arc flash protection.
    Men's Pants
    Image of Product. Front orientation. Pants. Flame- and Arc-Flash-Protection Base Layers , Men's Pants.
    Acrylic/Cotton Fabric—Acrylic/cotton base layers are stretchy for increased mobility and range of motion.
    Arc-Rated
    PPE Category
    Arc Rating,
    cal/cm²
    Closure
    Method
    Cuff
    Style
    Specs. Met
    Flammability Rating
    Color
    Choose a Size (Waist Size × Inseam Lg.)
    Each
    Acrylic/Cotton Fabric
    1
    4ElasticKnitOSHA Compliant 29 CFR 1910.269
    NFPA 70E, ASTM F1506
    Dark Blue
    S (27" to 29" × 31")
    ,
    M (30" to 33" × 32")
    ,
    L (32" to 35" × 33")
    ,
    XL (36" to 39" × 34")
    ,
    2XL (40" to 43" × 34")
    ,
    3XL (42" to 45" × 35")
    1574N520000000
     

    Flame- and Arc-Flash-Protection Hard Hat Liners

    Often used in utility work, metalworking, and welding, these hard-hat liners meet NFPA 70E to protect from flames and electrical arc flashes. They also shield your head and nape from the wind and cold. Secure the liner to your hard hat with the attached hook and loop tabs on each side. Choose a hard-hat liner that meets the arc rated personal protective equipment (PPE) category required by your workplace.
    Hard Hat Liners
    Image of ProductInUse. Front orientation. Hard Hat Liners. Flame- and Arc-Flash-Protection Hard Hat Liners, Covers Head, Nape, and Neck, Two Layers of Insulation, Warming Pad Slots.
    Image of ProductInUse. Front orientation. Hard Hat Liners. Flame- and Arc-Flash-Protection Hard Hat Liners, Covers Head and Nape.

    Covers Head, Nape, and Neck

    Two Layers of Insulation

    Warming Pad Slots

    Covers Head and Nape

    Image of ProductInUse. Front orientation. Hard Hat Liners. Flame- and Arc-Flash-Protection Hard Hat Liners, Covers Head and Nape, Removable Nape Cover, Warming Pad Slots.
    Image of ProductInUse. Warming Pad Slot (Warming Pads Sold Separetely). Front orientation. Warming Pad Slots. Flame- and Arc-Flash-Protection Hard Hat Liners.

    Covers Head and Nape

    Removable Nape Cover

    Warming Pad Slots

    Warming Pad Slot (Warming Pads

    Sold Separetely)

    Covers Head, Nape, and Neck—Liners with head, nape, and neck coverage have two layers of insulation inside the flame-resistant shell to protect against the cold: a mid-layer of aramid/modacrylic fabric and an inner layer of cotton/modacrylic fleece.
    Removable Nape Cover—Liners with a removable nape cover allow you to cool off your nape by zipping off the back. With the nape cover removed, the liner protects the head like a cap.
    Warming Pad Slots—Use liners with warming pad slots for extra warmth around the ears—slip hand warmer pads (sold separately) into the slots on each side.
    Application
    Arc-Rated
    PPE Category
    Arc Rating,
    cal/cm²
    Material
    Insulation Material
    Closure
    Method
    Features
    Color
    Wt.,
    oz.
    Hard Hat
    Size
    Flammability Rating
    Each
    Covers Head and Nape
    Arc-Flash Protection, Cold Protection2
    9.3Cotton FabricCotton FabricHook and LoopBlue2.8One SizeASTM F1506, NFPA 70E
    7996N14000000
    Arc-Flash Protection, Cold Protection2
    17Cotton/Modacrylic FabricCotton/Modacrylic FleeceHook and LoopRemovable Nape Cover, Warming Pad SlotsBlack3One SizeASTM F1506, NFPA 70E
    7996N1200000
     
    Covers Head, Nape, and Neck
    Arc-Flash Protection, Cold Protection327Cotton/Modacrylic FabricAramid/Modacrylic Fabric, Cotton/Modacrylic FleeceHook and LoopTwo Layers of Insulation, Warming Pad SlotsBlack5.1One SizeASTM F1506, NFPA 70E
    7996N1300000
     
    Hand Warmer Pads
    Masks
    Image of ProductInUse. Front orientation. Hard Hat Liners. Flame- and Arc-Flash-Protection Hard Hat Liners, Covers Face.

    Covers Face

    Add masks to protect your mouth, chin, and nose. They have hook and loop tabs on each side that stick to the sides of the liner.
    Application
    Arc-Rated
    PPE Category
    Arc Rating,
    cal/cm²
    Material
    Insulation Material
    Closure
    Method
    Color
    Wt.,
    oz.
    Flammability Rating
    Each
    Covers Face
    Arc-Flash Protection, Cold Protection2
    20Cotton/Modacrylic FabricCotton/Modacrylic FleeceHook and LoopBlack1.6ASTM F1506, NFPA 70E
    7996N11000000
     